Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Similar documents
Belt Driven Mixed Flow Fans

JM Aerofoil Fans Bulletin JMA60-05

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Introduction to Fans. The Basics of Fan Principles and Terminology

Selecting the Correct Fan

A. Codes and Standards that are Standard at the University:

SECTION (15833) - HVAC POWER VENTILATORS

Fans: Features and Analysis

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Axial flow fan AXICO ANTI-STALL

MARLOW PUMPS RECIRCULATION

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Ducted Propeller. Airflow Volume

Bulletin FH05 FUME EXHAUST

Modular Supply Make-Up Air Unit

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Twin City Fan & Blower

University of Houston Master Construction Specifications Insert Project Name

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

SECTION AIR HANDLING UNIT

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION AXIAL FANS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Dean Pump High Temperature Chemical Process Inline Pumps

Industrial Fans & Blowers

Wilo IL Vertical Split-Coupled Inline Pumps

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Centrifugal Fans, Non-Overloading, Backward Inclined

Direct Fired Heater Model AD Specification

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

1.1 This section applies to air handling units for HVAC Systems.

Modular Heating & Ventilating Unit Model IGX-HV

Axial Flow Fans Good Design Guide

Twin City Fan & Blower

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

SECTION AIR COILS

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Contents INDEX. TDM Series Indirect Fired Heaters

Multistage Centrifugal Blowers

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

THREE-WAY HEAT SAVER/VENTILATOR

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

GA Gas Unit Heater Assemblies Technical Guide

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

Horizontal Split Case Pumps Type U

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Rotodynamic Pumps INTRODUCTION:

Multistage Centrifugal Blowers

A. This Section includes air-handling units with coils for indoor installations.

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Multistage Centrifugal Blowers

an ISO 9001 Company Bulletin PR-112

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Tunnel Axial Flow Fan

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION STEAM CONDENSATE PUMPS

FAS Fresh Air Supply Units

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

DAE Systems. Fan Selection Guide. Section 1: Terminology

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Centrifugal Blower. Backward/Aerofoil Curved.

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

Goulds LP3400 Series Low Pulse Fan Pumps

Plenum Fans. Model HPA. Direct Drive

Indirect Gas-Fired Make-Up Air

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Transcription:

www.howden.com Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Evase Vaneaxial fans by Howden can save energy over the installed life of the system by recovering the kinetic energy contained in the high velocity airstream s mass. These fans work just as hard as the normal fans that you are accustomed to and then go on to recovery energy by converting the velocity pressure in the system into static pressure by means of a built-in discharge cone. It s now not necessary to specify a discharge cone for your system, therefore reducing the fan s overall footprint. With this fan installed in your system, air velocity is low enough for outlet damper and shutters to operate without fear of these relatively sensitive components being destroyed by high velocity flutter. How it works The energy contained in the moving airstream is converted to static pressure by means of a cone, which allows the diffusion of the high velocity airstream to slow to a lower rate. This causes an effective conversion of velocity pressure into static pressure. When applied to the installation, the resulting reduced static pressure allows the fan system to perform more efficiently at reduced static pressures, with resulting lower energy consumption. Howden s Evase fan design incorporates integral stationary anti-rotation guide vanes to enhance the regain effect by slowing the rotation imparted to the airstream by the fan impeller and recovering rotational energy losses, while reduces fan noise generation. A separately formed Impeller Casing is used to insure uniform minimal tip clearance for full pressure development. Evase vaneaxial fans Page 2 of 5

To Select an Evase Fan 1. Design the fan system as per usual 2. Using the Howden Selection Program, or technical literature, make a preliminary selection for a JMG Vaneaxial Fan. 3. From the chart on the next page determine the amount of static regain for the fan size selected. 4. Subtract the regain from the system static requirement and re-select the fan 5. Specify the fan: Model Number EV (denoting an Evase fan) CFM Fan Diameter Impeller Pitch Fan Speed Fan Total Pressure Fan Static Pressure Motor HP Fan BHP Regain Data Use the chart above to determine the regain available from the Evase housing construction. Then select the JMG fan for your application using Howden American Fan s selection software or published fan curves. Rugged. Flexible. Efficient. Evase vaneaxial fans Page 3 of 5

Vaneaxial Fans Fans shall be Howden JM Evase Vaneaxial Fans, as manufactured by Howden Fans shall be Arrangement 4, direct motor driven with the fan impeller mounted on the motor shaft and supported by the motor bearings. Performance Fan performance shall be based on tests conducted in accordance AMCA 210 test code for air moving devices and shall be guaranteed by Howden American Fan Company to deliver rated published performance levels within permitted tolerances. Construction Fan casing shall be of welded two-piece construction, consisting of an impeller duct and a motor and guide van evase section. Drilled inlet and outlet flanges are standard and shall be integrally rolled or solid welded to insure a leak-proof casing. Fans above size 100 shall be equipped with built-in sling lifting eyes to facilitate shipment and on-site handling. Furnish an inspection port in the casing to observe fan rotation. A precisely formed impeller housing designed for minimum impeller clearance shall be used in the construction of the fan. A conical guide vane section shall enclose the fan motor and permit the recovery of high velocity airstream energy. Vanes shall be precisely located and attached to both the housing and the drive motor and act to straighten the tangential component of the air movement downstream of the impeller blades, thereby converting rotational energy losses to pressure, improving efficiency and static pressure capability and reducing power requirements. Impeller The impeller shall consist of high-pressure die cast aluminium airfoil blades, hub and clamp plate. The impeller shall be manually adjustable through the full range of pitch angles. All impeller components are to be inspected using real time radiography, and examines to ASTM E-155, prior to machining to assure casting integrity and quality. Impellers shall be precision balanced as a fan assembly to minimise vibration levels and assure smooth operation. Conversion (guide) vanes shall be matched to impeller design for improved efficiency and decreased noise output. Motor Motors for fans shall be manufactured in accordance with current applicable standards of IEEE and NEMA and, where applicable, shall meet at least current EPACT standards for efficiency level. Motors shall be pad-mounted, NEMA standard TEAO-enclosed, continuous duty, ball bearing type with class F insulation and of cast iron construction when commercially available. Finish The entire fan assembly, excluding the impeller, shall be thoroughly cleaned before application of the finish coat. Prior to assembly, all steel parts shall be primed and then painted with a finish coat of gloss alkyd enamel shall be applied to a dry film thickness of 2.0 mils minimum and oven-dried. Enamel shall be mercury-, lead-, and chromate-free. Aluminium components shall be unpainted. Factory Run Test All fans with motors and drives mounted by Howden shall be completely assembled and test run as a unit at the specified operating speed prior to shipment. Records shall be maintained and a written copy shall be available upon request for a minimum of seven (7) years. Evase vaneaxial fans Page 4 of 5

www.howden.com At the heart of your operations Howden people live to improve our products and services and for over 160 years our world has revolved around our customers. This dedication means our air and gas handling equipment adds maximum value to your operations. We have innovation in our hearts and every day we focus on providing you with the best solutions for your vital operations. Howden American Fan Company 2933 Symmes Rd Fairfield OH 45014-2099 Tel: 1-866-771-6266 Fax: 1-513-870-6249 Email: haf.sales@howden.com Howden Group Limited. All rights reserved. 2016 Howden and the flying H logo are registered trademarks belonging to Howden Group Limited