QA(13) - Series Miniature Circuit Breakers

Similar documents
Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

VAMP 120 & 121. Arc flash detection units. Product picture

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

* Consult factory on conditions for approval acceptability

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Molded Case Circuit Breakers, Bulletin 140G

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Residual Current Devices

Products :: Circuit Protection :: Thermal Circuit Breakers

LORAIN CIP 4890/48120 DC Power System

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

LORAIN CSP DC Power System

Moulded case circuit brakers

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Bulletin 1608N MiniDySC Dynamic Sag Corrector

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Overload relays. General descriptions. Configuration of the front

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

M7100 Pressure Transducer

M15051) INSTRUCTION MANUAL

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

DTA. Motor thermistor relay. Benefits. Description

Welcome to Hager Presentation

ISIS SAFETY SYSTEM Installation guide

Table of Content LT 5165-UL

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Mains Power Filter 970MF10 970MF20. Installation Instructions

Product Specifications 480 VAC, 175A Main Power Distribution Panel

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Operating Manual TR600

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

PROTECT SRB 200EXi-1A

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

ESP TECHNOLOGIES LIMITED

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

Installation Guide for models:

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

1.7. Insulation fault evaluators EDS460/490 EDS461/491

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

M5200 Industrial Pressure Transducer

Ordering Key. Dielectric strength

Product Specifications 480 VAC, 70A Main Power Distribution Panel

DTA04. Motor thermistor relay. Benefits. Description

RE-PR3-E-27 3-Phase Panel Mount 27kW

CPS V Cabinet Power System

Booster Power Supply Manual

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

Engineered Solutions SYSTEMS CUSTOM ENGINEERED TO YOUR SPECIFICATIONS. Fused Coordination Panelboards...ES 2. Fusible Shunt Trip Switch..

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Emotron M10 Shaft Power Monitor. Instruction manual English

Dräger PointGard 2100 Detection of toxic gases and vapours

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

I/A Series 716C 1/16 DIN Temperature Controller

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

MTRA-FSP Level Control Relay. Installation & Operation Manual

Current and Voltage Sensors

Stego accessories for cabinets

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Installation Guide for models:

1.Application. 2.Main Technical Specifications B-10

M5800 Pressure Transducer with Rotatable Display

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

Fusible Shunt. Trip Switch. Operation and Maintenance Manual SOLUTIONS GUIDE

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Moulded Case Circuit breakers

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

PART GENERAL 1.01 SECTION INCLUDES

CII FCAC-150 Series Relay

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

U5700 Submersible Liquid Level Pressure Transducer

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Product Specifications Auto Restart Main Power Distribution Panel

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Transcription:

1 pole 2 pole 3 pole 3 + N Features AC Circuit Breaker Hydraulic-Magnetic technology 100% rating capability, independent of ambient temperature VC 8036 compliant (SANS 556-1) VDE approved, CE certified Ratings 5 to 60 A (subject to certification) Precision tripping characteristics Ultra compact 13 mm wide module Trip indication with mid-trip position Reset immediately after overload product in black shells Suitable to use for electrical isolation Shell designed for easier installation onto busbar Applications AC branch circuit protection (IEC / EN 60947-2) Switch Disconnector (IEC / EN 60947-3) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Auxiliary Switch, Trip Alarm & Combo: Features Auxiliary Switch Auxiliary Switch + Trip Alarm Trip Alarm AC and DC voltages UL 489 listed (Auxiliary Switch: 6 A 250 V AC, 0.5 A 80 V DC) IEC 60947-5-1 approved (Auxiliary Switch: 6 A 240 V AC, 0.5 A 110 V DC; Trip Alarm: 6 A 240 V AC, 0.5 A 110 V DC) Factory fitted Attached to right hand side of Circuit Breaker Compact 6.5 mm width Optional Accessories Handle lock Surface mounting clips Busbar Escutcheon blank Safety blank Page 1 of 6

Technical Data low voltage Product Type Circuit Breaker Approvals VC 8036 (SANS 556-1) Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 5 A 5 A Maximum Current Rating 60 A 50 A Interrupting Capacity 2.5 ka Product Type Circuit Breaker Approvals IEC / EN 60947-2, VDE Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 5 A Maximum Current Rating 50 A Interrupting Capacity 3 ka Product Type Switch Disconnector Approvals SANS 60947-3 Number of Poles 1 2 3 4 Operating Voltages 240 V AC 415 V AC Current Rating 63 A Description Operating Temperature Range -40 o C to +85 o C Mounting Options Mini Rail, surface mount Time Delay Curves 3 Breaker QA Wire Size mm² (IEC) Torque (IEC) Comments 1 Pole to 4 Pole 0.75-35 mm² 2.5 Nm Pozidriv #2 Combi head Page 2 of 6

Long Code Example Code: QA-----3(13)-MR-3-15A------ Group 1 2 3 4 5 6 7 8 9 10 11 Requirement QA Frame Switch / Neutral 13 mm Auxiliary + Trip Alarm Triple pole module width Mini Rail Short delay curve 3 Current Rating 15 A Future use Shunt Trip Future use Long Code QA - - 3 (13) MR 3 15A - - - Group 1: Frame Type Group 2: Switch/Neutral Group 3: Auxiliary Group 4: No of Poles Group 5: Module Width Group 6: Mounting QA 13 mm wide Miniature Circuit Breaker - Not applicable Overload poles do not have any further coding S Switch Green handle N Neutral - Not applicable Use this code if no Auxiliary used A Auxiliary Switch (1 x Aux in 1 module) 6.5 mm module fitted on right-hand side T Trip Alarm (1 x Trip Alarm in 1 module) 6.5 mm module fitted on right-hand side AT Auxiliary Switch + Trip Alarm combo (combined in 1 module) 6.5 mm module fitted on right-hand side 1 Single pole 2 Double pole 2 pole or 1+N 3 Triple pole 4 Four pole 4 pole or 3+N (13) 13 mm module width MR supplied in black body only - 57 mm Escutcheon DM Dual Mount Dual Mount supplied in black body only - 57 mm Escutcheon Group 7: Code Description Instantaneous Trip Point (x In) Comments Time Delays 3 Short time delay 3 5 White handle Group 8: Code / Description Comments Current Ratings available vary depending on certification Ratings 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 60 A * Other ratings are available as special orders. Check availability. Group 9: Code For future use (-) Group 10: Shunt Trip - Not applicable Use this code if no Shunt Trip is used Group 11 Code For future use (-) For options not listed, please contact CBI for assistance Page 3 of 6

Time Delay Curves 100000 1500 OPERATING CHARACTERISTICS 10000 CURVE 3 1000 Tripping Time (Seconds) 100 10 1 0.1 0.01 Maximum Minimum 0.001 100 105 130 150 200 300 400 500 1000 1500 2000 2500 3000 4000 5000 % Rated Current * The published time delay curves are generated at 30 o C ambient temperature with the Circuit Breaker mounted in the up-right position. The must hold, must trip and instantaneous trip current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Internal Impedance vs Current Rating 10,000 Q-Range impedance values 1,000 Impedance (m Ω) 100 10 Maximum 1 Minimum Page 4 of 6 0.1 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Amp rating

92.8 [3.654] 57.0 [2.244] 11 S 18 15 Typical outline of Auxiliary Switch / Trip Alarm Auxiliary available (6.5 mm module width) to match the unit to which it is attached. Available types as listed in Group 3: Type T - Trip Alarm as shown in outline drawings (fitted on a Dual Mount product) Type AT - Auxiliary Switch + Trip Alarm (as shown) Type A - Auxiliary Switch 69.8 [2.748] 19.3 ± 0.3 [0.760 ± 0.012] AUXILIARY/ TRIP ALARM (AT) 18.0 [0.709] 36.5 [1.436] Circuit diagram when the Circuit Breaker is in the OFF position 6.0 [0.236] Trip Alarm Switch 16 18 NC NO 15 C Auxiliary Switch TEST BUTTON (on Trip Alarm only) RoHS D V E Q-AUX A005438 TRIP ALARM SWITCH AUXILIARY SWITCH 110 VDC : 0,5A 110 VDC : 0,5A 240 VAC : 6A 240 VAC : 6A EN/IEC 60947-5-1 16 Uimp = 2.5kV 12 Icw = 0.1kA UTIL. CAT. AC12/DC12 14 POLLUTION DEGREE 3 11 C 12 14 NC NO 6.5 [0.256] 2.80 [0.110] [ 1.4 0.055] 11.7 [0.461] 0.8 [0.0315] 18.0 [0.709] 37.7 [1.483] 6.8 [0.270] 2.3 [0.090] 0.5 x 45 [0.020] CONNECTING TERMINALS DETAIL (COMMON TO ALL) Typical outline for an Auxiliary module attached to a Dual mount single pole Circuit Breaker All dimensions in mm [ inch ] Tolerance ± 0.4 unless otherwise specified Page 5 of 6

Outline Dimensions: Mini Rail 61.0 [2.402] 19.6 [0.772] 45.0 [1.772] 12.8 ± 0.2 [0.504 ± 0.008] 25.6 ± 0.4 [1.008 ± 0.016] 38.4 ± 0.6 [1.512 ± 0.024] 51.2 ± 0.8 [2.016 ± 0.031] 92.8 [3.654] 57.0 [2.244] 19.6 [0.772] 45.0 [1.772] 64.8 [2.551] 74.0 [2.913] (nominal) 12.8 [0.504] (nominal) All dimensions in mm [ inch ] Tolerance ± 0.4 unless otherwise specified Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 90 Fairbank Road Clayton South Melbourne Victoria 3169 Australia Tel: +61 3 9590 3500 Fax: +61 3 9551 1051 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au SOUTH AFRICA CBI-electric: low voltage Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com Page 6 of 6 A member of the Group