INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

Similar documents
WALL MOUNTED TYPE ROOM AIR-CONDITIONER

Кондиционеры Mitsubishi Heavy

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

SRK20ZFX-S, 25ZFX-S, 35ZFX-S, 50ZFX-S

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

1. WALL MOUNTED TYPE ROOM AIR-CONDITIONER Split system, Air to air heat pump type

INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONER ( Split system, air to air heat pump type )

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

4. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air to air heat pump type)

WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

(Split system, air to air heat pump type)

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type)

TECHNICAL MANUAL. INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type) SRK25ZJP-S SRK35ZJP-S SRK50ZJP-S

TECHNICAL MANUAL INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS

INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air to air heat pump type)

TECHNICAL MANUAL INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS

TECHNICAL MANUAL. INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type) SRK25ZMP-S SRK35ZMP-S SRK45ZMP-S

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

TECHNICAL DATA & SERVICE MANUAL

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

MITSUBISHI HEAVY INDUSTRIES, LTD.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

TECHNICAL MANUAL. INVERTER MULTI-SPLIT SYSTEM RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type)

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Air Conditioner CONTENTS

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE MANUAL INDOOR UNIT

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

CASSETTE type INVERTER MULTI AIR CONDITIONER

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU9RLQ AOU12RLQ AOU18CL AOU18RL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

TECHNICAL DATA & SERVICE MANUAL

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Room Air Conditioner Service and Parts Manual

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*R07LGC AO*R09LGC AO*R12LGC AO*R14LGC

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

FLOOR CONSOLE / UNDER CEILING DUAL type

TABLE OF CONTENTS. Air Conditioner CS-NE7GKE CU-NE7GKE CS-NE9GKE CU-NE9GKE CS-NE12GKE CU-NE12GKE

FDU71KXE6 FDU90KXE6 FDU112KXE6 FDU140KXE6 FDU224KXE6 FDU280KXE6

SPLIT SYSTEM AIR CONDITIONER

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

MSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

DESIGN & TECHNICAL MANUAL

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

RAS-07EKH/RAS-07EAH RAS-09EKH/RAS-09EAH

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

SERVICE MANUAL INDOOR UNIT. No. OBH788

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

DESIGN & TECHNICAL MANUAL

TECHNICAL & SERVICE MANUAL

Transcription:

TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 -

INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE CONTROLLER - 2 -

1 GENERAL INFORMATION 1.1 Specific features The Mitsubishi Daiya room air-conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment with operation control switch and the outdoor unit is composed of condensing unit with compressor. (1) Inverter (Frequency converter) for multi-steps power control Heating/Cooling The rotational speed of a compressor is changed in step in relation to varying load, interlocked with the indoor and outdoor unit fans controlled to change frequency, thus controlling the capacity. Allowing quick heating/cooling operation during start-up period. Constant room temperature by fine-tuned control after the unit has stabilized. (2) Fuzzy control Fuzzy control calculates the amount of variation in the difference between the return air temperature and the setting temperature in compliance with the fuzzy rules in order to control the air capacity and the inverter frequency. () Remote control flap The flap can be automatically controlled by operating wireless remote control. Air scroll (AUTO): Flap operation is automatically control. Swing: This will swing the flap up and down. Memory flap: Once the flap position is set, the unit memorizes the position and continues to operate at the same position from the next time. (4) Self diagnosis function We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as follows. RUN lamp TIMER lamp Outdoor (LED) 1 time flash Heat exchanger sensor error 1 time flash OFF Outdoor temperature sensor error TIMER lamp ON 2 time flash Room temperature sensor error RUN lamp keeps flashing 2 time flash OFF Outdoor heat exchanger liquid pipe sensor error 6 time flash Indoor fan motor error 4 time flash OFF Discharge pipe sensor error 1 time flash 1 time flash Current cut 2 time flash 2 time flash Trouble of outdoor unit RUN lamp ON time flash time flash Over current 5 time flash 5 time flash Over heat of compressor 6 time flash 6 time flash Error of signal transmission 7 time flash ON Outdoor fan motor error RUN lamp 2 time flash 2 time flash 7 time flash Rotor lock 1.2 How to read the model name Example : SR K 20 Z D - S R410A models Series No. Inverter type Product capacity Wall mounted type Split type room air-conditioner - 1 -

2 SELECTION DATA 2.1 Specifications Item Model SRK20ZD-S Cooling capacity (1) W 2000 (0.5~2.9) Heating capacity (1) W 2700 (0.5~4.7) Power source 1 Phase, 220-240V, 50Hz Cooling input kw 0.44 Running current (Cooling) A 2.4/2./2.2 Heating input kw 0.62 Running current (Heating) A.0/2.9/2.8 Inrush current A.0/2.9/2.8 Operation data (2) COP Cooling: 4.55 Heating: 4.5 SRC20ZD-S Sound level Hi 6, Me 29, Lo 21 44 Cooling Power level 52 58 Noise level db Sound level Hi 8, Me 2, Lo 25 47 Heating Power level 54 61 Exterior dimensions Height Width Depth mm 250 815 249 540 720 290 Color Cool white Stucco white Net weight kg 9.0 2 Refrigerant equipment Compressor type & Q ty RM-B5077MD1 (Rotary type) 1 Motor kw 0.75 Starting method Line starting Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Refrigerant () kg R410A 0.9 (Pre-Charged up to the piping length of 15m) Refrigerant oil R 0.5 (MA68) Deice control Microcomputer control Air handling equipment Fan type & Q ty Tangential fan 1 Propeller fan 1 Motor W 29 24 Air flow (at High) (Cooling) 7.0 0 CMM (Heating) 8.5 25 Air filter, Q ty Polypropylene net (washable) 2 Shock & vibration absorber Cushion rubber (for compressor) Electric heater Operation control Operation switch Wireless-Remote controller Room temperature control Microcomputer thermostat Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange) Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection, Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection Refrigerant piping Model O.D mm (in) Liquid line: φ6.5 (1/4 ) Gas line: φ9.52 (/8 ) Connecting method Flare connecting Attached length of piping Liquid line: 0.47 m Gas line : 0.40 m Insulation Necessary (Both sides) Connectable 2.5 m ( cores with Earth) Size Core number 1.5 mm 2 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) Mounting kit Drain hose Power source cord Connection wiring SRK20ZD-S (Indoor unit) SRC20ZD-S (Outdoor unit) Accessories (included) Optional parts Notes (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB Standards Cooling 27ºC 19ºC 5ºC 24ºC ISO-T1, JIS C9612 Heating 20ºC 7ºC 6ºC ISO-T1, JIS C9612 The piping length is 7.5m. (2) The operation data are applied to the 220/20/240V districts respectively. () The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping. (Purging is not required even for the short piping.) - 2 -

2.2 Range of usage & limitations Item Indoor return air temperature (Upper, lower limits) Outdoor air temperature (Upper, lower limits) Refrigerant line (one way) length Vertical height difference between outdoor unit and indoor unit Model SRK20ZD-S Refer to the selection chart Max. 15m Max. 10m (Outdoor unit is higher) Max. 10m (Outdoor unit is lower) Power source voltage Rating ± 10% Voltage at starting Frequency of ON-OFF cycle ON and OFF interval Min. 85% of rating Max. 10 times/h Max. minutes 2. Exterior dimensions (1) Indoor unit Model SRK20ZD-S Unit: mm A 815 249 Piping hole right(left) 117.5 580 117.5 216.5 450 148.5 148.5 450 216.5 8.2 42.7 175 47.2 250 9 60 Terminal block 45 150 56 18 44.5 5.5 67.5 44.5 26.1 5.7 5 60 Remote controller 788 60 14.5 Piping for Gas 97.1 (ø9.52) 45 45 Piping for Liquid 465.1 (ø6.5) Drain hose 540 (ø16) Piping hole (ø65) Piping hole (ø65) VIEW A - -

(2) Outdoor unit Model SRC20ZD-S Unit: mm Drain holes 290 540 14.4 47.4 42.6 71 264.5 404.5 510 720 50 12 17.8 14 12.5 1.5 40 19 2-16x12 61.9 99.9 9.7 Terminal block 19.. 40 Service valve (Liquid) Flare connection ø6.5 (1/4") 40 Service valve (Gas) Flare connecting ø9.52 (/8") 2.4 Piping system Model SRK20ZD-S Indoor unit Flare connecting Outdoor unit Service valve (Gas) Cooling cycle Heating cycle Outdoor air temp. thermistor Piping (Gas) ø9.52 Check joint 4 way valve Accumulator Room temp. thermistor Heat exchanger Heat exchanger thermistor Discharge temp. thermistor Compressor Heat exchanger Heat exchanger thermistor Piping (Liquid) ø6.5 Service valve (Liquid) Capillary tube Capillary tube Flare connecting Strainer Electronic expansion valve - 4 -

2.5 Selection chart Correct the cooling and heating capacity in accordance with the conditions as follows. The net cooling and heating capacity can be obtained in the following way. Net capacity = Capacity shown on specification Correction factors as follows. (1) Coefficient of cooling and heating capacity in relation to temperatures 1. Coefficient of cooling & Heating capacity in relation to temperature 1.2 1.1 1.0 0.9 0.8 Cooling Heating 0.7 0.6 Applicable range Cooling operation Outdoor air D.B. temperature C D.B. 4 40 5 0 25 20 15 24 14 16 18 20 22 Indoor air W.B. temperature C W.B. ISO-T1 Standard Condition Heating operation Indoor air D.B. temperature C D.B. 27 25 20 15 10-10 -5 0 5 10 15 20 Outdoor air W.B. temperature C W.B. ISO-T1 Standard Condition (2) Correction of cooling and heating capacity in relation to one way length of refrigerant piping It is necessary to correct the cooling and heating capacity in relation to the one way piping length between the indoor and outdoor units. Piping length [m] 7 10 15 Cooling 1.0 0.99 0.975 Heating 1.0 1.0 1.0 () Correction relative to frosting on outdoor heat exchanger during heating In additions to the foregoing corrections (1), (2) the heating capacity needs to be adjusted also with respect to the frosting on the outdoor heat exchanger. Air inlet temperature of outdoor unit in C WB -10-9 -7-5 - -1 1 5 Adjustment coefficient 0.95 0.94 0.9 0.91 0.88 0.86 0.87 0.92 1.00 How to obtain the cooling and heating capacity Example : The net cooling capacity of the model SRK20ZD-S with the piping length of 15m, indoor wet-bulb temperature at 19.0 C and outdoor dry-bulb temperature 5 C is Net cooling capacity = 2000 0.975 1.0 = 1950 W SRK20ZD-S Length 15m Factor by air temperatures - 5 -

- 6 - Power source 1 Phase 220-240V 50Hz BR BL Y/GN HEAT EXCHANGER FMI SM RD BK WH Y BL 52C4 1 4 5 6 CNU CNM 52C 52C F1 250V.15A ( ) CNE N J 52C Printed circuit board ZNR CNG Indoor unit BK WH RD TB 1 2 TB 1 2 Outdoor unit BK WH RD Y/GN F2 (250V 20A) C2 S.IN R.IN DS G Printed circuit board CNB CNE CNA Re 20S EEV FMo Model SRK20ZD-S.1 Electrical wiring ELECTRICAL DATA Color symbol BK BR RD BL WH Y/GN Black Brown Red Blue White Yellow/Green Display Wireless R-Amp Th1 Th2 CM RD WH BK U V W N Power transistor P CND Th4 Th5 Th6 Meaning of marks Symbol Parts name CM F FMI FMo SM RE Compressor motor Fuse Fan motor (Indoor) Fan motor (Outdoor) Flap motor Reactor Symbol Th1 Th2 Th4 Th5 Th ZNR 6 Parts name Room temp. thermistor Heat exchanger thermistor (Indoor unit) Heat exchanger thermistor (Outdoor unit) Dischar Outdoor air temp. thermistor ge temp. thermistor Varistor Symbol 20S 52C DS EEV Parts name 4 way valve (coil) Magnetic contactor Diode stack Electronic expansion valve

4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER 4.1 Operation control function by remote control switch Remote controller Models All models S Operation section FAN SPEED button OPERATION MODE select button Each time the button is pushed, the indicator is switched over in turn. HI POWER button This button changes the HI POWER mode. AUTO HI MED LO HI POWER ON AM ECONO PM OFF Each time the button is pushed, the indicator is switched over in turn. ON/OFF button Press for starting operation, press again for stopping. AIR FLOW button This button changes the flap mode. When pressed, this button changes the mode in the following order: FAN SPEED ON OFF MODE HI POWER TEMP ECONO AIR FLOW ECONOMY button This button changes the ECONOMY mode. (Air scroll) (SWING) TIME CANCEL ON OFF RESERVE TIMER TIME ACL TEMPERATURE button This button sets the room temperature. (This button changes the present time and TIMER time.) ON TIMER button This button selects ON TIMER operation. CANCEL button This button cancels the ON timer and OFF timer. Clock switch This switch for setting the clock. OFF TIMER button This button selects OFF TIMER operation. The above illustration shows all controls, but in practice only the relevant parts are shown. RESERVE button This button sets the present time and TIMER time. RESET switch Switch for resetting microcomputer. S Indication section HI POWER MODE indicator Indicates during Hi power mode operation. TEMPERATURE Indicator Indicates set temperature. (Does not indicate temperature when operation mode is on AUTO) AUTO HI MED LO HI POWER ON AM ECONO PM OFF ECONOMY MODE indicator Indicates during economy mode operation. OPERATION MODE Indicator Indicates selected operation with lamp. [ (Auto) (Cool) (Heat) (Dry)] Clock Indicator FAN SPEED Indicator Indicates present time or timer setting time. Indicates set air flow rate with lamp. OFF TIMER Indicator AIR FLOW Indicator Indicates OFF TIMER operation. Shows selected flap mode. ON TIMER Indicator Indicates during ON TIMER operation. - 7 -

Unit indication section Models All models RUN (HOT KEEP) light (green) Illuminates during operation. Flashes at air flow stop due to the HOT KEEP. TIMER light (yellow) Illuminates during TIMER operation. HI POWER light (green) Illuminates during HI POWER operation. ECONOMY light (orange) Illuminates during ECONOMY operation. - 8 -

5 INSTALLATION R410A refrigerant is used for this air-conditioner. Execute the installation work while taking care of the following points in addition to the general caution items. 5.1 Installation tools Prepare the following special tools for R410A in addition to the general-purpose tools. Flare tool Vacuum pump adaptor Gauge manifold Leak detector Charge hose 5.2 Refrigerant piping Use the copper pipe that has less than 40 mg/10 m of oil adhesion and 0.8 mm of wall thickness. Never use the thin walled pipe the thickness of which is less than 0.8 mm. Use the flare nut attached to the air-conditioner. 5. Pipe connection (1) Pipe working Copper pipe dia. Liquid side ø6.5 ø9.52 Gas side ø12.7 Dimension "A" (mm) 9.1 1.2 16.6 Flare tool bar Dimension "B" Copper pipe Copper pipe dia. ø6.5 ø9.52 ø12.7 Dimension "B" (mm) Clutch type flare tool for R410A 0.0 ~ 0.5 0.0 ~ 0.5 0.0 ~ 0.5 (2) Tightening torque The tightening torque is shown below. Copper pipe dia. Liquid side ø6.5 ø9.52 Gas side ø12.7 Across flats of flare nut (mm) 17 22 24 Tightening torque N m (kgf m) 14 ~ 18 (1.4 ~ 1.8) ~ 42 (. ~ 4.2) 50 ~ 62 (5.0 ~ 6.2) () Vacuuming The charge hose for R22 cannot be connected because the service port diameter is different from the conventional one. Use the special charge hose for R410A. Use the vacuum pump adapter for reverse flow prevention to check the reverse flow of vacuum pump oil. If oil flows back to the air-conditioner, it causes failure of refrigerant cycle. Service valve (Two-way) -101kPa (-76cmHg) Compound pressure gauge Handle Lo Service valve (-way) Charge Hose Service Port (Special for R410A) Pressure gauge Handle Hi Gauge manifold (Special for R410A) Charge hose (Special for R410A) Vacuum pump adaptor (For reverse flow prevention) (Special for R410A) Vacuum Pump - 9 -

PARTS LIST (Main parts) (1) Indoor unit No. 1 2 4 5 6 7 8 9 Parts Name PANEL ASSY, FRONT PANEL, FRONT PANEL, AIR INLET GRILLE ASSY, AIR OUTLET MOTOR, DC IMPELLER HEAT EXCH ASSY (AIR) PWB ASSY CONTROL ASSY, REMOTE Parts No. SRK20ZD-S RKV102A600 RKV122A001G RKV45A100B RKV45A101B SSA512T064 SSA41G042C RKV01A500G RKV505A001CG RMA502A001 PARTS LIST (Main parts) (2) Outdoor unit No. 1 2 4 5 6 7 8 9 10 11 12 1 14 15 Parts Name PANEL, FRONT PANEL, SIDE (R) PANEL, TOP GRILLE, AIR OUTLET BRACKET, MOTOR MOTOR, DC PROPELLER BASE ASSY HEAT EXCH (AIR) VALVE, S (4WAY) COIL, SOLENOID COMPRESSOR ASSY PWB ASSY VALVE, BODY (EXP) COIL, SOLENOID Parts No. SRC20ZD-S RCP122A001 RCP12A001 RCP124A001 RCP45A001A RCP116A001 SSA512T08D SSA41B212 RCP111A001 RCP11A001G SSA82C077 RSA82F010B AHT201A864D RCP505A101F SSA87F01 SSA82F210A - 10 -

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER Air-Conditioning & Refrigeration Systems Headquarters 16-5, 2-chome, Kounan, Minato-ku, Tokyo, 108-8215, Japan Fax : (0) 6716-5926 - -