JAG group microwave manual. (updated October ) Table of contents. 1 General information 2. 2 General safety rules 2. 3 The microwave reactor 3

Similar documents
Custom Products for Research. Kugelrohr Short Path Distillation

KEM Scientific, Inc. Instruments for Science from Scientists

CEM Discover Microwave

CEM MARS5 Microwave Updated November 13, 2017

Asynt Air Condenser Evaluation

CEM Mars 5 Microwave Accelerated Reaction System

University of Minnesota Nano Fabrication Center Standard Operating Procedure

APPENDIX A: MICROSCALE APPARATUS AND TECHNIQUES A.1 CRAIG TUBES: RECRYSTALLIZATION

Autoclave Operations Manual

Premium Laboratory Equipment. Chem Tools

Glovebox Usage Manual v1.4. When you enter the lab walk straight to the log book. Enter all information including N2 and O2/H2O levels.

3D_ISS. Integrated Software System. User Guide Manual

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Plasma-Therm 790 RIE (Reactive Ion Etcher) Basic Operation Guide

Symphony Quick Start Manual Document: Revision: A Distek Inc. Quick Start Manual

MiniWAVE Microwave Digestion Made Easy

Skipper's Mate. Sensor Testing. Version December Table of Contents

Standard Operating Manual

Dryer Controller M720

User Manual. Dryer Controller M720

Automatic Distillation testing. Innovation in distillation. by Orbis BV.

Welcome to MultiSight TM Vision Sensor Hands-On Lab

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

OPERATING INSTRUCTIONS. G214 Software - Version 4

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

860 KF Thermoprep. Manual EN

Experiment 4: Purification of Liquids by Distillation

Tips how to use the MAS Web tool

Galaxy. Galaxy Robot Sampler Page 1

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Wacker Neuson Instruction Guide: Revision 6

User Guide UTI-IQCP. Control panel for setting and monitoring of UTI-INV internal temperature regulator. v EN

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

RINS App User Guide. Connect to your home or business from anywhere in the world.

Environmental Express, Inc. AutoBlock Plus Operation Manual and Instructions CONTENTS. i. Introduction/General Information 2

Instructions for using the PerkinElmer DSC-8500

Cleaning Procedures in ICP-MS Laboratories

In order to be useful, many substances must be available in pure form.

Sensor Control Panel

NorthStar. System Requirements. Quick Install Guide

Standard Operating Manual

Security Management System - Configuring Video Analytics

ProStar 325 UV-Vis Detector

Systems. Visit us at

PowerLogic ION Setup Meter Configuration Software Configuration Guide

HI COD REACTOR and Test Tube Heater 2008 Series

Safe. Heating and Mixing. Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership

Temperature Control for Research and Industry. Model 280 Timer Manual

TV2 Clean Room Monitor

Standard Operating Procedure Glovebox and Thermal Evaporator

TV2 Room Pressure Monitor Quick Start Guide

RD-500V RD-500SV ESD SMT REWORK SYSTEM

QK-IR2005. User s Manual

7:00AM 1:00AM ET 7:00 AM 12:00AM ET

Temperature Control for Research and Industry. Model 270 Manual

INDOOR CLIMATE OF A SINGLE ZONE

Milestone XProtect. Central 3.7 User s Manual

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

MB-T Moisture analyzers

Temperature Control For Research and Industry. Gemini User s Manual

behr Labor-Technik Kjeldahl method for determining nitrogen

Chemistry - Tools for chemistry

245 * Lab #4 Steam Distillation of Orange Oil

[ [ ADMIN PANEL USER GUIDE

I760B-DX BGA Rework System. Operation Manual

User Manual. TN6900 H&E Slide Stainer. Read Prior to Operation! Always keep this manual near the unit! WP

JOVY SYSTEMS RE User Manual Rev. 1.00

Standard Operating Procedure: Spinner

Before you install ProSeries Express Edition software for network use

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Follett Performance Plus

Digital MFC software V1.10

Temperature Control for Research and Industry. Model 360/Timer Manual

A Issue 3. USA Distributor:

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Syringe Pump. User Manual

Ingenieurbüro M.ZippererGmbH

THERMAX Efficiency Monitor

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

University of Minnesota Nano Fabrication Center

Cent$ible Power Users Manual

Fractional Distillation for the Laboratory and Industry

User Manual System 11

HBC-4301 Hot Bonding Controller. Operators Manual

Installing ProSeries software for stand-alone use

Installing ProSeries 2005

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Temperature Control for Research and Industry. Apollo Dual Channel Temperature Controller User s Manual

User Manual SPI-P170 Hydrogen Peroxide

i-vu CCN 4.0 Owner s Guide

Photo 5 Photo 6 Note: Once you connected the dehumidifier to the local network you can install the app on any other mobile phones and use Scan QR key

Platinum Touch/Rotem One Touch

Electronic Pellet Burner Controller NPBC-V3-1

Laptop / PC Programming Manual

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Safe Heating and Mixing

Transcription:

JAG group microwave manual (updated October 4 2016) Table of contents 1 General information 2 2 General safety rules 2 3 The microwave reactor 3 3.1 Setup 3 3.2 Getting started 4 4 Reactions under pressure 5 4.1 Reaction tubes 5 4.2 Safety rules and information 5 4.3 Setup 6 4.4 Login 7 4.5 Parameter window 8 4.6 Edit window 8 4.7 Run menu 9 5 Reactions with refluxing solvents 11 5.1 Setup 11 5.2 General safety rules 12 5.3 Setup information 12 6 Appendix 13 1

1 General information: Administrator password: 654321 Maximum capacity: 1000 W in 10 W increments Microwaves: f = 2.45 GHz, λ = 12.25 cm Built-in exhaust system. Maximum exhaustion: 108 m 3 /h Built-in IR sensor for temperature control Built-in automatic stirring 2 General safety rules: All general safety rules for reactions under pressure apply When doing reactions under pressure nobody should stand directly in front of the door of the microwave reactor. The danger is reduced when the pressure drops below 10 bar or 150 C. Do not mix heavily oxidizing compounds with volatile solvents. This machine currently has no pressure control unit. Always estimate the pressure at the desired temperature (look up vapor pressure table for specific solvent), and don't max out. It's always safer to stay slightly below the maximum pressure allowed for the vessel. Always have the QP-sensor running. This sensor checks for chemicals leaking into the reaction chamber. Always check the containers for cracks and stars before you do a reaction under pressure. Always check and follow the temperature in the reaction chamber while the reaction is running. The maximum amount of solvent is 200 ml. The use of stir bars to distribute the energy in the flask and to prevent superheating is strongly encouraged. When performing a reaction with refluxing solvents always have the equipment open after the condenser to prevent pressure building up. 2

3 The microwave reactor 3.1 Setup A. Air suction hole for ventilation of the reaction chamber B. Lead-through for temperature probe C. Connection of temperature probe with computer D. Glass tube for safe-keeping of the temperature probe while not in use. E. Power converter A. main door to reaction chamber B. ON/OFF switch C. Manual control for stirrer D. Control screen E. Exhaust tube to hood F. Keyboard and mouse 3

3.2 Getting started: 1. Plug in the cables of the power converter. The orange light should glow. 2. Plug in the cable of the microwave reactor into one of the two plugs at the front of the power converter. 3. Switch on the power supply on the power converter (left) and finally switch on the microwave reactor (right). 4

4. Reactions under pressure 4.1 Reaction tubes: Reactions under pressure are performed in sealed microwave reactor tubes for a maximum pressure of 4.5 bar or 15 bar. 1 Pressure control cap with red (15 bar) or green (4.5 bar) mark 2 Vial cap 3 Glass/Quartz container with protective coating 4 Valve 5 Thermo probe valve (the temperature probe T1 is inserted here). Note: the reaction mixture must be filled high enough to touch the thermo probe valve. 4.2 Safety rules and information - NEVER use the glass containers with the red cap, glass is only good for 4.5 bar, use Quartz for pressures above 4.5 bar - The maximum temperature is 250 C - Always check the containers for cracks prior to use. - Do not use aggressive or strongly basic reagents. - Make sure that you are stirring sufficiently, especially if using the IR sensor (T2), since high differences in the heat distribution and/or superheating may occur. - When applying high heating rates (more than 5 C/min) you must use the internal temperature probe (T1). NOTE: currently not functional, use IR sensor instead 5

4.3 Setup The reaction tubes are placed in the Teflon holder (A) and secured with a Teflon cap (B). A plastic tube (D) cares for ventilation and the temperature probe (C) and an IR sensor (E) control the temperature. 1. Place the reactor tube in the Teflon holder. 6

2. Close with the Teflon cap. 3. Place the plastic tube in the lower opening of the Teflon holder (A) and connect the thermo probe with the sensor (B). 4.4 Login 4. Log in the easycontrol program. 5. Click on the pressprep button (top right) and you ll find three submenus: method, sample, and run. 7

4.5 Parameter window 6. Click on method and either parameter or edit to find the load button on the bottom of the screen (third icon from the right). Here you can load an old method. You can save modified methods by pressing the save button (second from right). The first button from the left is the one for the QP-check, the second for the stirring test, and the third button activates the ventilation of the reaction chamber. Methods can be opened, edited and saved from both the parameter and the edit window. A method can either be controlled for T1 or T2. 4.6 Edit window 7. In the edit mode you can generate or edit the method and add as many steps as you wish. You can change: - The time period (t) of a step. - The maximum power of the irradiation (E(W)). If another value (e. g. the temperature) reaches its maximum, the power is set to 0. - The temperature T1-limit, if you enter 0 there will be no regulation by T1. - Temperature T2-limit, if you enter 0 there will be no regulation by T2. You can change the period of irradiation either by pulling the arrow on the top part of the screen or by entering it via keyboard. 8

8. If you want to generate a new method, click on the empty page icon. Enter the period of the first step of the method and new steps for this method are activated and can be edited. If you want to leave one entry undefined enter 0. 4.7 Run menu 9. In the run menu you can start the method and follow the power and temperature while the microwave oven is running. 10. To start your method press the start button in the bottom right corner. Before the method starts you will be asked what stirring power you would like to use. After a 5 s preheating time the first heating step of the method starts. You can always abort the method by hitting the stop button which replaces the start button in the bottom right corner. - While the microwave method is running the software records all temperature and power values in real-time. By clicking on the T1-, T2-, E, P-, or QP-button you can show or blind out the respective value. - Clicking on pause will halt the program without aborting it. If you use the pause button a P will appear in the graph. Opening the door has the same effect. - The scales for temperature and power are located in the lower left corner. These values can be adjusted anytime. 9

- After activating the power average button ( E/T ) you can chose a time interval and the average power value will be calculated for this interval. - You can zoom in the graphs by drawing a rectangle with the mouse cursor. - On the top you can see the current parameter values (red) followed by the values of the position marked by the cursor (blue). 10

11

11. When your reaction is done let the vessel cool down to room temperature. Make sure that the overpressure valve is pointing away from you when you open the valve. 5. Reactions with refluxing solvents: 5.1 Setup Reactions under reflux are performed in standard three-neck round bottom flasks equipped with a standard reflux condenser. The flask (A) is placed on a Teflon block. The temperature probe (B) is attached to the flask via an adapter. Make sure that it reaches the level of the solvent. A long glass tube (C) connects the flask with the reflux condenser (D) outside the microwave oven. 12

5.2 General safety rules - All safety rules for reactions under reflux conditions apply. - Don t forget to place a stir bar in the flask to help distributing the heat in the flask. - The use of the temperature probe (T1) is recommended, but IR sensor (T2) is OK. - The amount of solvent must not exceed 200 ml. - Direct fumes from the reaction chamber to the hood. 5.3 Setup step by step 1. Set up your flask and hardware as usual. Load the flask with all starting materials and solvent(s). Attach the temperature probe (T1) to the flask via an adapter, if used. 2. Attach the long glass tube to the middle joint of the three-neck flask. 3. Install the reflux condenser on top of the glass tube, attach tubing to the water line, and direct fumes to the hood. For high boiling solvents cooling water is not always necessary. 4. Let the reaction run as long as necessary and follow the power and temperature on the screen. 5. Let the flask cool down and work up the reaction mixture as usual. 13

6 Appendix This happens if you apply too much power and don t watch your reaction. Conclusion: Don t let your reaction unattended especially if you are applying high power. $5000 14