For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

Similar documents
For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

For the compliance with the resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

TYPE APPROVAL CERTIFICATE

Commandant United States Coast Guard

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

TYPE APPROVAL CERTIFICATE

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

TYPE APPROVAL CERTIFICATE

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

Issued to DISTRIBUIDORA INTERNACIONAL CARMEN, S.A -DICSA- Zaragoza Zaragoza, Spain

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

Shipboard incinerators with capacities up to 4000 kw

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

Commandant United States Coast Guard

DNVGL-CP-0398 Edition December 2015

DNVGL-CP-0407 Edition February 2016

TYPE APPROVAL CERTIFICATE

BWTS Installation DNV GL Experience

TYPE APPROVAL CERTIFICATE

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

TYPE APPROVAL CERTIFICATE

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

TYPE APPROVAL CERTIFICATE

Glass fibre rovings - Non-metallic materials

Coatings for protection of FRP structures with heavy rain erosion loads

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

Notified Body No.: 0575

Notified Body No.: 0575

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

GROUNDING AVOIDANCE SYSTEM (GAS)

HYUNDAI HEAVY INDUSTRIES CO., LTD.

DNVGL-CP-0401 Edition February 2016

SOUND RECEPTION SYSTEM

DNVGL-CP-0399 Edition March 2016

Terminal lugs for LV power cables with aluminum conductors

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

DNVGL-CP-0402 Edition February 2016

Notified Body No.: 0575 G U A D N L. SJq

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

EC TYPE EXAMINATION (MODULE B) CERTIFICATE (EC-US MRA)

Notified Body No.: 0098

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

BWTS installation and beyond UK Chamber of Shipping BWM implementation forum

Low Location Lighting

WÄRTS1LÄ. EC-Declaration of Conformitv. In accordance with the Marine Equipment Directive 2014/90/EU

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No

EC Type Examination Certificate

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Survey of electrical equipment installed in hazardous areas on tankers

GLASS FIBRE REINFORCEMENTS

PQS Independent type-testing protocol

INFORMATION BULLETIN No. 150

DIRECTIVE NO: D-B

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

PQS Independent type-testing protocol

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Michigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Automation, safety and telecommunication systems

Enraf Servo Gauge 854 ATG

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

FAHM Co. Temperature Transmitter PTT74 Series

MED 96/98/EC QUALITY SYSTEM MODULE D CERTIFICATE

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Presentation to the Ballast Water Collaborative Duluth, Minnesota August 2 & 3, Prepared by:

LAB DIVISION. WASHING & DRYING cglp Process Equipment for Research and Microbiological Laboratories

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

Training, Assessment, Consultants for Hazardous & Industrial Areas

INTERNATIONAL STANDARD

Enraf Servo Gauge 854 XTG

Marine Solutions. Honeywell s Solution for LNG Vessels

FDOOT241-A9-Ex Multisensor fire detector

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

4590 Tank Side Monitor. Service Manual. WM550 Communication Protocol. Software Versionv2.03 SRM011FVAE0808

City of Duluth Festival Center 04/25

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Technical Manual. Level Alarm Unit CARLA & WIDS

OOH740-A9-Ex Multisensor fire detector

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

Topic MYTH FUNCTIONAL SAFETY IMPLIES HAVING A SIL RATED COMPONENT. Presented by : Arunkumar A

Protective & Marine Coatings Europe, Middle East, Africa & India

EC TYPE EXAMINATION CERTIFICATE

Declaration of conformity

CERTIFICATE OF FIRE APPROVAL

Apr06 Rev A

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment

Transcription:

Certificate No: TAP000006X Revision No: 1 This is to certify: That the Ballast Water Management System with type designation(s) Optimarin Ballast System, Optimarin Ballast System Ex Issued to Optimarin AS SANDNES, Norway is found to comply with Resolution MEPC.174(58) DNV GL class programme DNVGL-CP-0209 Type approval Ballast water management systems DNV GL rules for classification Ships Application : This is to certify that the Ballast Water Management System listed above has been examined and tested in accordance with the requirements of the specifications contained in Guidelines contained in Resolution MEPC.174(58) and DNV GL Rules stated above. This Certificate is valid only for the Ballast Water Management System referred to above. For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority. Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL, unless otherwise instructed by the relevant Maritime Administration. Type: Optimarin Ballast System Optimarin Ballast System Ex Issued at Høvik on 2018-03-08 This Certificate is valid until 2019-12-08. DNV GL local station: Stavanger Approval Engineer: Liliana Castro for DNV GL Dag Sæle-Nilsen Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 1 of 9 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Ballast water management system supplier Optimarin AS Type and model designation Optimarin Ballast System (OBS), Optimarin Ballast System Ex (OBS Ex) Place of production: Sandnes, Norway Equipment / Assembly drawings Ballast Water Management System (BWMS) shall be installed in accordance with the relevant piping and instrumentation diagrams and relevant wiring diagram listed below. Description Title Drawing No. Rev. Piping and instrumentation diagram Flow Diagram 300000 Rev. 02 dated Piping and instrumentation diagram Flow Diagram with stripping 300000 Rev. 02 dated Piping and instrumentation diagram Flow Diagram EX 300000 Rev. 02 dated Wiring diagram Wiring diagram Control Panel, Filter Control Incl BFP01, Sensor Box 1, UV Power Cabinet Type NED, Terminal Box, Control Panel, Filter Control Incl BFP01, Sensor Box 1, Terminal Box, UV Power Cabinet Type ETA 500000 Rev. 03 dated 500000 Rev. 03 dated Product description The Operation, maintenance and safety Manual for Optimarin Ballast System, Rev 4, Template dated 2/20/2018. This manual is specific to BK (IMO, USCG) or FX (IMO) or FS (IMO) filters, approved by DNV GL. Treatment sequence Ballast water uptake: Filtration/UV disinfection Ballast water discharge: UV disinfection Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 2 of 9

OBS is approved with three alternative filters; FilterSafe Automatic Back-flush filter BSFc-H-16 (Micro-Kill BSF Filter) with 40μm mesh Filtrex Automatic Filter ACB-935-200 with 40μm mesh Boll & Kirch Automatic Selfclean Filter type 6.18, 6.18.2 or 6.18.3 BWT with 40μm mesh Application/Limitation Temperature and salinity Temperature is no limiting condition. The system has not been tested in fresh water. UV intensity UV intensity below 100 W/m 2 implies that the ballast water is not treated in accordance with this certificate. Treatment Rated Capacity (TRC) of UV Operational range of one UV-chamber is 20 m 3 /h 167 m 3 /h. A combination of UV-chambers is accepted under the following criteria: Chambers mounted in parallel (vertically or horizontally) The construction of the chambers (i.e. dimensions, form and material) is exactly the same The construction of the two manifolds (i.e. dimensions, form and material) is exactly the same Any other construction that does not fit to the above must be approved by DNV GL before allowed to be considered as part of this Type Approval Certificate. Treatment Rated Capacity (TRC) of Filters Filter Type Filter Safe (FS) Based on statement and documentation received from FilterSafe, all filters capacities listed below are covered by this Type Approval: Model Flow Rate (m 3 /h) Minimum back-pressure Single Min *Max BS-025H/V 10 50 1.7 bar 0.5 bar BS-050H/V 30 125 1.7 bar 0.5 bar BS-070H/V 30 180 1.7 bar 0.5 bar BS-100H/V 40 250 1.7 bar 0.5 bar BS-150H/V 50 375 1.7 bar 0.5 bar BS-200H/V 60 500 1.7 bar 0.5 bar BS-300H/V 60 750 1.7 bar 0.5 bar BS-400H/V 80 1000 1.7 bar 0.5 bar BS-603H/V 150 1500 1.7 bar 0.5 bar BS-804H/V 180 2000 1.7 bar 0.5 bar BS-1004H/V 180 2500 1.7 bar 0.5 bar BS-1204H/V 200 3000 1.7 bar 0.5 bar BS-1206H/V 250 3000 1.7 bar 0.5 bar *With 40μm screen and according to IMO G8 Guidelines Max. pressure drop allowed Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 3 of 9

Differential pressure for back-flush to be initiated at 0.5 bar. Filter Type Filtrex (FX) Based on statement and documentation received from Filtrex ACB Scaling and Guiding Principles of Ballast Water Filters, all filter capacities listed below are covered by this Type Approval: Model Flow range (m 3 /h) Minimum back-pressure ACB-903-65 8 35 1.5 bar 0.5 bar ACB-904-80 10 55 1.5 bar 0.5 bar ACB-906-100 15 87 1.5 bar 0.5 bar ACB-910-150 25 135 1.5 bar 0.5 bar ACB-915-150 35 190 1.5 bar 0.5 bar ACB-935-200 35 255 1.5 bar 0.5 bar ACB-945-200 45 340 1.5 bar 0.5 bar ACB-955-250 50 515 1.5 bar 0.5 bar ACB-985-300 65 770 1.5 bar 0.5 bar ACB-999-350 95 1040 1.5 bar 0.5 bar ACB-9100-400 126 1500 1.5 bar 0.5 bar ACB-9120-500 126 2100 1.5 bar 0.5 bar ACB-9200-600 126 3000 1.5 bar 0.5 bar Differential pressure for back-flush to be initiated at 0.3 bar. Max. pressure drop allowed Boll and Kirch Filter (BK) Based on DNV GL report No. 38FIST1303515 2 and statement and documentation received from Boll & Kirch Table from Bollfilter dated 25-10-2016 and Cross Sectional Drawings & Candle Placement, all filter capacities listed below are covered by this Type Approval: Model Flow range (m 3 /h) Minimum back-pressure MK1 6.18 14 40 2 or 1.5 bar with suction MK1 6.18 24 100 2 or 1.5 bar with suction MK1 6.18.2 74 220 2 or 1.5 bar with suction MK1 6.18.2 110 400 2 or 1.5 bar with suction MK1 6.18.2 124 600 2 or 1.5 bar with suction MK1 6.18.2 150 800 2 or 1.5 bar with suction MK1 6.18.2 182 1200 2 or 1.5 bar with suction MK1 6.18.2 204 1600 2 or 1.5 bar with suction MK1 6.18.2 271 2500 2 or 1.5 bar with suction Max. pressure drop allowed MK1 6.18.2 446 3300 2 or 1.5 bar with suction Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 4 of 9

MK1 6.18.2 558 4300 2 or 1.5 bar with suction MK1 6.18.2 581 5400 2 or 1.5 bar with suction MK2 6.18.3 83-370 1.5 bar MK2 6.18.3 85-500 1.5 bar MK2 6.18.3 85-750 1.5 bar MK2 6.18.3 168-1400 1.5 bar MK2 6.18.3 205-2100 1.5 bar MK2 6.18.3 214-2500 1.5 bar MK2 6.18.3 326-3800 1.5 bar Differential pressure for back-flush to be initiated at 0.38 bar. Operational specifications for the different components UV-intensity meter Acceptable range: 100 2500 W/m 2 The system includes UV-lamp power control. UV-lamp power is reduced in favorable water conditions based on measured UV-intensity. The control equipment has power regulation and has been designed and tested to keep the measured UV intensity above 800 W/m 2. Control and monitoring equipment The type approved system includes a UV-intensity meter, a temperature sensor, pressure sensor, flow meter and a flow pressure valve. The control equipment has been designed and tested to keep the flow rate between 20 m 3 /h 167 m 3 /h per UV-chamber. Acceptable range for the UV-intensity meter is 100 2500 W/m 2. The system also includes a temperature switch in the UV chamber, arranged with an independent shutdown functionality. Information regarding the selected components shall be part of the documentation related to the specific installation, either by a reference to valid Type approval certificate or technical documentation. The type approved system includes the following control units and sensors: Name Model Software revision Control Panel CP NA Filter Control FC NA Sensor Box SBx NA Terminal Box TBxx NA Back Flush Cabinet BFC NA Fresh Water Panel FWP NA Interlock Panel IP NA UV Power Type TT Desiteck GmbH, UVPxx TT NA UV Power Type NED Nedap N.V., UVPxx NED A UV Power Cabinet Type ETA UVPC PE35B NA UV sensor IL-Metronic, SUV 20.2.Y2C NA OBS control software OBS PLC/OP 1.5x Ex Interlock Panel EXIP NA Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 5 of 9

Ex Sensor Box EXSBx NA El. Act. Power Distribution Panel EAPDP NA All changes in software are to be recorded as long as the system is in use onboard. The records of all changes are to be forwarded to DNV GL for evaluation and approval. Major changes to the software are to be approved before installed in the computer. A Certification of Application Functions may be required for the particular vessel. Explosion proof version OBS Ex The model OBS Ex is prepared for installation in zone 1 hazardous areas. In case of location in the room of a tanker, the tanker must have zone classification of the room acc to DNV GL rules from July 2006 and later. The ex certification of the system has been reviewed and found acceptable as part of the Type Approval. Ref. DNV GL Rules Pt.4 Ch 8 Sec.11. Documentation related to Ex certification is to be delivered to yard/owner. It is to be submitted for approval and subsequent survey for each ship acc. to normal procedures: Schedule of ex certificates Ex certificates Loop calculation of intrinsically safe circuits The Ex certified components are listed in the manufacturers document: Bill of Materials BOM EX installation Rev 1. Documents approval The following documentation is to be submitted for approval in each case: Piping and Instrumentation Diagram (P&ID) of the ballast system including the treatment system installation Wiring diagram An overview of all controlled and monitored points, (I/O list) Description confirming the arrangement of alarms for bypass of the BWMS List of ex equipment according to DNVGL Pt.4 Ch.8 Sec.11, 2.1.1 and if the system is to be installed in hazardous zone. Procedures for approval of OBS Ex is further described in the section above. Type Approval documentation Land-based testing of the Optimarin ballast water management system of Optimarin AS Final Report, Report SNO 5643-2008 approved by DNV on 2009-11-05. Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 6 of 9

Shipboard testing of the Optimarin Ballast System of Optimarin AS, Report SNO 5828-2009 approved by DNV on 2009-10-21. Additional land-based testing of the Optimarin BWMS with alternate filter, Report L.NR. 5840-2009 approved by DNV on 2009-11-12. Additional land-based testing of the Optimarin BWMS with alternate filter, Report SNO 6284-2012 approved by DNV on 2012-05-04. EMC and Environmental testing of Optimarin Ballast Water Control System, Report No. 2009-3397 approved by DNV on 2009-11-11. EMC test report of the UV Power Cabinet, Report No. 9505 330 462XX 002, rev. 3 approved by DNV on 2012-08-23. Mechanical and Climate test report of the UV Power Cabinet, Report No. 9505 330 462XX 001 approved by DNV on 2012-08-23. QAPP for shipboard testing approved by DNV on 2009-04-27. QAPP for land-based testing approved by DNV on 2008-02-01. QAPP for full scale testing of the Optimarin BWMS tests of alternate filters approved by DNV on 2009-10-01. QAPP for full scale testing of the Optimarin BWMS tests of alternate filter approved by DNV on 2012-05-03. Pre-test evaluation documentation approved by DNV on 2007-12-06. Survey report of the land-based tests, dated 2008-03-12. Survey report of the shipboard tests, dated 2009-04-08. Survey report of the land-based tests with alternate filter, dated 2009-10-01. Survey report of the function testing of the control and automation system, dated 2009-10-19. Survey report for verification and testing of Flow Pressure Valve, dated 2009-10-21. Type Approval Initial survey report of OptiMarin AS, dated 2009-10-27. Survey report for verification and testing of the automatic control of UV intensity, dated 2010-09-02. Survey report for verification and testing of addition of Back Flush Cabinet, Fresh Water Panel and Interlock Panel, dated 13-12-09. EMC and Environmental testing of Gönnheimer Elektronic GmbH Control unit F850S and power supply for Optimarin AS, Report 20226, Rev. 1. DNV GL Type Approval Certificate A-14198 issued to Eta plus electronic gmbh for UV Power Cabinet Type Eta. Filtrex ACB Scaling and Guiding Principles of Ballast Water Filters, St. 73, Rev 6, Report dated Nov. 2016 Filter 1500M3H DN400 PN10 Type FX, Drawing No 145839, Rev 1 Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 7 of 9

Filter 2100M3H DN500 PN10 Type FX, Drawing No 146517, Rev 1 Filter 3000M3H DN600 PN10 Type FX, Drawing No 146518, Rev 1 Class survey checklist for Optimarin Ballast System, Rev 1, Template dated 2/20/2018 Class survey checklist for Optimarin Ballast System Ex version, Rev 1, Template dated 2/20/2018 Bill of Material 1, Ex certified components rev.1. Approval date 11.12.2017 Operation, maintenance and safety Manual for Optimarin Ballast System, Rev 4, Template dated 2/20/2018. This manual is specific to BK (IMO, USCG) or FX (IMO) or FS (IMO) filters Operation, maintenance and safety Manual for Optimarin Ballast system Ex Version, Rev 4, Template dated 2/20/2018 Applica Technical Report Optimarin AS Environmental testing of Temperatures Switches, Report No. 21250 Rev 1 UV chamber with instrumentation, Illustration for DNVGL dual safety layer requirement, Drawing No. 100000, Rev - Tests carried out Land-based testing in accordance with Resolution MEPC.174 (58) witnessed by DNV GL Shipboard testing in accordance with Resolution MEPC.174 (58) witnessed by DNV GL Land-based testing for alternate filter witnessed by DNV GL Factory Acceptance Test of the control and automation system witnessed by DNV GL Environmental testing in accordance with Environmental test specification for instrumentation and automation equipment, DNV GL CG-0339 and Resolution.174(58) Marking of the product For the traceability of this Type Approval, each treatment system is to be marked with: Manufacturer s name or trade mark Type designation Serial number Periodical assessment For retention of the Type Approval, DNV GL Surveyor shall perform a Periodical Assessment to verify that the conditions of the TA are not altered since the certificate was issued. The scope of periodical assessment includes: Review of the TA documentation and verification that the documentation is still used as basis for the production. Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 8 of 9

Review of possible changes in design, material and performance of the product. Verification of the companys production and quality systems ensuring continued consistent production of the type approved products to the required quality. Verification that the product marking for identification and traceability to the TA Certificate is not altered. Copy of type approval certificate A copy of this Type Approval Certificate should be carried on board a vessel fitted with this ballast water management systems at all times. A reference to the test protocol and a copy of the test results should be available for inspection onboard the vessel. END OF CERTIFICATE Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 9 of 9