Guide to Hazardous Location Approvals:

Similar documents
Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

MICRO SWITCH GSX Series

Intrinsically Safe Transmitters, Option Code 2n

MICRO SWITCH BX/BX2 Series

How Limit Switches Can Stop Machines from Going Boom

UL HAZARDOUS LOCATIONS SERVICES

V-Basic Standard V15 Series

Guide to Intrinsically Safe Portable Radios

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

MICRO SWITCH GLL Series

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

MICRO SWITCH NT Series

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

MICRO SWITCH NT Series

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

MICRO SWITCH Safety Limit Switches for Hazardous Locations GSX Series Issue 3. Datasheet

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Wireless Panel-Mount Monitor

Valve Position Indicator VPX Series Issue E. Datasheet

HFX Fiber Optic Component 50 Mbps, 650 nm LED

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO


HOA6480 Series Barcode Sensor Infrared Products

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Micropower Omnipolar Digital Hall-Effect Sensor ICs

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

HIH-4000 Series Humidity Sensors

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Beamex. Calibration White Paper. Calibration in hazardous areas

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Understanding Hazardous Locations Concepts

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Beamex Calibration White Paper. Calibration in hazardous areas

HIH-5030/5031 Series Low Voltage Humidity Sensors

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

MICRO SWITCH V15W Series Watertight Miniature Switches

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

HIH-4602-L Series Humidity Sensors

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

MICRO SWITCH BAF/DTF Series

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Installation Instructions for the 600 Series Optical Encoders

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

Guide for hazardous areas

FSS-SMT Series. Low Profile Force Sensor

Installation Instructions for the

Overview of Hazardous Locations as They Relate to Solenoid Valves

FEATURES AND BENEFITS

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

General Purpose Industrial VRS Magnetic Speed Sensors

S T R I T T & P R I E B E I N C.

High Temperature Industrial VRS Magnetic Speed Sensors

Installation Instructions for the

Potential Applications

Wireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series)

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Hazardous Area Classifications and Protections

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

MICRO SWITCH E6/V6 Series

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Linear Current Sensors

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

ESSENTIAL EXPLOSION PROTECTION

Sensors and Switches in Commercial Traction Elevators

Integrated Solutions Low Voltage Systems

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Indoor/outdoor resistance thermometer Model TR60

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

MICRO SWITCH Basic Switches Line Guide

Limitless Wireless Din-Rail Receiver. WDRR Series. Datasheet

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Transcription:

Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition to switch performance, it s important to understand the country of use, as well as the approvals each switch carries. This selection guide will help to define Hazardous Area Approvals and Markings for both North American and Global applications, as well as define the approvals MICRO SWITCH Hazardous Area Switches carry. For assistance with selecting a hazardous area switch, please contact Honeywell s product team at +1-815-235-6847, info.sc@honeywell.com, or your Honeywell distributor. Sensing and Control

North American Traditional Marking Class I (NEMA Type 7) Class II (NEMA Type 9) North American Typical Marking Hazard Class Area Classification 1 Gas/Dust Group Class I Division 1 Groups A, B, C, D Group A Acetylene Flammable Gas, Vapors, & Mist Division 1 The hazardous gas/dust is Group B Hydrogen continuously present or intermittently present during normal operation Group C Ethylene Group D Propane and Methane Group E Combustible metal dusts The hazardous gas/dust is only Group F Combustible carbonaceous dusts Combustible Dust Division 2 present under abnormal conditions Other combustibles (flour, grain, Group G wood, plastic, chemicals) 1 If a product is covered for Division 2, it will be marked. If the Division is not included in the marking, then it is presumed to be Division 1. Division 1 certified products can be used in Division 1 or 2 areas. North American Zone Style Marking Hazard Class Area Classification American National Standard Explosion Protected Class I Zone 0 A Ex Zone 0 Hazardous gas is continuously present Class I Class II Flammable Gas, Vapors & Mist Combustible Dust Zone 1 Zone 2 Zone 20 Zone 21 Hazardous gas intermittently present during normal operations Hazardous gas present under only abnormal conditions Hazardous dust is continuously present Hazardous dust intermittently present during normal operations A Approved to US Standard ISA 60079-*. Differentiates between this Certification and the ATEX and IEC Ex Certifiacations with use the EN and IEC 60079-* Standards Ex Device is explosion protected for use in hazardous environments Zone 22 Hazardous dust present under only abnormal conditions 2 Typically, IIC is the preferred coverage and will allow the product to be used in IIB and IIA environments as well. 3 Typically, T6 is the preferred coverage and will allow the product to be used in T5-T1 requests (dependent upon the ambient the application). Most Honeywell limit switches are T6 rated. Comparison on the two Area Classification Styles Hazard Level Division Scheme Zone Scheme Continuous Hazard Zone 0/Zone 20 Division 1 Intermittent Hazard Zone 1/Zone 21 Hazard Under Abnormal Conditions Division 2 Zone 2/Zone 22 2 sensing.honeywell.com

North American Typical Marking North American Product Label Example North American Approvals Agency NEMA Environmental Seal Rating North American Zone Style Marking North American Traditional Marking Protection Concept Gas/Dust Group Temperature Class Equipment Protection Level d IIC T6 Ga Protection method the product uses to be used in the hazardous environment IIC 2 Acetylene and Hydrogen T6 3 85 C Ga Gas, suitable for Zones 0, 1, 2 d Flame proof. Can contain the explosion and extinguish the flame IIB + H2 Ethylene and Hydrogen T5 IIB Ethylene T4 100 C 135 C Gb Gas, suitable for Zones 1, 2 Gc Gas, suitable for Zone 2 IIA Propane and Methane T3 200 C Da Zones 20, 21, 22 ia, ib, ic Intrinsically Safe. Limits energy of sparks and surface temperature IIIC Combustible metal dusts T2 IIIB Combustible carbonaceous dusts and other combustibles (flour, grain, wood, plastic, chemicals) T1 300 C 400 C Db Zones 21, 22 Dc Zone 22 Comparison on the two Gas/Dust Group Styles Substance Hazard Class Division Groups Zone Groups Acetylene Group A IIC Hydrogen Group B IIC Ethylene Class I Group C IIB Propane Group D IIA Methane Group D IIA Combustible metal dusts Group E IIIC Combustible carbonaceous dusts Class II Group F IIIB Other combustibles (flour, grain, wood, plastic, chemicals) Group G IIIB Honeywell Sensing and Control 3

ATEX and IEC Ex Typical Marking Part 1 ATEX and IEC Ex Typical Marking Complies with European Directive Notified Body Number Specific marking for ATEX Directive Equipment Group Equipment Category Environment 0518 II 2 GD All products that comply with any European Directive are marked with CE. This can be the Explosive Atmospheres Directive (ATEX) or any number of other Directives Each notified body (agency) has a number. Honeywell places the number of the notified body that certifies the factory on the label. 0518 will be on all ATEX products from Galena, Illinois. 1180 will be on all ATEX products from Newhouse. Scotland All products that comply with the ATEX Directive for Explosive Atmospheres will be labeled with this symbol I Mines 1 II All other areas 4 2 4 Honeywell products will all be Equipment Group II. None of our products are certified to be used in mining applications. 3 Products can be used in Zones 0, 1, 2 and 20, 21, 22 Products can be used in Zones 1, 2 and 21, 22 Products can be used in Zones 2 and 22 G D Gas environments Dust environments ATEX and IEC Ex Typical Marking Part 2 Explosion Protected Protection Concept Gas/Dust Group Temperature Class Equipment Protection Level (EPL) Ex d IIC or IIIC T6 or T85 C Ga The device is explosion protected for use in hazardous environments The protection method the product uses to be able to be used in the hazardous environment d ia, ib, ic Flame proof. Contains the explosion and extinguish the flame Intrinsically safe. Limits energy of sparks and surface temperature IIC 2 IIB + H2 Acetylene and Hydrogen Ethylene and Hydrogen T6 3 T5 IIB Ethylene T4 IIA IIIC IIIB Propane and Methane Combustible metal dusts Combustible carbonaceous dusts and other combustibles (flour, grain, wood, plastic, chemicals) T3 T2 T1 85 C 100 C 135 C 200 C 300 C 400 C Ga Gb Gc Da Db Dc Gas, suitable for Zones 0, 1, 2 Gas, suitable for Zones 1, 2 Gas, suitable for Zone 2 Zones 20, 21, 22 Zones 21, 22 Zone 22 2 Typically, IIC is the preferred coverage and will allow the product to be used in IIB and IIA environments as well. 3 Typically, T6 is the preferred coverage and will allow the product to be used in T5-T1 requests (dependent upon the ambient the application). Most Honeywell limit switches are T6 rated. 4 sensing.honeywell.com

ATEX and IEC Ex Typical Marking ATEX and IEC Ex Product Label Example ATEX Typical Protection Marking Specific marking for ATEX Directive Complies with European Directory Notified Body Number Area Classification Styles Hazard Level Zone Scheme Continuous Hazard Zone 0/Zone 20 Intermittent Hazard Zone 1/Zone 21 Hazard Under Abnormal Conditions Zone 2/Zone 22 Honeywell Sensing and Control 5

MICRO SWITCH Hazardous Area Switch Approvals EX CX LSX BX BX2 GSX CLSX GXS 14CE100 WBX * * * * * * Select catalog listings * 6 sensing.honeywell.com

Global Approval Descriptions Mark Country Approval Description North America North America United States and Canada Europe Global Europe EurAsian Conformity Korea China Brazil UL Mark means UL has tested representative samples of the product and determined the product meets the requirements of UL. These requirements are based primarily on published and nationally recognized Standards for Safety. The CSA mark demonstrates that a sample of the product has been certified to applicable standards including standards written or administered by the American National Standards Institute (ANSI), Underwriters Laboratories (UL), CSA Group (CSA), NSF International (NSF), and other North American and global organizations. The culus mark certifies the equipment was evaluated to Canadian and US standards by Underwriters Laboratories. The combination mark indicates compliance with both Canadian and U.S. Requirements. Listed means that the product can be operated as sold, in accordance with its inscriptions and operating instructions, without retesting by UL. Products are for use in hazardous locations where explosive atmospheres may be present. Certification covers division and zone area classification systems for the United States and/or Canada. The Ex mark is a statement from an independent Notified Body verifying compliance with the requirements of the European standards that are harmonised with the 94/9/EC Directive (ATEX Directive, named after the French ATmosphere EXplosible ). The IEC Ex mark means the equipment complies with the requirements of the International Electrotechnical Commission Explosive. The objective of the IECEx system is to facilitate international trade in equipment and services for use in explosive atmospheres, while maintaining the required level of safety. Notified Body. For equipment used in the European Union in accordance with the R&TTE Directive, the CE Mark and the notified body (NB) identification number is used when the NB is involved in the conformity assessment procedure. Products certified are labelled with Customs Union Mark of Conformity, called EurAsian Conformity Mark EAC, before they are placed on the market of the Customs Union member states (Russia, Belarus and Kazakhstan). Korea s Electrical Communication Basic Law, requires EMC testing and certification for many electronic products. Korean EMC certifications are issued by National Radio Research Agency (RRA), which is organized under the Korea Communications Commission (KCC). EMC testing includes electromagnetic interference (EMI) and susceptibility (EMS). Certified equipment is labeled with the KC mark and certification number. NEPSI is an international testing laboratory accredited by IECEx Scheme, Shanghai Inspection and Testing Center of Electrical Equipment for use in Explosive Atmospheres for National Work Safety authorized by China State Administration of Work Safety (with qualification of Class A). NEPSI runs strictly in accordance with ISO/IEC 17025 and ISO/IEC 17020. Brazil s IN METRO (Institute of Metrology, Standardisation and Industrial Quality) is the government body responsible for the implementation of measurement, safety and quality standards for electrical and electronic products. Honeywell Sensing and Control 7

Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: sensing.honeywell.com Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Find out more To learn more about Honeywell s sensing and control products, call +1-815-235-6847, email inquiries to info.sc@honeywell.com, or visit sensing.honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 002399-1-EN IL50 GLO April 2015 Copyright 2015 Honeywell International Inc. All rights reserved.