Innovative Lighting R-Series Vertical Refrigeration

Similar documents
Innovative Lighting R-Series Overhead LED Conversion Kits

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

EcoBrite Smooth Light LED Light Fixtures

Innovative Lighting Smooth Light Recessed Luminaires

Cold Door 2 LED Retrofit Kit Lighting System

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Honeywell Durafit LED Retrofit Kit

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

INSTALLATION INSTRUCTIONS

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Dioluce Products Installation Instructions

HPNLS-LO. Installation Manual

1 General Description

LED IMPORTANT SAFETY INSTRUCTIONS

1 x4 Dimmable LED RetroFits

INSTALLATION INSTRUCTIONS

OWNER S MANUAL & WARRANTY

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

MaxLite LED Vapor Tight Linear Fixture

LED IMPORTANT SAFETY INSTRUCTIONS

LED Flat Panel Retrofit

HPNLS-RT. Installation Manual

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Installation Instructions

e Bath Fan with Light User s Guide

Installation Instructions

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

e Bath Fan with Light User s Guide

MaxLite LED Round Pendant Highbay Series

e Heater/Exhaust Fan/Light User s Guide

VENTILATION FAN / LED LIGHT

Murano Shower Cabin Installation Instruction

DHL-LP-LED Low Profile LED Linear High/Low Bay

LED IMPORTANT SAFETY INSTRUCTIONS

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

e Bath Fan with Light User s Guide

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Item no PERSONAL V2.0. User s Manual

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Forteza Series Granite Kitchen Sink

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

LED IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

LED IMPORTANT SAFETY INSTRUCTIONS

ELSTON 52 CEILING FAN

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

APPUZO RANGE HOOD INSTALLATION

Product Identification

Model: EF34. Owner's Guide & Installation Manual

ELECTRIC STOVE HEATER Models: FS2213B

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

WARNING Important Safety Information

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

OPERATING INSTRUCTIONS

HP-SUBMERSIBLE. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

ST. KITTS CEILING FAN

WARNING Important Safety Information

ASSEMBLY AND DRESSING INSTRUCTIONS

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

SUTTON 52 CEILING FAN

WARNING Important Safety Information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

IMPORTANT SAFETY INFORMATION:

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

INSTRUCTIONS FOR OPERATION AND CARE OF

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

TOUCHDOWN 48 CEILING FAN

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

Panel Mounted Heat Exchangers by Dantherm, Inc.

Ozone + UV Sanitation

1PIECE FREESTANDING BATHTUB

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Use and Care Manual VERONA 32 OM 16 GAUGE STAINLESS STEEL SINGLE BOWL OVERMOUNT SINK ZUHNE

HUMIDITY SENSING BATH FAN

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Model NT20e Installation Guide

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

MaxLite LED High Bay Fixtures

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

CCS-100. Installation Manual

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

Transcription:

Installation Guide Innovative Lighting R-Series Vertical Refrigeration Door LED Conversionn Kits For Commercial Refrigerators and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow these instructions will invalidate the warranty on this product. WARNING Risk of fire or electrical shock. Disconnect power before installing or servicing product. CAUTION Use caution when handling a power tool. Always wear protective eyewear. Save these instructions for reference R-Series Vertical Refrigeration Door LED Conversion Kits Installation Guide, Rev. 1.0, Date: 09/19/13

Innovative Lighting R-Series Vertical Refrigeration Door LED Conversion Kits allow commercial refrigerators and freezers to be converted to using energy efficient Innovative Lighting LED lighting systems. Kits include two or more vertical LED light fixtures, low voltage power supplies, and mounting clips. The vertical LED light fixtures are completely assembled modules that can be mounted in the same location as the existing light source. Innovative Lighting R-Series Vertical LED Light Fixtures are available in models for both installation in the center of a refrigerated case, between two doors (750/751 Series), and installation at the end of a refrigerated case, next to a single door (733/734 Series). Kits include both right side (73Z-50XX-1) and left side (73Z-50XX-1A) end models. R-Series Vertical LED Light Fixture Center Model (750/751 Series) R-Series Vertical End Light LED Light Fixture End Model (733/734 Series) Mounting Clip WARNING Risk of fire or electric shock. Innovative Lighting R-Series Vertical Refrigeration Door LED Conversion Kits are only intended for use in replacing existing light fixtures in Listed commercial refrigerators and freezers having the construction features shown in the photographs and/or drawings. 2

Several Innovative Lighting R-Series Vertical Refrigeration Door LED Conversion Kits are available. See the kit description below for LED light fixture length and quantity. Verify the contents of the conversion kit before installation. 1 Door Vertical Refrigeration Door LED Conversion Kit - 75Y-50XX-4 (1) Vertical End Light Fixture - Right (PN 73Z-50XX-1) (1) Vertical End Light Fixture - Left (PN 73Z-50XX-1A) (1) 12VDC Class 2 Power Supply (PN 750-9995-1) (4) Mounting Clips (PN 730-9910-1) 2 Door Vertical Refrigeration Door LED Conversion Kit - 75Y-50XX-4-2 (1) Center Vertical Light Fixture (PN 75Y-50XX-1) (1) Vertical End Light Fixture - Right (PN 73Z-50XX-1) (1) Vertical End Light Fixture - Left (PN 73Z-50XX-1A) (1) 12VDC Class 2 Power Supply (PN 750-9995-1) (6) Mounting Clips (PN 730-9910-1) Required tools and components Tape Measure Pencil Power Drill Screwdriver Bit or Standard Screwdriver 1/8 Drill Bit Wire Stripper Electrical Tape or Cable Ties Listed Wire Nuts or Other Listed Connectors #8 Sheet Metal Screws 3 Door Vertical Refrigeration Door LED Conversion Kit - 75Y-50XX-4-3 (2) Center Vertical Light Fixture (PN 75Y-50XX-1) (1) Vertical End Light Fixture - Right (PN 73Z-50XX-1) (1) Vertical End Light Fixture - Left (PN 73Z-50XX-1A) (2) 12VDC Class 2 Power Supply (PN 750-9995-1) (8) Mounting Clips (PN 730-9910-1) 4 Door Vertical Refrigeration Door LED Conversion Kit - 75Y-50XX-4-4 (3) Center Vertical Light Fixture (PN 75Y-50XX-1) (1) Vertical End Light Fixture - Right (PN 73Z-50XX-1) (1) Vertical End Light Fixture - Left (PN 73Z-50XX-1A) (2) 12VDC Class 2 Power Supply (PN 750-9995-1) (10) Mounting Clips (PN 730-9910-1) 5 Door Vertical Refrigeration Door LED Conversion Kit - 75Y-50XX-4-5 (4) Center Vertical Light Fixture (PN 75Y-50XX-1) (1) Vertical End Light Fixture - Right (PN 73Z-50XX-1) (1) Vertical End Light Fixture - Left (PN 73Z-50XX-1A) (2) 12VDC Class 2 Power Supply (PN 750-9995-1) (12) Mounting Clips (PN 730-9910-1) 5 Door 6 Vertical Refrigeration Door LED Conversion Kit 750-5072-4-5 (4) Center Vertical Light Fixture (PN 750-5072-1) (1) Vertical End Light Fixture - Right (PN 733-5072-1) (1) Vertical End Light Fixture - Left (PN 733-5072-1A) (3) 12VDC Class 2 Power Supply (PN 750-9995-1) (12) Mounting Clips (PN 730-9910-1) Where: XX indicates the length of the included light fixtures in inches (60 = 5, 72 = 6 ). Y indicates the power level of the conversion kit and center light fixtures (0 = standard power, 1 = low power). Z indicates the power level of the end light fixtures (3 = standard power, 4 = low power). Note that standard power conversion kits use 750 and 733 Series fixtures, while low power conversion kits use 751 and 734 Series fixtures. See the R-Series 750/751 and R-Series 733/734 specification sheets for information on differences between the standard and low power models. 3

WARNING Risk of fire or electric shock. Innovative Lighting R-Series Vertical Refrigeration Door LED Conversion Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a licensed electrician. WARNING Innovative Lighting R-Series Vertical Refrigeration Door LED Conversion Kits are for use in converting commercial refrigerators and freezers supplied by 110VAC or 240VAC only. Do not use with commercial refrigerators or freezers supplied by 277VAC. Removal of Existing Components: 1. TURN OFF POWER TO THE COMMERCIAL REFRIGERATOR OR FREEZERR AT THE SERVICE PANEL AND FOLLOW APPROPRIATE LOCK OUT / TAG OUT SAFETY PROCEDURES. DO NOT ATTEMPT INSTALLATION UNTIL IT IS VERIFIED THAT THE POWER IS OFF. 2. Remove the existing light sources, such as fluorescent lamps, from the refrigerator or freezer. Properly dispose of these after installing the conversion kit. 3. Disconnect the lampholders from their wiring. 4. Open the covers of the electrical raceways enclosing the ballasts and their associated primary and secondary wiring. These are typically located below the doors, running the length of the refrigerator or freezer, or in the mullions between the doors. 5. Disconnect the wiring from the ballasts and remove the ballasts from the electrical raceways along with the secondary wiring. 4

WARNING Risk of fire or electric shock. Prior to drilling, ensure that there are no components behind the mounting surface in the areas marked off for the mounting holes. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. Installation of New Components: 6. When installing Innovative Lighting R-Series Vertical LED Light Fixtures, the power cable should exit the top of the light fixture. The lenses in the light fixture use a lap joint that prevents moisture from getting into the light fixture when oriented with the cable exiting the top of the fixture. 7. When installing Innovative Lighting R-Series Vertical End Light LED Light Fixtures, make sure the light fixtures are oriented as shown below for proper light distribution: 8. Inspect the location where a new Innovative Lighting R-Series Vertical LED Light Fixture is to be installed and determine the location of the mounting clips. One mounting clip (PN 730-9910-1) should be installed approximately 12 inches from each end of each vertical LED light fixture. Use a pencil to mark the pilot holes for the mounting clips. 5

9. Drill a 1/8 diameter pilot hole into the mounting surface at each of the marks made in step 8 and attach the mounting clips with #8 sheet metal screws in the pilot holes. See figure below: 10. Snap the back side of the vertical LED light fixture into the mounting clips as shown in the following figure: 6

All wiring must be in compliance with NEC and local codes. This light fixture is suitable for damp locations. When used in a damp location, ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. 11. Each Innovative Lighting R-Series Vertical Refrigeration Door LED Conversionn Kit comes with the appropriate number of regulated 12VDC Class 2 power supplies (PN 750-9995-1) for the vertical LED light fixtures that come with that kit. Each power supply has an output of 12VDC and can support up to a 5A load when supplied by a 100-240VAC input. Each regulated 12VDC Class 2 power supply should be placed in a location previously occupied by one of the ballasts. Secure each power supply using #8 sheet metal screws through the mounting holes at the ends of each power supply. One regulated 12VDC Class 2 power supply will drive the following combinations of R-Series Vertical LED Light Fixtures : (2) Vertical End Light Fixtures (1) Vertical End Light Fixture and (1) Center Vertical Light Fixture (2) Vertical End Light Fixtures and (1) Center Vertical Light Fixture (2) Center Vertical Light Fixtures (1) Vertical End Light Fixture and (2) Center Vertical Light Fixtures (except for (1) 734-5072-1 Vertical End Light Fixture and (2) 750-5072-1 Center Vertical Light Fixtures these cannot be driven from a single power supply) 12. Connect the AC input wires of each regulated 12VDC Class 2 power supply to the AC primary wires previously connected to the input of the ballast. Use UL Listed wire nuts, quick disconnect connectors, or other Listed connectors following the connector manufacturer s instructions. Terminate any unused AC primary wires with a UL Listed wire nut or other Listed connector so that they are not exposed. Regulated 12VDC Class 2 Power Supply Primary Side Connections: Black wire - Connect to AC Line wire. White wire - Connect to AC Neutral wire. 13. Run new secondary wiring through the electrical raceways between each regulated 12VDC Class 2 power supply and the Innovative Lighting R-Series Vertical LED Light Fixtures that it is intended to power. Connect the DC output wires of each regulated 12VDC Class 2 power supply to the new secondary wires using a UL Listed wire nut or other Listed connector. Regulated 12VDC Class 2 Power Supply Secondary Side Connections: Red wire - Connect to positive (+) secondary wire. Blue wire - Connect to negative (-) secondary wire. Each regulated 12VDC Class 2 power supply should be connected as shown: 7

14. Connect the input wires of each R-Series Vertical LED Light Fixture to the new secondary wires that have been run to the light fixture through the electrical raceways using UL Listed wire nuts or other Listed connectors. R-Series Vertical LED Light Fixture Input Wire Connections: Red wire - Connect to positive (+) secondary wire. Blue wire - Connect to negative (-) secondary wire. Optional Linear Dimming Control: An optional 0-10V dimming module may be installed between the regulated 12VDC Class 2 power supply and the R-Series Vertical LED Light Fixtures to provide linear dimming. Dimming modules sold separately. Optional Occupancy Sensor Control: An optional power pack may be installed before the regulated 12VDC Class 2 power supply for controlling the R-Series Vertical LED Light Fixtures with an occupancy sensor or other control input. Power packs and occupancy sensors sold separately. 15. Gather any slack wires and secure them together with electrical tape or cable ties. 16. Close the covers of the electrical raceways. Be sure no wires are pinched or touch sharp edges and all high voltage AC primary wiring is enclosed within the electrical raceways. 17. Place the label stating that the original luminaire has been modified near the light fixtures where it will be readily visible during normal maintenance. This label is included with the conversion kit. 18. Turn the power back on to the commercial refrigerator or freezer at the service panel and verify that all R-Series Vertical LED Light Fixtures are powered and operating properly. 8

Removal If an R-Series Vertical LED Light Fixture needs to be removed, place a standard screwdriver between the rail and the side of the mounting clip. Gently press the screwdriver handle towards the light to release. Do this for both clips. Refer to the image below. Cleaning If an R-Series Vertical LED Light Fixture requires cleaning, follow the procedure below. - Switch off or disconnect the power to the R-Series Vertical LED Light Fixture. - Remove the R-Series Vertical LED Light Fixture from the mounting clips if necessary. - Wipe surfaces with a clean, soft cloth lightly dampened in a mixture of warm water and mild dish soap. - Wipe surfaces again with a - Dry all surfaces completely - Reattach the light fixture to clean, soft cloth lightly dampened in warm water. with a clean, soft cloth. the mounting clips and switch on/reconnect power. Do not use abrasive cleaners, scouring pads, or paper towels to clean or dry the lamp. Do not use bleach, alcohol, or other chemicals to clean the lamp. Some chemicals and abrasive products may scratch and damage the surfaces. Do not submerge the lamp or use overly wet cloths as it may cause damage to internal electrical components. CANADIAN INSTALLATIONS: THE RETROFIT KIT IS ACCEPTABLE AS A COMPONENT OF A LUMINAIRE WHEREE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. Save these instructions for reference 9

This page intentionally left blank 10

Purchase Date: Warranty Expiration Date: Thank you for your purchase of an Innovative Lighting R-Series Vertical Refrigeration Door LED Conversion Kit. Please keep the top portion of this page for your records and mail the bottom portion to the address provided to register your product. WARRANTY INFORMATION Innovative Lighting LLC., Limited Product Warranty is FIVE (5) YEARS from date of purchase on R-Series Refrigeration Door LED Conversion Kits and their components. Any product developing such defect in material or workmanship within this period will be repaired or replaced with a like product, at our option (IL) providing it is sent to us, transportation charges prepaid. Proof-of-Purchase date must accompany return to IL at our Roland, Iowa facility. IL does not warrant contractor s installation work or performance. This warranty is void if the product warranted has been damaged by accident or unreasonable use, neglect, improper installation or service, or other cause not arising out of defects in material or workmanship. This FIVE (5) YEAR limited product warranty is not transferable and applies to the original installation of the R-Series Refrigeration Door LED Conversion Kits for as long as the original purchaser owns them. SHIPPING DAMAGE The Innovative Lighting R-Series Refrigeration Door LED Conversion Kits should be examined for shipping damage upon receipt. The components in the kits have been carefully inspected before shipment. Any claim for loss or damage must be made to the carrier, which will provide any necessary inspection reports and/or claim forms. PRODUCT REGISTRATION PRODUCT INFORMATION R-Series Refrigeration Door LED Conversion Kit Model: R-Series Refrigeration Door LED Light Fixture Date Code (YYMMDD on lamp label): Date of Purchase: Number of units purchased: OWNER INFORMATION Name: Company: Address: City: State: Zip: Phone: E-mail: Owner Signature: Mail to: Innovative Lighting, LLC., P.O. Box 366, Roland, Iowa 50236 INSTALLER INFORMATION Name: Company: Address: City: State: Zip: Phone: E-mail: Installer Signature: