Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Similar documents
USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Indoor/Outdoor Temperature Alert

USER MANUAL Digital CO Monitor Model CO30

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

User's Guide. Pinless Moisture Meter. Model MO257

USER GUIDE Heat Index Psychrometer

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USER MANUAL USB Multi-Function Datalogger Model RHT35

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

User's Guide. Pinless Moisture Meter. Model MO257

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Wet Bulb Thermo-Hygrometer Datalogger

4-in-1 Humidity, Temperature Airflow and Light Meter

User's Guide. CO 2 Monitor. Model CO200

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

Dual Laser InfraRed (IR) Thermometer

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

E1000 Portable gas detector

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dual Laser InfraRed (IR) Thermometer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

PCD110X - Premium Choice with DC Motor (Ceiling Mounted Ventilation Fans)

Portable type of Carbon Dioxide Detector Model: GT220

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

IMR EX610. Portable Gas Detector. Operation Manual

NGD8800 USER S MANUAL

Combustible Gas Leak Detector Instruction Manual

High Temperature InfraRed Thermometer with Laser Pointer

Installation and Wiring 1.

MicroRay IR-100 NEW. Inspection MicroRay IR-100

IMR IX176 Portable Gas Detector User Manual

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

SP-220. Features. Combustible handheld gas leakage detector

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

SAFESITE Multi-Threat Detection System

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Combustible Gas Leak Detector Instruction Manual

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

GasAlertMicroClip X3 Specifications

Agilent Electronic Crimping and Decapping Tools Operating Guide. Agilent Technologies

Manual Electrical Fire Alarm System

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

TM-802 Formaldehyde Meter User s Manual

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Introduction. OM-THA2

ALTAIR 5X Multigas Detector Product Specification

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

DIGITAL KITCHEN SCALE

Thermohygrometer with Single Type K Input and Superheat Function

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

BestAir. Instruction manual

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Safe Operation Manual. Honeywell IQ Force Gas Detector

Air Purifier Test Report (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

EVac II Programmable Digital Vacuum Gauge

MODEL MR-720 FUNCTIONS AND CONTROLS SELF-POWERED AM/FM WEATHER BAND CLOCK RADIO

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

ESD3000 ESD200 Combustible / Toxic Gas Detector

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

CD100A COMBUSTIBLE GAS DETECTOR

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Bacharach Bodyguard 4 User's Guide

FUNCTION AND CONTROLS

R2310. Infrared Thermometer. Instruction Manual

Digital Cooking Thermometer models / 00282

Sirius MultiGas Detector

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Specifications Minimum Typical Maximum Unit

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

BestAir. Instruction manual

testo 316-EX gas leak detector Instruction manual

EasyLog Data Logger Series

Electronic Crimping Tools Operations Guide. Contents

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

CO warning instruments and gas spillage detectors

Transcription:

User Manual Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester Model VFM200 Additional User Manual Translations available at www.extech.com

Introduction Thank you for selecting the Extech Instruments Model VFM200. The VFM200 measures HCHO (formaldehyde) and TVOC (Total Volatile Organic Compounds). Potential sources for TVOCs include paints, finishes, adhesives, cigarette smoke, pesticides, personal care products, car exhaust, new furnishings, wall coverings, household cleansers, and cooking fuels. Chemicals include: Acetone, Ethylene Glycol, Formaldehyde, Xylene, 1, butadiene, Tetrachloroethene, Hydrogen Sulfide, Ammonia, Toluene, Benzene, Methylene Chloride, Perchloroethylene, and MTBE. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Features Fuel Cell Formaldehyde Sensor Technology High accuracy measurements Backlit LCD display Real time display of HCHO (formaldehyde) concentration in air Real time display of TVOC (Total Volatile Organic Compounds) concentration in air Two unit selections (PPM, mg/m³) Audio visual High and Low Alarms for HCHO Auto power off Description METER DESCRIPTION 1. HCHO sensor (front) 2. AC Adaptor jack (under flap). Down arrow and Alarm Setup button 4. Battery compartment (rear) 5. ON OFF button (also used in Alarm Setup) 6. Up arrow and UNIT selection button 7. Backlit Display 8. TVOC sensor (rear) 1 2 4 8 7 6 5 2 VFM200 en GB_V1.2 12/16

LCD DISPLAY 1. HCHO reading 2. TVOC reading. Selectable units of measure 4. Alarm Beeper symbol 5. Auto Power OFF reminder 6. Rechargeable Battery status 7. High and Low Alarm symbols Operation POWER THE METER Press the button to turn on the meter. The battery symbol informs the user as to the battery strength. Connect the battery charger to recharge the battery. Long press the button to power off. The LCD will count down:, 2, 1, then OFF before switching off. AUTO POWER OFF The meter will switch off after 0 minutes of inactivity. Press any function button to prevent the meter from powering off; the auto power off timer will be then be reset. The APO display symbol reminds the user that Auto Power OFF is always active. GERNERAL USE All LCD display lines will switch ON when power is applied to the meter. The bottom TVOC display will count down from 10 seconds or from 90 seconds (depending on the environment) to zero. When countdown is complete the meter is ready for use. In normal mode, the top display indicates the HCHO concentration in PPM or mg/m³. The bottom display indicates the TVOC concentration in PPM or mg/m³. Use the UNIT button to switch units between PPM and mg/m³. With the meter on, if the measured HCHO concentration exceeds the high or low userprogrammable Alarm thresholds, the LED display will flash red in color and the audible beeper will sound (unless it has been disabled with the SET/ button). Press SET/ to silence the alarm beeper (when it is sounding) or to disable the beeper entirely. When disabled, the displayed beeper symbol is switched off. ALARM SETUP (HCHO only) Low Alarm Setup 1. Long press the SET/ button to enter the setup mode. 2. The low alarm icon will display and the LCD will show the low alarm threshold.. Use the and buttons to adjust the low alarm threshold. 4. Press the button to go to the high alarm setup screen. High Alarm Setup 1. Use the and buttons to adjust the high alarm threshold. 2. Press the button to return to the normal measurement mode. 1 2 7 mg/m mg/m 6 5 4 VFM200 en GB_V1.2 12/16

CONTROL BUTTONS 1. Short press the SET button to silence the beeper (when it is sounding) or to disable/enable the alarm beeper. This button is also used as a down arrow to change the high and low Alarm threshold values in the Alarm Setup mode. 2. Long press the SET button to enter the Alarm Setup Mode (See Alarm Setup section).. Short press the UNIT button to change the unit of measure (PPM or mg/m³) or to use it as an up arrow to set the alarm threshold values in the Alarm Setup mode. SAFETY Do not store or use the instrument in an environment where corrosive gas is present. Do not obstruct the sensors when in use. Use only the supplied lithium ion battery to power the meter. Use only the supplied AC adapter/battery charger to charge the lithium ion battery. BATTERY CHARGE and REPLACEMENT 1. When the battery requires charging, plug the supplied battery charger into the meter (left side, under flap) and to a source of AC power. A full charge requires 2 hours. 2. To replace the battery, open the rear battery compartment and replace the Polymer lithium ion battery (7.4V 100mAh). Re assemble the meter before use (part# VPC BATT) Battery Safety Notes: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the battery and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end oflife devices to a designated collection point for the disposal of electrical and electronic equipment. CLEANING AND STORAGE Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solve nts. Please remove the battery if the meter is stored for a long period of time. 4 VFM200 en GB_V1.2 12/16

Specifications Sensor HCHO Range HCHO Resolution HCHO Basic Accuracy TVOC Range TVOC Resolution TVOC Basic Accuracy Response Time Operating Temperature Storage Temperature Power Supply Battery Charge Time Battery Dimensions Weight Professional Fuel Cell technology 0.00 to 5.00 mg/m³ (or PPM) 0.01 mg/m (or PPM) ±5% FS 0.00 to 9.99 mg/m³ (or PPM) 0.01 mg/m³ (or PPM) ±5% FS 2 seconds 0 C to 40 C (2 to 104 F) 10 C to 60 C (14 to 140 F) Rechargeable Polymer lithium ion battery (7.4V 100mAh) Approx. hours with AC adapter 7.4V 100mAh (part # VPC BATT) 165 x 60 x 25mm (6.5 x 2.4 x 1.0 in.) 584g (20.6 oz.) Copyright 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 5 VFM200 en GB_V1.2 12/16