Declaration of conformity

Similar documents
4) Intrinsic Safety Certification

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

IECEx Certificate of Conformity

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

FDOOT241-A9-Ex Multisensor fire detector

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

OOH740-A9-Ex Multisensor fire detector

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

SET-2000 Oil/Sludge 12 VDC

Technical Data. General specifications. Rated operating distance s n 5 mm

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

DB5 Intrinsically Safe Sounder Type DB-5

EU DECLARATION OF CONFORMITY

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

E2S Datasheet v10a

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

OOH740-A9-Ex Multi-sensor fire detector

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INSTRUCTION MANUAL (ATEX)

SET Installation and Operating Instructions. Level switch for one sensor

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Data. Dimensions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Certificate of Compliance

Certificate of Compliance

IECEx Certificate of Conformity

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

Safety instructions VEGAPULS 64

Operating Instructions Edition 02/2007

Intrinsically Safe Flame Detector Installation Guide

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Annubar Flowmeter Series

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Installation and Operating Instruction

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Weighing whole with Dini Argeo indicator + Dini Argeo JBxxx Atex junction box + zener barriers + Dini Argeo Atex load receptor (s/n )

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

SET-2000 Hi Level/Oil

VERSAFLOW VORTEX Supplementary instructions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Intrinsically Safe Solutions

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

IECEx Certificate of Conformity

Technical Data. Dimensions

Universal Tank Alarm Type Installation, Operation & Maintenance

Installationsmanual GWSL1100/2100, GWML3100

srra, of Conformity IECEx Gert f cate ?-ot,b

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

FDCL221-Ex Line adapter (Ex)

OPTIBAR P 1010/2010 C Supplementary instructions

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

AND INSTALLATION MANUAL

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

PROTECT SRB 200EXi-1A

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

OilSET-1000 (12 VDC)

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

PumpSaver ISS-105 IS Super Cell Installation Guide

国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ ) (Attachment Ⅰ) Attachm

Certificate of Compliance

BA488CF Intrinsically safe Panel mounting Fieldbus Display

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

OPTIBAR DP 7060 Supplementary Instructions

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Supplementary Installation and Operating Instructions. Category II2G

User s Manual YTA610 and YTA710 NEPSI Certification

FAHM Co. Temperature Transmitter PTT74 Series

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

PEPPERL+FUCHS GmbH

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Mark* VIe and Mark VIeS Control Systems Equipment in Hazardous Locations (HazLoc) Instruction Guide

Instrumentation Products and Applications

Tank Gauging System Special Safety Instruction

Fire Alarm System Accessories

Transcription:

File: ATEX Manoswitch DoC 2017-10-20 Rev: 2017-10-20 id: mk Declaration of conformity The products listed in Appendix B, meet the requirements for a simple apparatus given by the standards listed below. As the product does not have an own potential source of ignition and therefore it is not subject to the ATEX directive. Declaration is only valid when installation is in accordance with Appendix A, page 2 of this document. For products listed in Appendix B as containing plastic, there is a risk of ignition by electrostatic discharge when rubbing the equipment, which cannot be avoided. To comply with ATEX these products must have a warning label Avoid electrostatic charging attached in an easy to read position. Product identification: All items listed in Appendix B. Description of product: Component for Fire Extinguishing System. Product specification: Devices in the category Simple apparatus Directives & Standards: ATEX 2014/34/EU (article 1, clause 1a) EN 60079-0 :2012 incl A11:2013, EN 60079-11:2012, (clause 5.7 a). Limitations Ex-Classification: A certified intrinsic safety barrier (ISB) (Zener Diode Barrier or Galvanic Isolated Barrier) must be connected. Maximum values for the ISB: Uo = 28V Io = 93mA Po = 700mW Eg: Phoenix MACX MCR-Ex-SL-RPSSI-I-2865340 or Pepperl+Fuchs Z728) Ex ib IIC T4 (-40Cº Ta +70Cº) Ci< 0.2nF, Li negligible =>0 Ui < 28V, Ii < 100mA, Pi<700mW. Production facility: Product marking: Fire Eater, Vølundsvej 17, 3400 Hillerød Fire Eater name or Logo, Product name, Serial number. Vølundsvej 17, 3400 Hillerød, Denmark Conformity mark: Certificates: None Notified body: CNPP 1116 BRE 0832 DNV GL 0575 UL EX15566 FM3050976-2 II 2G Ex ib IIC T4, Simple Apparatus Signed by Technology Manager Hillerød: 20 October 2017 Michael Kroneder (CTO) Fire Eater A/S Vølundsvej 17 DK-3400 Hillerød Tel.: +45 7022 2769 VAT No.: 184.030 www.fire-eater.com e-mail: info@fire-eater.com

File: ATEX Manoswitch DoC 2017-10-20 Version date: 2017-10-20 id: mk Appendix A, Ex Calculation Calculation of the circuitry for verification of Ex compliance of the system. The output parameters of the safety barrier (Ex) must be lower than the input parameters of the devices. Therefore, the following applies: Control Panel Non-Hazardous Area Intrinsic Safety Barrier Hazardous Area Uo Ui Io Ii Intristically Po Pi Safe Co Ci+Cc Device Lo Li+Lc Ui: Max. permissible voltage Uo: Max. open-circuit voltage [V] Ii: Max. permissible current Io: Max. short-circuit current [ma] Pi: Max. permissible power Po: Max. short-circuit power [mw] Ci: Internal capacitance Co: Max. permissible capacitance [nf] Li: Internal inductance Lo: Max. permissible inductance [mh] Cc: Cable capacitance Lc: Cable inductance n = Total number of devices l = Total cable length [m] Calculation example: 3 manoswitches in series, with a total cable length of 100 meters (0.1km) Safety barrier characteristics: (Zener barrier Pepperl+Fuchs Z978) Uo: 28 [V] Io: 47 [ma] Po: 320 [mw] Co: 83 [nf] Lo: 1.6 [mh] Manoswitch characteristics: Ui: 28 [V] Ii: 100 [ma] Pi: 700 [mw] Ci: 0.2 [nf] Li: ~ 0 [mh] Cable characteristics: (FE item 18032313) Cc: 270 nf/km Lc 0.67 mh/km Calculation Uo Ui => 28 28 [V] Meet the requirement Io Ii => 47 100 [ma] Meet the requirement P0 Pi => 700 700 [mw] Meet the requirement Co (n xci) + (l x Cc) => 83 [nf] (3x0.2) + (0.1 x 270) = 27.6 [nf] Meet the requirement Lo (n x Li) + (l x Lc) => 1.6 [mh] (3x0) + (0.1x0.67) = 0.067 [mh] Meet the requirement Fire Eater A/S Vølundsvej 17 DK-3400 Hillerød Tel.: +45 7022 2769 VAT No.: 184.030 www.fire-eater.com e-mail: info@fire-eater.com

File: ATEX Manoswitch DoC 2017-10-20 Version date: 2017-10-20 id: mk Appendix B Product data: Product with metal body 305373 ManoSw 28.4MPa sp16.6 UL2127 305374 ManoSw 43.1MPa sp24.9 UL2127 305360 ManoSw 0-160 bar sp50 EN12094 305368 ManoSw 250bar sp122 305376 ManoSw 43.1MPa sp22.5 305370 ManoSw 0-250 bar sp 166 EN12094 305375 ManoSw 0-400 bar sp 249 EN12094 303013 ManoSw 0-250bar sp 150 conn 303014 ManoSw 0-250bar sp 166 conn 303017 ManoSw 0-400bar sp 225 conn 303018 ManoSw 0-400bar sp 249 conn 305375 ManoSw 0-40MPa sp249 GOST-R 305400 Pressure Switch w. Manual Reset Including below variants: -8 Customer specified -23 EAC (former GOST) -31 IEC331 cable -44 AISI316 housing -131 CCCF dial Fire Eater A/S Vølundsvej 17 DK-3400 Hillerød Tel.: +45 7022 2769 VAT No.: 184.030 www.fire-eater.com e-mail: info@fire-eater.com

Fire Eater A/S Attn.: Mr. Michael Kroneder Vølundsvej 17 3400 Hillerød Denmark 2630 Taastrup Denmark Phone +45 72 20 20 00 info@dti.dk www.dti.dk 25 October 2017 ATEX Statement concerning Simple Apparatus" Product description The Manoswitch is in the principle constructed as a standard Mechanical manometer of the Bourdon tube type, which in addition is mounted with a build in electrical micro switch. The micro switch is operated directly by a mechanical operator arm welded to the Bourdon tube. Electrical components: The Manoswitch is mounted with one single electrical component which is a simple micro switch of the type Panasonic micro switch: AVT3210613 or AVT3212613 or AVT3214613 rated 0.1 A 250 V ac. Type variants: Product with metal body 305373 ManoSw 28.4MPa sp16.6 UL2127 305374 ManoSw 43.1MPa sp24.9 UL2127 305360 ManoSw 0-160 bar sp50 EN12094 305368 ManoSw 250bar sp122 305376 ManoSw 43.1MPa sp22.5 305370 ManoSw 0-250 bar sp 166 EN12094 305375 ManoSw 0-400 bar sp 249 EN12094 303013 ManoSw 0-250bar sp 150 conn 303014 ManoSw 0-250bar sp 166 conn 303017 ManoSw 0-400bar sp 225 conn 303018 ManoSw 0-400bar sp 249 conn 305375 ManoSw 0-40MPa sp249 GOST-R 305400 Pressure Switch w. Manual Reset Including below variants: -8 Customer specified -23 EAC (former GOST) -31 IEC331 cable -44 AISI316 housing -131 CCCF dial

Scheduled Drawings The Manoswitch is specified by the drawings: Engineering data Sheet, 11 pages, Document: UL listed production 11, Manoswitch 2015-05 The Declaration of Conformity and Instructions are specified by document: ATEX Manoswitch DoC 2017-10-20, Rev. 2017-10-20. 3 pages. Simple Apparatus Intrinsically safe electrical equipment for use in Flammable atmospheres (zone 0, 1 or 2) must fulfil the requirements of EN 60079-0:2012 inkl. Amd. A11:2013 together with EN 60079-11:2012. The following components are considered as simple apparatus in accordance with EN 600079-11 clause 5.7: passive components, for example switches, junction boxes, resistors and simple semiconductor devices. Installation of Manoswitch - Conditions The Manoswitch can only be used as Simple Apparatus when installed in a system where it is supplied from a certified Intrinsically Safe safety barrier module (e.g. a Zener barrier) mounted in the safe area. The Manoswitch must be installed in accordance with the installation instructions specified in the Declaration of Conformity : Appendix A, Ex-Calculation Entity parameters for Manoswitch Ui: 28 [V], Ii: 100 [ma], Pi: 700 [mw], Ci: 0.2 [nf], Li: ~ 0 [mh] The chosen barrier module must match these entity parameters. Marking of Simple Apparatus In accordance with EN 60079-14:2014, Clause 16.4 (covering Installation of equipment for explosives atmospheres), Simple Apparatus must be clearly identifiable by durable marking. Labelling of simple apparatus may be done by e.g. the manufacturer of the equipment and should make it possible to clearly identify the equipment as Simple Apparatus and furthermore a reference to the correct installation may also be made. Page 2 of 3

Final ATEX Marking: II 2G Ex ib IIC T4 Simple Apparatus The Manoswitch is marked in the following way: Conclusions When the Manoswitch is installed in accordance with Fire Eater s Declaration of Conformity including the instructions in Appendix A, Ex-Calculation, the product can be considered as Simple apparatus in accordance with EN 60079-11, Clause 5.7. Best regards, Jakob Nittegaard ATEX Senior Specialist Product Development Page 3 of 3