Model VSR, VS-F FM Approvals. All rights reserved. 1 of 1

Similar documents
Fire Sprinkler Monitoring Product Catalog

Fire Sprinkler Monitoring Product Catalog

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Fire Sprinkler Monitoring & Releasing Systems. Training Manual. Manual # REV H 7/18

FLAME ITEM PART NO CLIENT REF. NO. DESCRIPTION DESIGNATION MANUFACTURER CLASS UL FILE NO.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

WFDE Series Waterflow Detector

Gas Station & C Store SECTION CWM Job No

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

SECTION WET FIRE SPRINKLER SYSTEMS

Inspection Report Nursing Home Life Safety Code Section 4 - Annual Fire Alarm Testing and Maintenance. For

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

SECTION WET-PIPE SPRINKLER SYSTEMS

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Flow Control for Fire Protection

UL Online Certifications Directory

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

NBSXC.S4019 Household Burglar Alarm System Units. Household Burglar Alarm System Units

SECTION FIRE-SUPPRESSION STANDPIPES

AMCXC.S7513 Central and Monitoring Station Burglar Alarm System Units. Central and Monitoring Station Burglar Alarm System Units

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

SECTION WET-PIPE FIRE-SUPPRESSION SPRINKLERS

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

UROX.S911 - Smoke-automatic Fire Detectors. Smoke-automatic Fire Detectors

ADDENDUM NO. 3 March 19, 2018

OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Flow Control for Fire Protection

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

SECTION Fire Pumps

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Series 759 FireLock Alarm Check Valve

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Environmental Health & Safety

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Fire Sprinkler Systems Monitoring

A. This section includes design and performance information for fire protection and suppression systems.

FIRE SUPPRESSION SPRINKLER SYSTEM

SECTION FIRE PROTECTION

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

TotalPac X Single interlock SUREFIRE system

SECTION DRY-PIPE SPRINKLER SYSTEMS

TotalPac X Firecycle III Preaction Double interlock system

Interfacing Fire Alarm, Sprinkler and Elevator Systems

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

PL400 Patient Lift Scale Indicator Owner s Manual

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION WET-PIPE SPRINKLER SYSTEMS

CONSTRUCTION REQUIREMENTS

Worldwide Contacts.

B. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

SECTION DRY-PIPE FIRE-SUPPRESSION SPRINKLERS

DIVISION 21 - FIRE SUPPRESSION

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

B. Section Identification for Fire Suppression Piping and Equipment.

B. Related Sections: The following Sections contain requirements that relate to this Section.

Control Panels Switchgear Motors Generators Analysers Rooms/Buildings. Pressurized Enclosure. Static Pressurization. Leakage Compensation (LC)

Discontinued Product

Instructions for Installation, Operation, Care and Maintenance

WET-PIPE SPRINKLER SYSTEMS

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

Installation Instructions Manual No: Revision F

SECTION FIRE SUPPRESSION SYSTEMS

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

Technical Data. Installation

SECTION AUTOMATIC SPRINKLER PIPING

SECTION INTRUSION DETECTION

Central Battery & Central Monitoring System

standard response dry horizontal sidewall sprinklers

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

Facility Fire-Suppression Water-Service Piping

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

Transcription:

Waterflow Detectors, Vane Type Waterflow detectors installed in sprinkler systems provide an electrical alarm when a flow of water from the system equals or exceeds that of a single sprinkler. They can be used with either open or closed signaling circuits. They may consist of a flexible vane which projects into the waterway or a pressure-sensing device. For the flexible vane type, water movement deflects the vane, and the motion is transmitted to an alarm-actuating switch after a predetermined time delay. The time delay is accomplished by the use of an instantly recycling retard. Unless otherwise noted in the listing, the flexible vane type is to be used with pipe having an inside diameter which corresponds to Schedule 40 pipe for sizes up to and including 6 in. (152 mm) or Schedule 30 pipe for sizes 8 and 10 in. (203 and 254 mm). Waterflow detectors should not be specified for those systems where the time duration of a pressure fluctuation is greater than the retard time. Instantly recycling retards will not transmit an electrical alarm until the time duration of the pressure fluctuation or waterflow past the vane of the flow detector has exceeded the predetermined time setting of 30-60 seconds. Unless otherwise noted in the listing, these detectors have 175 psi (1205 kpa) rated working pressure. Model VSR, VS-F Model VSR. 2 through 8 in. NPS. Furnished with two snap switches and pneumatic retard. 450 psi (3100 kpa) rated working pressure. Model VSR-TSK. 2 through 6 in. NPS. Furnished with two snap switches and pneumatic retard, and a tamper switch to indicate that the cover was removed. 450 psi (3100 kpa) rated working pressure. Model VSR-F. 2 through 8 in. NPS. Furnished with two snap switches and pneumatic retard. 450 psi (3105 kpa) rated working pressure. Models VS-F, VSR-F. 2 through 5 in. NPS, for use with Schedule 10 pipe; 6 in. NPS, for use with pipe having a wall thickness of 0.134 in. (3 mm); 8 in. NPS (203 mm), for use with pipe having a wall thickness of 0.188 in. (5 mm), or Schedule 40 pipe. Model VSR-FE-2. 2 through 5 in. NPS, for use with Schedule 10 pipe; 6 in. NPS, for use with pipe having a wall thickness of 0.134 in. (3 mm); 8 in. NPS, for use with pipe having a wall thickness of 0.188 in. (5 mm). All sizes also for use in Schedule 40 pipe. 450 psi (3105 kpa) rated working pressure. Furnished with electronic retard. Model VSR-FEX. 2 through 8 in. NPS. For simultaneous usage as explosionproof for Class I, Division 1, Groups C and D; dust-ignitionproof for Class II/III, Division 1, Groups E, F and G hazardous (classified) locations indoors and outdoors (NEMA Type 4); 2 through 5 in. NPS, for use with Schedule 10 pipe; 6 in. NPS, for use with pipe having a wall thickness of 0.134 in. (3 mm); 8 in. NPS, for use with pipe having a wall thickness of 0.188 in. (5 mm). All sizes also for use in Schedule 40 pipe. 450 psi (3105 kpa) rated working pressure. Furnished with pneumatic retard. Company Name: Potter Electric Signal Company Company Address: 1609 Park 370 Place, Saint Louis, Missouri 63042, USA Company Website: http://www.pottersignal.com Listing Country: United States of America Certification Type: FM Approved 2007-2011 FM Approvals. All rights reserved. 1 of 1

USQT.S309 - Extinguishing System Attachments http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/showpage.html?nam... Page 1 of 3 30/11/2011 Page Bottom USQT.S309 Extinguishing System Attachments Extinguishing System Attachments See General Information for Extinguishing System Attachments POTTER ELECTRIC SIGNAL CO L L C 1609 PARK 370 PL HAZELWOOD, MO 63042 USA S309 SPRINKLER SYSTEM ALARM INITIATING DEVICES WET PIPE, PADDLE TYPE Model Size In. Pipe Schedule Max System VSG 2, 2-1/2, 3, 4 Water Mist 450 Systems Only VSR-F, VSR-FE, 2, 2-1/2, 3, 10-40 450 VSR-FE-2, VS-F 3-1/2, 4, 5, Steel 6, 8, 10 VSR 2, 2-1/2, 3, 3-1/2, 10-40 Steel 450 4, 5, 6, 8, 10 VSR-EU 2, 2-1/2, 3, 4, 5, 6, 8 10-40 Steel 450 VSR-S 1, 1-1/4, 1-1/2, 2 10-40 Steel 300 Listed Plastic K, L, M Copper VSR-SF, VS-SP 1, 1-1/4, 1-1/2, 2 10-40 Steel 250 Listed Plastic K, L, M Copper VSR-CF, VSR-C 2, 2-1/2, 3, Listed Plastic 175 2, 2-1/2, 3, 4 K,L,M Copper VSR-SFG, VSR-SG, VSR-SFT, VSR-ST 1, 1-1/4, 1-1/2, 2 Listed Plastic 250 Model VS-SP for outdoor use with Kit No. 1940037. Models VS-F, VSR-F, VSR-CF, VSR-C, VSR-FE, VSR-FE-2 for outdoor use with Kit No. 1940036. DRY-PIPE & WET-PIPE, PRESSURE TYPE Model Oper Max System *PS-10 0-20 300 *PS-10A 4-8 300 *PS-100 20-225 300 *PS10-1 4-15 300 *PS10-2 4-15 300 *PS10-1 w/tsk 4-15 300 *PS10-2 w/tsk 4-15 300 *PS10-1 w/tsk and Brass Bushing 4-15 300 *PS10-2 w/tsk and Brass Bushing 4-15 300 *PS-100A 20-175 300

USQT.S309 - Extinguishing System Attachments http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/showpage.html?nam... Page 2 of 3 30/11/2011 *PS100-2 25-175 300 WFS-B 10 250 WFSPDB 100 250 *WFSR-C 10 250 *WFSR-F 4-8 175 QRS 10-65 175 SUPERVISORY SIGNAL INITIATING DEVICES PRESSURE DEVICES Model Oper Max System *PS-40 20-225 300 *PS-40A 20-175 300 *PS40-1 10-60 300 *PS40-2 10-60 300 *PS40-1 w/tsk 10-60 300 *PS40-2 w/tsk 10-60 300 *PS40-1 w/tsk and Brass Bushing 10-60 300 *PS40-2 w/tsk and Brass Bushing 10-60 300 HLS-B 40 250 *PS-120 20-225 300 *PS-120A 20-175 300 *PS120-1 25-175 300 *PS120-2 25-175 250 *PS120-1 w/tsk 25-175 300 *PS120-2 w/tsk 25-175 300 *PS120-1 w/tsk and Brass Bushing 25-175 300 *PS120-2 w/tsk and Brass Bushing 25-175 300 CONTROL VALVE DEVICES Gate Valve Post Indicator Valve GVS PIVS-B OSYS-B *PIVSU-A1, -A2 *OSYSU-1, -2, -A1, -A2 *PCVS, PCVS-1, -2 PTS-B Plug Type Switch Special Application *PMS Plug Type Switch Special Application *PTS-C Plug Type Switch Special Application. BVS-1", -3/4", -1/2" Supervised Trim Valves. RBVS, RBVS-T Retro-fit Ball Valve Supervisory Switch. SUPERVISORY WATER TEMPERATURE DEVICES Steel or Wood Tank *TTS-S, TTS-W SUPERVISORY AIR TEMPERATURE DEVICES RTS-C, RTS-O, for indoor use. WATERLEVEL DEVICES *WLS-S (Steel Tank), WLS-W (Wood Tank), WCS

USQT.S309 - Extinguishing System Attachments http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/showpage.html?nam... Page 3 of 3 30/11/2011 *For indoor or outdoor use. Last Updated on 2011-06-14 Questions? Print this page Notice of Disclaimer Page Top Copyright 2011 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2011 Underwriters Laboratories Inc. "

EUROPEAN DECLARATION OF CONFORMITY 07 ISSUE DATE: MANUFACTURER: PRODUCT: SERIES: MODEL/TYPE REFERENCE: March 2, 2007 POTTER ELECTRIC SIGNAL COMPANY 2081 CRAIG ROAD ST. LOUIS, MO 63146 USA Pressure Switches PS10, PS40, PS100, PS120, and WFSR-F PS10-1A, PS10-2A, PS40-1A, PS40-2A, PS100-2A,PS120-1A, PS120-2A, and WFSR-F. PS10-1, PS10-2, PS40-1, PS40-2, PS100-2, PS120-1, and PS120-2. THE UNDERSIGNED HEREBY DECLARES, ON BEHALF OF THE POTTER ELECTRIC SIGNAL CO. OF ST. LOUIS MISSOURI, USA THAT THE ABOVE PRODUCT, TO WHICH THIS DECLARATION RELATES IS IN CONFORMITY WITH THE PROVISIONS OF: DIRECTIVES: COUNCIL DIRECTIVE(s) 73123/EEC AND 97/23/EC STANDARDS: COUNCIL DIRECTIVE 93168/EEC (JULY 22,1993) EN 60 947-5-1 1991 LOW VOLTAGE SWITCHGEAR & CONTROL GEAR AND 97/23/EC PRESSURE EQUIPMENT DIRECTIVE THE TECHNICAL CONSTRUCTION FILE REQUIRED BY THIS DIRECTIVE IS MAINTAINED AT THE CORPORATE OFFICE OF: POTTER ELECTRIC SIGNAL COMPANY 2081 CRAIG ROAD ST. LOUIS, MISSOURI USA EURODOC. Brad Serangeli Quality Systems Manager