For our present, For their future. Version 11.04

Similar documents
Installation Instructions

Model BX-903, BX-904 and BX-906 Environmental Enclosure For BAM-1020 Operation Manual

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

1ST SUNFLOWER RENEWABLE ENERGY

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

General System Layout Sketch

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

HydroCycle Vertical Aeroponic Systems

General System Layout Sketch

SPLIT WALL-MOUNTED AIR CONDITIONER

INSTALLATION INSTRUCTIONS

569, 570, 571, 572 Series

Installation Manual PS-225 & PS-275

Installation Instructions

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

HX Field Replacement Kit

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Manual PS-200 & PS-201

ENCLOSED PARTS WASHER WITH HEATING SYSTEM ---EPW160-H

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION GUIDELINES

WAILEA OWNER S MANUAL

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Notices for installation

Installation Instructions

[FLARE CONNECTION TYPE] ATTENTION

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Installation Instructions

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

HydroCycle Vertical Aeroponic Systems

e Bath Fan with Light User s Guide

Installation and operating instructions. E.2 Series high efficiency circulator

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

AUTOMATIC GRANULAR ICE FLAKER

569, 570, 571, 572 Series

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Package Content. Decor Star 1 2. PL-011-GS Rev. A

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

e Bath Fan with Light User s Guide

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

INSTALLATION MANUAL Roof Mount Solar Hot Water System

7165 Dust Collector Owner s Manual

Installation Instructions

Installation & Operating Guide

hp Dust Collector With Vacuum Attachment

NATURAL GAS CONVERSION KIT

Installation Instructions

CLe-series Dishwashers

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION. Glass Panel Doors (select models) CAUTION

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

Parts & Material Included

E.2 series high efficiency circulator. Installation and operating instructions

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

CEILING FAN OWNER S MANUAL

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

INSTRUCTION MANUAL Model: SU3022

Installation and Operating Instructions

Turin LED Ceiling Fan

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

5HP CYCLONE DUST COLLECTOR MANUAL

Handshower, Hose & Handshower Accessories

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

Installation manual for room air conditioner

Installation Instructions

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

PolyMax H1-10 Dutch Bucket System

Models , Equinox, and Sirens Clutch Replacement Service Manual

Step 1: Identify the parts of your shade (parts shown are not to scale)

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

Installation Instructions

Privacy Aluminum Shade

ACT Cartridge Dust Collector

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Elite Primer Baldor Series External Pond Pump

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

Manual Parts Washer. Operating Instructions & Warranty Information

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Installation Instructions for. OmniFount

AIR CONDITIONER CASSETTE

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

SAN JUAN FRESH WATER COOLING SYSTEMS

CEILING FAN OWNER'S MANUAL

Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

Nut & Bolt Faucet Installation

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

SERVICING INFORMATION

SAFETY AND OPERATING MANUAL

AquaReef Cube. Inspiring Excellence in Fish Keeping!

Transcription:

For our present, For their future.

SFH-S1 Series Solar Water Heater Assembly Manual Content http://www.sunflower-solar.com/ 1. FEATURES...3 2. SOLAR WATER HEATER SIZE AND WEIGHT...4 3. HOW TO TRANSPORT AND CARRY IT...4 4. NAME OF THE PARTS AND COMPONENTS...4 4.1 THE STRUCTURE OF WHOLE SOLAR WATER HEATER...5 4.2 THE STRUCTURE OF WATER TANK AND CONNECTION...6 5. ASSEMBLY OF THE SOLAR WATER HEATER...7 5.1 ASSEMBLE FRAMES...7 5.1.1 Assemble side parts...7 5.1.2 Assemble the cross bars and connect them...7 5.1.3 Assemble horizontal bars and tie bar-1...8 5.1.4 Assemble tube holder and foot pad...9 5.2 ASSEMBLE THE WATER CYLINDER (WATER TANK)...10 5.3. ASSEMBLE VACUUM TUBES (PLEASE WEAR GLOVES TO PROTECT YOURSELF IN CASE OF A BROKEN TUBE)...11 5.3.1 Loosen the screw of the spiral tight clip so that the spiral tight clip can be opened...11 5.3.2 Insert the glass tubes into the water tank...11 5.4 INSTALL IMMERSION HEATER AND MAGNESIUM BAR (IF YOU BUY THEM FROM US)...13 5.5 INSTALL CONTROLLER (IF YOU BUY IT FROM US)...13 5.6 INSTALL THE SINGLE DIRECTION VALVE...14 5.7 CHECK AND INSPECTION...14 6 LIGHTNING PROTECTION...14 7 PRECAUTIONS...14 8 MAX. WORKING PRESSURE...14 9 INSTALLATION ANGLE...15 10 WIND RESISTANCE AND SNOW ACCUMULATION...15 11 MAINTENANCE REQUIREMENTS...15 11.1 CLEANING...15 11.2 LEAVES...15 11.3 BROKEN TUBE...15 2

Thank you for choosing Sunflower solar water heater. You now have a solar heater with the world s best technology. It has superb performance, is safe and reliable. To get the greatest benefit from your Sunflower solar water heater, please carefully read the User s Manual all the way through before installing and using your solar water heater. Then proceed with your installation and use it according to this manual. Please do not discard your User s Manual. Keep it for later reference. (Note: This manual is exclusively for the Sunflower heat pipe vacuum tube (5818) pressured series solar water heater.) 1. Features 1). Low heat loss: The Sunflower solar water heater has excellent heat insulation using imported, high density, high strength polyurethane foam which is foamed in place under high pressure. 2). Low heat diffusion Heat diffusion at all connections is greatly reduced, virtually eliminating heat losses by convection or conduction, resulting in high heating efficacy. 3). Connections and Valves Connections to the water inlet, outlet, sensor and magnesium rod are all underneath the water tank for easy access. For greater safety, the electrical heater inlet is on the left side to avoid dry burning if not covered by water. Uses a small elbow pipe in the water inlet. By doing this, the cold water will not mix with the hot water so quickly, and the cold water will not flow to the hot water outlet. Uses a P/T valve, Air suction valve and Single direction valve to protect the solar heating system. These valves come with the system. Not all suppliers offer these valves. Refer to Fig 4.2 below. Note: The P/T valve needs to be connected with a pipe and make the pipe outlet face to the ground, if the valve were to open, the pipe directs the water to the ground, not straight out where it might hit someone standing nearby, causing harm and scalding. 4). Easy functional extension: This solar water heater is fitted with a water feed-in connection, overflow connection, connections to level/temperature controls and an electrical element. The user can have a number of options depending on his actual needs. Uses a standard plug for the Connections of sensor and electrical element The Sensor is an accessory to the level/temperature control which is sold together with the level controller, electrical element and water feed-in valve as accessories. 5). The Solar water heater continues to work even if a heat pipe is broken Because each heat pipe works independently, and is inserted into a water tight fitting on the tank, should one or more tubes become broken, the Sunflower solar water heater continues to operate at a somewhat reduced efficiency until the broken heat pipe(s) can be replaced. 3

2. Solar water heater size and weight Specification Size(mm) Item No. Diameter of water tank Qty. of solar tubes Diameter of solar tube Length of solar tube Weight A B C D SFH47155818-S1 Ø 470mm 15pcs Ø 58mm 1.8M 110KG 1458 1228 1594 1655 SFH47185818-S1 Ø 470mm 18pcs Ø 58mm 1.8M 120KG 1701 1471 1594 1655 SFH47205818-S1 Ø 470mm 20pcs Ø 58mm 1.8M 130KG 1863 1633 1594 1655 SFH47245818-S1 Ø 470mm 24pcs Ø 58mm 1.8M 150KG 2187 1957 1594 1655 SFH47305818-S1 Ø 470mm 30pcs Ø 58mm 1.8M 170KG 2673 2443 1594 1655 3. How to transport and carry it Please carry the tank horizontally. It s forbidden to carry it vertically. Please carry the glass tubes carefully and horizontally. It s forbidden to carry them vertically. If you want to transport your solar water heaters a long distance, it s better to put the tank on the bottom and make sure it won t move during transportation. To save space, you can put the tube carton on the tank carton, and do your best to drive carefully, avoiding bumpy road. 4. Name of the parts and components The following is a detailed components list for the Sunflower SFH series solar water heaters. If any parts are missing, please contact the company you bought this heater from at once. 4

4.1 The structure of whole solar water heater http://www.sunflower-solar.com/ No. Name Fig 4.1 Total quantity SFH47*5818 1 15 18 20 24 30 Water tank (with P/T valve & air suction valve & Check valve) 1 1 1 1 1 2 Evacuated tube (Φ58mm*1800mm) 15 18 20 24 30 3 Decoration ring for tube 15 18 20 24 30 4 Black silicon tube cup 15+1 18+1 20+1 24+1 30+1 5 Spiral tight clip 15 18 20 24 30 6 Thermal gel 1 1 1 1 1 7 Screw 1 PKG 1 PKG 1 PKG 1 PKG 1 PKG 8 Gantry 2 2 3 3 3 9 Front bar 2 2 3 3 3 10 Standing bar 2 2 3 3 3 11 Cross bar 2 2 4 4 4 12 Horizontal bar 1 1 2 2 2 13 Tie bar-3 2 2 3 3 3 14 Tie bar-2 2 2 3 3 3 15 Tie bar-1 (length is as No.14, but has cutout on one edge) 2 2 4 4 4 16 Tube holder 1 1 1 1 1 17 Foot pad 4 4 6 6 6 5

SF H 47 * 5818 Diameter and length of tube Tube quantity Diameter of water tank Model (Series) Company logo (Sunflower) 4.2 The structure of water tank and connection Fig 4.2 6

5. Assembly of the solar water heater 5.1 Assemble frames Use the pictures below to help identify the parts needed for each stage of the assembly. 5.1.1 Assemble side parts Use a pair of M8 12 bolts to connect the gantries, front bar, standing bar and tie bar-2, tiebar-3, forming the side piece (SFH155818-S1 and SFH185818-S1 only has two side pieces). You will need a 13mm socket wrench and a 13mm flat wrench to tighten the bolts. 5.1.2 Assemble the cross bars and connect them Join two cross braces through their center hole with a pair of M8 20 bolts. Connect two teams of cross bars to 3 standing bars. 7

5.1.3 Assemble horizontal bars and tie bar-1 Please assemble them by the following steps (as shown). 8

5.1.4 Assemble tube holder and foot pad http://www.sunflower-solar.com/ Join the tube holder to the front bars using M6 X 10 bolts. Join the foot pad to the standing bar and front bar using M6 X 40 bolts. The finished frame Assemble the foot pad, an 11mm socket or wrench is needed Our suggestion: We suggest setting the entire frame up with each leg / foot resting on a paving stone to keep the foot out of water. 9

5.2 Assemble the water cylinder (water tank) Please check the water cylinder and make sure there is nothing inside of it. If there is, please try to take it out. Put the assembled frames on level ground, or install them in their final place of operation, e.g. on the ground or on a roof (If on roof, aerial work, please pay attention to safety). Remove the nuts from the screws at the end of water tank. Then two workers hold onto the two ends of the tank, and put the tank onto the gantry carefully. Please try to let the screws go through the long notch on the gantry. You may need to gently turn the cylinder to achieve it. Then screw the nuts back onto the screws of the tank so that the tank can be fixed on the frame. Note: "Do not tighten the bolts completely. Just make them snug. You may need to turn the tank so that the heat pipe tubes line up with the bottom tube holders. Once the tubes are installed, then tighten the bolts completely so the tank is firmly connected to the stand." 10

5.3. Assemble Vacuum Tubes (Please wear gloves to protect yourself in case of a broken tube) 5.3.1 Loosen the screw of the spiral tight clip so that the spiral tight clip can be opened 5.3.2 Insert the glass tubes into the water tank 1) Carefully unpack the vacuum tube carton. Please take care during the process of inserting the glass tubes, because they can easily be broken and broken tubes can hurt you. Fit a black decoration ring on a tube from the open end with the round side facing down. Slide this 200mm (about 8 inches) down below the top of tube. 2) Daub the thermal silicon grease on the heat exchange end of SFVB solar tube (the copper part), then rotating the pipe, slowly insert the heat exchange end of SFVB solar tube into the water tank 3) Fix the bottom end of SFVB solar tube (the Black silicon tube cup is on the end) on the bottom rail by resting it against the U type notch and securing it with the spiral tight clip; 11

4) Tighten the screw and nut of the spiral tight clip so that it can be closed as a ring. Install the spiral tight clip uses a 7mm socket wrench or flat blade screw driver. Note: Don t screw it too tighten in case of tube broken. 12

5) Repeat steps 2) and 3) to insert the rest of the tubes. When all tubes have been installed and you have tightened all bolts, you are finished with the assembly of the whole SFH integrated pressurized solar water heater. 5.4 Install immersion heater and magnesium bar (If you buy them from us) Install the immersion heater Use a wrench to remove the threaded plug in the immersion heater opening. Wrap the heater pipe threads with at least 2 or 3 windings of Teflon tape. Insert the immersion heater into the hole, being careful not to damage the threads. Hand tightens until snug. Later, after there is water pressure, check for leaks. If need be, using a wrench, tighten the immersion heater another 1/4 turn or until the leak stops, again being careful not to damage the threads or break the immersion heater. If you cannot stop the leak, turn off the water pressure, drain the tank, remove the heater and try the whole procedure again, this time using more windings of Teflon. (Note: The immersion heater is in the left end so it doesn't burn up because of a low water level. If you use the immersion heater, the person who installs the electric heater must be a qualified electrician. You need to use an electricity leakage protection plug and it should be grounded.) Install magnesium bar by the same method 5.5 Install controller (If you buy it from us) Please install controller according to the manual of controller you ve bought. (The person who installs the controller must be a qualified electrician). 13

5.6 Install the single direction valve http://www.sunflower-solar.com/ This valve is added especially for our customers, because not many manufacturers add this valve. Before you install it please wrap Teflon tape and tighten it with wrench. It could protect the water tank and pipe line if the cold water inlet valve is turn off or city water supply is cut off suddenly, because it keeps hot solar heated water from backing up into your house plumbing through the cold water line. Note: For each connector, customers yourselves need to wrap Teflon tape on it to prevent leakage, and make sure that each one is tighten before adding water into the water tank. 5.7 Check and Inspection After you finish the assembly of the solar water heater, please check whether every part is ok, after inspection, please tighten every bolt. Before you turn on water inlet valve, please make sure that every connector is wrapped with Teflon tap and it is tighten. If any leakage, please turn off the water inlet valve and drain the water, wrap more Teflon tap on the leakage connector then install and tighten with wrench. 6 Lightning protection The solar water heater should have lightning protection to avoid lightening damage. A lightning rod is necessary which should be 1.5m higher and 3 m farther away from the solar water heater. For any problems that involve plumbing or electrical connections the services of a qualified professional must be employed. Warning: When in thunderstorm weather please don't use solar water heaters. 7 Precautions 1) When installing your solar water heater in a cold climate where freezing is possible, please put an insulation layer around the pipes which are outside the building. You may want to add additional protection in the form of a thermostatically controlled heat tape. 2) If you use the optional electric immersion heater, the person who installs the electric heater must be a qualified electrician. You need to use an electricity leakage protection plug and everything should be grounded. 8 Max. working pressure This is a pressurized type solar water heater. The maximum working pressure is 6 bar (87PSI). 14

9 Installation angle It is common for solar water heaters to be installed at an angle that is similar to the latitude of your location. Installing it with a tilt angle (as measured from horizontal) less than 20 is not recommended as the heat pipes perform best in the range of 20-70 degrees. While adhering to this guideline, an angle of your latitude +/-10 is acceptable, and will not greatly reduce the solar heater output. Angles out of this range can also be used, but a decrease of heat output will result. When the angle is lower than the latitude, it will increase summer output, while a higher angle will enhance winter output. 10 Wind resistance and snow accumulation When installing the solar water heater, please consider the issue of wind resistance and the resultant stress on the fixed points. The standard frame is designed to withstand wind speeds of up to 100km/h (62 mph) and 30cm (about 11.8 inches) of snow accumulation without damage. For areas with the possibility for high winds, additional reinforcement of attachment points (e.g. into roof rafters, or ground anchors) may be required and can easily be supplied by your local installers. 11 Maintenance Requirements 11.1 Cleaning Regularly raining could keep the heat pipe vacuum tube clean, but if it is particularly dirty then it may need to be cleaned with a soft cloth and warm, soapy water or other glass cleaning solutions. If the tubes are not easily and safely accessible, a water spray from a garden hose may also be used. 11.2 Leaves During autumn, leaves may accumulate between or under the tubes. Please remove these leaves regularly to ensure optimal performance and to prevent any fire hazard. (The solar water heater will not cause the ignition of flammable materials). 11.3 Broken Tube If one heat pipe vacuum tube is broken, please don t worry, the system will still work. You just need to replace the broken tube. It is very easy. Follow the instructions in step 5.3.2. 15