DIRTT PRODUCT OVERVIEW WALL ACCESSORIES BREATHE LIVING WALL. BREATHE_PRODUCT OVERVIEW_VP Jan2012

Similar documents
Handshower, Hose & Handshower Accessories

VICINITY G R EEN W A LL. Installation Guidelines

ArchiModule. Design freedom, Aesthetic perfection.

Multiple Washer Laundry Control System Pneumatic - Wall Mount - 1 Channel - Installation Guide

Installation Guide & Owner s Manual

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

User and Maintenance Manual for the Homeowner and Installation Instructions for the Contractor. ACU-STEAM Humidifier by Thermolec

User and Maintenance Manual for the Homeowner and Installation Instructions for the Contractor ACU-STEAM. Humidifier by Thermolec

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Installation instructions for condenser tumble dryer DOMESTIC. Dear Customer,

easyspiral The world's fastest Spiral plater

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Chilled Ceiling Elements

Bar Shower Mixer with Shower Set and Fast Fixing Kit. Bar Shower Mixer with Shower Set

cosmopolitan systems

APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH

6-SITE SUPER-FLOW SYSTEM Instruction Manual

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Peridoser Kit. Solenoid Kit. English. Instruction Manual Version P1.3 : copyright 2011, all rights reserved, Bluelab Corporation Limited

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

Here s How 1,500 RPM Equals 100% Safety

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3

Mission Critical. Fuel Supply Systems

IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

Installation Instructions

Dishwasher installation guide

americanstandard.com Phone: Fax:

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Heating with log wood

Alfa Laval Touch Control

Capillary Action Subsurface Irrigation

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

Vacuum drying VD VDL series

THE TRANQUILITY 16 COMPACT (TC) SERIES

Please read and digest ALL the instructions before you commence installation.

SIZE ANY PLACE SHAPE VERTICAL PLANTING SYSTEM NEW INNOVATIVE VERTICAL PLANTING SYSTEM. Flexibility Keyhole Fixing Auto Watering Manual Watering

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Model CAC 500M Media Air Cleaner

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Buffer Tank FWSS 1000 V7-RH

SERRES SUCTION BAG SYSTEM MANUAL

N 700 ELECTRIC PASTA COOKERS ZANUSSI RANGE COMPOSITION

Mediclean Complanate Ultra Clean Ventilation

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

Installation Operation Care

Installation Instructions for Washing Machine DOMESTIC. Dear Customer,

SC City Mains Operations Manual SPECIFICATIONS DIMENSION IMPERIAL METRIC

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

GREEN LOO DRY COMPOSTING TOILET MANUAL. for the. GT 120 Family and GT 330

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM

Installation Manual SPA BROADWAY MAXI

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

Corner Fitting. Level Access or Surface Mounted. P P Non Handed P P

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

These instructions must be left with the user.

Dishwashers. 1 electrolux dishwashers. Undercounter, Hood type, Pot and pan, and Rack Conveyor

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL

Engine cooling. What you will learn. Things you need before you start. Materials. Tools. When you have finished this module, you should know:

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

SPECIALIST The Specialist Deluxe Series II

The most compact solution for your kitchen

PD-811 PD-811 propriétaire Owner s manual Manuel du PD D P

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

User and Maintenance Manual for the Homeowner and Installation Instructions for the Contractor. Steam Humidifier by Thermolec

Installation Instructions

POWER SHOWERS Models 4500M 5002M 4500T 5002T

SELF-CONTAINED CRESCENT CUBER

Hoshizaki America, Inc.

Laser Safety Products. Edition 20

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

Cages for Laying Hens. Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence.

USER GUIDE HYGROMASTER

Universal Heater 20,000 B.T.U. - PN: 9PHWH20S. Installation & Mounting Instructions

Installation Instructions

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

Mobilane offices worldwide. Hungary South Africa Hong Kong United States. The Netherlands Belgium United Kingdom Germany

INSTALLATION INSTRUCTIONS

Head oĸce The Netherlands Leersum. Mobilane. GmbH Emmerich. Mobilane East Europe Debrecen (HU) Mobilane. BeLux Gent. Mobilane Africa Johannesburg

Fat-Free Sewers. How to Prevent Fats, Oils, and Greases from Damaging Your Home and the Enviroment

The SKD direct steam injection system uses low pressure steam from an in-house boiler to humidify the air.

Operation Manual for Eco-Logic Pond & Lake Restoration System

Fan System for Drop Ceilings

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Viking Installation Guide

Package Content. Decor Star 1 2. PL-011-GS Rev. A

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

is an infrared - latentstorage - radiator

Patent Pending CO 2 OLrac. Blade Server Cooling

CURTIS/KUBOTA BX-1500, 1800, 2400, 1850, 2350, 25 BX1870, BX2370, BX25D & BX HEATER INSTALLATION (p/n: 9PH20S18)

Transcription:

DIRTT PRODUCT OVERVIEW WALL ACCESSORIES BREATHE LIVING WALL

1 Breathe Living Wall Assembly DIRTT brings its sustainable, modular, fl exible approach to the world of Living Walls with Breathe. This DIRTT system is a way for everyone to introduce living plants into their interiors to take advantage of the beauty, air cleaning attributes and kick of extra oxygen plants provide, all without using up precious real estate. Breathe is designed to allow plant pot modules to cantilever into the patented DIRTT support extrusions. Plants are easily added, moved and removed without disrupting adjacent plants. A straightforward plumbing system is also integrated with Breathe making watering simple. The self-contained pipes and troughs use gravity to send water through the system. Wicks in each pot allow all plant species to absorb what they need. After the last pot, any remaining water is captured standing water is not an issue for the plants or the occupants of the building. Each pot literally contains the plants to limit diseases and allow for easy removal, inspection or reconfi guration. Breathe Living Wall - Patent Pending ALLOW SPACE FROM EACH END of the DIRTT Wall Tile. Slat Wall may be fl ush with top of Tile or spaced as required. HOLES ARE PRE-DRILLED on Slat for fasteners. FASTEN SLAT WALL to DIRTT Wall Tile using Wood Screws as shown. CONFIRM that Wall Tile and Breathe Slat Assembly are level when assembled. DETAIL - BREATHE SLAT WALL ASSEMBLY attached to DIRTT Wall Tile. BASE BUILDING INSTALL: The Slats can also be attached to base building structures. BREATHE TROUGH ASSEMBLY showing 90 Elbow Connector feed with Inline Connectors joining 2 Troughs and a 90 Elbow Connector overfl ow. (Water Flow in Blue) II of VI

2 Plant Pot Assembly 1. INSERT 2 WICKS into bottom of Plant Pot. NOTE Two wicks per pot is recommended. This can vary dependent upon each plant s water requirements. 2. ADD GROWING MEDIUM AND PLANT (supplied by others) to Pot as shown. Place planting blocks under Pot to position Wicks in vertical position. Use registration lines on Pot to position plants toward front of Pot. * Breathe grows best with a professional, general purpose potting medium - not dirt. Use a soil-less horticultural growth medium (COM) designed for your specifi c plants, combined with a biofungicide to prevent root disease. 3. ROTATE POT AND INSERT WICKS into Trough. BEFORE ADDING WATER ensure that Water Troughs are level. III of VI

3 Manual Water Feed Assembled Breathe Living Wall - Watering THREE BREATHE TROUGHS and Breathe Slat Walls mounted to DIRTT Wall System. Detail shows a single Pot and Trough with Plug for Manual Water Feed (top left) and Overfl ow Container at Water Hose Overfl ow (bottom right). Water fl ow during fi lling indicated in blue. ALL BREATHE PLANT POTS can be repositioned horizontally to accommodate plant density. NOTE: Before adding water, ensure that troughs are level. Water Overfl ow Container IV of VI

DIRTT Product Guide 4 Assembled Breathe Living Wall - with Pressurized Watering System COMPLETE BREATHE WALL mounted to DIRTT Wall System set up for connection to a pressurized Watering System. Detail shows Pots, Quick Connector Regulator at Water Hose Feed (top left) and Overflow Container at Water Hose Overflow (bottom right). Water flow during filling indicated in blue. Water Overflow Container Pressurized Watering System Feed from bottom of Wall Optional Gable Ends V of VI

5 Assembled Breathe - Wall Dimensions CEILING WALL AREA MINIMUM DIMENSION EQUAL SPACE SLATS TROUGHS EQUAL SPACE EQUAL SPACE MINIMUM DIMENSION BREATHE TROUGHS AND SLATS mounted to base building wall. FLOOR GAP FROM EDGE OF TILE SLAT MODULE WIDTH GAP FROM EDGE OF TILE SLAT TROUGH SINGLE TROUGH MODULE WIDTH DIRTT WALL TILE TOTAL TILE HEIGHT TOTAL TILE WIDTH BREATHE TROUGHS AND SLATS mounted to Tile on DIRTT Wall System. VI of VI