Connection of auxiliary heater in coolant circuit of W12 engine

Similar documents
The advantages of the 4-valve technology

Dash panel insert. Display symbol. Designation/definition symbol. Electronic immobiliser Lamp comes on when unauthorised car key is used

SECTION AUXILIARY HEATER

Troubleshooting and Repair Instructions. Eberspächer. The Troubleshooting and Repair Instructions are applicable to the following unit versions

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

A WORLD OF COMFORT. The troubleshooting and repair instructions are only valid. Heaters for petrol B 5 S 12 V

The troubleshooting and repair instructions are only valid. Heaters for petrol B 4 S 12 V B 5 S 12 V

Anti-theft alarm system E63/E64. VS-22 es Baugruppe/Group: 65 10/ (061) Introduction

- 12 VDC. HHE M - 12 VDC.

OWNER S MANUAL. Rev. C

Original operating instructions Safety switch with guard locking AC901S AC902S

Repair instructions A WORLD OF COMFORT. Spare parts list. The repair instructions are valid for the following

HEATING. Additional heating

AHE S -12 VDC AHE S - 24 VDC

EVANS TEMPCON DASH HEATER A/C All Electric Control Systems

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

HYDRONIC L-II Troubleshooting and Repair Instructions

Troubleshooting and Repair Instructions

HEATER, AIR CONDITIONING AND VENTILATION

PORTABLE ENGINE HEATER AND EXTERNAL BATTERY CHARGER. Specifications: Benefits: IN: NC:

FLAME AMPLIFIER MODULE 3001

COR'IAIR HEATER CONTENTS. SERlJICIN8. the PART II DESCRIPTION AND OPERATION

HEATING AND VENTILATION

HEATING SYSTEMS. Thermo plus 230 Thermo plus 300 Thermo plus 350. Thermo plus Rail. Workshop Manual. Rev. 04/2018 Id.No B

Power Flame Incorporated

AIRTRONIC * AIRTRONIC D4. Operating Instructions and Service Book

Thermo 230 / 231 / 300 / 301 / Troubleshooting

SNUGGER SNUGGER AIR HEATER AIR SNUGGER USA Technical description. Installation instructions. Operating instructions

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

Hydronic 4/5 (Coolant Heaters)

WELCH INDUSTRIES - PAGE 1 OF 5

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

ELECTRONIC AIR CONDITIONING CONTROL

Product Support Bulletin

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

Hybernator. Espar Heater Systems. Installation Instructions Operating Instructions. Rail Mount P/N

List of Contents. 1.5 Legal Provisions for Installation Corrections and Improvements Combustion Air Fan Assembly...

Repair Shop Manual. Air Heaters. Air Top 2000 Diagnosis. Air Top Type AT 2000 B (Fuel) Type AT 2000 D (Diesel)

Settings and Maintenance of the CombinAir

Thermo 50 Coolant Heater. HMMWV 6.2 and 6.5 Liter Diesel. Table of Contents. Foreword

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Burner control unit BCU 370


! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Thermo H 160 Thermo H 230 Thermo H 300 Thermo H 350

Air Top 3500 Air Top 5000

Operating instructions

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Operating instructions

AIRTRONIC L Technical description, installation, operation and maintenance instructions.

Airtronic D2 / D4 / D4+ Operating Instructions and Service Book

Kenworth Professional. Workbook No. 2, 2007 Volume 80. Featuring: Kenworth Clean Power System. See page 8 for details.

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

List of Contents. 1.1 Scope and Purpose

Burner control unit BCU 370

Thermo 90 Thermo 90-ADR Thermo 90 S Thermo 90 S-ADR

B. Section Transfer Switches: Automatic transfer switch.

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Sensaphone 400 Telemetry System Integration

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Direct Gas-Fired Make-Up Air

HEATER, AIR CONDITIONER AND VENTILATION

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

Coolant Heater. Thermo Installation Instructions for use with The Detroit Diesel Series 4000 Engine

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

EuroVan No. 81/1. Auxiliary Heater B3LC/D3LC, Wiring diagram. from September Edition 10/98 USA

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

AIRTRONIC / AIRTRONIC M

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

AIR-HEATER FOR VEHICLES

SNUGGER CANADA Snugger Heaters Unit B-1465 Kebet Way Port Coquitlam, BC V3C 6L

TECHNICAL DESCRIPTION, INSTALLATION, OPERATING, TROUBLESHOOTING, REPAIR AND MAINTENANCE INSTRUCTIONS - HYDRONIC II 5E, HYDRONIC II.

DIESEL/PARAFFIN HEATERS

USER'S INFORMATION MANUAL

7-Day Electronic Timer Model CDN Operating Instructions

Thermo 50. Workshop Manual. Water heaters. Type Thermo 50 (Diesel/PME) 09/1999

PARAFFIN/DIESEL HEATER

Corn Flame Energy Corn Stove Model 3000

Climate Control. Service Training Course No. 701

AIRTRONIC L Technical description, installation, operation and maintenance instructions.

System Installation. multi-zone heating

Hydronic D5 (Chevy Duramax Application)

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

WATER-HEATER FOR VEHICLES

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Security System. User Guide for the LED Command Center

Figure 10 or Figure 6

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

CLOTHES DRYER Technical Information

D3LC compact Air Heater. Espar. Installation Troubleshooting & Parts Manual. D3LC compact

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

installation & operating instructions

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Installation & Operating Instructions

Transcription:

Coolant circuit Connection of auxiliary heater in coolant circuit of W12 engine If the auxiliary heater is started when the engine is switched off, the coolant shutoff valve closes. The recirculating pump pumps coolant through the coolant jacket in the auxiliary heater to the pump valve unit, then through the heat exchanger inside the vehicle and back to the auxiliary heater. The vehicle interior is heated. Coolant circuit Gearbox oil cooler Engine oil cooler Alternator C Cylinder block Coolant shutoff valve N279 26

Function When voltage is applied to the shutoff valve, coolant can flow from the pump valve unit to the heater. When there is no voltage at the shutoff valve, coolant can flow from the pump valve unit to the engine. Radiator Continued coolant circulation pump V51 Air reservoir Thermostat Expansion tank Right heat exchanger Left heat exchanger Pump valve unit Recirculating pump V55 Auxiliary heater S280_015 The pump valve unit is part of the vehicle heater and is described in SSP 271. 27

Coolant circuit Connection of auxiliary heater in coolant circuit of V10 TDI engine On the supplementary heater there is no coolant shutoff valve. The heater is permanently connected to the engine coolant circuit. Coolant circuit Check valve Continued coolant circulation pump V51 Fuel cooling pump V166 Low temperature cooler for alternator and fuel cooling Radiator 28

Expansion tank Right heat exchanger Left heat exchanger Pump valve unit S280_052 Recirculating pump V55 Supplementary heater 29

Function Air supply The air required for combustion is drawn via the combustion air intake from the combustion air blower and passed through the combustion air channel to the combustion chamber. Combustion air blower V6 Coolant outlet Combustion air inlet Combustion air channel Recirculating pump V55 Fuel channel Coolant inlet Fuel evaporator Exhaust pipe Metering pump V54 Heater glow plug Q9 (with flame monitor) 30

The fuel supply Fuel is supplied through the fuel channel. In the fuel evaporator (fleece), fuel is mixed with the combustion air, forming a combustible fuel-air mixture. The glow plug with flame monitor ignites the mixture in the combustion chamber at the start. Once operation has begun, ignition occurs at the flame front in the flame pipe. During operation of the heater, the glow plug Q9 is supplied with only a small amount of energy from the control unit. The electrical resistance of the glow plug can thus be used as a flame monitor. Flame pipe Combustion chamber in burner housing Coolant jacket The coolant Coolant enters through the coolant inlet in the coolant jacket. Here, it is heated. The heated coolant flows out the coolant outlet into the coolant circuit. S280_010 31

Operating stages The auxiliary heater Start phase The auxiliary heater is started either: - immediately, - via the timer or - using the remote control. The combustion air blower and the recirculating pump are actuated. The glow plug starts to glow and the combustion air blower pumps air into the burner insert. After about 30 seconds, the metering pump starts to deliver fuel and the combustion air blower is switched off for about 5 seconds until a rich mixture has built up. The output of the combustion air blower is increased in stages to full load and the fuel-air mixture is delivered to the combustion chamber. Combustion begins. If no flame is formed or the flame dies, restart is initiated automatically. After a total of 90 seconds of fuel delivery without flame formation, the system is switched off until the ignition is switched on again (terminal 15). Start Preglow Start of combustion Full load operation Fresh air blower Part load Full load Part load Shutoff Start of run-on End of run-on Recirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blower Temperature in C 90 85 80 75 70 5 Time in seconds 30 90 S280_036 32

Heating phase/regulated phase When the coolant reaches a temperature of 87 C, the heater is switched from full load to part load. This reduces the combustion air blower output and the metering pump delivers less fuel. If the coolant temperature drops to approx. 83 C, full load is activated again. At a coolant temperature of approx. 89 C, heating is interrupted. When the coolant temperature drops to approx. 85 C, heating is initiated once again. Start Preglow Start of combustion Full load operation Fresh air blower Part load Full load Part load Shutoff Start of run-on End of run-on Recirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blower Temperature in C 90 85 80 75 70 S280_037 33

Operating phases Run-on phase The auxiliary heater is deactivated by: - switching off the engine, - switching off the auxiliary heater or - expiration of the automatic heating duration (max. 60 minutes). Run-on time depends on the type of heater and can be between 100 and 175 seconds. The run-on time for petrol-driven heaters is: 168 seconds when switched off from full load 157 seconds when switched off from part load The metering pump is switched off, combustion stops, the combustion air blower and the recirculating pump run-on to cool down and are then switched off automatically. The run-on time for diesel-driven heaters is: 175 seconds when switched off from full load 100 seconds when switched off from part load There may be slight deviations in the given figures depending on the development of the software. Start Preglow Start of combustion Full load operation Fresh air blower Part load Full load Part load Shutoff Start of run-on End of run-on Recirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blower Temperature in C 85 80 70 60 50 S280_038 Time in seconds 100-175 34

The supplementary heater (diesel engines) Start phase When the engine is started, the heater is made ready. When the coolant temperature is below 60 C, ambient temperature is below + 5 C and the control unit has received an engine speed signal, start is initiated. Heating phase If the coolant reaches 78 C, operation is interrupted. When the coolant temperature reaches 76 C, full load operation is switched to part load. The transition from part load to full load comes at 70 C and to part load at 65 C. Run-on phase When the engine is switched off, the supplementary heater is stopped. Combustion is stopped and run-on begins. The supplementary heater run-on time is: 175 seconds when switched off from full-load 100 seconds when switched off from part-load There may be slight deviations in the given figures depending on the software version. Start Preglow Start of combustion Full load operation Fresh air blower Part load Full load Part load Shutoff Start of run-on End of run-on Recirculating pump Glow plug Combustion air blower VL Combustion air blower TL Metering pump VL Metering pump TL Flame monitor interrogation Fresh air blower Temperature in C 80 75 70 60 50 S280_020 Time in seconds 100-175 35

Deactivation Deactivation conditions The auxiliary heater and the supplementary heater are switched off for reasons of safety under certain conditions. Vehicle-specific deactivation The auxiliary heater is switched off when: - the tank flap is opened, - the fuel level is low, - the onboard electrical system is placed under heavy load by the onboard electrical system control unit, - an airbag is triggered by an accident - heater output is sufficient during normal driving. S280_024 Temperature related deactivation If the coolant temperature rises above 105 C during heater operation, fuel supply is interrupted. In this instance, the heater will run-on for approx. 120 seconds. If there is a fault in the combustion air blower, there will be no run-on. Deactivation Heater operation S280_028 36

Deactivation due to excessive or insufficient voltage In addition to monitoring of the onboard electrical system voltage by the onboard electrical system control unit, the auxiliary heater control unit also deactivates the heater if excessive or insufficient voltage is detected. Heater operation Deactivation Fixed deactivation due to insufficient voltage If the battery voltage drops to below 9.5 volts for longer than 6 seconds, the heater is deactivated with a run-on time of 120 seconds. S280_029 Deactivation due to excessive voltage If the battery voltage exceeds 15.5 volts for more than 60 seconds, the auxiliary heater is deactivated. 37

Networking Communication via CAN data bus The auxiliary heater control unit is connected with the other control units in the vehicle via the infotainment CAN data bus and the diagnosis data bus interface in the dash panel. All the necessary information can be exchanged with other control units via this data network. Roof electronics control unit J528 Climatronic/air conditioning control unit J301 Control unit for front information display and operating unit Onboard electrical supply control unit J519 Climatronic operating and control unit E265 Entry and start authorisation control unit J518 Door control unit, driver side J386 38

Control unit for front information display and control unit J523 Data bus diagnosis interface J533 in dash panel Auxiliary heater control unit J255 Data bus diagnosis interface Drive train CAN data bus Convenience CAN data bus Infotainment CAN data bus S280_034 39

Networking The data bus messages A) Function B) Message Auxiliary heater messages received from remote commands and from modes of operation Activation via remote control Activation of blower Activation of control LED Commands and information to auxiliary heater control unit Terminal information Auxiliary heater operation Auxiliary heater operation Programming of auxiliary heater Activation of auxiliary heater Tank warning on Convenience CAN data bus messages Ignition on Operating commands e.g. auxiliary ventilation e.g. immediate start Auxiliary heater operating mode Heating duration Start time Actuation of auxiliary heater Auxiliary heater operating mode Auxiliary heater duration information Auxiliary heater duration Heater deactivation Tank flap opened Heater deactivation Onboard electrical system critical battery level Heater deactivation Crash impact signal Status information Engine speed Ambient temperature Engine type 40

C) Sender D) Receiver Auxiliary heater control unit Control unit with display unit in dash panel insert Control unit with display unit in dash panel insert Climatronic/air conditioning control unit Roof electronics control unit Entry and start authorisation control unit Onboard electrical supply control unit Control unit for front information display and operating unit Climatronic/air conditioning operating and display unit Additional water heater control unit Control unit with display unit in dash panel insert Control unit with display unit in dash panel insert Auxiliary coolant heater control unit Auxiliary heater control unit Climatronic/air conditioning control unit Control unit for front information display and operating unit Control unit with display unit in dash panel insert Control unit for front information display and operating unit Control unit with display unit in dash panel insert Climatronic/air conditioning control unit Control unit with display unit in dash panel insert Climatronic/air conditioning operating and display unit Control unit with display unit in dash panel insert Control unit for front information display and operating unit Climatronic/air conditioning control unit Door control unit, driver side Control unit with display unit in dash panel insert Onboard electrical supply control unit Control unit with display unit in dash panel insert Control unit with display unit in dash panel insert on receipt of message from airbag control unit Auxiliary heater control unit Control unit with display unit in dash panel insert Additional coolant heater control unit 41

Functional diagram Key A Battery G241 Coolant temperature sender, heater J255 Auxiliary heater control unit on auxiliary heater J285 Control unit with display unit in dash panel insert J533 Data bus diagnosis interface N279 Coolant shutoff valve, heater Q9 R11 Heater glow plug Q9 (with flame monitor) Aerial R149 Auxiliary heater remote receiver, beneath rear shelf S Fuse V6 Combustion air blower V54 Metering pump V55 Recirculating pump Y Analogue clock A V54 V55 Signal output Earth Signal output Positive Infotainment CAN data bus 42

J285 J533 Y G241 Q9 R11 J255 R149 V6 N279 S280_043 43

Service Diagnosis Diagnosis can be carried out using the testing and diagnosis system VAS 5051. Communication is via the diagnosis interface. The exchange of data between the diagnosis system and the diagnosis interface in the dash panel insert is via the COM lead. Continued exchange of data is via the infotainment CAN data bus. If the data bus is defective or the data bus diagnosis interface is defective, diagnosis is not possible. A description of the individual diagnosis functions can be found in the guided fault finding program on the testing and diagnosis system VAS 5051. These are accessed automatically. The following components are monitored by the diagnosis system: Auxiliary heater control unit Combustion air blower Glow plug Metering pump Coolant shutoff valve Recirculating pump Additionally, the power supply and data bus communication are checked and any faults are stored in the fault memory. Testing and diagnosis system VAS 5051 44

Combustion air blower Glow plug Data bus diagnosis interface Metering pump Recirculating pump Shutoff valve S280_018 45

Glossary Diagnosis interface The diagnosis interface is a virtual control unit in the dash panel insert. It transmits CAN data bus messages from one CAN data bus to the next and also transmits data from the COM lead to the CAN data bus lines Loose belt The distance between the seat belt and the upper body (thorax). The heavier the clothing, the greater the distance between upper body and seat belt. This distance has to be balanced by the belt tensioner in a collision. Degree of efficiency The relationship between the energy supplied and energy returned. The chemical energy stored in the fuel is converted partly into mechanical energy and thereby into kinetic energy. The remaining energy ends up as heat, exhaust gas and radiant energy. 46

47

Test yourself 1. The auxiliary heater is activated a) automatically when the ignition is switched on. b) by the on/off switch in the driver's door. c) by the immediate start function in the information display and operating unit. 2. The fixed start time is programmed a) by the timer preselection in the front information display and operating unit. b) by the preselection clock in the driver's door. c) by the analogue clock setting in the dash panel insert. 3. Remote start a) is initiated by dialing telephone number 0800 89 73 74 23 and giving the start time to the centre. b) is initiated by pressing the start button on the remote control. c) is initiated by pressing the open button on the ignition key. 4. When the engine is not running, the auxiliary heater heats a) the engine. b) the interior via the pump valve unit and the left and right heat exchangers. c) the interior via the pump valve unit and the left and right heat exchangers, the luggage compartment and the engine. 48

5. In the start phase of auxiliary heating a) the combustion air blower is switched off for 5 seconds so that a rich mixture is created. b) the metering pump is increased to 150 % delivery so that a rich mixture is created. c) the combustion air blower delivers more air to create a leaner mixture. 6. The auxiliary heater is switched off if a) during the start phase there is no independent flame. b) the coolant temperature rises above 105 C. c) the battery voltage is less than 9.5 volts for six seconds. 7. The auxiliary heater control unit a) communicates with other control units in the vehicle via the drive train CAN data bus. a) communicates with other control units in the vehicle via the convenience CAN data bus. c) communicates with other control units in the vehicle via the infotainment CAN data bus and data bus diagnosis interface in the dash panel insert. Answers 1c; 2a; 3b; 4b; 5a; 6a,b,c; 7c; 49

50 Notes

51

280 For internal use only VOLKSWAGEN AG, Wolfsburg All rights and the right to make technical alterations reserved 240.2810.99.20 Technical status 02/03 This paper was manufactured from pulp that was bleached without the use of chlorine.