APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Similar documents
MFP14 Automatic pumps. for condensate and other industrial fluids

MFP14 Automatic pumps for condensate and other industrial fluids

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Pump & Trap Combinations

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

FT14 Ball Float Steam Trap (Screwed)

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Silhouette. Feedwater Heater. Boiler Feedwater

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

PF Series. Piston Actuated Valves

HEAT EXCHANGER FORMULAS & EXAMPLE

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

What is a Secondary Pressure Drainer?

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Hoffman Specialty General Catalog

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

SECTION STEAM CONDENSATE PUMPS

Steam Water Washdown Unit

The right trap for the right application.

Inverted Bucket Steam Traps

Documento Descargado desde:

Refrigerant Valves/Accessories

STEAM TRAPS

Liquid Drainers LIQUID DRAINERS

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Electronic steam boiler controls

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Domestic Pump Condensate Transfer Equipment

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

SX65 and SX75. Electronic process controllers

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

CRU 200 and 500 Series Condensate Recovery Units

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

EasiHeat Mechanical Installation and Commissioning Instructions

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Flo-Rite-Temp Instantaneous Steam/Water Heater

THERMODYNAMIC STEAM TRAP

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

Flo-Rite-Temp Instantaneous Steam/Water Heater

Industrial Processing Solutions

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

Clean, Dry Air System

INSTALLATION, OPERATION

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Air Vents for Hot and Chilled Water Systems

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

David Cronin-Ohio Valley Area Manager. Heat Transfer, Controls & Instrumentation, Metering.

Thermostatic Steam Traps

Filtering Ideas, Making Innovations

AFUE 95% Heating Input 50,000 to 200,000 Btuh

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

INSTALLATION AND MAINTENANCE INSTRUCTIONS. IM US March RediHeat. Table Of Contents. I. Installation RediHeat Start-Up Procedure 4

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Intelligent Refrigeration Solutions

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

heating liquids PENBERTHY JET PUMP TECHNICAL DATA Section 1000 Bulletin 1400 Issued 6/87 Replaces 6/85

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Disc Type Steam Trap TSD-42

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

Packaged Steam Fired Water Heater

Industrial Applications

In-Line Air Separators

Product overview. the optimum components for every application

INSTALLATION, OPERATION

Our Know-How. Your Peace of Mind. Steam Solutions

Steam-Atomising Desuperheater

Hydrocarbon & Chemical Processing Solutions

Peerless Pump Company

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

EXTROL EXPANSION TANKS

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

THE THERMOSTATIC STEAM TRAP

GESTRA. Product Overview. The optimum components for every application

CRU-S Series Stainless Steel Condensate Recovery Unit

FUEL-FIRED VERTICAL TUBELESS BOILERS

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

PIP PNE00004 Steam Trap Guidelines

ESCO. Committed. Group of Companies. to help conserve Steam Energy

TIMER CONTROLLED DRAINS

Concrete Applications

Transcription:

APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1

An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation head from the base of the pump. Convenient installation to low mounted process equipment. Removes condensate under all load conditions, even vacuum. Requires no electrical power - suitable for hazardous environments. High capacity in one simple package. Available with EN 10204 3.1.B certification as standard. Spirax Sarco s guarantee of worldwide technical support, knowledge and service. Problems These can be some of the problems with simply trapping a heat exchanger Poor heat transfer! Irregular temperature control! Corrosion! Noise and waterhammer! Tube failure! High maintenance costs! All too often these problems have remained unsolved because no fully engineered compact system was available. Solution This product is specifically designed to automatically recover and remove condensate, the instant it forms. It provides the unique opportunity to solve all condensate handling problems. The Result The APT will ensure your equipment operates as efficiently as possible - lowering energy consumption of the plant and allowing the process to run at optimum conditions - resulting in: Reduced costs. Increased productivity. Reduced downtime. Quieter equipment operation. 2

exchanger and heating coil drainage APT - Automatic pump trap For over 50 years, Spirax Sarco has been involved with the design and manufacture of products for efficient condensate management. We have now developed a compact, condensate drainage system in one simple-to-install product. The APT has been designed to remove condensate from steam heat exchangers and process plant under all operating conditions, and forms an integral part of the condensate removal process. It is available in two easy-to-specify options: APT10-4.5 for loads up to 2022 lbs/hr and the - for loads up to 9880 lbs/hr. Compactness is the key Compact design which contains all the equipment needed to drain or remove condensate for all load conditions. Innovative patent applied for low profile mechanism. All stainless steel internals, with low profile robust stainless steel floats. The APT s are unique, from its compact size to their patent applied for mechanisms. No other pressure operated pumps or traps in the world can offer all of the benefits shown on these pages. APT10-4.5 Low resistance swing type inlet check valve. High integrity trapped cover gasket. Positive snap action pump mechanism with replaceable valves and seats. High capacity two stage trap module plus precision ball outlet check valve. Mechanisms operate with as little as 8" installation head from the base of the pump. SG iron GGG 40.3 and A395 body and cover 3.1.B certifiable. Designed in accordance with ASME standards. Available connections: APT10-4.5 and Screwed NPT connectios with 1/2" screwed NPT motive fluid connections. The has the option of Flanged ANSI 150, with 1/2" screwed NPT motive fluid connections. 3

1 The APT10-4.5 and automatic pump trap operates on a positive displacement principle. enters the body through the inlet swing check valve causing the float to rise. The float is connected to the trap mechanism via a multi-link pivot. If the upstream system pressure PS is sufficient to overcome the back pressure PB (see below), the build up of condensate will be discharged through the opening two stage trap mechanism. In this way, the float will automatically modulate according to the rate of condensate entering the APT, controlling the rate of opening and closure of the trap. 1 The working cycle of inlet (PS) 6 As the pressure inside the APT equalizes with the condensate inlet pressure through the open exhaust valve, condensate re-enters via the inlet swing check valve. At the same time the outlet ball check valve ensures no condensate can drain back into the main chamber and the trapping or pumping cycle begins again. 6 outlet (PB) inlet (PS) PS outlet (PB) PB PS 5 As the condensate level falls within the main chamber, the float re-engages the change over linkage, causing the motive inlet to close and the exhaust valve to open. inlet (PS) outlet (PB) 4 5

the APT10-4.5 and 2 With some temperature controlled equipment, it is possible for the system pressure PS to be lower than the back pressure at PB. If this occurs a standard trap will stall allowing the condensate to flood the equipment being drained. 2 inlet (PS) outlet (PB) Secondary fluid outlet 3 However, with the APT, the condensate simply fills the main chamber - lifting the float until the changeover linkage is engaged, opening the motive inlet and closing the exhaust valve. 3 Motive steam inlet Secondary fluid inlet Motive steam inlet 4 The snap action mechanism ensures a rapid change from the trapping mode to the active pumping mode. With the motive inlet valve open, the pressure in the APT increases above the total back pressure and the condensate is forced out through the trap seat into the plant s return system. 4 5

Typical Applications removal from heater applications (Closed system) The APT can be used in single or multi-heater installations. Heater coils are particularly prone to corrosion and freeezing due to condensate retention. The APT provides the complete solution to traditional Air Handling Unit problems, and is ideal for any installation where head room is at a premium. APT10-4.5 removal from process vessels and heat exchangers (Closed system) The APT is simply connected to the outlet of the heat exhanger, or process vessel. No need for vacuum breakers the APT will drain condensate under all load conditions. giving exceptional temperature control at the heat exchange interface. reduce tube corrosion. Eliminate noise and waterhammer Extend equipment life. removal from vacuum equipment (Closed system) Simple and efficient solution to a difficult problem. Without the need for high Net Positive Suction Head NPSH, the APT will operate with only 8" installation head from the base of the pump, and remove condensate from a vacuum vessel, discharging it to either high or low level condensate return lines.* * Please note: These are typical applications only and some components have been omitted for clarity. Contact Spirax Sarco for full installation details. 6

How to size the APT... Simply contact your Spirax Sarco representative who can size an APT for your specific needs. Spirax Sarco will ensure that the APT is accurately matched to your process and will provide you with a detailed sizing chart, tailored to your specific application. Providing the information below is known, we can even provide you with confirmation over the telephone and fax you your specific chart. Alternatively arrange a visit for your local Spirax Sarco representative who can provide detailed APT sizing information for all your specific needs. To help us size the APT for your application, simply provide us with the following information:- C B * NB. Motive steam supply must be trapped and free of condensate. Recommended Installation Soft sealing check valve E Secondary fluid outlet F H D outlet Motive In 100 mesh strainer Out inlet Spirax Sarco sized length of pipe to act as a reservoir Minimum installation head 8 from base of pump Recommended the reservoir is installed at least 1 pipe diameter below the process outlet, but as high as possible above the APT inlet. A Secondary fluid intlet G A Installation head available from the base of the pump to the centreline of the heat exchanger/ process condensate outlet. B Motive steam pressure available to power the pump trap. ft psig C D E F Pressure in the condensate return system. Height of condensate return from floor level. Heat exchanger full load operating pressure. Maximum steam load on the heat exchanger. psig fl psig lb/hr G H Minimum secondary fluid temperature. F Maximum controlled temperature of secondary fluid. F 7

Range and options Automatic pump trap Type APT10-4.5 Body material SG iron ASTM A395 / GGG 40.3 SG iron ASTM A395 / GGG 40.3 Body design rating PN10 PN16 Nominal size 3/4" 1" Inlet / Outlet Connections Inlet / Outlet 3/4" Inlet 1-1/2 / Outlet 1 Screwed NPT NPT Flanged - ANSI 150 Motive fluid connections Motive inlet / exhaust 1/2" Motive inlet / exhaust 1/2" Screwed NPT NPT Self contained stainless steel pump mechanism Minimum installation head from base of the pump 8 in. Self contained stainless steel trap mechanism Float operated single stage Float operated twin stage Self contained stainless steel check valves Inlet - swing check, outlet - ball check Inlet - swing check, outlet - ball check Maximum operating pressure 65 psig 250 psig Maximum back pressure 58 psig 72 psig Maximum operating temperature 311 F 388 C Nominal capacities Pump discharge / cycle 0.55 gallons 1.3 gallons Maximum trapping capacity 2022 lb/hr 9880 lb/hr Maximum pumping capacity 1420 lb/hr 2450 lb/hr Reference Conditions Total back pressure 21 psig 14.5 psig Motive pressure 65 psig 70 psig Installation head 39 inches 39 inches Dimensions / Weights (approximate) in inches and lbs. (mm & kg) Type A B C D E F G H I Weight APT10-4.5 Screwed 7.4 (187) 0.9 (23) 8.8 (223) 10.9 (277) 10.7 (273) - 2.2 (57) 5.3 (135) 6.7 (171) 31 (14) Screwed 13.8 (350) 7.8 (198) 9.7 (246) 15 (382) 12 (304) 6.2 (157) 2.2 (57) 9.8 (250) 7.8 (198 ) 99 (45) Flanged 15.3 (389) 7.8 (198) 9.7 (246) 15 (382) 12 (304) 6.2 (157) 2.2 (57) 9.8 (250) 7.8 (198) 99 (45) Typical specification APT10-4.5 - The pump trap shall be a Spirax Sarco automatic pump trap type APT10-4.5 operated by steam to 65 psig. No electrical energy shall be required. Body construction from SG iron (ASTM A395 dual certified with DIN 1693 GGG 40.3) a swing type inlet check valve and ball type outlet check valve. The internal trap mechanism shall contain a stainless steel float connected with a single stage trap, while the internal pump mechanism shall be a stainless steel single tension spring snap-action device. The pump, trap, and check valve mechanisms shall be incorporated within the same body envelope with no external seals or glands and shall be capable of operating with a minimum of 8 inches installation head from the base of the unit. E D H Motive steam supply I B A G C - The pump trap shall be a Spirax Sarco automatic pump trap type operated by steam to 200 psig. No electrical energy shall be required. Body construction from SG iron (ASTM A395 dual certified with DIN 1693 GGG 40.3) a swing type inlet check valve and ball type outlet check valve. The internal trap mechanism shall contain dual stainless steel floats connected with a two stage trap, while the internal pump mechanism shall be a stainless steel single tension spring snap-action device. The pump, trap, and checkvalve mechanisms shall be incorporated within the same body envelope with no external seals or glands and shall be capable of operating with a minimum of 8 inches installation head from the base of the unit. H E F D C B A G I 8 Spirax Sarco, Inc. 1150 Northpoint Blvd. Blythewood, SC 29016 Tel: (803) 714-2000 Fax: (803) 714-2200 1-800-883-4411 www.spiraxsarco.com/us Printed in USA 4/03 Copyright 2003 Spirax Sarco, Inc.