High challenge warehouse case study Summary

Similar documents
Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

Early Suppression Fast Response Sprinklers and Obstructions

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Today's Topics & Sustainability Themes

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

Tire Storage. Michigan Fire Inspectors Society Fall Conference

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Obstructions and ESFR Sprinklers Phase 1

SPRINKLER TECHNOLOGY:

Ethanol Tank Fire Fighting

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

Plan Submittal Checklist

By: Russell Bainbridge March 18th, 2016 FPE 596

Box-in-Box Cold Storage Fire Protection Options

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Insurance // Property Risk Engineering / GAPS. Dark Warehouses: Loss Prevention, Fire Protection Challenges and Risk Mitigation Measures

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Redlands Fire Department Fire Protection Standard

Evaluation of Protection for Plastic Containers Using Sprinkler Systems with 1.0% AFFF and Plain Water

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

High-Piled Combustible Storage

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

NFPA Edition. NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s. Highlights of 2016 Changes. Storage Commodity Classification 4/29/2014

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

APPENDIX H (DESIGN SUBMISSION CRITERIA)

The Effect of Large Orifice Sprinklers on High-Challenge Fires

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

NTSP 2005 International Telecommunications Safety Conference St. Louis, Missouri September 13-15, 2005

ICC CODE CORNER 2012 IFC Code & Commentary

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Warehouse Protection of Exposed Expanded Group-A Plastics with Electronic Sprinkler Technology

Chapter 17, Initiating Devices

Loss Prevention Standards

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Protection of Storage Under Sloped Ceilings Phase 2 Full Scale Test Matrix

TECHNICAL DATA OBSOLETE

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

esfr pendent sprinkler vk510 (k25.2)

The Science Behind Water Mist Protection of Typical Building Hazards

Storage Sprinkler U.S. Quick Reference Guide

esfr pendent sprinkler vk510 (k25.2)

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

TECHNICAL DATA NOTICE

EMERGENCY VENTILATION FOR SMOKE CONTROL IN ROADWAY TUNNELS (NCHRP PROJECT TASK 363)

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Pro Board Assessment Methodology Matrices for NFPA 1001

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

DEPARTMENT OF DEFENSE HANDBOOK COVERED STORAGE 1. THE FOLLOWING PAGES OF MIL-HDBK-1032/2 HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

FIRE PROTECTION FOR NON-STORAGE OCCUPANCIES WITH HIGH CEILING CLEARANCES

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Soot Mitigation Strategies

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

High Ceiling Protection

Distribution Restriction Statement

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

esfr dry pendent sprinkler Vk502 (k14.0)

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Rooftop Photovoltaic (PV) Systems Examining the Risks and Researching the Options

esfr dry pendent sprinkler Vk501 (k14.0)

Impact of a High Volume Low Speed Fan on Sprinkler Performance in Rack Storage Fires

Mobile Fire Rescue Department Bureau of Fire Prevention

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

TRIPR FLAMMABLE LIQUID UNIT TRAINS

Construction Warehouse. FPE 596 Culminating Experience In Fire Protection Engineering Final Project (Spring 2014) By Ben Johnson

Date of Authorization May 26, 2005 BMEC Authorization BMEC Application # A

Lassen Community College Course Outline

NFPA 30 FLC-SWC Public Comment Report

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

FIRE SAFETY INSPECTION REPORT REDPOINT JACKETS LTD, DHAKA, BANGLADESH

Impact of Supervisory Gas Pressure on Dry Pipe Sprinkler System Water Delivery Time. Steve Wolin Director, Development and Compliance

DUCT SYSTEMS CHAPTER 6

Developing Sprinkler System Design Criteria for Flammable and Combustible Liquid Storage

Transcription:

High challenge warehouse case study Summary February 19, 2010 Richard Gallagher Michael Gollner Zurich Services Corporation

Objectives Review the results of the high challenge warehouse workshop Recognize participants Explain the project background Review case Given information Question Summarize the eight presentations Recap the overall findings

Case study participants Schirmer Engineering Rolf Jensen and Associates FPI Consortium Telgian Summit Fire Protection Hughes Associates UCSD WPI Creative FPE Solutions XL GAPS Dan O Connor, Garner Palenske Richard Bukowski Warde Comeaux Tracy Bellamy Sean Merkel, Ryan Bierwerth Jerry Back, Joe Scheffey, Dan Gottuk Michael Gollner Ali Rangawala Jonathan Perricone John Frank

Background NFPA 13 basis: Automatic sprinklers control or suppression a fire Final fire extinguishment by the fire service Today s warehouses High challenges to both sprinklers and fire service Recent fire experience Not always reasonable to expect manual intervention Foundation Addressing research to support potential changes to NFPA standards.

Workshop approach Basis for workshop Theoretical Case Study Presentations Six leading FPE companies share innovative design concepts One presentation on novel approach to manual fire suppression One presentation addressing need to step back further and understand commodities and storage Format 20 minute presentations Panel Q&A

Case Study Warehouse 2/4/2010 High Challenge Warehouse Case Study 6

General conditions Who - What - Where - XYZ Company New warehouse Rural region of US 2/4/2010 High Challenge Warehouse Case Study 7

Facility parameters Two attached buildings Low Bay 100 x 150 x 35 tall High Bay 55 x 150 x 65 tall 2/4/2010 High Challenge Warehouse Case Study 8

Facility construction Roof Noncombustible steel deck on steel bar joist High bay rack supported roof Exterior walls Insulated metal panel Interior walls Between Low Bay and High Bay 150 long Reinforced concrete block Up to Low Bay roof Floors Reinforced concrete 2/4/2010 High Challenge Warehouse Case Study 9

Public protection Public fire service Volunteer department XYZ Company is first storage facility in district Public water Extending main 3 miles to site Limited flow 60 psi static / 20 psi residual / 800 gpm flowing 2/4/2010 High Challenge Warehouse Case Study 10

Private protection Water supply Two fire pumps one electric, one diesel Ground water suction tank Detached fire pump house 300 feet from building 2/4/2010 High Challenge Warehouse Case Study 11

Storage commodity Group A plastics Unexpanded In cartons Nonencapsulated Conventional wood pallets Pallet loads 4 x 4 x 4 2/4/2010 High Challenge Warehouse Case Study 12

Storage configuration Workshop focus The High Bay warehouse High bay Multiple row rack (4 pallets deep) flanked by double row racks Racks are separated aisles 5 ft wide Array 23 pallets long & 13 pallets high Nominal 6 flues around each pallet load Tiers 5 tall Elevation View 2/4/2010 High Challenge Warehouse Case Study 13

Stock handling Low Bay Industrial trucks High Bay Automatic storage and retrieval system (ASRS) Two ASRS systems Operate in 5 ft wide aisles Photo source: FEMA 2/4/2010 High Challenge Warehouse Case Study 14

The challenge Local fire chief has made it clear that in the event of a fire - Will enter building to save people Will not enter building to save property Question: As the fire protection engineer of record, what fire protection design will be proposed to achieve final fire extinguishment without fire service intervention? Photo source: FEMA 2/4/2010 High Challenge Warehouse Case Study 15

Summary of case study presentations

Summary format Ignition - Sources of ignition Agent - Extinguishing media Detection/ Release - Method of detection and release ASRS - Uses for ASRS Failure - Noted failure concerns for method Comments - Additional comments Where no data provided marked NA and grayed-out

Schirmer Engineering Ignition - Agent - Detection/ Release - ASRS - Failure - Comments - Arson, electrical, etc. Water - ESFR high zone at intersection of flues & over aisles ESFR low zone at intersection of flues One level in-racks in each zone 1600 gpm either zone CO 2 - Horizontal barrier between high and low zones Low zone for redundancy (higher exposure area) Local application, can pipe long distances, can handle flammable liquids and electrical fires, no pumps, Use a 30-60 second discharge Divide low zone into sections (CO 2 volume calculations) Sprinkler fusible element, In-rack linear/spot heat detection NA NA Test ESFR configuration, locate in flues, avoid water ricochet Test low zone detection concept Develop CO2 nozzle Technology proven and can implement today

Rolf Jensen and Associates Ignition - Agent - Detection/ Release - ASRS - Failure - Comments - NA Water mist Zoned vertically (vertical risers) Spray either side of pallet and one side of adjacent pallet High velocity exhaust fans on outside walls - Produce airflow perpendicular to aisles to distribute water mist - Maintain visibility In-rack linear heat detection to locate fire Use self-contained foam skid IR camera guided nozzle Not for primary suppression due to response time NA Low bay is typical for ESFR Critical to maintain longitudinal and transverse flues High bay ceiling sprinklers to protect building

FPI Consortium Ignition - ASRS (lights not usually in use) electrical rails top and bottom, fires involve ASRS unit and spreads to storage Agent - High expansion foam submerge in 4 min 13 foam generators 30 minute duration 100,000 gallons water for 30 minutes Detection/ - Heat detection - ceiling & in-rack spot heat detection Release Ceiling 15 x 15, in-rack 10 vertical & 8 horizontal ASRS - Not used, returned to home base and shutdown Failure - Doors and openings must close False release of foam (cross-zone possible) Comments - Sprinklers not considered due to environment impact

Telgian Ignition - Agent - Detection/ Release - ASRS - Failure - ASRS or lighting at elevated location Water Design an in-rack sprinklers, quick response Need horizontal barriers above in-racks, perhaps each tier Use waterflow to locate fire vertically Fusible sprinkler elements Locate fire using thermal imaging Relocate stock to safe area Handle wet and damaged loads (enclosed unit) NA Comments - Need in-rack sprinkler design guidance - In-rack response time - In-rack water distribution

Summit Fire Protection Ignition - Agent - Detection/ Release - ASRS - Failure - NA Water Develop suppression mode in-racks Increased clearance for larger orifice in-rack sprinklers Fire barriers to provide fire confinement 300,000 gallons 2 hour duration Fusible sprinklers elements Under fire conditions, ASRS not available NA Comments - Introduce ESRF into racks Evaluate all changes over time (personnel turnover, commodities, maintenance, etc.

Hughes Associates Ignition - Agent - Detection/ - Release ASRS - Failure - Comments - NA High expansion foam Zoned system, 4 quadrants, barriers wire mesh/noncombustible fabric Curtains strips to allow ASRS passage Safety factors of 2+ compared to NFPA requirements 20,000 gallons water 30 minute duration In-rack linear heat detection Flame detection for open spaces Apply skid mounted fire suppression system Remove pallets of stock around fire Evaluate extinguishment video monitoring Remove pallets of damaged stock Fire at zone interface, Openings between zones, Collateral damage to stock remote from fire Goals include low complexity, reasonable cost, rapid control, extinguishment, minimum fire damage, and minimum collateral damage

WPI, UCSD, Creative FPE Solutions Ignition - NA Agent - NA Detection Release - NA ASRS - NA Failure - NA Comments - Must start at a more fundamental level Develop method to quantify warehouse fire control, suppression, or extinguishment Limits to modeling and small scale testing Need new intermediate-scale test - Determine water application rate for suppression - Will discuss further in a few slides

XL GAPS Ignition - Agent - Detection/ Release - ASRS - Failure - Comments - NA Water Mobilize remote special fire fighting team Need 12 hours (remote response, size-up, extinguish, overhaul) Sprinklers controlling fire during this time Need 900,000 gallons water Fusible sprinkler elements Fire fighter access to upper tiers NA Interim solution until an engineered solution available Specialized fire team responding from central location Similar to private emergency services such as urban search and rescue, oil wells, oil tanks Skills to verify building stability, locate fire, work vertically, apply agent

Summary of work Ignition scenarios Proposed solutions Design challenges Gaps Manual intervention

Identified ignition scenarios ASRS equipment Lighting Arson Power rails top and bottom Power on stacker crane Can introduce ignition source at any level Ignition exposure at roof Anticipate low level exposure 2/4/2010 High Challenge Warehouse Case Study 27

Solutions Manual fire suppression an immediate solution XL Gaps Test & validate current sprinkler suppression practices WPI, UCSD, Edinburgh, and Creative FPE Solutions. Sprinklers modify current designs ESFR inracks Summit Fire Protection Telgian Sprinklers (2 levels ESFR) & CO 2 Schirmer High expansion foam FPI Consortium Hughes Associates Water mist RJA 2/4/2010 High Challenge Warehouse Case Study 28

Design challenges Water sources Reliability / redundancy Volume / duration Cost of system due to rural location Environmental concerns Release of contaminated water Recycling of used water Hazard of commodity Defining the hazard of a commodity Commodities changing or introducing unknown commodities In-rack sprinkler placement and type (ESFR) highly specific to fuel type, configuration Avoiding complex designs Can collateral damage be limited to limit business impact 2/4/2010 High Challenge Warehouse Case Study 29

Gaps Test methodologies There are no methods, currently, to quantify warehouse fire control, suppression or extinguishment. A test methodology is needed to ensure adequacy of current and new design concepts How much suppressant? Length of discharge? Limitations in full scale, small scale testing and modeling demand a new approach small scale commodity classification verified by intermediate scale testing and large scale modeling/testing for validation

Gaps Design approach WPI et al Determine limits of current sprinkler protection systems Analyze the warehouse fire problem in pieces 1. Characterize sprinkler spray 2. Droplet losses from geometry, plume, radiation, etc. 3. Suppression/Extinction interaction between film/drops and fire Benefits: Design fixed system to provide suppression or extinction for any tested materials Utilize current sprinkler infrastructure and modify deficient systems if necessary Sprinkler Spray PLUME FIRE 2/4/2010 High Challenge Warehouse Case Study 31

Gaps Design approach WPI et al Engineering Approach to Warehouse Fire Protection Design Small Scale Testing Commodity -type classification Intermediate Scale Testing (Proof of concept) Large/Full Scale Modeling (Proof of concept) 32

Gaps Technology In-rack sprinkler design No sprinkler designed to respond quickly in a rack No sprinkler designed to distribute water in a rack No suppression mode in-rack sprinkler Hardening of ASRS for use during fire event Carry self-contained extinguishing system skid Identify fire location within array Verify fire control/suppression progress Remove adjacent stock to isolate fire Remove wet or damaged stock

Gaps Manual intervention - the immediate solution Water supplies Are durations sufficient (2 hours vs. 12 hours) Thorough pre-emergency planning Safe work plan

Questions or comments? 2/4/2010 High Challenge Warehouse Case Study 35