CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Similar documents
B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

MERIT SERIES Up Flow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

C22 Bulletin # October 1993 Supersedes May 1993

C22FC Bulletin # October 1993 Supersedes May 1993

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

CB X 32 mv

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Visit us at For the latest technical information,

T P A 120 S 4 S N 1 Y

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

T S A 048 S 4 N 4 1 T

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

13 GEP A L P - 1 A

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

CHA to 17.6 kw (2 to 5 Ton) Bulletin # October 1994 Supersedes October 1990 ENGINEERING DATA. CHA16 Basic Unit. CHA16H-261 Basic Unit

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

8+* Bulletin No November 1997

RGE 13 A T - 1 A

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

2 shp 13 lc 1 36 t - 1 a

CWA4 Chilled & Hot Water Fan Coil

G34M Bulletin #69/ August 2003

50TM COMBINATION HEATING/COOLING UNITS

SKYPAK II, 3 Ton Series, gives you a

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS

GSR21Q PULSE21 SERIES

T P A 048 S 4 N 4 1 T

50TM TFF COMBINATION HEATING/COOLING UNITS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Product Specifications. Vertical Floor Consoles By First Co.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

14 AC x

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Performance and Reliability. CB*, C* and TA* Models

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

SECTION FAN COIL UNITS

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Vertical Upflow Horizontal Left Air Handlers

SECTION CONVECTION HEATING AND COOLING UNITS

NEW CUTAWAY POSITION ONLY

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

MERIT SERIES Downflow

Advance Release September 2009

PACKAGE AIR CONDITIONER

Commercial High-Efficiency Condensing Units

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

FCC Fan-Coil Units High-Performance, Vertical

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

TECHNICAL SPECIFICATIONS B6VMMX

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

HIGH EFFICIENCY AIR HANDLER

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Cooling/Heat Pump Convertible Air Handlers

Commercial High-Efficiency Condensing Units

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

48TM GAS HEATING/ELECTRIC COOLING UNITS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Cooling/Heat Pump Convertible Air Handlers

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Modular Multi-position Air Handler

SKYPAK II Heating & Cooling Self Contained Packages

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

CBX32MV (HFC-410A) SERIES UNITS

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

RE9X Series Downflow, Upflow Electric Furnaces

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

E3EH-xxx-H Series E3EB-xxx-H Series

Transcription:

ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED BLOWER REMOTE COIL SYSTEMS UNITS 50hz CB18/CBS18 Bulletin #490019 September 1994 Supersedes August 1986 CBS18 Horizontal CB18 Up-Flow Compact Blower-Coil Units Feature Efficient Operation and Application Flexibility The CB18 and CBS18 series blower-coil units are designed to meet reduced space requirements in a variety of applications. Highly efficient units provide the answer to many difficult installation problems. The flexibility of the units permit simple installations in a furred-in space, attic, crawl space, drop ceiling or closet. Versatile units are available in up-flo or horizontal models. Optional field installed electric heaters are available in several sizes for heatingcooling applications. For cooling capacities see condensing unit bulletins indexed in section Cooling Units Split System Condensing Units. Heavy gauge galvanized steel cabinet is completely insulated. Flare fittings provide quick and easy connection of refrigerant lines. Large indoor coil is sized for maximum cooling efficiency. Direct drive blower has multi-speed motor providing a choice of blower speeds. In addition, units have been tested with matching condensing units in the Lennox Research Laboratory environmental test room which meet American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Standard 37 requirements. The rating test conditions are those included in Air-Conditioning and Refrigeration Institute (ARI) Standard test conditions while operating at rated voltage and air volumes. Blower performance data is according to actual unit tests conducted in Lennox air test chamber. Blower-coil units and components within are bonded for grounding to meet safety standards for servicing required by Underwriter s Laboratories (U.L.) and the International Electrotechnical Commission (I.E.C.). Units are shipped factory assembled. Each unit is tested at the factory to ensure proper operation at system start-up. NOTE Due to Lennox ongoing committent to quality, Specifications, Ratings and Dimensions subject to change without notice. 1994 Lennox Industries Inc.

FEATURES Durable Cabinet Constructed of heavy gauge galvanized steel and completely insulated with thick fiberglass insulation. The cabinets are subject to a five station metal wash process before painting. This preparation process results in a perfect bonding surface for the attractive finish coat of baked-on enamel. Removable panels provide complete service access. Evaporator Coil Extra large surface area of Lennox designed coil provides maximum cooling efficiency, excellent heat transfer and low air resistance. Precise circuiting gives uniform refrigerant distribution. Lennox fabricated coil is constructed of precisely spaced ripple-edged aluminum fins fitted to durable seamless copper tubes. Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area. Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Long life copper tubing is easy to field service. Coil is thoroughly factory tested under high pressure to insure leakproof construction. CB18 models are equipped with dual coils in an V configuration. CBS18 models have a single slab coil. Drain Pan Deep, corrosion resistant drain pan has dual pipe drains extended outside of cabinet for ease of connection. See dimension drawings. Refrigerant Line Connections Vapor and liquid lines are equipped with flare fittings and extend outside of the cabinet for ease of connection. CB18/CBS18-65 vapor line requires sweat connection. See dimension drawing for location. Transformer and Blower Cooling Relay (Furnished) A 24 volt transformer and blower cooling relay are furnished as standard equipment and are factory installed. A terminal block is also furnished as standard. Direct Drive Blower Equipped with a Lennox designed and built direct drive blower. Each blower is statically and dynamically balanced as an assembly before it is installed in the unit. Multi-speed motor is resiliently mounted. A choice of blower speeds is available. See blower performance charts. Change of blower speeds is easily accomplished by a simple change in wiring. OPTIONAL ACCESSORIES (Must Be Ordered Extra) Electric Heat (Optional) Additive electric heaters field install internal to the unit cabinet and are available in several kw sizes, see Electric Heat table. The helix wound nichrome bare heating elements are exposed directly in the air stream resulting in instant heat transfer, low element temperatures and long service life. Each heating element is equipped with accurately located limit control with fixed temperature off setting and automatic reset. In addition, elements have supplemental thermal cutoff safety fuses providing positive protection in case of excessive temperatures. Cutoff fuses are mounted external to the element face plate for quick and easy replacement. Thermal sequencer relay brings the heating elements on and off line, in sequence and equal increments, with a time delay between each element. Sequencer also initiates and terminates blower operation. Heating control relay(s), is furnished as standard. Control box and access cover are constructed of heavy gauge galvanized steel. Heaters are factory assembled with controls installed and wired and only require plug-in field connection. Expansion Valve Kits (Optional) Kits must be ordered extra and field installed on the blower-coil unit. See condensing unit bulletin for proper kit. Filter Kit (Optional) Kit must be ordered extra and field installed. Filter box installs on return air opening external to the unit cabinet. A throwaway frame type filter is furnished on kits for CB18 up-flo models. Filter kits for CBS18 horizontal models are field assembled. Filter(s) are not furnished on kits for CBS18 horizontal models and must be ordered extra. Filter box has an access panel for removal and replacement of filter. See specification table and dimension drawings for details. SPECIFICATIONS CB18 UP-FLOW MODELS CB18-26 CB18-41 CB18-51 CB18-65 Net face area ft. 2 (m 2 ) 3.55 (0.33) 4.22 (0.39) 4.67 (0.43) 5.25 (0.49) Tube outside diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Evaporator Coil Number of rows 3 3 4 4 Fins per inch (fins per m) 16 (630) 15 (591) 13 (512) 16 (630) Suction line connection in. (mm) flare 5/8 (15.9) 3/4 (19) 3/4 (19) 1-1/8 (28.6) sweat Liquid line connection in. (mm) flare 3/8 (9.5) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) Condensate drain connection (male pipe thread) in. (mm) (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) Nominal cooling capacity tons (kw) 2 (7) 3 (11) 4 (14) 5 (18) Refrigerant HCFC-22 Blower wheel nominal diameter x wifdth in. (mm) 9 x 7 (229 x 178) 9 x 9 (229 x 229) 10 x 9 (254 x 229) 11-1/2 x 9 (292 x 229) Blower motor output hp (W) 1/3 (249) 1/3 (249) 1/2 (373) 1 (746) Electrical characteristics 220/240 volts 50 hertz 1 phase Shipping weight lbs. (kg) 1 package 100 (45) 115 (52) 170 (77) 180 (82) Optional Accessories (Must Be Ordered Extra) Catalog number 66F55 79F60 10G22 Filter Kit Number and size of filters in. (1) 16 x 20 x 1 (1) 16 x 25 x 1 (1) 20 x 25 x 1 mm (1) 406 x 508 x 25 (1) 406 635 x 25 (1) 508 x 635 x 25 Filters are furnished with kit. Shipping weight lbs. (kg) 5 (2) 8 (4) 9 (4) 2

SPECIFICATIONS CBS18 HORIZONTAL MODELS CBS18-26 CBS18-41 CBS18-51 CBS18-65 Net face area ft. 2 (m 2 ) 2.45 (0.23) 3.55 (0.33) 5.45 (0.51) 5.45 (0.51) Tube outside diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Evaporator Number of rows 4 4 3 4 Coil Fins per inch (fins per m) 13 (512) 14 (551) 16 (630) 16 (630) Suction line connection in. (mm) flare 5/8 (15.9) 3/4 (19) 3/4 (19) 1-1/8 (28.6) sweat Liquid line connection in. (mm) flare 3/8 (9.5) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) Condensate drain connection (male pipe thread) in. (mm) (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) Nominal cooling capacity tons (kw) 2 (7) 3 (11) 4 (14) 5 (18) Refrigerant HCFC-22 Blower wheel nominal diameter x wifdth in. (mm) 9 x 7 (229 x 178) 9 x 9 (229 x 229) 10 x 9 (254 x 229) 11-1/2 x 9 (292 x 229) Blower motor output hp (W) 1/3 (249) 1/3 (249) 1/2 (373) 1 (746) Electrical characteristics 220/240 volts 50 hertz 1 phase Shipping weight lbs. (kg) 1 package 105 (48) 130 (59) 185 (84) 210 (95) Optional Accessories (Must Be Ordered Extra) Catalog number 40G85 40G86 40G87 Filter Number and size of in. (1) 20 x 25 x 1 (1) 16 x 20 x 1 (1) 406 x 508 x 25 Kit filters mm (1) 508 x 635 x 25 (1) 406 x 508 x 25 (1) 406 x 508 x 25 Shipping weight lbs. (kg) 25 (11) 23 (10) 35 (16) Filters are not furnished with kit and must be ordered extra. OPTIONAL ELECTRIC HEAT DATA Indoor Coil Unit Electric Heat Unit and Shipping Weight Number of Elements (Steps) Volts Heating Capacity Input (1 phase) Btuh kw 220 7 200 2.1 ECB18-2.5 5 lbs. (2 kg) 1 230 7 800 2.3 240 8 500 2.5 220 14 300 4.2 ECB18-5 5 lbs. (2 kg) 1 230 15 700 4.6 240 17 100 5.0 220 17 200 5.0 ECB18-6 2 230 18 800 5.5 240 20 500 6.0 220 20 100 5.9 CB18-26 ECB18-7 CBS18-26 2 230 21 900 6.4 240 23 900 7.0 220 22 900 6.7 ECB18-88 2 230 25 100 7.3 240 27 300 8.0 ECB18-1010 2 230 31 400 9.2 ECB18-1515 3 230 47 000 13.5 *Refer to local electrical codes to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). 3

OPTIONAL ELECTRIC HEAT DATA Indoor Coil Unit Electric Heat Unit and Shipping Weight Number of Elements (Steps) Volts Heating Capacity Input (1 phase) Btuh kw CB18-41 CBS18-41 CB18-51 CBS18-51 ECB18-5 5 lbs. (2 kg) ECB18-6 ECB18-7 ECB18-8 ECB18-10 ECB18-12.5 ECB18-15 ECB18-7 ECB18-8 ECB18-10 ECB18-12.5 ECB18-15 220 14 300 4.2 1 230 15 700 4.6 240 17 100 5.0 220 17 200 5.0 2 230 18 800 5.5 240 20 500 6.0 220 20 100 5.9 2 230 21 900 6.4 240 23 900 7.0 220 22 900 6.7 2 230 25 100 7.3 240 27 300 8.0 2 230 31 400 9.2 220 35 800 10.5 3 230 39 200 11.5 240 42 600 12.5 3 230 47 000 13.5 220 20 100 5.9 2 230 21 900 6.4 240 23 900 7.0 220 22 900 6.7 2 230 25 100 7.3 240 27 300 8.0 2 230 31 400 9.2 220 35 800 10.5 3 230 39 200 11.5 240 42 600 12.5 3 230 47 000 13.5 220 57 300 16.8 ECB18-20 16 lbs. (7 kg) 4 230 62 700 18.4 240 68 200 20.0 *Refer to local electrical codes to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). 4

OPTIONAL ELECTRIC HEAT DATA Indoor Coil Unit Electric Heat Unit and Shipping Weight Number of Elements (Steps) Volts Heating Capacity Input (1 phase) Btuh kw ECB18-1010 2 6 lbs. 230 31 400 9.2 (3 kg) 220 35 800 10.5 ECB18-12.512 3 11 lbs. 230 39 200 11.5 (5 kg) 240 42 600 12.5 ECB18-1515 3 11 lbs. 230 47 000 13.5 (5 kg) CB18-65 CBS18-65 220 57 300 16.8 ECB18-20 4 230 62 700 18.4 16 lbs. (7 kg) 240 68 200 20.0 220 71 700 21.0 ECB18-25 5 230 78 300 23.0 21 lbs. (10 kg) 240 85 300 25.0 220 86 000 25.2 ECB18-30 6 230 94 000 27.5 26 lbs. (12 kg) 240 102 400 30.0 *Refer to local electrical codes to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). BLOWER DATA CB18-26 AND CBS18-26 BLOWER PERFORMANCE High Medium Low in. w.g. Pa cfm L/s cfm L/s cfm L/s 0 0 1205 570 1085 510 840 395.10 25 1170 550 1050 495 810 380.20 50 1130 535 1020 480 785 370.30 75 1095 515 980 460 750 355.40 100 1050 495 940 445 720 340.50 125 1000 470 890 420 680 320 CB18-41 AND CBS18-41 BLOWER PERFORMANCE High Medium Low in. w.g. Pa cfm L/s cfm L/s cfm L/s 0 0 1400 660 1200 565 915 430.10 25 1360 640 1160 545 875 415.20 50 1315 620 1120 530 835 395.30 75 1265 595 1075 505 790 375.40 100 1215 575 1030 485 740 350.50 125 1160 545 985 465 685 325 CB18-51 AND CBS18-51 BLOWER PERFORMANCE High Medium-High Medium-Low Low in. w.g. Pa cfm L/s cfm L/s cfm L/s cfm L/s 0 0 1700 800 1345 635 1090 515 860 405.10 25 1680 795 1325 625 1080 510 840 395.20 50 1650 780 1300 615 1060 500 810 380.30 75 1615 760 1275 600 1025 485 765 360.40 100 1575 745 1245 590 985 465 720 340.50 125 1535 725 1205 570 935 440 670 315 CB18-65 AND CBS18-65 BLOWER PERFORMANCE OPTIONAL AIR FILTER RESISTANCE Air Volume Filter Resistance cfm L/s in. w.g. Pa 400 190 0.01 2 600 285 0.02 5 800 380 0.03 7 1000 470 0.05 12 1200 565 0.08 20 1400 660 0.08 20 1600 755 0.08 20 1800 850 0.09 22 2000 945 0.09 22 2200 1040 0.10 25 2400 1135 0.10 25 High Medium Low in. w.g. Pa cfm L/s cfm L/s cfm L/s 0 0 2380 1125 2170 1025 1920 905.10 25 2340 1105 2140 1010 1885 890.20 50 2295 1085 2105 995 1845 870.30 75 2245 1060 2060 970 1805 850.40 100 2195 1035 2015 950 1760 830.50 125 2140 1010 1970 930 1715 810 5

INSTALLATION CLEARANCES CB18-26 CBS18-26 CB18-41 CBS18-41 CB18-51 CBS18-51 CB18-65 CBS18-65 Cabinet 0 inch (0 mm) 0 inch (0 mm) 0 inch (0 mm) Plenum 0 inch (0 mm) 1 inch (25 mm) 1 inch (25 mm) *Duct *0 inch (0 mm) *1 inch (**25 mm) *1 inch (*25 mm) *Within 3 feet (90 cm) of the unit. DIMENSIONS mm (inches) 6

DIMENSIONS mm (inches) 7