PROTECTGLOBAL.COM. Important information for users

Similar documents
PROTECTGLOBAL.COM A FOG CANNON TM FROM PROTECT TM. secures your valuables in seconds and makes it impossible for the burglar to steal anything!

PROTECTGLOBAL.COM A FOG CANNON FROM PROTECT. secures your valuables in seconds and makes it impossible for the burglar to steal anything!

Emergency Response Procedures

HV2R ROTARY LASER INSTRUCTION MANUAL

G4S ACADEMY THE MAMUTE SECURITY ANALYSIS MODEL

1 Introducing Eve Smoke

Z-Stream Fog Machine User Manual English

Antari X-310 ORDERCODE 60663

ML1 MULTI-LINE LASER INSTRUCTION MANUAL

GF-3000 Ground Fog Machine. user manual

30-DAY NOTICE OF INTENT TO VACATE

CL3 HYBRID MULTI-LINE LASER INSTRUCTION MANUAL

Authorized individuals to be notified. Include two (2) persons with access to the premises to allow emergency access.

Bosch Smart Home. Motion Detector Instruction Manual

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

Free Advice Free Quote Nationwide. Security Direct property protection. Home Security Buying Guide SECURITY DIRECT.

Vivid Fogger Grey ORDERCODE Black ORDERCODE 60655B Orange ORDERCODE 60655O Red ORDERCODE 60655R Blue ORDERCODE 60655U Yellow ORDERCODE 60655Y

PC71 American Style Fridge Freezer

Contents 1. Helpline No. UK/ North Ireland Rep. Ireland , Web Support Model Number: MD

INSTRUCTION MANUAL PC255O

INSTRUCTION MANUAL PC255O

Manual. Snow machine S-2

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE # ALARM SYSTEM ORDINANCE

Antari Z-300 ORDERCODE 60661

OPERATING INSTRUCTIONS IN CASE OF ACCIDENTS AND EMERGENCIES

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE NO ALARM SYSTEM ORDINANCE AMENDMENT

Intruder Alarm Advice for Domestic Properties

2-ZONE EASYFIT INTRUDER ALARM

INSTRUCTIONS AND WARRANTY

W A V E. Operating Manual SOLU T I O N I N A S P E C IAL D E S I G N E D ITI O N

Manual. Fazer DFZ-800

Instruction Manual for Wall Mounted Fireplace, Models: ARC 103A & VAGUE 101A

EN Variable Temperature Electric Kettle

INSTRUCTIONS AND WARRANTY

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Steam Station User Manual

Manual. Hazer DHZ-450

SPECTRA 1727 USER S GUIDE

THE NEXT SMART HOME GENERATION

Freemove Air.

Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the

dss PHILADELPHIA POLICE DEPARTMENT DIRECTIVE 4.11

Welcome to TRACKER. Protection for your Caravan. TRACKER Caravan Protection IN PARTNERSHIP WITH

Fog 1550 FT USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

SCS motion sensors Surface/wall mounting - PIR

Operating instructions in the back. SVFV3250L SVFV3250LR

WARNING! Read the safety precautions in this manual before installing, operating or servicing this product.

Operating instructions

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

QUICK USER GUIDE. Alarm Control Panel

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

Please read and keep these instructions for future use

RMS-I-DE-01 Smoke Detector

The Danish Energy Authority to carry out inspections in June and July 2012

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

EN Z Subject to change due to technical improvements! Operating instructions

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

INSTRUCTIONS AND WARRANTY

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

EN Glass Jug Blender

2-ZONE EASYFIT INTRUDER ALARM

ismartalarm Home Security System OWNER S MANUAL

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Austin Independent School District Police Department Policy and Procedure Manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Sync. Smart Home Alarm

3.5-GALLON PARTS WASHER OWNER S MANUAL

Antari Low Fog Machine

INSTRUCTIONS AND WARRANTY

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

INTRUDER ALARM FOR BUSINESS SECURITY

OPERATING INSTRUCTIONS

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

INTRUDER ALARM FOR BUSINESS SECURITY

Solution Ultima 862 Operators Manual ISSUE 1.10

SF Owner s Manual FOG MACHINE. 1

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

Operating Instruction

INSTRUCTIONS AND WARRANTY

CTA15-2 warming drawer. operating and installation instructions

ORDINANCE NO

Article 3: Police Regulated Occupations and Businesses. Division 37: Burglary, Robbery and Emergency Alarm Systems

Sonnet Plus Anthem Genesis Soraya

Destiny Destiny Owners Manual

Operating instructions Page 16. Refrigerator Read the operating instructions before switching on for the first time

Monitored Alarm System Purchasing Guide

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Sonnet Plus Anthem Genesis Soraya

Digiplex LED Keypads User s Manual

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

OWNERS MANUAL ELECTRIC STOVES

Induction Cooktop User's manual

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

Operating manual UNIQUE UNIQUE [HAZER]

ACCESS.

Transcription:

PROTECTGLOBAL.COM Important information for users

2 Contents Before use... Page 4 Operation.... Page 5 Cleaning and maintenance.... Page 6 A safe product guaranteed.... Page 7 What the LEDs mean.... Page 8 Warnings.... Page 9 Instructions for preventing unintentional activation... Page 10 Instructions for intentional activation... Page 11 Interaction between fog protection and fire alarm systems... Page 11 Annual service.... Page 12 Power consumption... Page 12

Important information for users 3 Stop the burglar in a few seconds with a PROTECT Fog Cannon Thank you for buying this PROTECT Fog Cannon. These instructions are intended for everyday users of the fog-protected premises, and for the security supervisor with responsibility for the entire alarm installation. Please read the following pages carefully to ensure maximum security, satisfaction and product lifetime. PROTECT A/S is a wholly Danish-owned firm, with production facilities in Aarhus the second-largest city in Denmark. The company is the world s biggest manufacturer of fog cannon products for burglary protection, and distributes to more than 50 countries. A fog cannon is intended to serve as a supplementary security product for an alarm system. A fog cannon is a generator that uses a heating element to convert harmless liquid into a thick, dry, white fog-like cloud. This fog has a disorienting effect and you cannot steal what you cannot see... Fog security protection helps prevent theft, vandalism and robbery. NB! PROTECT Fog Cannon products must only be installed and serviced by a qualified alarm fitter or electrician. For additional information, see www.protectglobal.com.

4 Important information for users Before use Have you and/or others been instructed in the correct use of the alarm system and fog protection set-up? Before the alarm fitter leaves the premises, all users should have received instruction in how the fog security system works. DON T FORGET! Have you or your alarm company remembered to inform the local police and fire service about your fog protection installation? Make sure to inform your neighbours, if any, that you have installed fog security protection. Have you or your alarm company remembered to place warning labels on your windows and doors? The yellow labels help prevent break-ins, and provide valuable information to cleaning staff and others. We recommend that you enter into an annual service agreement with your alarm company that involves testing the fog cannon. See elsewhere in these instructions.

Important InformatIon for users 5 Operation The fog cannon is primed whenever the alarm system is activated. If you then enter the secured area, both alarm and fog cannon will be triggered. When you disconnect the alarm, the fog cannon will be disconnected automatically. PROTECT Xtratus = 8 min. PROTECT FOQUS = 7 min. PROTECT QUMULUS = 8-10 min. PROTECT 600i = 10-15 min. PROTECT 1100i = 20-25 min.* PROTECT 2200i = 35-40 min.* *We recommend that you keep the power connected 24/7. system is activated. Depending on the installation method and the fog cannon model, it may take up to 45 minutes for the unit to become warm enough to generate fog. We recommend that you keep your fog cannon products warmed up at all times so they are ready to generate fog as soon as the alarm Every fog cannon is monitored by the alarm company from which it was purchased (or the relevant subcontractor). The alarm company can register activation of the fog cannon, attempted vandalism and errors. An authorised alarm fitter must be engaged to set the fogging time, etc. and to replace the fog fluid container (however, end users themselves can replace the fluid container in PROTECT QUMULUS models manufactured after 1 September 2014). The same as for model Xtratus. QUMULUS Scan the codes with a smartphone to check how to replace the fluid container in a QUMULUS model manufactured after 1 September 2014 or a Xtratus. Xtratus

6 Important information for users Cleaning and maintenance Clean PROTECT Fog Cannon products with a damp cloth without any cleaning agents, chemicals or solvents. If you did not air the premises within 1 hour of a fog cannon being activated, you should wipe down all horizontal surfaces with a damp cloth without any cleaning agents, chemicals or solvents. For additional details, see pages 10 and 11. End users themselves can change the fluid container in PROTECT QUMULUS models manufactured after 1 September 2014. The same as for model Xtratus. Fluid containers in all other models must only be replaced by an authorised alarm fitter. See the previous section for details.

EUROPEAN STANDARD OF CRIME PREVENTION WITH SECURITY FOG DEVICES Important information for users 7 A safe product guaranteed Quality products from PROTECT are CE labelled and comply with the applicable EU standards concerning fog cannon units. This means that fitters and users of the equipment can be sure they are working with a safe product. Find out more in the Warnings section of these instructions. Several test institutes in Denmark and abroad (including Det Norske Veritas, the Danish Technological Institute and Eurofins) have tested and approved PROTECT products, and confirmed that the fog is completely harmless to people, animals, electronic devices and furnishings. You can see the certificates online at www.protectglobal.com. At the same time, PROTECT products are so operationally stable and reliable that they come with a warranty of up to five years*. *Products are supplied with a 2-year warranty as standard. By registering your fog cannon online, you will receive an extra 3-year warranty (except Xtratus) free of charge! Always follow the instructions supplied with the product. INDEPENDENTLY TESTED AND GAINED EN 50131-8 EUROPEAN STANDARD PROTECT products are approved by international test institutes in accordance with applicable EU standards.

8 Important information for users What the LEDs mean * Low fluid level: PROTECT Fog Cannon units emit audible (short beeps ) and visual signals (flashing yellow LED on the front panel) when the fluid level is low. Overview of LED signals: The green LED flashes when the fog cannon is connected to a power supply. The green LED lights constantly when the fog cannon is hot enough and ready to generate fog As mentioned above, the yellow LED will flash in the event of low fluid level All LEDs are extinguished when the alarm is connected Red LED: - One flash every 10 sec. means mains power outage** - Three flashes every 10 sec. indicates a signal from a fire alarm system to the fog cannon* - Four flashes every 10 sec. means low battery charge** - Constant flashing: Serious error that requires intervention from the fitter* * Diodes for Xtratus: See manual page 21 ** Requires a service visit contact the fitter

Important information for users 9 Warnings Do not touch the nozzle, as it can become very hot and cause burns. Never look directly into the nozzle. Do not hang anything up immediately in front of the fog cannon. We recommend that you maintain a safety distance of at least 35 cm. PROTECT Fog Cannon units are IP approved for indoor use and must therefore not be exposed to water and moisture. Min. 35 cm. Spilled fog fluid in the form of drips or splashes from handling the fluid and/or installing the fog cannon must be removed immediately, otherwise it may constitute a slipping hazard. The fog fluid is a mixture of water and glycol; as such it must not be ingested. Make sure to store the fluid out of the reach of children and pets. In the event that a large quantity of the fluid is ingested, contact a doctor without delay. In the event of contact with the eyes, rinse immediately with clean water for at least 15 minutes. In the event of contact with the skin, wash thoroughly with soap and rinse with clean water. Make sure NEVER to connect the alarm system during working hours while staff are present in the fog-protected rooms.

10 Important information for users Instructions for preventing unintentional activation If the fog protection is activated unintentionally, contact the alarm company s control centre immediately. You should also inform the police and fire service without delay. In order to prevent injury and/or damage to property, do not enter a fogged area until visibility permits. Always air premises for at least 20 minutes after a fog cannon has been activated. We recommend airing premises within one hour of a fog cannon having been activated. See the section on cleaning and maintenance. The applicable regulations concerning the installation of fog protection state that at least one verifying PIR sensor is to be installed per fog cannon. Sensors of this kind ensure that the fog cannon only generates fog when both the alarm system and the verifying sensor receive a signal. In this way, it is possible to trigger the alarm without the fog cannon generating fog. It is only when the verifying sensor registers movement in the room where the fog cannon is fitted that the unit will start to generate fog. Typical installation The sensor (2) is a confirmation sensor that is linked directly to the fog cannon.

Important information for users 11 Instructions for intentional activation In order to avoid interaction with a burglar and to prevent the risk of physical injury NEVER enter a fogged area until visibility permits. If appropriate, wait until security personnel have checked and secured the premises. Always air premises for at least 20 minutes after a fog cannon has been activated. We recommend airing premises within one hour of a fog cannon having been activated. See the section on cleaning and maintenance. Interaction between fog protection and fire alarm systems Fire alarms, automatic fire-extinguishing systems (server rooms) and ABDL systems based on sensors that are sensitive to the fog will be triggered by activated fog protection. ION and optical sensors are sensitive to the fog (90% of all installations). Thermal, flame and CO sensors are not. The fire service may be entitled to charge a call-out fee of up to DKK 5,050 (Denmark, 2014) if an ABA system (fire alarm system) is activated by anything other than a fire. However, this does not apply if a passer-by reports the suspicion of a fire on account of activated fog protection. When taking over the new fog protection system in places where a fire alarm system is fitted, you should always require a full-scale test to check interaction between all the systems.

12 Important information for users DON T FORGET! Have you or your alarm company remembered to inform the local police and fire service about your fog protection installation? Annual service PROTECT A/S recommends that you enter into a service agreement with the alarm fitter to make sure that your fog protection system is checked once a year. The areas that such a service agreement should cover are listed in the fog cannon installation manual. The shelf life of fog fluid in unopened packaging is five years, and two years from the date of installation. End users themselves can change the fluid container in PROTECT QUMULUS models sold after 1 September 2014 and the model Xtratus. Fluid containers in all other models must only be replaced by an authorised alarm fitter. Power consumption PROTECT Fog Cannon units consume 5 10 W when the heating element is not switched on. When the heating element is switched on, they consume 60 80 W, which corresponds to the consumption of a conventional light bulb.

Important information for users 13 Failure to comply with the guidelines laid down in these instructions will result in PROTECT A/S waiving all liability for any consequences of same. All certificates, CE declarations, product approvals, etc. are published online at www.protectglobal.com. For additional information, contact the alarm company that fitted the fog cannon, or visit www.protectglobal.com.

PROTECT A/S Hasselager Centervej 5 DK-8260 Viby J Tel.: (+45) 86 72 18 81 info@protectglobal.com protectglobal.com