REA 105 Arc Protection Module. Operator s Manual

Similar documents
1. General Safety Block diagram Description of operation Connections Commissioning...11

Annunciator Unit SACO 16 D1. Product Guide

Annunciator unit. Application

VAMP 121. Arc protection unit. User manual

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Analog Annunciator Unit SACO 16 A3. Product Guide

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAMP 120 & 121. Arc flash detection units. Product picture

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

SENTINEL D - Fault Passage Monitoring

SPEF 3A2 C. Fault indicator. User s manual and Technical description SPEF 3A2 C. f n SPA. Serial port. RS AA Ser.No.

Universal fault annunciator for panel mounting

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Panel Mounted Fault Annunciator Series

Instructions for the fan motor control system, SILVER C

SENTINEL A - Fault Passage Indicator

Panel Mounted Fault Annunciator Series

UV Flame Supervision System

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

RE-PR3-E-27 3-Phase Panel Mount 27kW

Operation and use. Functions and characteristics

AO Annunciator Module

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Rules for Classification and Construction Additional Rules and Guidelines

Audible warning devices for external alarm

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Window facia fault annunciators

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

DIGITIAL PROTECTION COUPLER

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

M2500 Engine Controller Installation Manual

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

AQ 100 Series. Arc Flash Protection System

Soft Starter Centrifugal Pump Soft Starter Series

Type TEC, Transformer Electronic Control System

Fisher LCP100 Local Control Panel

User Guide

Overload relays. General descriptions. Configuration of the front

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Scope of functions 32 VAR 51/37 64 DC 64 R

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Snifter ATEX22 VERSION. User Manual. Distributor

CHECKFIRE 210 Detection and Actuation System

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

C-Bus Four Channel Analogue Output Unit Installation Instructions

Operating Manual MS220KA and MSR220KA

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

for relative humidity and temperature with calibration certificates

E-17 Flammable Gas Detection and Alarm System

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Delta XRD. Supervision Relays. rms A U X I L I A R Y T R I P P I N G S U P E R V I S I O N

ME 3011C / Alarm Indication / Quick Reference Guide

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

LC2200 Level Controller Installation and Maintenance Instructions

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

D1000 Arc-fault Protection System

Digital Heater Element Burnout Detector K8AC-H

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

Operating Manual TR600

Ordering Key. Dielectric strength

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

MSM - Expansion modules

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

LC3000 Level Controller Installation and Maintenance Instructions

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Laser Distance Sensor Type M Analog-Output

MR3CCUHV Temperature/Defrost Control

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

INTERNATIONAL STANDARD

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Installation, Operating and Maintenance Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Transcription:

REA 105

1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5 3. Block diagram...6 4. Operation description...7 4.1. Light detection...7 4.2. Trip output...7 4.3. Operation of IN1 and OUT1 ports...8 4.4. Operation of port IN2...8 4.5. Circuit-breaker failure protection...8 4.6. Self-supervision unit (IRF)...9 4.7. Front panel...9 4.8. Functions of LEDs and switches...10 5. Connections...12 6. Commissioning...13 6.1. Instructions for commissioning:...13 6.2. Testing of arc protection system level...13 6.3. Light reference setting...13 7. Dimensions and fixing...15 8. Technical data...16 9. Order information...18 9.1. Extension unit...18 9.2. Pre-manufactured sensor fibres...18 9.3. Accessories for manufacturing sensor fibres...18 9.4. Connection cables...18 10.References...19 11.Index...20 ABB Automation 3

REA 105 1MRS 751005-MUM 1. General The REA 105 is an extension unit designed to be used together with the arc protection relay REA 101. The function of the unit is to detect light and to carry out tripping, if the REA 101 unit provides an overcurrent signal at the same time, or delivers a trip command. The use of extension units allows the protection area to be extended and the protected object to be divided into smaller areas. Thus a more selectove system is obtained. 1.1. Features Loop-type or radial sensor fibre for arc detection. 2 high-speed semi-conductor outputs for tripping. Signal relay activated by light detected by the sensor fibre. 3 RJ45 ports for the connection of REA 101 relay and extension units. Circuit-breaker failure protection. Delayed light signal to REA 101, which opens the higher-level circuit breaker. Self-supervision unit monitoring operating voltages and the sensor fibre loop. 4 ABB Automation

1MRS 751005-MUM REA 105 2. Safety! National and local electrical safety regulations must always be followed. Dangerous voltages can occur on the connectors, even though the auxiliary voltage is disconnected. The frame of the units has to be carefully earthed. Only a competent electrician is allowed to carry out the electrical installation. Sensor fibres have to be handled according to the instructions given by the sensor fibre manufacturer. Settings and configuration changes have to be done with the auxiliary supply voltage (U aux ) disconnected. Malfunction may occur if changes are made with the supply voltage connected. ABB Automation 5

REA 105 1MRS 751005-MUM 3. Block diagram HSO2 HSO1 X4 1 2 3 6 7 9 10 IN sensor 1 OUT SG1/ 4 SG1/ 3 Light detection and testing SG1/ 8 light SG1/ 6 7 SG1/ 7 6 Circuitbreaker failure protection SG1/ 1 SG1/ 5 & PORT IN 1 PORT OUT 1 X1 X2 Cable connection block SG1/ 2 trip I> Power PORT IN 2 X3 Cable connection block I> trip loh5a )LJ 5($EORFNGLDJUDP 6 ABB Automation

1MRS 751005-MUM REA 105 4. Operation description 4.1. Light detection The switch SG1/4 (Sensor ON/OFF) is used for selecting the sensor fibre. The light captured by the sensor fibre is amplified and compared either to an automatic or a manual reference level. Once the reference level has been exceeded, a light signal is generated and the signal relay (Light) is activated for about 0.5 seconds. In a trip situation, the central unit REA 101 or the REA 105 unit itself provides information about the tripping, and the signal relay is locked in the active state. If no tripping occurs, the relay resets. The SG1/3 switch (Automatic light ref. level ON/OFF) is used for selecting the automatic or manual reference level. The unit itself forms the automatic reference level according to the present backlight intensity measured by the sensor fibre. The potentiometer Light Ref. Level Adj. on the front panel is used for setting the manual reference level. The sensor fibre is monitored by sending a test pulse through the fibre. Unless the test pulse is received at regular time intervals at the other end of the loop, the sensor fault LED Fault and the IRF indicator LED IRF are activated. Condition monitoring of the sensor fibre can be deactivated with the switch SG1/8 (Sensor supervision deactivation ON/OFF), in which case a radial i.e. a terminating fibre can be used. When the switch SG1/5 (Light to port IN1 ON/OFF) is in the OFF position, no light signal is transmitted to the REA 101 unit located in the direction of the port IN1, and the REA 105 extension unit alone carries out tripping if the REA 101 unit delivers an overcurrent signal at the same time. When the switch SG1/5 is in the ON position, the light signal is transmitted to the central unit REA 101. Both the REA 105 and the REA 101 unit trip if the overcurrent signal is active. Delayed tripping by REA 101 is explained in Circuit-breaker failure protection. The REA 105 unit does not send a light signal to the port IN2. 4.2. Trip output The trip output contains two high-speed, galvanically isolated IGBT semi-conductor outputs (HSO1 and HSO2). These outputs can be used in DC and AC circuits. The control signal of the outputs is activated if the unit detects light and the central unit REA 101 delivers an overcurrent signal, provided the operating voltage fault signal is inactive. Once the central unit REA 101 performs tripping, all the REA 105 extension units connected to it trip as well. When the REA 105 trips, the outputs remain in an active state. The outputs are reset by pressing the Reset push-button or via the RESET input of the central unit. ABB Automation 7

REA 105 1MRS 751005-MUM 4.3. Operation of IN1 and OUT1 ports 4.4. Operation of port IN2 The ports IN1 and OUT1 are connected in parallel. The connection cable from the central unit REA 101 is connected to the port IN1 and the connection cable to the next extension unit departs from the port OUT1. A maximum of five extension units, one after the other, can be linked to one port of the central unit. The terminator of the last extension unit has to be connected using the switch SG1/ 1: Terminator 1 ON/OFF. This allows the REA 101 unit to monitor the condition of the connection cable. Should the terminator be unconnected, the fault indicating LED Port A/B Fault of the central unit REA 101 and the IRF indicator LED IRF are activated, and the IRF relay resets. The REA 105 extension unit gets the operating voltage over the port IN1. Port IN2 is used when the ports of two REA 101 units are to be connected together, for instance, for the transfer of overcurrent signals. (See sections Functions of LEDs and switches and Application examples of the REA 101 Operator s manual 1MRS 751003-MUM. In this case, the ports must be terminated, that is, the terminators for both ports IN1 and IN2 have to be connected (switches SG1/1-2). The port is galvanically isolated from the rest of the device, because otherwise possible potential differences between the central units might cause problems. 4.5. Circuit-breaker failure protection The circuit-breaker failure protection is implemented by delaying the light signal that is transmitted to the bus via the IN1 port. The switch SG1/6 (Delayed light to port IN1 ON/OFF) is used to activate the circuitbreaker failure protection. When the circuit-breaker failure protection is in use, the switch SG1/5 (Light to port IN1 ON/OFF) has to be in the OFF position. The desired delay time, 100 ms or 150 ms, is selected with the switch SG1/7 (Delay ON = 150 ms, OFF = 100 ms). Once the REA 105 unit trips the delay time starts running. If the overcurrent signal is active when the delay time runs out, the REA 105 extension unit transfers a light signal to the port IN1 and delayed tripping will be carried out by the REA 101 unit. Should the overcurrent signal disappear during the time delay, no light signal will be transmitted by the REA 105 unit, and no delayed tripping will be performed by the REA 101 relay. 8 ABB Automation

1MRS 751005-MUM REA 105 4.6. Self-supervision unit (IRF) In addition to that mentioned above, the self-supervision unit monitors the operating voltages of the device. If a fault is detected in the operating voltages, the selfsupervision unit prevents the device from operating. When the LED indicator IRF of the REA 105 unit is lit, the port fault LED Port A/B Fault of the REA 101 relay starts flashing, the LED indicator IRF is activated and the IRF relay resets. 4.7. Front panel X1 Port IN1 X2 Port OUT1 X3 Port IN2 10 ~ + ~ - 9 7 6 ~ + ~ - X4 3 2 1 HSO1 HSO2 Light SG1 1 = Terminator 1 ON/OFF 2 = Terminator 2 ON/OFF 3 = Automatic light ref level ON/OFF 4 = Sensor ON/OFF 5 = Light to port IN1 ON/OFF 6 = Delayed light to port IN1 ON/OFF 7 = Delay ON = 150 ms, OFF = 100 ms 8 = Sensor supervision deactivation ON/OFF ABB Network Partner REA 105 ARC PROTECTION 1MRS090418-AA Ser. No 5 2 Light ref. level adj. ON MAX SG1 MIN OFF Light Fault Sensor OUT IN TRIP IRF Uaux paneli5 )LJ )URQWSDQHO ABB Automation 9

REA 105 1MRS 751005-MUM 4.8. Functions of LEDs and switches LEDs activated: U aux Light TRIP IRF Fault + IRF Power supply is connected The sensor fibre has detected light The unit has tripped The self-supervision system has detected a fault (The fault LED Port A/B Fault of the REA 101 relay is flashing, the IRF indicator is lit, and the IRF relay has reset) Sensor fibre broken (The sensor fibre may still detect light between the sensor input and the breakage) Transmitter/transceiver is defective Light Ref. Level Adj.: Potentiometer for manual backlight compensation: - potentiometer in use, if switch SG1/3 in OFF position. - potentiometer not in use, if switch SG1/3 in ON position. Switchgroup SG1: 1. Switch 1 (Terminator IN1 ON/OFF) Switch in ON position: Terminator IN1 connected 2. Switch 2 (Terminator IN2 ON/OFF) Switch in ON position: Terminator IN2 connected 3. Switch 3 (Automatic light ref. level ON/OFF) Switch in ON position: Automatic backlight compensation selected (Potentiometer Light Ref. Level Adj. not in use) Switch in OFF position: Manual backlight compensation selected (Potentiometer Light Ref. Level Adj. in use) 4. Switch 4 (Sensor ON/OFF) Switch in ON position: The sensor fibre is used for arc detection 5. Switch 5 (Light to port IN1 ON/OFF) Switch in ON position: A light signal detected by the REA 105 is transmitted to the REA 101 unit linked to the port IN1. (When the REA 101 unit trips, the REA 105 extension units connected to it trip as well.) Switch in OFF position: No light signal is transmitted to the port IN1. 6. Switch 6 (Delayed light to port IN1 ON/OFF) Switch in ON position: Circuit-breaker failure protection in use. The selected time delay (SG1/7) is started by the tripping of the REA 105 unit. If the overcurrent signal is still active when the time delay elapses, the REA 105 unit transmits a light signal to the higher-level REA 101 unit linked to the port IN1. Switch in OFF position: No delayed light signal is transmitted to the port IN1. 10 ABB Automation

1MRS 751005-MUM REA 105 7. Switch 7 (Delay ON = 150 ms, OFF = 100 ms) This switch is only used together with the circuit-breaker failure protection (SG1/6 in ON position) Switch in ON position: Delay = 150 ms Switch in OFF position: Delay = 100 ms 8. Switch 8 (Sensor supervision deactivation ON/OFF) Switch in ON position: Sensor fibre loop condition monitoring not in use, i.e. a radial fibre may be used Switch in OFF position: Sensor fibre loop condition monitoring in use. ABB Automation 11

REA 105 1MRS 751005-MUM 5. Connections Connection ports: X1 Port IN1 X2 Port OUT1 X3 Port IN2 Connector X4: 1 Light common Signal relay of sensor 2 Light /NC Signal relay of sensor 3 Light /NO Signal relay of sensor 4 Not in use 5 Not in use 6 HSO2 -(~) Heavy-duty high-speed semi-conductor output 2 7 HSO2 +(~) Heavy-duty high-speed semi-conductor output 2 8 Not in use 9 HSO1 -(~) Heavy-duty high-speed semi-conductor output 1 10 HSO1 +(~) Heavy-duty high-speed semi-conductor output 1 Sensor fibre connectors: Sensor OUT Sensor IN 12 ABB Automation

1MRS 751005-MUM REA 105 6. Commissioning 6.1. Instructions for commissioning: The following procedure should be followed when the unit is commissioned: All switch settings have to be made before the auxiliary voltage of the unit is connected. 1 Switchgroup SG1: Default setting: SG1= 0000000 Set the switches as required by the application. See sections Function of LEDs and switches in this manual and Application examples of the REA 101 Operator s manual 1MRS 751003-MUM. Terminator: Check that the terminator of the last extension unit of each extension unit chain is connected, i.e. switch SG1/1 is in position ON. In some applications switch SG1/2 is set in position ON, too. 3 Potentiometer Light Ref. Level Adj: Default setting: middle position. If the SG1/3 switch is set for automatic backlight compensation, the setting of the potentiometer does not have to be changed. 6.2. Testing of arc protection system level Check the current measurement function of each REA 101 relay by measuring the primary or secondary circuit. When the current limit is exceeded, the I> Start LED of the concerned is lit. 2 Turn the Trip Condition key switch into position Light to check that overcurrent data is transmitted through the entire system arrangement, as required by the application. Check that the LED I>Start of the concerned REA 101 units is lit. Finally, turn the Trip Condition key switch into position I> & Light. 5 Check each REA 101 relay included in the application in the same way. 6.3. Light reference setting Set the lighting level as close to normal work conditions as possible. Turn the Light Ref. Level Adj. potentiometer until the Light LED is lit or goes out. Turn the potentiometer one scale mark interval to the right. Should the Light LED remain dark, even though the potentiometer is in the Min. position, the potentiometer can either be left in this position or turned one scale mark interval to the right, depending on the sensitivity level desired. ABB Automation 13

REA 105 1MRS 751005-MUM Turn the key switch Trip Condition of one REA 101 relay into position Light. Expose one sensor fibre at a time to light, for example using a flash, and check that the right circuit breakers operate. When all of the sensor fibres have been tested, set the Trip Condition key switch/key switches as required by the application. N.B. The 7ULS&RQGLWLRQ key switch always has to be in an extreme position. 14 ABB Automation

1MRS 751005-MUM REA 105 7. Dimensions and fixing ø 5.0 170.3 203.3 160.5 182.6 )LJ 'LPHQVLRQV dim105 49.6 170.3 160.5 ass103 )LJ )L[LQJPHWKRGV Fixing method recommended: Method 1: M4 threaded hole, fixing with M4 machine screw. Method 2: φ 4.2 mm hole, fixing with M4 machine screw and a nut. ABB Automation 15

REA 105 1MRS 751005-MUM 8. Technical data Table 8.-1 Signal contacts (Light) Maximum system voltage Continuous carry Make and carry for 0.5 s Make and carry for 3 s Breaking capacity for dc, when the control circuit time constant L/R <40 ms, at 48/110/220 V dc 250 V dc/ac 5 A 10 A 8 A 1 A/0.25 A/0.15 A Table 8.-2 Outputs Trip contacts HSO1 and HSO2 Maximum system voltage Continuous carry Make and carry for 0.5 s Make and carry for 3 s Breaking capacity for dc, when the control circuit time constant L/R <40 ms, at 48/110/220 V dc 250 V dc/ac 1.0 A 30 A 15 A 5 A/3 A/1 A Table 8.-3 Power consumption (operating voltage over the port of REA 101) Under quiescent conditions/maximum ~2.7 W/~3.7 W N.B. Maximum 5 extension units can be linked to one port of REA 101 Table 8.-4 Sensor fibre Maximum length without splices or with one splice Maximum length with two splices Maximum length with three splices Service temperature range Minimum permissible bending radius 60 m 50 m 40 m -35...+80 C 50 mm Table 8.-5 Connection cable Maximum length 50 m Table 8.-6 Total operate time HSO1 and HSO2 <2.5 ms Table 8.-7 Environmental tests Specified service temperature range -10...+55 C Transport and storage temperature range -40...+70 C Dry heat test Acc. to IEC 60068-2-2 Dry cold test Acc. to IEC 60068-2-1 Damp heat test cyclic Acc. to IEC 60068-2-30 r.h. >95%, t = 20...55 C Storage temperature test Acc. to IEC 60068-2-48 16 ABB Automation

1MRS 751005-MUM REA 105 Table 8.-8 Standard tests Insulation tests CE approval Dielectric test IEC 60255-5 Impulse voltage test IEC 60255-5 Insulation resistance measurements IEC 60255-5 Test voltage Test voltage 2 kv, 50 Hz, 1 min 5 kv, unipolar impulses, waveform 1.2/50 µs, source energy 0.5 J >100 MW, 500 Vdc Mechanical tests Vibration tests (sinusoidal) IEC 60255-21-1, class 1 Shock and bump test IEC 60255-21-2, class 1 Table 8.-9 Electromagnetic compatibility tests The EMC immunity test level fulfills the requirements listed below 1 MHz burst disturbance test, common mode 2.5 kv class III, IEC 255-22-1 differential mode 1 kv Electrostatic discharge test, contact discharge 6 kv class III air discharge 8 kv IEC 61000-4-2 and 60255-22-2 Radio frequency interference test conducted, common mode IEC 61000-4-6 radiated, amplitude modulated IEC 61000-4-3 Fast transient disturbance test IEC60255-22-4 and 4 kv IEC 61000-4-4 Surge immunity test IEC 61000-4-5: - trip outputs common mode 4 kv differential mode 2 kv - signal output contacts common mode 2 kv differential mode 1 kv Electromagnetic emission tests EN 55011 and EN 50081-2 Table 8.-10 Enclosure Degree of protection, IEC 60529 IP 20 Weight ~1.1 kg radiated RF emission 10 V/m (rms) f = 150 khz...80 MHz 10 V/m (rms) f = 80...1000 MHz EN 55011, class A Complies with the EMC directive 89/336/EEC and the LV directive 73/23/EEC. ABB Automation 17

REA 105 1MRS 751005-MUM 9. Order information 9.1. Extension unit Arc protection unit REA105 1MRS090418-AA 9.2. Pre-manufactured sensor fibres Length: Order number: 5 m ± 3% 1MRS120512.005 10 m ± 3% 1MRS120512.010 15 m ± 3% 1MRS120512.015 20 m ± 3% 1MRS120512.020 25 m ± 3% 1MRS120512.025 30 m ± 3% 1MRS120512.030 40 m ± 3% 1MRS120512.040 50 m ± 3% 1MRS120512.050 60 m ± 3% 1MRS120512.060 ST splice adapter SYJ-ZBC 1A2 9.3. Accessories for manufacturing sensor fibres Sensor fibre 100 m Sensor fibre 300 m Sensor fibre 500 m ST connector ST fibre termination kit 9.4. Connection cables 1MSC380018.100 1MSC380018.300 1MSC380018.500 SYJ-ZBC 1A1 1MSC990016 5 m ± 3% 1MRS120511.005 10 m ± 3% 1MRS120511.010 15 m ± 3% 1MRS120511.015 20 m ± 3% 1MRS120511.020 30 m ± 3% 1MRS120511.030 40 m ± 3% 1MRS120511.040 50 m ± 3% 1MRS120511.050 18 ABB Automation

1MRS 751005-MUM REA 105 10. References REA10_ Technical Overview Brochure 1MRS 750929-MBG REA101 1MRS 751003-MUM REA103 1MRS 751004-MUM ABB Automation 19

REA 105 1MRS 751005-MUM 11. Index A Accessories 16 active state 6 Arc protection 16 arc protection relay 3 automatic reference level 6 B backlight compensation 8 backlight intensity 6 C CE approval 15 Condition monitoring 6 Connection cable 14, 16 Connection ports 10 Connector X4 10 Connectors of sensor fibre 10 current limit 11 current measurement function 11 D Degree of protection 14 delay time 7 Delayed light 7 Delayed tripping 6, 7 E Electromagnetic compatibility tests 15 Enclosure 14 Extension unit 16 F Fault alarm 4 fault indicating LED 7 fixing 13 frame 4 G galvanically isolated 7 H higher-level circuit breaker 3 HSO1 6 HSO2 6 I 20 ABB Automation

1MRS 751005-MUM REA 105 Insulation tests 15 IRF indicator LED 6, 7 IRF relay 7 L LEDs activated 8 Light 6 Light Ref. Level Adj. 8 Light reference setting 11 light signal 6, 7 lighting level 11 M manual reference level 6 Mechanical tests 15 N Environmental tests 14 O operating voltage fault signal 6 operating voltages 3, 7 Order information 16 Outputs 14 overcurrent data 11 overcurrent signal 3, 6, 7 P port fault LED 7 Potentiometer 6, 8, 11 Power consumption 14 R reference level 6 References 17 reset 6 RESET input 6 Reset push-button 6 S selecting the sensor fibre 6 Self-supervision unit 3, 7 sensitivity 11 sensor fault LED 6 Sensor fibre 6, 12, 14 sensor fibre loop 3 Signal contacts 14 signal relay 6 Switchgroup SG1 9, 11 T ABB Automation 21

REA 105 1MRS 751005-MUM Terminator 7, 11 Testing 11 Total operate times 14 trip situation 6 W Weight 14 22 ABB Automation

ABB Substation Automation Oy P.O. Box 699 FIN-65101 VAASA Finland Tel. +358 10 224 000 Fax. +358 10 224 1094 www.abb.fi 1MRS 751005-MUM EN 05.2000