ICARO. Aircraft Warning Lights GENERAL CATALOGUE.

Similar documents
ICARO. Aircraft Warning Lights GENERAL CATALOGUE

ICARO Aircraft Warning Lights

Vigilant LED Based Obstruction Lights

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

Vigilant LED Based Obstruction Lights

AUTOMAX devices for the automation industry

MODULAR AND MULTIFUNCTIONAL SIGNALING DEVICES ENGINEERED FOR CIVIL AND INDUSTRIAL APPLICATIONS MORE THAN BRIGHT IDEAS

D564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant

High-Intensity cd Aviation Light

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

Vigilant LED Based Obstruction Lights

Vehicle Safety & Warning. Product Catalogue (0)

AWL AIRCRAFT WARNING LIGHT MIOL-AC & MIOL-C TYPE OPERATION AND MAINTENANCE MANUAL

FAA RECOMMENDATIONS Marking & Visual Identification of Obstacles

Obstruction Lighting

Dialight Obstruction LED Solutions

LED Ultrastar. trobe beacons

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

signaling solutions from auer signal

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Half-Dome. the Design-Tower. Compact

industrial, safety and security signalling products reference catalogue 2008/9

Flight Crew Reading Lights

Retroreflective sensor with polarization filter

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

XLFE-4/1. Borosilicate glass globe

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Bulletin 855T 70 mm Control Tower Stack Lights

Installation And commissioning manual. Series S Double Beam 1/16

PRODUCT CATALOG HUGHEYANDPHILLIPS.COM

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

REA 105 Arc Protection Module. Operator s Manual

English. Series. Installation and Use Manual

E M E R G E N C Y L I G H T I N G

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

LM40 Medium Intensity Aviation Obstruction Light

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

FAA Obstruction Lighting Buyer s Guide

StreamLine M FEDERAL SIGNAL. One concept. Endless solutions. Safety and Security Systems. A New and Unique. Modular Concept. in Signaling Devices

SHO-ME Lights and Sirens

Airfield lighting. Product Brochure

RLS2000, RLS1000 LED Lighting Systems

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Solution F2. Fire Alarm Control Panels one step ahead.

signaling solutions visual signaling signal towers Audible signaling

Addressable and Conventional Fire Protection

Warning/Hazard Lighting MASTERY STATEMENT:

BEACONS, LIGHTBARS & MINIBARS LED DIRECTIONAL LIGHTS LIGHTING SYSTEMS BACK-UP ALARMS CAMERA SYSTEMS

Updated 04/07/2017 Page 1/8

FLV 40 UV Flame Detector

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

New Beacon Series T & U

Light special. Product special

AV-OL-ILAB-UM-R & AV-OL-FL810-UM-R Universal AC Low Intensity Obstruction Light Installation & Service Manual

Warning Lamps WARNING LAMPS. 10 WELDON PH ( ) FAX " WARNING LAMPS

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Luminaire for traffic coordination Traffic Light Counter 1S2-TL-N Trafic Lider

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

For Complete Fire and Gas Solutions

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

ELLA ID. High CRI, High lm/w OptoDrive LED-module

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

UE/CE DECLARATION OF CONFORMITY

AV-OL-ILAB-12-R & AV-OL-FL R Universal DC Low Intensity Obstruction Light Installation & Service Manual

R.H. Scales Co., Inc. WAREHOUSE DISTRIBUTORS AUTO TRUCK R.V. MARINE R.H. Scales Co. $ 29.95

USER MANUAL OUTDOOR IR ILLUMINATOR

Tower & Obstruction Lighting

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

ENERGY EFFICIENT LED SOLUTIONS

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Obstruction Lighting Guide

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Conventional Fire Detection

AV-OL-ILAB-UM-R & AV-OL-FL810-UM-R Universal AC Low Intensity Obstruction Light Installation & Service Manual

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Optical-Audible Signal Devices

California. Approved LED Products.

VISUAL AND AUDIBLE SIGNALLING DEVICES

ELECTRONIC SOUNDER STROBE Model : AVD-C407

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

MODELR HOUR SOLAR LED FLASHING BEACON REPRESENTED IN YOUR REGION BY: ODOT ITB Section 8: Solar Equipment Item 8-1

AV-OL-IMAB ICAO Medium Intensity Dual Type A & B Obstruction Light Universal DC & Universal AC Models Installation & Service Manual

Passive infrared ceiling sensor

/8 DIN Level Indicator

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

sintra Sintra is a trademark of Asya Traffic INC.

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

SACE PR021/K SIGNALLING UNIT

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Date: 9/28/2016 Initiated By: AAS-100

Transcription:

Aircraft Warning Lights is Sirena s range of high-end Aircraft Warning Lights engineered to last and perform icaro@sirena.it www.icaroawl.com MADE IN ITALY Engineered, Developed and Assembled in Rosta, Italy C.so Moncenisio 5-10-12-14-16 10090 ROSTA (TO) Italia Tel +39.011.95.68.555 (25 linee ISDN) Fax +39.011.95.67.928 www.sirena.it sirena.spa@sirena.it R.E.A. 487901 Mecc. TO 027549 Registro Imprese TO - C.F.01047730013 Partita IVA IT 01047730013 Capitale sociale 5.000.000 di cui versato 5.000.000 8 010152 010453 _ENG_V1.1.0 GENERAL CATALOGUE

Aircraft Warning Lights OUR CONFIGURATOR APPLICATION WILL GUIDE YOU TO SELECT THE BEST AWL SOLUTION FOR YOUR OBSTACLE MARKING NEEDS WEB Version www.icaroawl.com/ webconfigurator ios Version

Aircraft Warning Lights INDEX INTRODUCTION... 2 WARNING LIGHTS AWL 810/AB... 4 AWL 810/AB TWIN... 5 WARNING LIGHTS AWL 864/BC... 6 AWL 864/BC TWIN... 7 AWL 865.866/A... 8 AWL 864+865.6/BC+A... 9 HIGH INTENSITY WARNING LIGHTS AWL 856.857/AB... 10 AWL 856.7+864/AB+BC... 11 CONTROL BOX... 12 ACCESSORIES... 13 SUGGESTED CONFIGURATIONS... 14 VEHICLE WARNING LIGHTS AWL 810/C... 18 FOLLOW-ME BAR... 19 HELIPAD PERIMETER LIGHT AWL HELIX... 20 Index

Aircraft Warning Lights INTRODUCTION S irena designs, engineers and manufactures signaling devices since 1974. From Industrial Signaling Devices to Evacuation Systems, through Aircraft Warning Lights and Automation Devices, our expertise allows to deliver Customers with the highest quality signaling devices available on today s market. With 40 years of intense know-how and a presence in over 60 countries worldwide, Sirena is the best choice when it comes to satisfying your signaling needs. is Sirena s Aircraft Warning Lights range. Engineered entirely on LED base, s Low, Medium and High intensity devices are one of the best products available today. High performance, easy installation and virtually zero maintenance, allow Customers and Installers to add considerable value to their projects. All devices are ICAO and FAA certified as well as CE marked. Our expert Team will guide you to the right choice and will help you to determine the best and most cost efficient solutions for your projects. With a complete range of devices (Low Intensity Type A and B, Medium Intensity Type A, B and C and High Intensity Type A and B), is the complete solution you are looking for. Sirena is ISO 9001, 14001 and 18001 certified. 2 www.icaroawl.com

H IGH INTENSITY High Intensity Aircraft Warning Lights compliant to ICAO Type A, B and FAA L-856, L-857 regulations. 100% LED based, these devices offer a white light with a maximum intensity of 200.000 Cd satisfying the most demanding applications. Typically installed on structures over 150 meters, high intensity devices are used for day and twilight marking. M EDIUM INTENSITY Medium Intensity Aircraft Warning Lights compliant to ICAO Type A, B, C and FAA L-864, L-865, L-866 regulations. 100% LED based, these devices offer a white/red light with a maximum intensity of 20.000 Cd satisfying the most demanding applications. Typically installed on structures over 45 meters, medium intensity devices are used for day, twilight and night marking. L OW INTENSITY Low Intensity Aircraft Warning Lights compliant to ICAO Type A, B and FAA L-810 regulations. 100% LED based, these devices offer a red light with a minimum intensity of 32 Cd satisfying the most common applications. Typically installed on structures below 45 meters and as intermediate devices on taller structures, low intensity devices are used for night marking only. 3

AWL 810/AB AIRCRAFT WARNING LIGHT Low intensity aircraft warning light engineered according to ICAO Low Intensity Type A/B and FAA L-810 regulations. With a lightweight heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with a red steady light, its optical reflector guarantees a 360 horizontal beam radiation and a vertical beam between +6 and +10. Also available with a 70 Cd light intensity output, on-board crepuscular sensor and flashing light option. The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to incandescent bulbs). AL BASE SMD PC DOME CERTIFICATIONS -25 +55 C >32 4W TYPE B IP65 ON 70 10W 70 SELF extinguishing KEY CHARACTERISTICS LED technology Product life >10 years Low consumption Stabilized light output Crepuscular sensor for automatic activation (part no 51045) Beacon-fault report (clean electrical contact) (part no 51045/51046) ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 FAA Advisor Circular AC150/5345-43F TYPICAL APPLICATIONS CRANES BUILDINGS PYLONS WATER TANKS INFRA- STRUCTURES CHIMNEYS WIND TURBINES AIRPORTS INSTALLATION Pole mounting Direct (3/4 NPT-F) Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS 131,5 AWL 810/AB PART NO AWL 810/AB 12/30V DC 51010 AWL 810/AB 70 12/30V DC 51045 crepuscular sensor activated AWL 810/AB 70 12/30V DC 51046 crepuscular sensor not activated PSU 110/240V AC 51011 SIDE BRACKET 51013 D 120 0,60 4

AWL 810/AB TWIN AL BASE PC DOME SMD -25 +55 C >32 TYPE B IP65 5W TWIN BACK-UP CIRCUIT INCLUDED ON TWIN FUNCTION SELF extinguishing TWIN AIRCRAFT WARNING LIGHT Low intensity aircraft warning light engineered according to ICAO Low Intensity Type A/B and FAA L-810 regulations. With a lightweight heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with a red steady light, its optical reflector guarantees a 360 horizontal beam radiation and a vertical beam between +6 and +10. The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to incandescent bulbs). The device is equipped with two separate LED circuits and, thanks to the current sensor installed on board, it automatically switches to the secondary circuit when main fails, with the possibility of sending an alarm signal. KEY CHARACTERISTICS LED technology Product life >10 years Low consumption Stabilized light output Twin operations with the same device (back-up circuit included) CERTIFICATIONS Crepuscular sensor for automatic activation (part no 51014) Beacon-fault report (clean electrical contact) ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 FAA Advisor Circular AC150/5345-43F TYPICAL APPLICATIONS CRANES PYLONS INFRA- STRUCTURES WIND TURBINES INSTALLATION Pole mounting Direct (3/4 NPT-F) Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS 131,5 BUILDINGS WATER TANKS CHIMNEYS AIRPORTS AWL 810/AB TWIN PART NO AWL 810/AB TWIN 12/30V DC 51014 crepuscular sensor activated AWL 810/AB TWIN 12/30V DC 51047 crepuscular sensor not activated PSU 110/240V AC 51011 SIDE BRACKET 51013 0,60 D 120 5

AWL 864/BC AIRCRAFT WARNING LIGHT Medium intensity aircraft warning light engineered according to ICAO Medium Intensity Type B/C and FAA L-864 regulations. With an induced air heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with a steady/flashing red light, its optical lenses guarantee a 360 horizontal beam radiation and a vertical beam of +3. Can be configured to Type B (flashing) or Type C (steady). The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to xenon discharge bulbs). The device is equipped with three spirit balls for perfect installation and can send an alarm signal in case of malfunction. AL PYREX -45 +55 C IP66 ON SELF EXTINGUISHING CONDENSE FREE ENVIRONMENT BASE DOME SMD 2000 9W 54W 1F 20 +/-5 KEY CHARACTERISTICS TYPE B/C TYPE B TYPE C TYPE B LED technology Product life >10 years Low consumption CERTIFICATIONS Stabilized light output Beacon-fault report (clean electrical contact) ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 FAA Advisor Circular AC150/5345-43F TYPICAL APPLICATIONS CRANES BUILDINGS PYLONS WATER TANKS INFRA- STRUCTURES CHIMNEYS WIND TURBINES AIRPORTS INSTALLATION Flat mounting To flat surfaces using the accessory Flat mounter Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS AWL 864/BC PART NO AWL 864/B 20/55V DC 51016 AWL 864/C 20/55V DC 51048 AWL 864/B 240V AC 51017 AWL 864/C 240V AC 51049 FLAT MOUNTER 51031 SIDE BRACKET 51030 225 117 3,7 6

AWL 864/BC TWIN AL BASE SMD PYREX DOME 2000 TYPE B/C CERTIFICATIONS -45 +55 C IP66 ON 9W TYPE B 54W TYPE C SELF EXTINGUISHING ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 FAA Advisor Circular AC150/5345-43F 1F 20 TYPE B TWIN BACK-UP CIRCUIT INCLUDED TWIN FUNCTION CONDENSE FREE ENVIRONMENT TWIN AIRCRAFT WARNING LIGHT Medium intensity aircraft warning light engineered according to ICAO Medium Intensity Type B/C and FAA L-864 regulations. With an induced air heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with a steady/flashing red light, its optical lenses guarantee a 360 horizontal beam radiation and a vertical beam of +3. Can be configured to Type B (flashing) or Type C (steady). The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to xenon discharge bulbs). The device is equipped with two separate LED circuits and, thanks to the current sensor installed on board, it automatically switches to the secondary circuit when main fails, with the possibility of sending an alarm signal. The device is equipped with three spirit balls for perfect installation and can send an alarm signal in case of malfunction. KEY CHARACTERISTICS LED technology Product life >10 years Low consumption Stabilized light output Twin operations with the same device (back-up circuit included) Beacon-fault report (clean electrical contact) TYPICAL APPLICATIONS CRANES BUILDINGS PYLONS WATER TANKS INFRA- STRUCTURES CHIMNEYS WIND TURBINES AIRPORTS INSTALLATION Flat mounting To flat surfaces using the accessory Flat mounter Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS AWL 864/BC TWIN PART NO AWL 864/B TWIN 20/55V DC 51018 AWL 864/C TWIN 20/55V DC 51057 AWL 864/B TWIN 240V AC 51019 AWL 864/C TWIN 240V AC 51058 FLAT MOUNTER 51031 SIDE BRACKET 51030 225 117 4,0 7

AWL 865.866/A AL BASE PYREX DOME SMD 20000-45 +55 C IP66 ON 51W DAY 1F 20 2000 SELF EXTINGUISHING 13W NIGHT CONDENSE FREE ENVIRONMENT 1F 20 AIRCRAFT WARNING LIGHT Medium intensity aircraft warning light engineered according to ICAO Medium Intensity Type A and FAA L-865/L-866 regulations. With an induced air heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with a flashing white light, its optical lenses guarantee a 360 horizontal beam radiation and a vertical beam of +3. The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to xenon discharge bulbs). The device is equipped with three spirit balls for perfect installation and can send an alarm signal in case of malfunction. KEY CHARACTERISTICS LED technology Product life >10 years Low consumption Stabilized light output CERTIFICATIONS Beacon-fault report (clean electrical contact) ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 FAA Advisor Circular AC150/5345-43F TYPICAL APPLICATIONS CRANES BUILDINGS PYLONS WATER TANKS INFRA- STRUCTURES CHIMNEYS WIND TURBINES AIRPORTS INSTALLATION Flat mounting To flat surfaces using the accessory Flat mounter Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS AWL 865.866/A PART NO AWL 865.866/A 20/55V DC 51020 AWL 865.866/A 240V AC 51021 FLAT MOUNTER 51031 SIDE BRACKET 51030 225 117 4,0 8

Medium intensity aircraft warning light engineered according to ICAO Medium Intensity Type A + Type B/C and FAA L-865/L-866 + L-864 regulations. With an induced air heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with both a steady/flashing red light (Type BC) and a flashing white light (Type A), its optical lenses guarantee a 360 horizontal beam radiation and a vertical beam of +3. TYPE A + TYPE BC The device is equipped with three spirit balls for perfect installation and can send an alarm signal in case of malfunction. -45 +55 AL PYREX BASE DOME IP66 C ON SELF EXTINGUISHING CONDENSE FREE ENVIRONMENT TYPE A SMD 20000 KEY CHARACTERISTICS 51W LED technology 1F 20 Product life >10 years DAY TYPE BC Low consumption 2000 9W 54W TYPE B/C TYPE B TYPE C Stabilized light output 1F 20 Dual functionality TYPE B (Type A + Type B/C) Beacon-fault report CERTIFICATIONS ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 (clean electrical contact) INSTALLATION FAA Advisor Circular AC150/5345-43F Flat mounting To flat surfaces using the TYPICAL APPLICATIONS Side mounting To side walls, side poles or accessory Flat mounter side structures using the accessory Side bracket CRANES PYLONS INFRAWIND STRUCTURES TURBINES DRAWINGS, DIMENSIONS AND WEIGHTS BUILDINGS WATER TANKS CHIMNEYS AIRPORTS 180 The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to xenon discharge bulbs). AWL 864+865.866/BC+A PART NO AWL 864+5.6/B+A 20/55V DC 51022 AWL 864+5.6/C+A 20/55V DC 51052 AWL 864+5.6/B+A 240V AC 51023 AWL 864+5.6/C+A 240V AC 51054 FLAT MOUNTER 51031 SIDE BRACKET 51030 6,0 225 AWL 864+865.6/BC+A AIRCRAFT WARNING LIGHT 9

AWL 856.857/AB AL BASE PYREX DOME SMD 200000-45 +55 C IP66 ON 226W DAY 1F 20 SELF EXTINGUISHING 100000 110W TWILIGHT CONDENSE FREE ENVIRONMENT 1F 20 HIGH INTENSITY AIRCRAFT WARNING LIGHT High intensity aircraft warning light engineered according to ICAO High Intensity Type A/B and FAA L-856/L-857 regulations. With an induced air heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. Provided with a flashing white light, its optical lenses guarantee a 120 /360 horizontal beam radiation and a vertical beam of +3 /7. Can be configured to Type A (100.000 Cd twilight use) or Type B (200.000 Cd day use). The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to xenon discharge bulbs). The device is equipped with three spirit balls for perfect installation and can send an alarm signal in case of malfunction. KEY CHARACTERISTICS LED technology Product life >10 years Low consumption Stabilized light output 120 or 360 versions available CERTIFICATIONS Beacon-fault report (clean electrical contact) ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 FAA Advisor Circular AC150/5345-43F TYPICAL APPLICATIONS CRANES PYLONS INFRA- STRUCTURES WIND TURBINES INSTALLATION Flat mounting To flat surfaces using the accessory Flat mounter Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS BUILDINGS WATER TANKS CHIMNEYS AIRPORTS 566 AWL 856.857/AB PART NO AWL 856.857/AB 240V AC (120 ) 51024 AWL 856.857/AB 240V AC (360 ) 51025 FLAT MOUNTER 51031 SIDE BRACKET 51030 225 12,0 10

AWL 856.7+864/AB+BC HIGH+MID INTENSITY AIRCRAFT WARNING LIGHT high + medium intensity aircraft warning light engineered according to ICAO High Intensity Type A/B and FAA L-856/L-857 regulations (high) and ICAO Medium Intensity Type B/C and FAA L-864 regulations (medium). With an induced air heatsink base, this device is the ideal solution for an efficient and long lasting quality obstruction beacon. HIGH Provided with a flashing white light, its optical lenses guarantee a 120 /360 horizontal beam radiation and a vertical beam of +3 /7. Can be configured to Type A (100.000 Cd twilight use) or Type B (200.000 Cd day use). D HI HIGH + MID INTENSITY -45 +55 AL PYREX BASE DOME SMD 200000 1F 20 226W SELF ON IP66 C EXTINGUISHING 100000 110W DAY CONDENSE FREE ENVIRONMENT 1F 20 TWILIGHT 2000 9W 54W TYPE B/C TYPE B TYPE C MEDIUM Provided with a steady/flashing red light, its optical lenses guarantee a 120 /360 horizontal beam radiation and a vertical beam of +3. Can be configured to Type B (flashing) or Type C (steady). The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to xenon discharge bulbs). The device is equipped with three spirit balls for perfect installation and can send an alarm signal in case of malfunction. KEY CHARACTERISTICS 1F 20 +/-5 LED technology TYPE B NIGHT Product life >10 years Low consumption CERTIFICATIONS Stabilized light output 120 or 360 versions available Dual functionality ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 Intensity Type B/C) (High Intensity Type A/B + Mid Beacon-fault report (clean electrical contact) FAA Advisor Circular AC150/5345-43F Flat mounting To flat surfaces using the TYPICAL APPLICATIONS accessory Flat mounter Side mounting To side walls, side poles or side structures using the accessory Side bracket PYLONS INFRASTRUCTURES WIND TURBINES BUILDINGS WATER TANKS CHIMNEYS AIRPORTS DRAWINGS, DIMENSIONS AND WEIGHTS 566 CRANES AWL 856.7+864/AB+BC PART NO AWL 856.7+864/AB+B 240V AC (120 ) 51034 AWL 856.7+864/AB+C 240V AC (120 ) 51059 AWL 856.7+864/AB+B 240V AC (360 ) 51035 AWL 856.7+864/AB+C 240V AC (360 ) 12,0 51060 FLAT MOUNTER 51031 SIDE BRACKET 51030 225 INSTALLATION 11

CONTROL UNITS Image used for illustrative purposes only. Dimensions and content according to selected system KEY CHARACTERISTICS Isolation switch for power supply 230V 50/60 Hz Automatic switch (one for each device) Auto/Man operation switch selector Beacons-fault report available on terminals (clean electrical contacts) Power-on LED indicator Electronic alarms (current relays) Power electronics for beacons feeding Lightning protection OPTIONAL FEATURES GPS synchronization module (simultaneosly flashing) Beacons-fault report available on front panel Crepuscular sensor Temperature control unit CONTROL UNITS PART NO AWL CU LOW INT 12/30V DC 51070 AWL CU LOW INT 110/240V AC 51071 AWL CU MID INT 20/55V DC (max 4) 51063 AWL CU MID INT 20/55V DC (max 8) 51064 AWL CU MID INT 240V AC (max 4) 51061 AWL CU MID INT 240V AC (max 8) 51062 AWL CU HIGH INT 240V AC (120 ) 51026 AWL CU HIGH INT 240V AC (360 ) 51027 AWL CU H+M INT 240V AC (120 ) 51068 AWL CU H+M INT 240V AC (360 ) 51069 AWL CREPUSCULAR SENSOR 51065 AWL GPS SYNC MODULE 51032 AWL TEMPERATURE CONTROL UNIT 51066 AWL FRONT-PANEL FAULT REPORT 51067 CONTROL UNITS Installing multiple signaling devices on the same obstruction structure (pylon, antenna, building, etc.) is defined as System. A central control unit must be used to control all MEDIUM and HIGH INTENSITY systems. A dedicated control unit can be used for multiple installation of LOW INTENSITY devices. The control unit simplifies main operation activities (activation, control of potential anomalies, etc.), as well as possible maintenance procedures. devices can be controlled with a single control unit. devices may require one single unit to control the whole system, according to installation scenarios. HIGH INTENSITY devices require a dedicated control unit in any installation scenarios. Each control unit controls one device only: a system with multiple HIGH INTENSITY devices on the same obstruction structure requires more control units (1:1 ratio), connected in a MASTER/SLAVE network. Control Units for AWL Low Intensity devices can control up to 8 devices Control Units for AWL Medium Intensity devices are available in two versions: - Control Unit for max. 4 AWL Medium Intensity devices - Control Unit for max. 8 AWL Medium Intensity devices HIGH INTENSITY Control Units for AWL High Intensity devices are available in four versions: - Control Unit for 1 AWL High Intensity device 120 - Control Unit for 1 AWL High Intensity device 360 - Control Unit for 1 AWL High Intensity device 120 - Control Unit for 1 AWL High Intensity device 360 SYSTEM DESIGN SUPPORT Our Team of experts can assist designers and installers with professional support in terms of norms and system configuration. icaro@sirena.it 12

ACCESSORIES AWL 810/HELIX (low intensity) 2 MOUNTERS INCLUDED AWL 810/HELIX Ø9 Ø7 1" 3 " 4 1 2 47 " 1 1 2" 2" 90 0,2 AWL 86X/85X 1" AWL 86X/85X (medium + high intensity) Ø9 Ø7 1 2 " FLAT MOUNTER Stainless steel flat mounter, can be used to mount Medium Intensity and High Intensity AWL to flat surfaces 10 250 152 Ø6,5 130 41,5 102 130 74 120 34 11 49 1,4 3 " 4 88 72 107 3 SIDE BRACKETS Stainless steel side mounter, allows lateral mounting to walls, side poles or side structures. Available for AWL 810/HELIX (Low Intensity AWL) and for AWL 86X/85X (Medium and High Intensity AWL) 43 43 3 114,3 66 21,2 AWL 810/HELIX PSU 6 102 1 1 2 " 2" 162 0,7 AWL 810/HELIX PSU 110/240V AC Power Supply Unit for AWL 810 and HELIX devices 120 136 61 115 ACCESSORIES PART NO AWL 86X/85X FLAT MOUNTER 51031 (2 mounters included) AWL 810/HELIX SIDE BRACKET 51013 AWL 86X/85X SIDE BRACKET 51030 AWL 810/HELIX PSU 110/240V AC 51011 0,7 PSU can control up to two AWL 810/AB devices. For AWL 810/AB TWIN and AWL HELIX we recommend using one power supply unit for each device 13

Aircraft Warning Lights SUGGESTED CONFIGURATIONS ELEVATED STRUCTURES <45 m DAY: OFF NIGHT: STEADY RED 14

ELEVATED STRUCTURES <105 m DAY: FLASHING WHITE NIGHT: FLASHING WHITE DAY: FLASHING WHITE NIGHT: FLASHING RED DAY: FLASHING WHITE NIGHT: STEADY RED MAX 52m MAX 52m MAX 52m flashing white Part: AWL 865.866/A flashing red flashing white + flashing red Part: AWL 864+865.6/B+A DAY: OFF NIGHT: FLASHING RED Part: AWL 864/B MEDIUM AND flashing white + Part: AWL 864+865.6/C+A DAY: OFF NIGHT: STEADY RED MARKED NOT MARKED MAX 52m MEDIUM AND 15

ELEVATED STRUCTURES <15O m flashing white Part: AWL 864+865.6/B+A Part: AWL 864+865.6/C+A Part: AWL 864+865.6/B+A Part: AWL 864+865.6/C+A flashing white + flashing red MAX 104m MAX 104m Part: AWL 865.866/A flashing white flashing white + flashing red MAX 104m MAX 104m Part: AWL 865.866/A DAY: OFF NIGHT: FLASHING RED 16 MAX 104m MAX 104m flashing white + MEDIUM AND Part: AWL 864/B Part: AWL 864/B MEDIUM AND DAY: OFF NIGHT: STEADY RED flashing red flashing red flashing white + MARKED DAY: FLASHING WHITE NIGHT: STEADY RED NOT MARKED DAY: FLASHING WHITE NIGHT: FLASHING RED DAY: FLASHING WHITE NIGHT: FLASHING WHITE

ELEVATED STRUCTURES >150 m DAY: FLASHING WHITE NIGHT: FLASHING RED HIGH INTENSITY HIGH + MID INTENSITY HIGH + MID INTENSITY Part: AWL 856.857/AB Part: AWL 856.7+864/AB+B Part: AWL 856.7+864/AB+C flashing white + flashing red MAX 105m flashing white MAX 105m MAX 105m Part: AWL 856.7+864/AB+B flashing white MAX 105m flashing white + steady ed Part: AWL 856.7+864/AB+C Part: AWL 856.7+864/AB+B HIGH + MID INTENSITY flashing white + flashing red Part: AWL 856.857/AB MAX 105m HIGH + MID INTENSITY HIGH INTENSITY flashing white + flashing red Part: AWL 856.857/AB HIGH + MID INTENSITY HIGH INTENSITY HIGH + MID INTENSITY flashing white + Part: AWL 856.7+864/AB+C HIGH INTENSITY HIGH AND HIGH AND DAY: FLASHING WHITE NIGHT: FLASHING WHITE DAY: FLASHING WHITE NIGHT: FLASHING RED DAY: FLASHING WHITE NIGHT: STEADY RED Part: AWL 865.866/A Part: AWL 864+865.6/B+A Part: AWL 864+865.6/C+A flashing white flashing white + flashing red flashing white + Part: AWL 865.866/A Part: AWL 864+865.6/B+A Part: AWL 864+865.6/C+A flashing white flashing white + flashing red flashing white + Part: AWL 865.866/A Part: AWL 864+865.6/B+A Part: AWL 864+865.6/C+A flashing white + flashing red MAX 105m MAX 105m MAX 105m MAX 105m flashing white MAX 105m flashing white + flashing white + MEDIUM AND MARKED MAX 105m flashing white MAX 105m DAY: FLASHING WHITE NIGHT: STEADY RED NOT MARKED DAY: FLASHING WHITE NIGHT: FLASHING WHITE

AWL 810/C AWL 810/C DIN B BASE (FLAT) VEHICLE WARNING LIGHT Low intensity airport vehicle warning light engineered according to ICAO Low Intensity Type C regulations. With a lightweight heatsink base, this device is the ideal solution for an efficient and long lasting quality warning beacon. Provided with a flashing light, its optical reflector guarantees a 360 horizontal beam radiation and a vertical beam between +0 and +12. DIN A BASE (PLUG) The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to incandescent bulbs). Available in amber for use with ground operation vehicles and in blue for use with airport priority vehicles. MAGNETIC BASE KEY CHARACTERISTICS LED technology Product life >10 years Low consumption -30 +50 AL PC BASE DOME C IP66 ON 1,7A 0,8A 12V 24V SELF Stabilized light output extinguishing >40 INSTALLATION Flat mounting Mounting on flat surfaces (DIN B configuration, 3 holes at 120 intervals) Plug mounting Mounting to a DIN A plug Magnetic surfaces. provided base Powering Mounting via cigar on metal plug cable ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 4th Edition, November 2004 Chapter 6 DRAWINGS, DIMENSIONS AND WEIGHTS TYPICAL APPLICATIONS Ø 6 Ø 0 3 1 0 Ø 120 73 74 PRIORITY VEHICLES 121 GROUND OPERATION VEHICLES Ø 120 12 0 12 CERTIFICATIONS Ø 24 AWL 810/C PART NO 18 Ø 148 DIN B BASE (FLAT) 51038 51041 DIN A BASE (PLUG) 51039 51042 MAGNETIC BASE 51040 51043 DIN B BASE (FLAT) DIN A BASE (PLUG) MAGNETIC BASE 0,39 0,53 0,73

FOLLOW-ME BAR FOLLOW-ME BAR VEHICLE WARNING LIGHT Multifunctional light bar available with Xenon (4 linear spotlights) or w LED technology. L Permanent P rear LED display (variable messages). 6 selectable languages (max. 20 m pre-recorded messages for each language p max. 10 personalized messages - 10 m characters). ch FOLLOW-ME BAR FOLLOW-ME BAR offers different options suitable for all types of applications: radio controlled motorized search beam or camera, amber LED parking lights, H3 halogen spotlights. CONTROL UNIT Polycarbonate structure and domes. X -30 +50 PC C IP55 XENON A A ON 130 +/-10 max 1,50 Supplied with remote control console with backlit keys and display (version with message panel). 130 +/-10 LED KEY CHARACTERISTICS VOLTAGE 12V DC max LIGHT EFFECT LED FLASHING EFFECT STROBE: 10 Joules 8,5 XENON LIGHT INTENSITY According to ECE R65 ALSO AVAILABLE Light bars are available in configurations with following options: different PROTECTION GRADE IP55 OPERATING TEMPERATURE -30/+50 C Radio controlled motorized search beam Depth or flood light 55W 120.000 Cd(p) or 100W 150.000 Cd(p) MECHANICAL FEATURES Polycarbonate structure and domes OPTICAL FEATURES Radio controlled motorized camera Fitted with mechanical zoom 22X + 10X digital High sensitivity lens allowing visibility even in dim lit environments Amber parking lights Frontal, side, rear spotlights DRAWINGS AND DIMENSIONS 1060 LED 200 384 CMBE AMBER A Powerful LED or 10 Joules Xenon technology allowing a high intensity flashing effect 382 Steady depth light H3 55W halogen spotlights (frontal - side - amber flashing rear) CERTIFICATIONS e24 3 APPROVAL NUMBERS FOLLOW-ME BAR PART NO PART NOS AVAILABLE ON REQUEST NEW COMPACT (LED FOLLOW-ME BAR) ECE R65 TA1 E3 ECE R65 A1 E3 EMC 2006/28/CE 00 7128 A - e24 NEW COMPACT (XENON FOLLOW-ME BAR) 03 1622 (12V) 00 7007 A 03 1482 (12V) 19

AWL HELIX AWL HELIX HELIPAD PERIMETER LIGHT Low intensity helipad perimeter light. With a lightweight heatsink base, this device is the ideal solution for an efficient and long lasting quality perimeter beacon. Provided with a green steady light, this device has 2 light sources: horizontal and vertical. The horizontal light is equipped with an optical reflector that guarantees a 360 horizontal beam radiation and a vertical beam of +10. The vertical light has a horizontal beam radiation of 360 and a vertical beam of 120. The LED circuit guarantees a long product life estimated in over 10 years, as well as low consumption (1/10 when compared to incandescent bulbs). AL PC -25 +55 C IP65 ON SELF extinguishing BASE DOME SMD >32 5W KEY CHARACTERISTICS LED technology Product life >10 years Low consumption IRRADIATION BEAM Stabilized light output SIDE VIEW VERTICAL IRRADIATION TOP VIEW HORIZONTAL IRRADIATION HORIZONTAL LIGHT = 10 HORIZONTAL LIGHT = 360 VERTICAL LIGHT = 120 VERTICAL LIGHT = 360 CERTIFICATIONS TYPICAL APPLICATIONS INSTALLATION Pole mounting Direct (3/4 NPT-F) Side mounting To side walls, side poles or side structures using the accessory Side bracket DRAWINGS, DIMENSIONS AND WEIGHTS 131,5 HELIPADS 0,60 AWL HELIX PART NO AWL HELIX 12/30V DC 51012 PSU 110/240V AC 51011 SIDE BRACKET 51013 D 120 20

Aircraft Warning Lights OUR CONFIGURATOR APPLICATION WILL GUIDE YOU TO SELECT THE BEST AWL SOLUTION FOR YOUR OBSTACLE MARKING NEEDS WEB Version www.icaroawl.com/ webconfigurator ios Version

Aircraft Warning Lights is Sirena s range of high-end Aircraft Warning Lights engineered to last and perform icaro@sirena.it www.icaroawl.com MADE IN ITALY Engineered, Developed and Assembled in Rosta, Italy C.so Moncenisio 5-10-12-14-16 10090 ROSTA (TO) Italia Tel +39.011.95.68.555 (25 linee ISDN) Fax +39.011.95.67.928 www.sirena.it sirena.spa@sirena.it R.E.A. 487901 Mecc. TO 027549 Registro Imprese TO - C.F.01047730013 Partita IVA IT 01047730013 Capitale sociale 5.000.000 di cui versato 5.000.000 8 010152 010453 _ENG_V1.1.0 GENERAL CATALOGUE