GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Similar documents
FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. Visit taxcredit for complete details.

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Ruud Acheiver Series Upflow Gas Furnaces

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

Multi-Position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Multi position Gas Furnaces

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE

Multi-Position Gas Furnaces

OIL FURNACES PREMIUM CLASS UPFLOW OIL FURNACES. ROBF- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to kw]

Rheem Classic Series Multi-position Gas Furnaces

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

INTEGRATED HVAC & WATER HEATING

Ruud Ultra Series EcoNet Enabled Two-Stage Variable Speed Multi- Position Gas Furances

TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

TECHNICAL SPECIFICATIONS

Hydronic Air Handler Powered by Tankless Technology

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FG7T (C and L Series)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Hydronic Air Handler Powered by Tankless Technology

RG7D 1-Stage Heat Series

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TECHNICAL SPECIFICATIONS

Comfort, Quality and Efficiency.

Hydronic Air Handler Powered by Tankless Technology

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Energy Saving. Space Saving.

Rheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

G34M Bulletin #69/ August 2003

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Wt. Lbs Model Number (BTUH) Hz

Cooling Capacity CFM in. w.c. (125 Pa)

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

MERIT SERIES Downflow

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

395CAV Sizes 045 thru 155 Series H and J

Cooling Capacity CFM in. w.c. (125 Pa)

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Transcription:

FORM NO. G22-473 REV. 3 Supersedes Form No. G22-473 Rev. 2 GAS FURNACES UGPL- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR [15 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency - AFUE THIS MODEL 80.0% ENER UIDE MID 78% 82% 88% 97% SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPF/HORIZONTAL GAS FURNACES The Ruud Silhouette II Plus 2 LXE line of upflow/horizontal gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the Silhouette s low-profile 34 inch [864 mm] height, the upflow model installed vertically can also be used to satisfy most applications that traditionally call for a horizontal furnace. The design is certified by CSA International. Features Patented Heat Exchanger, constructed of both stainless and aluminized steel for the maximum in corrosion resistance. Low profile 34 inch [864 mm] design is lighter and easier to handle, and leaves room for optional equipment. Energy efficient and quiet ECM 2+ motor. Improves cooling efficiency when matched with rated condensing unit and coil. Constant CFM. Dip switch settings for selectable heating temperature rise and cooling airflow. On-demand dehumidification terminal for improved comfort in cooling mode. Convertible from upflow to horizontal left or right without field conversion. Left or right side gas and electric inlet connections. All models equipped with remote sense feature, an integrated board with humidifier and electronic air cleaner hookups. Insulated blower compartment, a slow-open gas valve, a specially designed draft inducer motor and blower motor make it one of the quietest furnaces on the market today. Pre-paint galvanized steel cabinet. Molded permanent filter. Grab-holes in doors to aid in easy door removal and replacement. Compatible with single or two-stage thermostat. (For optimal performance, two-stage thermostat recommended.) A variety of cooling coils and plenums designed to use with Ruud Silhouette II Plus 2 LXE gas furnaces are available as optional accessories. A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

RUUD SILHOUETTE II PLUS 2 LXE TWO STAGE 80% UPF/HORIZONTAL GAS FURNACE Two-Speed Draft Inducer Motor Heat Exchanger In-Shot Burners Direct Spark Ignitor Remote Sensor Integrated Furnace Controls ECM Motor STANDARD EQUIPMENT Completely assembled and wired; 2 speed draft inducer; high and low pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; fused protection (secondary), 3rd speed fan option for continuous fan. OPTIONAL EQUIPMENT Side filter frame assembly. Return air cabinet for all sizes. (See Page 6) NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. All models can be converted by a qualified Ruud distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Ruud parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 2 Ruud Air Conditioning Division

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS (UPF) U.S. AND CANADA MODELS MODEL NUMBERS UGPL- SERIES 05EBMKR 05NBMKR 07EBRKR 07NBRKR 07EBRQR 07NBRQR 10EBRMR 10NBRMR 12EARMR 12NARMR High Input BTU/Hr [kw] ➁ 50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29] 125,000 [37] Heating Capacity BTU/Hr [kw] ➀ 40,900 [12] 61,280 [18] 61,280 [18] 81,470 [24] 101,660 [29] Low Input BTU/Hr [kw] 35,000 [10] 52,500 [15] 52,500 [15] 70,000 [20] 87,500 [25] Heating Capacity BTU/Hr [kw] 28,000 [8] 41,600 [12] 41,600 [12] 56,000 [16] 70,080 [20] Heating Ext. Static Pressure [kpa].10 [.025].12 [.029].12 [.029].15 [.037].20 [.05] Blower (D x W) [mm] Temperature Rise Range F [ C] 11 x 7 [279 x 178] 25-55 [13.9-30.6] GENERAL TERMS OF LIMITED WARRANTY Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. 30-60 [17-33] 40-70 [22.2-38.9] ECM Motor H.P. [W] 3/4 [559] 1/2 [373] 3/4 [559] 1 [746] 1 [746] Motor Full Load Amps. 9.6 7.7 9.6 12.8 12.8 Unit Amps 8.7 8.7 12.0 12.0 12.0 Maximum Overcurrent Protection 15 15 15 15 15 Heating Speed CFM High Fire [L/s] 860 [405] 1060 [500] 1060 [500] 1320 [623] 1890 [892] Heating Speed CFM Low Fire [L/s] 648 [306] 700 [330] 700 [330] 942 [445] 1296 [573] Cooling CFM @.5" [kpa] E.S.P. (Nominal) [L/s] 1200 [566] 1200 [566] Max. E.S.P. (In. W.C.) [kpa] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] 2000 [944] 2000 [944] 35-65 [19.4-36.1] Max. Outlet Air Temp. F [ C] 155 [68.3] 170 [76.6] 170 [76.6] 170 [76.6] 180 [82.2] Standard Filter Size Inches [mm] Return Air Cabinets (Opt.) RXGR- Filter Size [mm] 15 3 /4 x 25 [400 x 635] C17B (2) 12 x 16 [305 x 406] 19 1 /4 x 25 [489 x 635] C21B (2) 20 x 16 [508 x 406] 30-60 [17-33] 19 1 /4 x 25 [489 x 635] C21B (2) 20 x 16 [508 x 406] 22 3 /4 x 25 [578 x 635] C24B (2) 24 x 16 [610 x 406] AFUE ➀ 80.5% 80.3% 80.3% 80.0% 80.0% ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form for high altitude derate. 1600 [755] 19 1 /4 x 25 [489 x 635] Approx. Shipping Weight (Lbs.) [kg] 110 [50] 115 [52] 115 [52] 120 [54] 140 [63] C21B (2) 20 x 16 [508 x 406] Gas Heat Exchanger Limited Warranty...Twenty (20) Years *Any Other Part...Five (5) Years *This five year limited warranty is applicable only to single-phase products installed in residential applications on or after January 1, 2001. MODEL IDENTIFICATION UPF MODELS U G P L 07E Ruud Gas Upflow/ Design Heating Input Designation Furnace Horizontal Series Electric NOx Input Ignition Model BTU/HR 05E 07E 10E 12E 05N 07N 10N 12N 50,000 [15 kw] 75,000 [22 kw] 100,000 [29 kw] 125,000 [37 kw] B R K R Variations Blower Heating & Cooling Fuel Type A = Std. Designation Designation R = Natural Gas, Cabinet B = Wide Cabinet M = 11 x 7 [279 x 178 mm] R = [279 x 254 mm] K = 600-1200 CFM [283-566 L/s] M = 1200-2000 CFM [566-944 L/s] Q = 1000-1600 CFM [566-944 L/s] U.S. and Canadian Standard Furnace Ruud Air Conditioning Division 3

UPF DIMENSIONS UPF DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] REDUCED CLEARANCES (IN.) [mm] MODEL A B C D E UGPL- LEFT RIGHT SHIP. WGTS. BACK TOP FRONT VENT SIDE SIDE (LBS.) [Kg] 05 17 1 /2 [445] 16 11 /32 [415] 12 1 /8 [308] ➀ 15 1 /2 [381] 0 3 [76] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 105 [47.6] 07, 10 21 1 /2 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 18 1 /2 [470] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 120 [54.4] 12 24 1 /2 [622] 23 11 /32 [593] 15 5 /8 [397] ➀ 22 1 /2 [559] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 140 [63.5] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. 4 Ruud Air Conditioning Division

HORIZONTAL DIMENSIONS WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS. HORIZONTAL DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] MODEL UGPL- A B C D E REDUCED CLEARANCES (IN.) [mm] 05 17 1 /2 [445] 16 11 /32 [415] 12 1 /8 [308] ➀ 15 [381] 0 3 [76] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 110 [49.9] 07 21 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 18 1 /2 [470] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 115 [52.2] 10 21 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 18 1 /2 [470] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 120 [54.4] 12 24 1 /2 [622] 23 11 /32 [593] 15 5 /8 [397] ➀ 22 [559] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 140 [63.5] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP. WGTS. (LBS.) [Kg] Ruud Air Conditioning Division 5

ACCESSORIES UPF SIDE RETURN FILTER RACK: RXGF-CA BOTTOM MOUNT: RXGF-CB FILTER RACK FILTER SIZES INCHES [mm] MODEL UGPL- 05, 07, 10, 12 RXGF-CA (SIDE) 15 3 /4 x 25 [400 x 635] Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. ACCESSORY RETURN AIR CABINETS Return Air Cabinets may be installed on either side application except RXGR-C24B (side application must be on side opposite gas and electrical connections). RXPF-F01 and F02 FOSSIL FUEL KIT is for use with Ruud Heat Pumps and Silhouette II Plus 2 LXE warm air furnaces. RXPF-F02 meets TVA requirements. RXGY-F13 ALTITUDE KIT Required for all models with inputs over 50,000 btu/hr for installations at altitudes of 5,000 ft. and above. Kit includes orifices required for furnaces installed at 8,001 ft. and above. OPTION CODE FOR ALTITUDE: US-277 CANADA-For high altitude derate procedure, refer to furnace installation instructions. *HUMIDISTAT FOR ON-DEMAND DEHUMIDIFICATION: 41-25066-01 *Available through PROSTOCK. THE RXGR-C24B MAY ONLY BE INSTALLED ON THE SIDE OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS. RETURN AIR CABINETS A IN. [mm] FILTER SIZE IN. [mm] RXGR-C17B 17 1 /2 [445] (2) 12 x 16 [305 x 406] RXGR-C21B 21 1 /4 [533] (2) 20 x 16 [508 x 406] RXGR-C24B 24 1 /2 [622] (2) 24 x 16 [610 x 406] WARNING: IMPORTANT NOTICE A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS. FURNACE BASE SOLID BOTTOM BASE WIDTH PLATE SIZE KIT NO. PLATE NO. IN. [mm] IN. [mm] 17 1 /2 [445] RXGB-D17 AE-61874-02 15 1 /8 x 23 9 /16 [384 x 598] 21 1 /2 [533] RXGB-D21 AE-61874-03 18 5 /8 x 23 9 /16 [473 x 598] 24 1 /2 [622] RXGB-D24 AE-61874-04 25 5 /8 x 23 9 /16 [651 x 598] 6 Ruud Air Conditioning Division

BER PERFORMANCE DATA UPF/HORIZONTAL MODELS MODEL UGPL- 05 07 07 10 12 BER SIZE (D X W) INCHES [mm] 11 x 7 [279 x 178] Note: See Form Number C22-206 for MultiFlex coil data. ECM MOTOR H.P. [W] 3/4 [559] 1/2 [373] 3/4 [559] 1 [746] 1 [746] BER SPEED CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa].1 [.025].5 [.12] 1000 [472] 800 [378] 600 [283] 1000 [472] 800 [378] 600 [283] 1600 [755] 1400 [661] 1000 [472] 2000 [944] 1600 [755] 1400 [661] 2000 [944] 1600 [755] 1400 [661] Ruud Air Conditioning Division 7

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RUUD AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. PRINTED IN U.S.A. 9-02 DC FORM NO. G22-473 REV. 3 Supersedes Form No. G22-473 Rev. 2