SERVICE MANUAL MUX-2A28VB - MUX-2A59VB - E1 MUX-3A63VB - E1 MUX-3A63VB - MUX-2A70VB - MUX-4A73VB - E1 HFC. Multi system type Models

Similar documents
MUH-A07WV - MSC-A09WV - MUH-A09WV - MSC-A12WV - MUH-A12WV - Multi system type Models MUX-A10WV - MSC-A09WV - MUX-A19WV - MSC-A12WV -

SERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1. Wireless type Models HFC FLOOR AND CEILING TYPE AIR CONDITIONERS. No.

SERVICE MANUAL MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB368 R410A CONTENTS

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV -

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

SUZ-A09VR.TH SUZ-A12VR.TH SUZ-A18VR.TH SUZ-A24VR.TH

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MUH-GA50VB- MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1 OUTDOOR UNIT. No. OB368 REVISED EDITION-B. Wireless type Models HFC.

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1 OUTDOOR UNIT. No. OB381. Models HFC

MUH-24RV - MSH-30RV -

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy MUZ-GA35VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL. Wireless type Models MSZ-A09RV - (WH) MUZ-A09RV - MSZ-A12RV - (WH) MUZ-A12RV - E1 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC

SERVICE MANUAL MSC-09RV - E1 MU-07RV - MSC-09RV - MU-09RV - MSC-12RV - MU-12RV - MSC-07RV - MUH-07RV - MSC-09RV - MUH-09RV - MSC-12RV - MUH-12RV -

SERVICE MANUAL MFZ-KA25VA - MFZ-KA35VA - MFZ-KA35VA - E1. Wireless type Models FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUZ-GB50VA - MUZ-GB50VA - E2 OUTDOOR UNIT. No. OB455 REVISED EDITION-D. Wireless type Models HFC

TECHNICAL & SERVICE MANUAL

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

SERVICE MANUAL OUTDOOR UNIT MUZ-GA25VA - MUZ-GA25VA - MUZ-GA25VA - MUZ-GA25VA - MUZ-GA35VA - MUZ-GA35VA - MUZ-GA25VA(H)- MUZ-GA25VAH E4 MUZ-GA25VAH -

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG OUTDOOR UNIT. No. OBH767. Models HFC R32

TECHNICAL & SERVICE MANUAL R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH789

TECHNICAL & SERVICE MANUAL

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL. Wireless type Models MS-GA50VB - MS-GA60VB - MS-GA80VB - SPLIT-TYPE, AIR CONDITIONERS. No. OB369 CONTENTS

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

TECHNICAL & SERVICE MANUAL

SERVICE MANUAL MSC-GA20VB - (WH) MSC-GA25VB - (WH) MSC-GA35VB - (WH) Wireless type Models

Digital Inverter 4 series 8 & 10HP

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

[FLARE CONNECTION TYPE] ATTENTION

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA OUTDOOR UNIT. No. OBH543. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 INDOOR UNIT. No. OBH529. Models

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

TECHNICAL DATA & SERVICE MANUAL

INSTALLATION INSTRUCTIONS

SUZ-KA25VA2.TH SUZ-KA35VA2.TH SUZ-KA50VA2.TH SUZ-KA60VA2.TH SUZ-KA71VA2.TH

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

1. General Description

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

AIR CONDITIONER CASSETTE

TABLE OF CONTENTS RMXS-E8V1B

AIR CONDITIONER CASSETTE

TABLE OF CONTENTS ERSQ-AAY1

SUZ-SA71VA3.TH SUZ-SA100VA2.TH

SERVICE MANUAL R410A PUHZ-SP100VHA.UK PUHZ-SP125VHA.UK PUHZ-SP125VHA PUHZ-SP140VHA.UK PUHZ-SP140VHA PUHZ-SP100YHA.UK PUHZ-SP100YHA PUHZ-SP125YHA.

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

Energy Use in Refrigeration Systems

Room Air Conditioner Service and Parts Manual

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*R07LGC AO*R09LGC AO*R12LGC AO*R14LGC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

13-1. Temperature Regulator

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

38GL...G / 38GLS...G 38YY...G / 38YYS...G

TECHNICAL & SERVICE MANUAL SUZ-SA71VA.TH. R410A Outdoor unit SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. May 2014 HFC. No.OCH561 R410A CONTENTS

AIR CONDITIONER CONSOLE

TECHNICAL DATA & SERVICE MANUAL

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

SERVICE MANUAL R410A. June 2014 AIR TO WATER HEAT PUMP. No. OCH562. Outdoor unit [Model Name] [Service Ref.] PUHZ-W112VHA PUHZ-W112VHA-BS CONTENTS

EDUS Heat Pump - D-Series

Transcription:

SPLIT-TYPE, IR CDITIER SERVICE MNUL Multi system type Models E MUX-8VB - E MUX-59VB - E MUX-360VB - E MUX-363VB - E MUX-70VB - MUX-473VB - E HFC utilized R40 No. OB384 MUX-59VB - E MUX-360VB - E MUX-363VB - E MUX-70VB - E Indication of model name NOTE: s for indoor unit MSC-C0VB - E, MSC-C5VB - E or MSC-C35VB - E, refer to the service manual OB393. This manual describes technical data of outdoor unit. s for indoor unit MSC-G0VB - E, MSC-G5VB - E or MSC-G35VB - E, refer to the service manual OB385. CTENTS. TECHNICL CHNGES. PRT NMES ND FUNCTIS 6 3. INDOOR / OUTDOOR CORRESPDENCE TBLE 6 4. SPECIFICTI 7 5. NOISE CRITERI CURVES 6. OUTLINES ND DIMENSIS 3 7. WIRING DIGRM 6 8. REFRIGERNT SYSTEM DIGRM 9. PERFORMNCE CURVES 3 0. CTUTOR CTROL 55. TROUBLESHOOTING 56. DISSSEMBLY INSTRUCTIS 63 3. PRTS LIST 68

TECHNICL CHNGES MUX-0WV- MUX-0WV-. Indication of capacity has been changed. (BTU kw) MUX-9WV- MUX-WV- MUX-5WV- MUX-6WV- E E E E E E MUX-8VB- MUX-360VB- MUX-59VB- MUX-363VB- MUX-70VB- MUX-473VB-. Indication of capacity has been changed. (BTU kw). Size of stop valve (Gas) has been changed. ([.7 [9.5) E E E E E E

INFORMTI FOR THE IR CDITIER WITH R40 REFRIGERNT This room air conditioner adopts HFC refrigerant (R40) which never destroys the ozone layer. Pay particular attention to the following points, though the basic installation procedure is same as that for R conditioners. s R40 has working pressure approximate.6 times as high as that of R, some special tools and piping parts/ materials are required. Refer to the table below. Take sufficient care not to allow water and other contaminations to enter the R40 refrigerant during storage and installation, since it is more susceptible to contaminations than R. 3 For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R40. (Refer to. Refrigerant piping.) 4 Composition change may occur in R40 since it is a mixed refrigerant. When charging, charge liquid refrigerant to prevent composition change. Refrigeration Refrigerant oil New refrigerant Refrigerant R40 Composition (Ratio) HFC-3: HFC-5 (50%:50%) Refrigerant handling Pseudo-azeotropic refrigerant Chlorine Not included Safety group (SHRE) / Molecular weight 7.6 Boiling point (:) -5.4 Steam pressure [5:](Mpa).557 Saturated steam density [5:](Kg/K) 64 Combustibility Non combustible ODP w 0 GWP w 730 Refrigerant charge method From liquid phase in cylinder dditional charge on leakage Possible Kind Incompatible oil Color Non Smell Non w :Ozone Destruction Parameter : based on CFC- w :Global Warmth Parameter : based on CO Previous refrigerant R R (00%) Single refrigerant Included 86.5-40.8 0.94 44.4 Non combustible 0.055 700 Gas phase Possible Compatible oil Light yellow Non Compressor New Specification Current Specification The incompatible refrigeration oil easily separates from refrigerant and is in the upper layer inside the suction muffler. Raising position of the oil back hole enables to back the Since refrigerant and refrigeration oil are compatible each, refrigeration oil goes back to the compressor through the lower position oil back hole. refrigeration oil of the upper layer to flow back to the compressor. Suction muffler Suction muffler Compressor Oil back hole Refrigeration oil Compressor Oil back hole Refrigerant Refrigeration oil /Refrigerant NOTE : The unit of pressure has been changed to MPa on the international system of units(si unit system). The conversion factor is: (MPa [Gauge]) =0.(kgf/f [Gauge]) 3

Conversion chart of refrigerant temperature and pressure (MPa [Gauge]) 4.0 3.5 R40 Saturated liquid pressure 3.0.5.0.5.0 0.5 R NOTE : The unit of pressure has been changed to MPa on the international system of units(si unit system). The conversion factor is: (MPa [Gauge]) =0.(kgf/f [Gauge]) 0.0-0.5-30 -0-0 0 0 0 30 40 50 60 (:).Tools dedicated for the air conditioner with R40 refrigerant The following tools are required for R40 refrigerant. Some R tools can be substituted for R40 tools. The diameter of the service port on the stop valve in outdoor unit has been changed to prevent any other refrigerant being charged into the unit. Cap size has been changed from 7/6 UNF with 0 threads to / UNF with 0 threads. R40 tools Gauge manifold Can R tools be used? No Description R40 has high pressures beyond the measurement range of existing gauges. Port diameters have been changed to prevent any other refrigerant from being charged into the unit. Charge hose No Hose material and cap size have been changed to improve the pressure resistance. Gas leak detector No Dedicated for HFC refrigerant. Torque wrench Yes 6.35 mm and 9.5 mm Flare tool Yes Clamp bar hole has been enlarged to reinforce the spring strength in the tool. Flare gauge New Provided for flaring work (to be used with R flare tool). Vacuum pump Provided to prevent the back flow of oil. This adapter enables you to use New adapter vacuum pumps. Electronic scale for It is difficult to measure R40 with a charging cylinder because the New refrigerant charging refrigerant bubbles due to high pressure and high-speed vaporization No : Not Substitutable for R40 Yes : Substitutable for R40.Refrigerant piping Specifications Use the refrigerant pipes that meet the following specifications. Pipe For liquid For gas Outside diameter mm 6.35 9.5 Wall thickness 0.8 mm 0.8 mm Insulation material Heat resisting foam plastic Specific gravity 0.045 Thickness 8 mm Use a copper pipe or a copper-alloy seamless pipe with a thickness of 0.8 mm. Never use any pipe with a thickness less than 0.8mm, as the pressure resistance is insufficient. 4

Flaring work and flare nut Flaring work for R40 pipe differs from that for R pipe. For details of flaring work, refer to Installation manual FLRING WORK. Pipe diameter mm 6.35 9.5 Dimension of flare nut R40 7 R 7 3.Refrigerant oil pply the special refrigeration oil (accessories: packed with indoor unit) to the flare and the union seat surfaces. 4.ir purge Do not discharge the refrigerant into the atmosphere. Take care not to discharge refrigerant into the atmosphere during installation, reinstallation, or repairs to the refrigerant circuit. Use the vacuum pump for air purging for the purpose of environmental protection. 5.dditional charge For additional charging, charge the refrigerant from liquid phase of the gas cylinder. If the refrigerant is charged from the gas phase, composition change may occur in the refrigerant inside the cylinder and the outdoor unit. In this case, ability of the refrigeration cycle decreases or normal operation can be impossible. However, charging the liquid refrigerant all at once may cause the compressor to be locked. Thus, charge the refrigerant slowly. Indoor unit Refrigerant gas cylinder operating valve Union Liquid pipe Gas pipe Service port Stop valve Outdoor unit Gauge manifold valve (for R40) Charge hose (for R40) Refrigerant gas cylinder for R40 with siphon Refrigerant (liquid) Electronic scale for refrigerant charging 5

PRT NMES ND FUNCTIS OUTDOOR UNIT MUX-8VB- E ir inlet (back and side) Piping Drain hose ir outlet Drain outlet MUX-59VB- MUX-360VB- E E MUX-363VB- E MUX-70VB- E MUX-473VB- E ir inlet (Back and side) ir inlet (Back and side) ir outlet Piping Drainage hose ir outlet Piping Drainage hose Drain outlet Drain outlet 3 INDOOR / OUTDOOR CORRESPDENCE TBLE MUX-8VB - E MUX-59VB - E MUX-360VB - E MUX-363VB - MUX-70VB - MUX-473VB - E OUTDOOR UNIT MUX-8VB- E MUX-59VB- E MUX-360VB- E MUX-363VB- E MUX-70VB- E MUX-473VB- E E Combination of the connectable indoor units : B: MSC-C0VB- E or MSC-G0VB- E : MSC-C35VB- E or MSC-G35VB- E B: MSC-C0VB- E or MSC-G0VB- E : MSC-C5VB- E B: or C: MSC-G5VB- E : MSC-C35VB- E or MSC-G35VB- E B: MSC-C0VB- E or C: MSC-G0VB- E : B: MSC-C35VB- E or MSC-G35VB- E : MSC-C35VB- E or B: MSC-G35VB- E C: MSC-C5VB- E or D: MSC-G5VB- E 6

4 SPECIFICTI NOTE: s for specification of the indoor units, refer to service manual OB393 (MSC-C0/5/35V- OB385 (MSC-G0/5/35V- E ). Capacity Electrical data Compressor Fan motor Special remarks Outdoor model Function Outdoor unit power supply Indoor unit No. Capacity Dehumidification Outdoor air flow Power outlet Running current Power input uxiliary heater Power factor Starting current Compressor motor current Fan motor current kw R/h K /h W (kw) % Coefficient of performance (C.O.P) Model Output W Winding " resistance (at 0:) Model Winding " resistance (at 0:) Dimensions WOHOD mm Weight kg Sound level db Fan speed rpm Fan speed regulator Refrigerant filling kg capacity (R40) Refrigeration oil (Model) cc NOTE: Test conditions are based on ISO 55. Cooling : Indoor DB7 C WB9 C Outdoor DB35 C WB4 C Indoor-Outdoor piping length : 5m MUX-8VB - E Cooling Single phase 30V,50Hz Single or B.4 0.9 3.0 75,94 0 98.5 97.7.9.96 0.9 3.6 3.50 RN09VHSHT 600 C-R 3.87 C-S 6.4 R6V33-FC WHT-BLK 3 BLK-RED 780O540O55 35 49 85 0.90 (Room +B) 350 (NEO) Double +B.4O 0.O 3.5 730 Single 3.5.4 5.73,80 97. 5.6.65 E MUX-59VB - E Cooling Single phase 30V,50Hz Single B.4 0.9,460 0 3.5 785 97. 48.94 0.57.93 ) or Double +B 3.5+.4.4+0.9 8.96,005 97.3 8.39.84 MC : RN45VHSHT, MC : RN09VHSHT MC :,000, MC : 600 C-R.43 C-R 3.87 MC :, MC : C-S 3.80 C-S 6.4 R6V60-G WHT-BLK 90 BLK-RED 46 840O640O330 66 5 730.00 (Room ) 0.80 (Room B) MC : 60 (NEO), MC : 350 (NEO) 7

NOTE: s for specification of the indoor units, refer to service manual OB393 (MSC-C0/5/35V- OB385 (MSC-G0/5/35V- E ). Capacity Electrical data Compressor Fan motor Special remarks Outdoor model Function Outdoor unit power supply Indoor unit No. Capacity Dehumidification Outdoor air flow Power outlet Running current Power input uxiliary heater Power factor Starting current Compressor motor current Fan motor current kw R/h K /h W (kw) % Coefficient of performance (C.O.P) Model Output W Winding " resistance (at 0:) Model Winding " resistance (at 0:) Dimensions WOHOD mm Weight kg Sound level db Fan speed rpm Fan speed regulator Refrigerant filling kg capacity (R40) Refrigeration oil (Model) cc NOTE: Test conditions are based on ISO 55. Cooling : Indoor DB7 C WB9 C Outdoor DB35 C WB4 C Indoor-Outdoor piping length : 5m Single.6 0.9 3.64 85 97.3 3.07 3.06 Single B or C.9. 4.86,075 96. 4.9.6 MUX-360VB - E Cooling Single phase 30V,50Hz Double +B or +C.6+.8 0.9+.,460 0 8.8,850 98.3 47 7.6 0.57.8 E Double B+C.75O 0.3O 4.86,090 97.5 4.9 3.0 ) or MC : RN099VHSHT, MC : RN5VHSHT MC : 650, MC : 800 C-R 3.40 C-R.86 MC :, MC : C-S 4.56 C-S 5.7 R6V60-G WHT-BLK 90 BLK-RED 46 840O640O330 65 5 730 0.80 (Room ).00 (Room B+C) MC : 350 (NEO), MC : 350 (NEO) Triple +B+C.5+.75O 0.8+0.3O 8.4,885 97.5 7.84 3.0 8

NOTE: s for specification of the indoor units, refer to service manual OB393 (MSC-C0/5/35V- Capacity Electrical data Compressor Fan motor Special remarks OB385 (MSC-G0/5/35V- E ). Outdoor model Function Outdoor unit power supply Indoor unit No. Capacity Dehumidification Outdoor air flow Power outlet Running current Power input uxiliary heater Power factor Starting current Compressor motor current Fan motor current kw R/h K /h W (kw) % Coefficient of performance (C.O.P) Model Output W Winding " resistance (at 0:) Model Winding " resistance (at 0:) Dimensions WOHOD mm Weight kg Sound level db Fan speed rpm Fan speed regulator Refrigerant filling kg capacity (R40) Refrigeration oil (Model) cc NOTE: Test conditions are based on ISO 55. Cooling : Indoor DB7 C WB9 C Outdoor DB35 C WB4 C Indoor-Outdoor piping length 5m Single 3.5.4 5.73,80 97. 5.0.65 Single B or C.4 0.9 3.64 85 97.3.99 MUX-363VB - E Cooling Single phase 30V,50Hz Double +B or +C 3.5+.4.4+0.9,460 0 8.9,975 96.3 48 8.0 0.57.88 E Double B+C.45O 0.4 3.69 830 97.8.99 ) or.8 3. MC : RN45VHSHT, MC : RN09VHSHT MC :,000, MC : 600 C-R.43 C-R 3.87 MC :, MC : C-S 3.80 C-S 0.4 R6V60-G WHT-BLK 90 BLK-RED 46 840O640O330 67 5 730 0.85 (Room ) 0.85 (Room B+C) MC : 60 (NEO), MC : 350 (NEO) Triple +B+C 3.4+.45O.4+0.4 8.84,980 97.4 8.0 3.0 9

NOTE: s for specification of the indoor units, refer to service manual OB393 (MSC-C0/5/35V- OB385 (MSC-G0/5/35V- E ). Outdoor model Function Outdoor unit power supply MUX-70VB - E Cooling Single phase 30V,50Hz E ) or Indoor unit No. Single or B Double +B Capacity Electrical data Compressor Fan motor Special remarks Capacity Dehumidification Outdoor air flow Power outlet Running current Power input uxiliary heater Power factor Starting current Compressor motor current Fan motor current kw R/h K /h W (kw) % Coefficient of performance (C.O.P) Model Output W Winding " resistance (at 0:) Model Winding " resistance (at 0:) Dimensions WOHOD mm Weight kg Sound level db Fan speed rpm Fan speed regulator Refrigerant filling kg capacity (R40) Refrigeration oil (Model) cc NOTE: Test conditions are based on ISO 55. Cooling : Indoor DB7 C WB9 C Outdoor DB35 C WB4 C Indoor-Outdoor piping length : 5m 3.5.4 5.88,300,460 0 96. 96. 54 5.3 0.9 0.57.6.67 MC : RN45VHSHT, MC : RN45VHSHT MC :,000, MC :,000 C-R.43 C-R.43 MC :, MC : C-S 3.80 C-S 3.80 R6V60-G WHT-BLK 90 BLK-RED 46 840O640O330 68 5 730 0.95 (Room ) 0.95 (Room B) MC : 60 (NEO), MC : 60 (NEO) 3.5O.4O.49,540 0

NOTE: s for specification of the indoor units, refer to service manual OB393 (MSC-C0/5/35V- OB385 (MSC-G0/5/35V- E ). Capacity Electrical data Compressor Fan motor Special remarks Outdoor model Function Outdoor unit power supply Indoor unit No. Capacity Dehumidification Outdoor air flow Power outlet Running current Power input uxiliary heater Power factor Starting current Compressor motor current Fan motor current kw R/h K /h W (kw) % Coefficient of performance (C.O.P) Model Output W Winding " resistance (at 0:) Model Winding " resistance (at 0:) Dimensions WOHOD mm Weight kg Sound level db Fan speed rpm Fan speed regulator Refrigerant filling kg capacity (R40) Refrigeration oil (Model) cc Single or B 3.4. 5.8,80 97. 4.75.79 NOTE: Test conditions are based on ISO 55. Cooling : Indoor DB7 C WB9 C Outdoor DB35 C WB4 C Indoor-Outdoor piping length : 5m Single C or D.75. 4.54,05 97. 4.0.6 Double +B.95O 0.O MUX-473VB - E Cooling Single phase 30V,50Hz Double +C or +D or B+C or B+D Double C+D 3.4+.7.7O.+. 0.3O,760 0 E Triple +B+C or +B+D.95O+.8 0.O+. 5.46 9.57 4.78 9.6,0,095,060,05 96.4 95. 96.4 95. 5 4.93 9.04 4.5 9.08 0.53 3.0.8 3.0 3.0 MC : RN45VHSHT, MC : RN5VHSHT MC :,000, MC : 800 C-R.43 C-R.86 MC :, MC : C-S 3.80 C-S 5.7 R6V60-F WHT-BLK 79 BLK-RED 80 840O850O330 76 5 730.05 (Room +B).05 (Room C+D) MC : 60 (NEO), MC : 350 (NEO) ) or Triple +C+D or B+C+D 3.4+.7O.+0.3O 9.66,40 96.3 9.3 3.0 Four +B+C+D.95O+.7O 0.O+0.3O 9.75,0 98.6 9. 3.09

5 NOISE CRITERI CURVES MUX-8VB- E FUNCTI COOL SPL(dB()) 49 LINE MUX-59VB - E MUX-360VB - E MUX-363VB - E MUX-70VB - E FUNCTI COOL SPL(dB()) 5 LINE 90 Test conditions. Cooling : DB7: WB9: 90 Test conditions. Cooling :DB35: WB4: OCTVE BND SOUND PRESSURE LEVEL, db re 0.000 MICRO BR 80 70 60 50 40 30 0 0 PPROXIMTE TERESHOLD OF HERING FOR CTINUOUS NOISE 63 5 50 500 000 000 4000 8000 NC-70 NC-60 NC-50 NC-40 NC-30 NC-0 OCTVE BND SOUND PRESSURE LEVEL, db re 0.000 MICRO BR 80 70 60 50 40 30 0 0 PPROXIMTE TERESHOLD OF HERING FOR CTINUOUS NOISE 63 5 50 500 000 000 4000 8000 NC-70 NC-60 NC-50 NC-40 NC-30 NC-0 BND CENTER FREQUENCIES, Hz BND CENTER FREQUENCIES, Hz MUX-473VB - E FUNCTI SPL(dB()) LINE COOL 5 90 Test conditions. Cooling :DB35: WB4: OCTVE BND SOUND PRESSURE LEVEL, db re 0.000 MICRO BR 80 70 60 50 40 30 0 0 PPROXIMTE TERESHOLD OF HERING FOR CTINUOUS NOISE 63 5 50 500 000 000 4000 8000 BND CENTER FREQUENCIES, Hz NC-70 NC-60 NC-50 NC-40 NC-30 NC-0

6 OUTLINES ND DIMENSIS OUTDOOR UNIT MUX-8VB- E ir in REQUIRED SPCE 00mm or more 00mm or more Unit: mm 30 00mm or more 09 3 ir in Drainage 3holes [33 47 0 ir out 55 85 30 5 400mm or more 350mm or more Service panel 540 Liquid refrigerant pipe joint (flared) [6.35 60 0 40 500 780 56 6 76 6 76 0 0- Gas refrigerant pipe joint (flared) [9.5 MUX-59VB- E Drainage 3holes {33 73 438 ir in 500 30 00mm or more Open as a rule 500mm or more if the front and both sides are open 00mm or more 00mm or more if there are obstacles to both sides 5 34 ir in 330 360 00 ir out 40 Open as a rule 500mm or more if the back, both sides and top are open 350mm or more 840 6 Service panel Liquid refrigerant pipe joint (flared) {6.35 30 640 0 0 } } B UNIT UNIT 76 505050 Gas refrigerant pipe joint (flared) {9.5 65 80 64 Gas refrigerant pipe joint (flared) {9.5 3

OUTDOOR UNIT MUX-360VB- E MUX-363VB- E Open as a rule 500mm or more if the front and both sides are open Unit: mm Drainage 3 holes {33 73 438 ir in 500 00mm or more 00mm or more 00mm or more if there are obstacles on both sides 5 30 ir in 00 ir out 40 330 34 360 Open as a rule 500mm or more if the back, both sides and top are open 350mm or more 840 6 Service panel Liquid refrigerant pipe joint (flared) {6.35 0 30 640 0 } C UNIT } } B UNIT UNIT 76 50505050 50 65 64 Gas refrigerant pipe joint (flared) {9.5 MUX-70VB- E Open as a rule 500mm or more if the front and both sides are open Drainage 3 holes {33 73 438 ir in 500 00mm or more 00mm or more 00mm or more if there are obstacles on both sides 5 30 ir in 00 ir out 40 330 34 360 Open as a rule 500mm or more if the back, both sides and top are open 350mm or more 840 6 Service panel 30 640 0 0 } } B UNIT UNIT Liquid refrigerant pipe joint (flared) {6.35 76 505050 80 64 Gas refrigerant pipe joint (flared) {9.5 4

OUTDOOR UNIT MUX-473VB- E Open as a rule 500mm or more if the front and both sides are open Unit: mm Drainage 3 holes {33 5 00 73 438 ir in 34 30 40 00mm or more 00mm or more 00mm or more if there are obstacles on both sides 330 ir in 360 ir out 840 500 65 6 Open as a rule 500mm or more if the back, both sides and top are open Service panel Liquid refrigerant pipe joint (flared) {6.35 350mm or more 850 430 0 0 Gas refrigerant pipe joint (flared) {9.5 D Unit C Unit B Unit Unit 76 50 5050 5050 50 50 80 Gas refrigerant pipe joint (flared) {9.5 60 5

7 WIRING DIGRM MUX-8VB - E OUTDOOR UNIT MODEL WIRING DIGRM POWER SUPPLY ~ / N 30V 50Hz CIRCUIT BREKER TO INDOOR UNIT No. CNECTING V TO INDOOR UNIT No.B CNECTING V TB L N PE BRN DSR TB WHT 7 X 8 BLK YLW7 X 8 ORN BRN R R 5C NO BRN 5C F6 TB3 COM WHT BRN 5 X 5 X F6 3 6 X 4 3 6 X 4 BRN BRN BRN WHT WHT TB3 WHT C C RED S WHT BLK C MC WHT WHT BLK MF RED 3 RED R R SYMBOL NME SYMBOL NME SYMBOL NME C C DSR F6,F6 MC COMPRESSOR CPCITOR OUTDOOR FN CPCITOR SURGE BSORBER FUSE() COMPRESSOR(INNER PROTECTOR) MF TB,TB,TB3 X X R OUTDOOR FN MOTOR(INNER FUSE) TERMINL BLOCK RELY() RELY(B) SOLENOID COIL R R 5C SOLENOID COIL() SOLENOID COIL(B) COMPRESSOR CTCTOR NOTE:. bout the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.. Use copper conductors only. (For field wiring) 3. Symbols below indicate. /: Terminal block, : Connector 6

MUX-59VB - E MUX-70VB - E OUTDOOR UNIT MODELS WIRING DIGRM POWER SUPPLY ~/N 30V 50Hz TO INDOOR UNIT CNECTING V TO INDOOR UNIT B CNECTING V TB L N PE CIRCUIT BREKER TB GRN/YLW BRN BRN YLW ORN DSR TB4 3 3 CN73 CN7 BRN 3 F6 SR86 CN90 OUTDOOR CTROL P.C. BORD NR6 T6 BRN X5 3 X5 BRN X5 3 4 X5 4 C RED S BLK R MC WHT C RED S BLK R MC WHT C C CN9 3 4 5 6 LD LD WHT BLK MF6 RED RED RED C6 SYMBOL NME SYMBOL NME SYMBOL NME C C C6 DSR F6 COMPRESSOR CPCITOR(MC) COMPRESSOR CPCITOR(MC) OUTDOOR FN CPCITOR SURGE BSORBER FUSE(3.5) MC MC MF6 NR6 SR86 COMPRESSOR(INNER PROTECTOR) COMPRESSOR(INNER PROTECTOR) OUTDOOR FN MOTOR (INNER PROTECTOR) SURGE BSORBER OUTDOOR FN RELY TB TB~TB4 T6 X5 X5 TERMINL BLOCK TERMINL BLOCK TRNSFORMER COMPRESSOR CTCTOR(MC) COMPRESSOR CTCTOR(MC) NOTE:. bout the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.. Use copper conductors only. (For field wiring) 3. Symbols below indicate. /: Terminal block, : Connector 7

MUX-360VB - E OUTDOOR UNIT MODEL WIRING DIGRM POWER SUPPLY ~/N 30V 50Hz BRN BRN TB4 3 3 3 3 NR6 OUTDOOR CTROL P.C. BORD T6 CN8 3 3 4 CN85 3 3 4 CN86 3 LD MF6 RB R3 R4 C6 WHT WHT BRN BRN X5 X5 BLK R MC C BLK WHT RED RED RED LD SR86 SR863 SR866 SR865 BRN TB TB3 CN9 CN90 3 4 5 6 X5 X5 CN74 CN73 CN7 F6 GRN/YLW TO INDOOR UNIT CNECTING V TO INDOOR UNIT B CNECTING V TO INDOOR UNIT C CNECTING V L N CIRCUIT BREKER TB PE YLW ORN WHT C RED S C RED S BLK R MC C DSR SYMBOL NME SYMBOL NME SYMBOL NME C C C6 DSR F6 MC MC COMPRESSOR CPCITOR(MC) COMPRESSOR CPCITOR(MC) OUTDOOR FN CPCITOR SURGE BSORBER FUSE(3.5) COMPRESSOR(INNER PROTECTOR) COMPRESSOR(INNER PROTECTOR) MF6 NR6 SR86 SR863 SR865 SR866 TB OUTDOOR FN MOTOR(INNER PROTECTOR) SURGE BSORBER OUTDOOR FN RELY RELY (RB) RELY (C) (R4) RELY (B) (R3) TERMINL BLOCK TB~TB4 T6 X5 X5 RB R3 R4 TERMINL BLOCK TRNSFORMER COMPRESSOR CTCTOR(MC) COMPRESSOR CTCTOR(MC) SOLENOID COIL SOLENOID COIL (B) SOLENOID COIL (C) NOTE:. bout the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.. Use copper conductors only. (For field wiring) 3. Symbols below indicate. /: Terminal block, : Connector 8

MUX-363VB - E OUTDOOR UNIT MODEL WIRING DIGRM POWER SUPPLY ~/N 30V 50Hz BRN BRN TB4 3 3 3 3 NR6 OUTDOOR CTROL P.C. BORD T6 CN8 3 3 4 CN85 3 3 4 CN86 3 WHT WHT LD BRN BRN X5 X5 BLK BLK WHT RED RED RED LD SR86 SR863 SR866 SR865 BRN TB TB3 CN9 CN90 3 4 5 6 X5 X5 CN74 CN73 CN7 F6 GRN/YLW TO INDOOR UNIT CNECTING V TO INDOOR UNIT B CNECTING V TO INDOOR UNIT C CNECTING V L N CIRCUIT BREKER TB PE YLW ORN WHT C C BLK RED R RED S MC DSR S C R MC C MF6 RB R3 R4 C6 SYMBOL NME SYMBOL NME SYMBOL NME C C C6 DSR F6 MC MC COMPRESSOR CPCITOR(MC) COMPRESSOR CPCITOR(MC) OUTDOOR FN CPCITOR SURGE BSORBER FUSE(3.5) COMPRESSOR(INNER PROTECTOR) COMPRESSOR(INNER PROTECTOR) MF6 NR6 SR86 SR863 SR865 SR866 TB OUTDOOR FN MOTOR(INNER PROTECTOR) SURGE BSORBER OUTDOOR FN RELY RELY (RB) RELY (C) (R4) RELY (B) (R3) TERMINL BLOCK TB~TB4 T6 X5 X5 RB R3 R4 TERMINL BLOCK TRNSFORMER COMPRESSOR CTCTOR(MC) COMPRESSOR CTCTOR(MC) SOLENOID COIL SOLENOID COIL (B) SOLENOID COIL (C) NOTE:. bout the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.. Use copper conductors only. (For field wiring) 3. Symbols below indicate. /: Terminal block, : Connector 9

MUX-473VB - E OUTDOOR UNIT MODEL WIRING DIGRM TB4 L TB BRN BRN BRN N BRN PE CIRCUIT BREKER GRN/YLW DSR BRN POWER SUPPLY ~/N 30V 50Hz TO INDOOR UNIT D CNECTING V TB WHT 3 3 OUTDOOR CTROL P.C. BORD CN90 X5 3 4 X5 TO INDOOR UNIT C CNECTING V ORN BRN YLW 3 3 3 6 T6 3 4 X5 X5 WHT BLK RED RED RED MF6 R R R3 R4 R RB C6 C BLK C BLK RED S MC R C WHT RED S MC R C WHT CN7 CN7 CN73 CN74 F6 TO INDOOR UNIT B CNECTING V TB3 SR86 SR868 LD LD CN9 3 4 5 NR6 3 3 3 3 SR867 SR866 SR865 SR864 3 3 SR863 TO INDOOR UNIT CNECTING V CN83 CN84 CN85 CN86 CN8 CN8 SYMBOL NME SYMBOL NME SYMBOL NME C C C6 DSR F6 MC MC MF6 NR6 COMPRESSOR CPCITOR(MC) COMPRESSOR CPCITOR(MC) OUTDOOR FN CPCITOR SURGE BSORBER FUSE(3.5) COMPRESSOR(INNER PROTECTOR) COMPRESSOR(INNER PROTECTOR) OUTDOOR FN MOTOR(INNER PROTECTOR) SURGE BSORBER SR86 SR863 SR864 SR865 SR866 SR867 SR868 TB~TB4 T6 OUTDOOR FN RELY RELY (RB) RELY (R) RELY (D) (R4) RELY (C) (R3) RELY (B) (R) RELY () (R) TERMINL BLOCK TRNSFORMER X5 X5 R RB R R R3 R4 COMPRESSOR CTCTOR(MC) COMPRESSOR CTCTOR(MC) SOLENOID COIL (BLNCE) SOLENOID COIL (BLNCE) SOLENOID COIL () SOLENOID COIL (B) SOLENOID COIL (C) SOLENOID COIL (D) NOTE:. bout the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.. Use copper conductors only. (For field wiring) 3. Symbols below indicate. /: Terminal block, : Connector 0

8 REFRIGERNT SYSTEM DIGRM Unit : mm MUX-8VB- E INDOOR UNIT OUTDOOR UNIT Room temperature thermistor RT [9.5 (With insulation) Solenoid valve Strainer R #00 UNIT Indoor heat exchanger Stop valve with service port Capillary tube [3.0 x [.4 x 000 Muffler Flared connection Indoor coil thermistor RT Room temperature thermistor RT [6.35 (With insulation) [9.5 (With insulation) Stop valve Solenoid valve R Capillary tube [3.0 x [.4 x 400 Capillary tube [3.0 x [.6 x 900 Compressor Strainer #00 Outdoor heat exchanger UNIT B Indoor heat exchanger Flared connection Stop valve with service port Solenoid valve R Indoor coil thermistor RT [6.35 (With insulation) Stop valve Capillary tube [3.0 x [.4 x 400 Refrigerant flow in cooling MX. REFRIGERNT PIPING LENGTH & MX. HEIGHT DIFFERENCE Indoor unit Indoor unit B Max. length difference 0m Outdoor unit MUX-8VB- E dditional piping max. length 5m DDITIL REFRIGERNT CHRGE (R40:g) UNIT No. Outdoor unit precharged Refrigerant piping length (one way) 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 30 m m m m m m m m m m m m m m m m m m m m m PIPING PREPRTI Table below shows the specifications of pipes commercially available. unit + UNIT No. and B B unit UNIT 900g 0 0 0 30 40 50 60 70 80 90 00 0 0 30 40 50 60 70 80 90 00 Pipe Outside diameter Insulation mm thickness Insulation material For liquid 6.35 8 mm Heat resisting foam plastic For gas 9.5 8 mm 0.045 specific gravity Ensure that the refrigerant pipes are well insulated to prevent condensation. 3 Refrigerant bending radius must be 0cm or more.

Unit : mm MUX-59VB- E INDOOR UNIT OUTDOOR UNIT Room temperature thermistor RT [9.5 (With insulation) UNIT Indoor heat exchanger Stop valve with service port Muffler Flared connection Indoor coil thermistor RT Stop valve Compressor() Room temperature thermistor RT [6.35 (With insulation) [9.5 (With insulation) Capillary tube [3.0 x [.4 x 850 Strainer #00 Muffler Outdoor heat exchanger UNIT B Indoor heat exchanger Flared connection Stop valve with service port Indoor coil thermistor RT [6.35 (With insulation) Stop valve Capillary tube [3.0 x [.4 x 00 Compressor(B) Strainer #00 Refrigerant flow in cooling

MX.REFRIGERNT PIPING LENGTH & MX. HEIGHT DIFFERENCE Indoor unit Indoor unit B L H LB H Outdoor unit MUX-59VB - E UNIT No. Pipe length Height difference (H) No. of bends Max. limits B L LB 5m 5m 0m 0m 0 0 DDITIL REFRIGERNT CHRGE (R40:g) unit Outdoor unit precharged 7m 8m Refrigerant piping length (one way) 9m 0m m m 3m 4m 5m 000g 0 0 40 60 80 00 0 40 60 B unit Outdoor unit precharged 7m 8m Refrigerant piping length (one way, unit total) 9m 0m m m 3m 4m 5m 800g 0 0 40 60 80 00 0 40 60 PIPING PREPRTI Table below shows the specifications of pipes commercially available. UNIT No. Pipe Outside diameter mm Insulation thickness Insulation material unit B unit For liquid For gas For liquid For gas 6.35 9.5 6.35 9.5 8mm 8mm 8mm 8mm Heat resisting foam plastic 0.045 specific gravity Ensure that the refrigerant pipes are well insulated to prevent condensation. 3Refrigerant bending radius must be 0cm or more. 3

Unit : mm MUX-360VB- E INDOOR UNIT OUTDOOR UNIT Room temperature thermistor RT [9.5 (With insulation) UNIT Indoor heat exchanger Stop valve with service port Muffler Flared connection Indoor coil thermistor RT Stop valve Compressor() Room temperature thermistor RT [6.35 (With insulation) [9.5 (With insulation) Stop valve with service port Capillary tube [3.0 x [.4 x 950 Strainer #00 Strainer #00 Solenoid valve RB Muffler Outdoor heat exchanger UNIT B Indoor heat exchanger Indoor coil thermistor RT Room temperature thermistor RT Flared connection [6.35 (With insulation) [9.5 (With insulation) Stop valve Solenoid valve R3 Capillary tube [3.0 x [.6 x 900 Capillary tube [3.0 x [.4 x 000 Capillary tube [3.0 x [.6 x 900 Compressor(B,C) Strainer #00 UNIT C Indoor heat exchanger Flared connection Stop valve with service port Stop valve Solenoid valve R4 Refrigerant flow in cooling Indoor coil thermistor RT [6.35 (With insulation) Capillary tube [3.0 x [.6 x 900 4

MX.REFRIGERNT PIPING LENGTH & MX. HEIGHT DIFFERENCE Indoor unit Indoor unit B Indoor unit C L H LB H LC H Outdoor unit MUX-360VB - E UNIT No. Pipe length Height difference (H) No. of bends Max. limits B C L LB LC 5m 5m 5m LB + LC Total 30m 0m 0m 0m 0 0 Total 0 5 DDITIL REFRIGERNT CHRGE (R40:g) unit Outdoor unit precharged 7m 8m 9m Refrigerant piping length (one way) 0m m m 3m 4m 5m 800g 0 0 40 50 80 00 0 40 60 B unit + C unit Outdoor unit precharged Refrigerant piping length (one way, unit total) 0 3 4 5 6 7 8 9 0 3 4 5 6 8 7 9 30 m m m m m m m m m m m m m m m m m m m m m 000g 0 0 0 30 40 50 60 70 80 90 00 0 0 30 40 50 60 80 70 90 00 PIPING PREPRTI Table below shows the specifications of pipes commercially available. UNIT No. Pipe Outside diameter mm Insulation thickness Insulation material, B and C unit For liquid For gas 6.35 9.5 8mm 8mm Heat resisting foam plastic 0.045 specific gravity Ensure that the refrigerant pipes are well insulated to prevent condensation. 3Refrigerant bending radius must be 00mm or more. 5

Unit : mm MUX-363VB- E INDOOR UNIT OUTDOOR UNIT Room temperature thermistor RT [9.5 (With insulation) UNIT Indoor heat exchanger Stop valve with service port Muffler Flared connection Indoor coil thermistor RT Stop valve Compressor() Strainer #00 Room temperature thermistor RT [6.35 (With insulation) [9.5 (With insulation) Stop valve with service port Capillary tube [3.0 x [.6 x 900 Strainer #00 Solenoid valve RB Muffler Outdoor heat exchanger UNIT B Indoor heat exchanger Indoor coil thermistor RT Room temperature thermistor RT Flared connection [6.35 (With insulation) [9.5 (With insulation) Stop valve Solenoid valve R3 Capillary tube [3.0 x [.6 x 900 Capillary tube [3.0 x [.4 x 000 Capillary tube [3.0 x [.6 x700 Compressor(B,C) Strainer #00 UNIT C Indoor heat exchanger Flared connection Stop valve with service port Stop valve Solenoid valve R4 Refrigerant flow in cooling Indoor coil thermistor RT [6.35 (With insulation) Capillary tube [3.0 x [.6 x 900 6

MX.REFRIGERNT PIPING LENGTH & MX. HEIGHT DIFFERENCE Indoor unit Indoor unit B Indoor unit C L H LB H LC H Outdoor unit MUX-363VB - E UNIT No. Pipe length Height difference (H) No. of bends Max. limits Unit Unit B Unit C L LB LC 5m 5m 5m LB + LC Total 30m 0m 0m 0m 0 0 Total 0 5 DDITIL REFRIGERNT CHRGE (R40:g) Unit Unit B + Unit C Outdoor unit precharged 850g Outdoor unit precharged 850g Refrigerant piping length (one way) 7m 8m 9m 0m m m 3m 4m 5m 0 0 40 60 80 00 0 40 60 Refrigerant piping length (one way, unit total) 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 30 m m m m m m m m m m m m m m m m m m m m m 0 0 0 30 40 50 60 70 80 90 00 0 0 30 40 50 60 70 80 90 00 PIPING PREPRTI Table below shows the specifications of pipes commercially available. UNIT No. Pipe Outside diameter mm Insulation thickness Insulation material Unit Unit B and Unit C For liquid For gas For liquid For gas 6.35 9.5 6.35 9.5 8mm 8mm 8mm 8mm Heat resisting foam plastic 0.045 specific gravity Ensure that the refrigerant pipes are well insulated to prevent condensation. 3Refrigerant bending radius must be 00mm or more. 7

Unit : mm MUX-70VB- E INDOOR UNIT OUTDOOR UNIT Room temperature thermistor RT [9.5 (With insulation) UNIT Indoor heat exchanger Stop valve with service port Muffler Flared connection Indoor coil thermistor RT Stop valve Compressor() Room temperature thermistor RT [6.35 (With insulation) [9.5 (With insulation) Capillary tube [3.0 x [.4 x 700 Strainer #00 Muffler Outdoor heat exchanger UNIT B Indoor heat exchanger Flared connection Stop valve with service port Indoor coil thermistor RT [6.35 (With insulation) Stop valve Capillary tube [3.0 x [.4 x 700 Compressor(B) Strainer #00 Refrigerant flow in cooling 8

MX.REFRIGERNT PIPING LENGTH & MX. HEIGHT DIFFERENCE Indoor unit Indoor unit B L H LB H Outdoor unit MUX-70VB - E UNIT No. Pipe length Height difference (H) No. of bends Max. limits B L LB 5m 5m 0m 0m 0 0 DDITIL REFRIGERNT CHRGE (R40:g) unit Outdoor unit precharged 7m 8m Refrigerant piping length (one way) 9m 0m m m 3m 4m 5m 950g 0 0 40 60 80 00 0 40 60 B unit Outdoor unit precharged 7m 8m Refrigerant piping length (one way) 9m 0m m m 3m 4m 5m 950g 0 0 40 60 80 00 0 40 60 PIPING PREPRTI Table below shows the specifications of pipes commercially available. UNIT No. Pipe Outside diameter mm Insulation thickness Insulation material and B unit For liquid For gas 6.35 9.5 8mm 8mm Heat resisting foam plastic 0.045 specific gravity Ensure that the refrigerant pipes are well insulated to prevent condensation. 3Refrigerant bending radius must be 0cm or more. 9

Unit : mm MUX-473VB- E INDOOR UNIT OUTDOOR UNIT Room temperature thermistor RT {9.5 (With insulation) Strainer #00 Solenoid valve R UNIT Indoor heat exchanger Stop valve with service port Capillary tube [3.0 x [.4 x 000 Muffler Flared connection Indoor coil thermistor RT Room temperature thermistor RT {6.35 (With insulation) {9.5 (With insulation) Stop valve Solenoid valve R Capillary tube [3.0 x [.8 x 700 Capillary tube [3.0 x [.0 x 700 Compressor Strainer #00 UNIT B Indoor heat exchanger Flared connection Stop valve with service port Solenoid valve R Indoor coil thermistor RT {6.35 (With insulation) Stop valve Capillary tube [3.0 x [.8 x 700 Room temperature thermistor RT {9.5 (With insulation) Strainer #00 Solenoid valve RB Outdoor heat exchanger UNIT C Indoor heat exchanger Stop valve with service port Capillary tube [3.0 x [.4 x 000 Muffler Flared connection Indoor coil thermistor RT Solenoid valve R3 Compressor Room temperature thermistor RT {6.35 (With insulation) {9.5 (With insulation) Stop valve Capillary tube [3.0 x [.6 x 600 Capillary tube [3.0 x [.8 x 800 Strainer #00 UNIT D Indoor heat exchanger Flared connection Stop valve with service port Solenoid valve R4 Indoor coil thermistor RT {6.35 (With insulation) Stop valve Capillary tube [3.0 x [.6 x 600 Refrigerant flow in cooling 30

MX.REFRIGERNT PIPING LENGTH & MX. HEIGHT DIFFERENCE Indoor unit Indoor unit B Indoor unit C Indoor unit D L H LB H LC H LD H Outdoor unit MUX-473VB- E UNIT No. Pipe length Height difference (H) No. of bends Max. limits B C D L LB LC LD 5m 5m 5m 5m L + LB LC + LD Total 30m Total 30m 0m 0m 0m 0m 0 0 0 0 Total 5 Total 5 DDITIL REFRIGERNT CHRGE (R40:g) UNIT No. Outdoor unit precharged Refrigerant piping length (one way, unit total) 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 30 m m m m m m m m m m m m m m m m m m m m m unit + B unit 050g 0 0 0 30 40 50 60 70 80 90 00 0 0 30 40 50 60 70 80 90 00 C unit + D unit 050g 0 0 0 30 40 50 60 70 80 90 00 0 0 30 40 50 60 70 80 90 00 PIPING PREPRTI Table below shows the specifications of pipes commercially available. UNIT No. Pipe Outside diameter mm Insulation thickness Insulation material C and and B D unit unit For liquid For gas For liquid For gas 6.35 9.5 6.35 9.5 8mm 8mm 8mm 8mm Heat resisting foam plastic 0.045 specific gravity Ensure that the refrigerant pipes are well insulated to prevent condensation. 3Refrigerant bending radius must be 0cm or more. 3

9 PERFORMNCE CURVES MUX-8VB - E MUX-363VB - E MUX-59VB - E MUX-70VB - E MUX-360VB - E MUX-473VB - E The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions, since operating conditions vary according to the areas where these units are installed. The following information has been provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve. () GURNTEED VOLTGE 98~64V, 50Hz () IR FLOW ir flow should be set at MX. (3) MIN REDINGS () Indoor intake air wet-bulb temperature : CWB () Indoor outlet air wet-bulb temperature : CWB (3) Outdoor intake air dry-bulb temperature : CDB (4) Total input: W Indoor air wet/dry-bulb temperature difference on the left side of the chart on the next page shows the difference between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service. How to measure the indoor air wet-bulb/dry-bulb temperature difference. ttach at least sets of wet-and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least sets of wet-and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air speed is high.. ttach at least sets of wet-and dry-bulb thermometers to the outdoor air intake. Cover the thermometers to prevent direct rays of the sun. 3. Check that the air filter is cleaned. 4. Open windows and doors of room. 5. Press the EMERGENCY OPERTI switch once to start the EMERGENCY COOL MODE. 6. When system stabilizes after more than 5 minutes, measure temperature and take an average temperature. 7. 0 minutes later, measure temperature again and check that the temperature does not change. INDOOR UNIT OUTDOOR UNIT Wet-and dry-bulb thermometers Wet-and dry-bulb thermometers 3

9-.CPCITY ND THE INPUT CURVES (E INDOOR UNIT WITH E OUTDOOR UNIT) Indoor air WB temperature difference (deg.) 9.4 8.6 7.8 7. 6.3 5.6 0. 9.4 8.5 7.7 6.9 6. 9.4 8.6 7.8 7. 6.3 5.6 9.5 8.7 7.9 7. 6.4 5.7 0.8 9.9 9.0 8. 7.3 6.4 0. 9.4 8.5 7.7 6.9 6. 9.4 8.6 7.8 7. 6.3 5.6 0. 9.4 8.5 7.7 6.9 6. 0. 9.4 8.5 7.7 6.9 6. 0.3 9.4 8.6 7.7 6.9 6. MUX-8VB- E (Indoor unit or B) MUX-59VB- E (Indoor unit ) MUX-59VB- E (Indoor unit B) MUX-360VB- E (Indoor unit ) MUX-360VB- E (Indoor unit B or C) MUX-363VB- E (Indoor unit ) MUX-363VB- E (Indoor unit B or C) MUX-70VB- E (Indoor unit or B) MUX-473VB- E (Indoor unit or B) MUX-473VB- E (Indoor unit C or D) 9-.OUTDOOR LOW PRESSURE ND OUTDOOR UNIT CURRENT COOL operation Both indoor and outdoor unit are under same temperature/humidity condition. Dry-bulb temperature Relative humidity (%) 0 5 50 60 30 70 ➁ ir flow should be set at MX. 3 The unit of pressure has been changed to MPa on the international system of units(si unit system). The conversion factor is : (MPa[Gauge]) =0.(kgf/f[Gauge] ) MUX-8VB- E (kgf/f[gauge])(mpa[gauge]) Single operation (Unit or B).3 4.0 3 Outdoor low pressure (kgf/f[gauge]).. 0.0 9 0.9 8 0.8 7 0.7 (kgf/f[gauge])(mpa[gauge]). Outdoor low pressure (kgf/f[gauge]). 0.0 9 0.9 8 0.8 7 0.7 6 0.6 30V MUX-59VB- E 30V Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 3.5 3.0.5.0 Single operation (Unit ) (kgf/f[gauge])(mpa[gauge]) Single operation (Unit B) 7.0.3 3 4.0 Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 6.0 5.0 4.0 3.0 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) C) (%) 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) Outdoor low pressure (kgf/f[gauge]).. 0.0 9 0.9 8 0.8 7 0.7 30V Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 3.5 3.0.5.0 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 33

MUX-360VB- E (kgf/f[gauge])(mpa[gauge]). Outdoor low pressure (kgf/f[gauge]). 0.0 9 0.9 8 0.8 7 0.7 6 0.6 30V Single operation (Unit ) 5.0 Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 4.0 3.0.0 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) (kgf/f[gauge])(mpa[gauge]) Single operation (Unit B or C) 0.9 6.0 9 Outdoor low pressure (kgf/f[gauge]) 8 0.8 7 0.7 6 0.6 5 0.5 4 0.4 30V Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 5.0 4.0 3.0 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) MUX-363VB- E (kgf/f[gauge])(mpa[gauge]). Outdoor low pressure (kgf/f[gauge]). 0.0 9 0.9 8 0.8 7 0.7 6 0.6 Single operation (Unit ) 7.0 30V Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 6.0 5.0 4.0 30V (kgf/f[gauge])(mpa[gauge]) Single operation (Unit B or C).3 4.0 3 Outdoor low pressure (kgf/f[gauge]) 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%).. 0.0 9 0.9 8 0.8 7 0.7 30V Outdoor unit current () 3.5 3.0.5 0 5 30.0 ( C) 50 60 70 (%) mbient temperature( C) mbient humidity(%) 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) MUX-70VB- E (kgf/f[gauge])(mpa[gauge]) Single operation (Unit or B). 7.0 Outdoor low pressure (kgf/f[gauge]). 0.0 9 0.9 8 0.8 7 0.7 6 0.6 MUX-473VB- E 30V Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 6.0 5.0 4.0 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) (kgf/f[gauge])(mpa[gauge]) Single operation (Unit or B) (kgf/f[gauge])(mpa[gauge]) Single operation (Unit C or D). 6.0. 5.0 Outdoor low pressure (kgf/f[gauge]) 0.0 9 0.9 8 0.8 7 0.7 6 0.6 30V Outdoor unit current () 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 5.0 4.0 3.0 30V Outdoor low pressure (kgf/f[gauge]) 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 0.0 9 0.9 8 0.8 7 0.7 6 0.6 30V Outdoor unit current () 4.0 3.0 0 5 30 ( C).0 50 60 70 (%) mbient temperature( C) mbient humidity(%) 30V 0 50 5 60 30 70 ( C) (%) mbient temperature( C) mbient humidity(%) 34

PERFORMNCE DT COOL operation (30V) MSC-C0VB - E MSC-G0VB - E (Single) : MUX-8VB - E CPCITY :.4(kW) SHF : 0.74 INPUT : 760(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.8.58 0.56 608.70.5 0.56 638.59.45 0.56 669.50.40 0.56 699 0.94.9 0.44 638.8.4 0.44 676.74.0 0.44 69.64.6 0.44 7 8.8.69 0.60 608.70.6 0.60 638.59.56 0.60 669.50.50 0.60 699 0.94.4 0.48 638.8.35 0.48 676.74.3 0.48 69.64.7 0.48 7 3.06.0 0.36 66.95.06 0.36 703.88.04 0.36 7.76 0.99 0.36 75 3 8.8.80 0.64 608.70.73 0.64 638.59.66 0.64 669.50.60 0.64 699 3 0.94.53 0.5 638.8.47 0.5 676.74.4 0.5 69.64.37 0.5 7 3 3.06. 0.40 66.95.8 0.40 703.88.5 0.40 7.76.0 0.40 75 4 8.8.9 0.68 608.70.84 0.68 638.59.76 0.68 669.50.70 0.68 699 4 0.94.65 0.56 638.8.58 0.56 676.74.53 0.56 69.64.48 0.56 7 4 3.06.35 0.44 66.95.30 0.44 703.88.7 0.44 7.76. 0.44 75 4 4 3..03 0.3 69 3.0 0.99 0.3 730 3.0 0.97 0.3 75.93 0.94 0.3 790 5 8.8.03 0.7 608.70.94 0.7 638.59.87 0.7 669.50.80 0.7 699 5 0.94.76 0.60 638.8.69 0.60 676.74.64 0.60 69.64.58 0.60 7 5 3.06.47 0.48 66.95.4 0.48 703.88.38 0.48 7.76.3 0.48 75 5 4 3..6 0.36 69 3.0. 0.36 730 3.0.09 0.36 75.93.05 0.36 790 6 8.8.4 0.76 608.70.05 0.76 638.59.97 0.76 669.50.90 0.76 699 6 0.94.88 0.64 638.8.80 0.64 676.74.75 0.64 69.64.69 0.64 7 6 3.06.59 0.5 66.95.54 0.5 703.88.50 0.5 7.76.44 0.5 75 6 4 3..9 0.40 69 3.0.4 0.40 730 3.0. 0.40 75.93.7 0.40 790 6 6 3.3 0.93 0.8 730 3. 0.90 0.8 768 3.7 0.89 0.8 790 3.07 0.86 0.8 83 7 8.8.6 0.80 608.70.6 0.80 638.59.07 0.80 669.50.00 0.80 699 7 0.94.00 0.68 638.8.9 0.68 676.74.86 0.68 69.64.80 0.68 7 7 3.06.7 0.56 66.95.65 0.56 703.88.6 0.56 7.76.55 0.56 75 7 4 3..4 0.44 69 3.0.36 0.44 730 3.0.33 0.44 75.93.9 0.44 790 7 6 3.3.06 0.3 730 3..03 0.3 768 3.7.0 0.3 790 3.07 0.98 0.3 83 8 8.8.37 0.84 608.70.7 0.84 638.59.8 0.84 669.50.0 0.84 699 8 0.94. 0.7 638.8.03 0.7 676.74.97 0.7 69.64.90 0.7 7 8 3.06.84 0.60 66.95.77 0.60 703.88.73 0.60 7.76.66 0.60 75 8 4 3..54 0.48 69 3.0.49 0.48 730 3.0.45 0.48 75.93.4 0.48 790 8 6 3.3.9 0.36 730 3..6 0.36 768 3.7.4 0.36 790 3.07. 0.36 83 9 8.8.48 0.88 608.70.38 0.88 638.59.8 0.88 669.50.0 0.88 699 9 0.94.3 0.76 638.8.4 0.76 676.74.08 0.76 69.64.0 0.76 7 9 3.06.96 0.64 66.95.89 0.64 703.88.84 0.64 7.76.77 0.64 75 9 4 3..67 0.5 69 3.0.6 0.5 730 3.0.57 0.5 75.93.5 0.5 790 9 6 3.3.3 0.40 730 3..9 0.40 768 3.7.7 0.40 790 3.07.3 0.40 83 30 8.8.59 0.9 608.70.48 0.9 638.59.38 0.9 669.50.30 0.9 699 30 0.94.35 0.80 638.8.6 0.80 676.74.9 0.80 69.64. 0.80 7 30 3.06.08 0.68 66.95.0 0.68 703.88.96 0.68 7.76.88 0.68 75 30 4 3..80 0.56 69 3.0.73 0.56 730 3.0.69 0.56 75.93.64 0.56 790 30 6 3.3.46 0.44 730 3..4 0.44 768 3.7.39 0.44 790 3.07.35 0.44 83 3 8.8.7 0.96 608.70.59 0.96 638.59.49 0.96 669.50.40 0.96 699 3 0.94.47 0.84 638.8.37 0.84 676.74.30 0.84 69.64. 0.84 7 3 3.06.0 0.7 66.95.3 0.7 703.88.07 0.7 7.76.99 0.7 75 3 4 3..93 0.60 69 3.0.86 0.60 730 3.0.8 0.60 75.93.76 0.60 790 3 6 3.3.59 0.48 730 3..54 0.48 768 3.7.5 0.48 790 3.07.47 0.48 83 3 8.8.8.00 608.70.70.00 638.59.59.00 669.50.50.00 699 3 0.94.59 0.88 638.8.48 0.88 676.74.4 0.88 69.64.3 0.88 7 3 3.06.33 0.76 66.95.4 0.76 703.88.9 0.76 7.76.0 0.76 75 3 4 3..06 0.64 69 3.0.98 0.64 730 3.0.94 0.64 75.93.87 0.64 790 3 6 3.3.7 0.5 730 3..67 0.5 768 3.7.65 0.5 790 3.07.60 0.5 83 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 35

PERFORMNCE DT COOL operation (30V) MSC-C0VB - E MSC-G0VB - E (Single) : MUX-8VB - E CPCITY :.4(kW) SHF : 0.74 INPUT : 760(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.35.3 0.56 745.6. 0.56 790.08.6 0.56 806 0.47.09 0.44 775.30.0 0.44 83. 0.98 0.44 836 8.35.4 0.60 745.6.30 0.60 790.08.5 0.60 806 0.47.9 0.48 775.30. 0.48 83..07 0.48 836.6 0.94 0.36 806.45 0.88 0.36 85.36 0.85 0.36 866 3 8.35.5 0.64 745.6.38 0.64 790.08.33 0.64 806 3 0.47.9 0.5 775.30.0 0.5 83..5 0.5 836 3.6.05 0.40 806.45 0.98 0.40 85.36 0.95 0.40 866 4 8.35.60 0.68 745.6.47 0.68 790.08.4 0.68 806 4 0.47.38 0.56 775.30.9 0.56 83..4 0.56 836 4.6.5 0.44 806.45.08 0.44 85.36.04 0.44 866 4 4.76 0.88 0.3 836.59 0.83 0.3 874.5 0.8 0.3 893 5 8.35.69 0.7 745.6.56 0.7 790.08.49 0.7 806 5 0.47.48 0.60 775.30.38 0.60 83..33 0.60 836 5.6.6 0.48 806.45.8 0.48 85.36.3 0.48 866 5 4.76 0.99 0.36 836.59 0.93 0.36 874.5 0.9 0.36 893 6 8.35.79 0.76 745.6.64 0.76 790.08.58 0.76 806 6 0.47.58 0.64 775.30.47 0.64 83..4 0.64 836 6.6.36 0.5 806.45.7 0.5 85.36.3 0.5 866 6 4.76.0 0.40 836.59.04 0.40 874.5.0 0.40 893 6 6.90 0.8 0.8 866.74 0.77 0.8 904.65 0.74 0.8 93 7 8.35.88 0.80 745.6.73 0.80 790.08.66 0.80 806 7 0.47.68 0.68 775.30.57 0.68 83..5 0.68 836 7.6.46 0.56 806.45.37 0.56 85.36.3 0.56 866 7 4.76. 0.44 836.59.4 0.44 874.5. 0.44 893 7 6.90 0.93 0.3 866.74 0.88 0.3 904.65 0.85 0.3 93 8 8.35.98 0.84 745.6.8 0.84 790.08.74 0.84 806 8 0.47.78 0.7 775.30.66 0.7 83..60 0.7 836 8.6.57 0.60 806.45.47 0.60 85.36.4 0.60 866 8 4.76.3 0.48 836.59.4 0.48 874.5. 0.48 893 8 6.90.05 0.36 866.74 0.98 0.36 904.65 0.95 0.36 93 9 8.35.07 0.88 745.6.90 0.88 790.08.83 0.88 806 9 0.47.88 0.76 775.30.75 0.76 83..69 0.76 836 9.6.67 0.64 806.45.57 0.64 85.36.5 0.64 866 9 4.76.44 0.5 836.59.35 0.5 874.5.3 0.5 893 9 6.90.6 0.40 866.74.09 0.40 904.65.06 0.40 93 30 8.35.6 0.9 745.6.99 0.9 790.08.9 0.9 806 30 0.47.98 0.80 775.30.84 0.80 83..78 0.80 836 30.6.78 0.68 806.45.66 0.68 85.36.6 0.68 866 30 4.76.55 0.56 836.59.45 0.56 874.5.4 0.56 893 30 6.90.8 0.44 866.74.0 0.44 904.65.7 0.44 93 3 8.35.6 0.96 745.6.07 0.96 790.08.99 0.96 806 3 0.47.08 0.84 775.30.94 0.84 83..86 0.84 836 3.6.88 0.7 806.45.76 0.7 85.36.70 0.7 866 3 4.76.66 0.60 836.59.56 0.60 874.5.5 0.60 893 3 6.90.39 0.48 866.74.3 0.48 904.65.7 0.48 93 3 8.35.35.00 745.6.6.00 790.08.08.00 806 3 0.47.8 0.88 775.30.03 0.88 83..95 0.88 836 3.6.99 0.76 806.45.86 0.76 85.36.80 0.76 866 3 4.76.77 0.64 836.59.66 0.64 874.5.6 0.64 893 3 6.90.5 0.5 866.74.4 0.5 904.65.38 0.5 93 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 36

PERFORMNCE DT COOL operation (30V) MSC-C0VB - MSC-G0VB - (Single : Room B) : MUX-59VB - E CPCITY :.4(kW) SHF : 0.74 INPUT : 80(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.8.58 0.56 656.70.5 0.56 689.59.45 0.56 7.50.40 0.56 754 0.94.9 0.44 689.8.4 0.44 730.74.0 0.44 746.64.6 0.44 779 8.8.69 0.60 656.70.6 0.60 689.59.56 0.60 7.50.50 0.60 754 0.94.4 0.48 689.8.35 0.48 730.74.3 0.48 746.64.7 0.48 779 3.06.0 0.36 73.95.06 0.36 759.88.04 0.36 779.76 0.99 0.36 8 3 8.8.80 0.64 656.70.73 0.64 689.59.66 0.64 7.50.60 0.64 754 3 0.94.53 0.5 689.8.47 0.5 730.74.4 0.5 746.64.37 0.5 779 3 3.06. 0.40 73.95.8 0.40 759.88.5 0.40 779.76.0 0.40 8 4 8.8.9 0.68 656.70.84 0.68 689.59.76 0.68 7.50.70 0.68 754 4 0.94.65 0.56 689.8.58 0.56 730.74.53 0.56 746.64.48 0.56 779 4 3.06.35 0.44 73.95.30 0.44 759.88.7 0.44 779.76. 0.44 8 4 4 3..03 0.3 746 3.0 0.99 0.3 787 3.0 0.97 0.3 8.93 0.94 0.3 853 5 8.8.03 0.7 656.70.94 0.7 689.59.87 0.7 7.50.80 0.7 754 5 0.94.76 0.60 689.8.69 0.60 730.74.64 0.60 746.64.58 0.60 779 5 3.06.47 0.48 73.95.4 0.48 759.88.38 0.48 779.76.3 0.48 8 5 4 3..6 0.36 746 3.0. 0.36 787 3.0.09 0.36 8.93.05 0.36 853 6 8.8.4 0.76 656.70.05 0.76 689.59.97 0.76 7.50.90 0.76 754 6 0.94.88 0.64 689.8.80 0.64 730.74.75 0.64 746.64.69 0.64 779 6 3.06.59 0.5 73.95.54 0.5 759.88.50 0.5 779.76.44 0.5 8 6 4 3..9 0.40 746 3.0.4 0.40 787 3.0. 0.40 8.93.7 0.40 853 6 6 3.3 0.93 0.8 787 3. 0.90 0.8 88 3.7 0.89 0.8 853 3.07 0.86 0.8 877 7 8.8.6 0.80 656.70.6 0.80 689.59.07 0.80 7.50.00 0.80 754 7 0.94.00 0.68 689.8.9 0.68 730.74.86 0.68 746.64.80 0.68 779 7 3.06.7 0.56 73.95.65 0.56 759.88.6 0.56 779.76.55 0.56 8 7 4 3..4 0.44 746 3.0.36 0.44 787 3.0.33 0.44 8.93.9 0.44 853 7 6 3.3.06 0.3 787 3..03 0.3 88 3.7.0 0.3 853 3.07 0.98 0.3 877 8 8.8.37 0.84 656.70.7 0.84 689.59.8 0.84 7.50.0 0.84 754 8 0.94. 0.7 689.8.03 0.7 730.74.97 0.7 746.64.90 0.7 779 8 3.06.84 0.60 73.95.77 0.60 759.88.73 0.60 779.76.66 0.60 8 8 4 3..54 0.48 746 3.0.49 0.48 787 3.0.45 0.48 8.93.4 0.48 853 8 6 3.3.9 0.36 787 3..6 0.36 88 3.7.4 0.36 853 3.07. 0.36 877 9 8.8.48 0.88 656.70.38 0.88 689.59.8 0.88 7.50.0 0.88 754 9 0.94.3 0.76 689.8.4 0.76 730.74.08 0.76 746.64.0 0.76 779 9 3.06.96 0.64 73.95.89 0.64 759.88.84 0.64 779.76.77 0.64 8 9 4 3..67 0.5 746 3.0.6 0.5 787 3.0.57 0.5 8.93.5 0.5 853 9 6 3.3.3 0.40 787 3..9 0.40 88 3.7.7 0.40 853 3.07.3 0.40 877 30 8.8.59 0.9 656.70.48 0.9 689.59.38 0.9 7.50.30 0.9 754 30 0.94.35 0.80 689.8.6 0.80 730.74.9 0.80 746.64. 0.80 779 30 3.06.08 0.68 73.95.0 0.68 759.88.96 0.68 779.76.88 0.68 8 30 4 3..80 0.56 746 3.0.73 0.56 787 3.0.69 0.56 8.93.64 0.56 853 30 6 3.3.46 0.44 787 3..4 0.44 88 3.7.39 0.44 853 3.07.35 0.44 877 3 8.8.7 0.96 656.70.59 0.96 689.59.49 0.96 7.50.40 0.96 754 3 0.94.47 0.84 689.8.37 0.84 730.74.30 0.84 746.64. 0.84 779 3 3.06.0 0.7 73.95.3 0.7 759.88.07 0.7 779.76.99 0.7 8 3 4 3..93 0.60 746 3.0.86 0.60 787 3.0.8 0.60 8.93.76 0.60 853 3 6 3.3.59 0.48 787 3..54 0.48 88 3.7.5 0.48 853 3.07.47 0.48 877 3 8.8.8.00 656.70.70.00 689.59.59.00 7.50.50.00 754 3 0.94.59 0.88 689.8.48 0.88 730.74.4 0.88 746.64.3 0.88 779 3 3.06.33 0.76 73.95.4 0.76 759.88.9 0.76 779.76.0 0.76 8 3 4 3..06 0.64 746 3.0.98 0.64 787 3.0.94 0.64 8.93.87 0.64 853 3 6 3.3.7 0.5 787 3..67 0.5 88 3.7.65 0.5 853 3.07.60 0.5 877 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 37

PERFORMNCE DT COOL operation (30V) MSC-C0VB - MSC-G0VB - (Single : Room B) : MUX-59VB - E CPCITY :.4(kW) SHF : 0.74 INPUT : 80(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.35.3 0.56 804.6. 0.56 853.08.6 0.56 869 0.47.09 0.44 836.30.0 0.44 877. 0.98 0.44 90 8.35.4 0.60 804.6.30 0.60 853.08.5 0.60 869 0.47.9 0.48 836.30. 0.48 877..07 0.48 90.6 0.94 0.36 869.45 0.88 0.36 98.36 0.85 0.36 935 3 8.35.5 0.64 804.6.38 0.64 853.08.33 0.64 869 3 0.47.9 0.5 836.30.0 0.5 877..5 0.5 90 3.6.05 0.40 869.45 0.98 0.40 98.36 0.95 0.40 935 4 8.35.60 0.68 804.6.47 0.68 853.08.4 0.68 869 4 0.47.38 0.56 836.30.9 0.56 877..4 0.56 90 4.6.5 0.44 869.45.08 0.44 98.36.04 0.44 935 4 4.76 0.88 0.3 90.59 0.83 0.3 943.5 0.8 0.3 964 5 8.35.69 0.7 804.6.56 0.7 853.08.49 0.7 869 5 0.47.48 0.60 836.30.38 0.60 877..33 0.60 90 5.6.6 0.48 869.45.8 0.48 98.36.3 0.48 935 5 4.76 0.99 0.36 90.59 0.93 0.36 943.5 0.9 0.36 964 6 8.35.79 0.76 804.6.64 0.76 853.08.58 0.76 869 6 0.47.58 0.64 836.30.47 0.64 877..4 0.64 90 6.6.36 0.5 869.45.7 0.5 98.36.3 0.5 935 6 4.76.0 0.40 90.59.04 0.40 943.5.0 0.40 964 6 6.90 0.8 0.8 935.74 0.77 0.8 976.65 0.74 0.8 996 7 8.35.88 0.80 804.6.73 0.80 853.08.66 0.80 869 7 0.47.68 0.68 836.30.57 0.68 877..5 0.68 90 7.6.46 0.56 869.45.37 0.56 98.36.3 0.56 935 7 4.76. 0.44 90.59.4 0.44 943.5. 0.44 964 7 6.90 0.93 0.3 935.74 0.88 0.3 976.65 0.85 0.3 996 8 8.35.98 0.84 804.6.8 0.84 853.08.74 0.84 869 8 0.47.78 0.7 836.30.66 0.7 877..60 0.7 90 8.6.57 0.60 869.45.47 0.60 98.36.4 0.60 935 8 4.76.3 0.48 90.59.4 0.48 943.5. 0.48 964 8 6.90.05 0.36 935.74 0.98 0.36 976.65 0.95 0.36 996 9 8.35.07 0.88 804.6.90 0.88 853.08.83 0.88 869 9 0.47.88 0.76 836.30.75 0.76 877..69 0.76 90 9.6.67 0.64 869.45.57 0.64 98.36.5 0.64 935 9 4.76.44 0.5 90.59.35 0.5 943.5.3 0.5 964 9 6.90.6 0.40 935.74.09 0.40 976.65.06 0.40 996 30 8.35.6 0.9 804.6.99 0.9 853.08.9 0.9 869 30 0.47.98 0.80 836.30.84 0.80 877..78 0.80 90 30.6.78 0.68 869.45.66 0.68 98.36.6 0.68 935 30 4.76.55 0.56 90.59.45 0.56 943.5.4 0.56 964 30 6.90.8 0.44 935.74.0 0.44 976.65.7 0.44 996 3 8.35.6 0.96 804.6.07 0.96 853.08.99 0.96 869 3 0.47.08 0.84 836.30.94 0.84 877..86 0.84 90 3.6.88 0.7 869.45.76 0.7 98.36.70 0.7 935 3 4.76.66 0.60 90.59.56 0.60 943.5.5 0.60 964 3 6.90.39 0.48 935.74.3 0.48 976.65.7 0.48 996 3 8.35.35.00 804.6.6.00 853.08.08.00 869 3 0.47.8 0.88 836.30.03 0.88 877..95 0.88 90 3.6.99 0.76 869.45.86 0.76 98.36.80 0.76 935 3 4.76.77 0.64 90.59.66 0.64 943.5.6 0.64 964 3 6.90.5 0.5 935.74.4 0.5 976.65.38 0.5 996 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 38

PERFORMNCE DT COOL operation (30V) MSC-C35VB - MSC-G35VB - (Single : Room ) : MUX-59VB - E CPCITY : 3.5(kW) SHF : 0.73 INPUT : 30(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 4..5 0.55 056 3.94.5 0.55 09 3.78.07 0.55 6 3.64.99 0.55 4 0 4.9.83 0.43 09 4..76 0.43 75 3.99.70 0.43 0 3.85.64 0.43 54 8 4..4 0.59 056 3.94.3 0.59 09 3.78. 0.59 6 3.64.4 0.59 4 0 4.9.00 0.47 09 4..9 0.47 75 3.99.86 0.47 0 3.85.80 0.47 54 4.46.55 0.35 48 4.3.49 0.35 4.0.46 0.35 54 4.03.40 0.35 307 3 8 4..58 0.63 056 3.94.47 0.63 09 3.78.37 0.63 6 3.64.8 0.63 4 3 0 4.9.7 0.5 09 4..09 0.5 75 3.99.0 0.5 0 3.85.95 0.5 54 3 4.46.73 0.39 48 4.3.67 0.39 4.0.63 0.39 54 4.03.56 0.39 307 4 8 4..74 0.67 056 3.94.63 0.67 09 3.78.5 0.67 6 3.64.43 0.67 4 4 0 4.9.35 0.55 09 4..5 0.55 75 3.99.8 0.55 0 3.85. 0.55 54 4 4.46.9 0.43 48 4.3.84 0.43 4.0.79 0.43 54 4.03.7 0.43 307 4 4 4.69.44 0.3 0 4.5.39 0.3 67 4.4.35 0.3 307 4.7.3 0.3 373 5 8 4..9 0.7 056 3.94.78 0.7 09 3.78.67 0.7 6 3.64.57 0.7 4 5 0 4.9.5 0.59 09 4..4 0.59 75 3.99.34 0.59 0 3.85.6 0.59 54 5 4.46.08 0.47 48 4.3.0 0.47 4.0.96 0.47 54 4.03.88 0.47 307 5 4 4.69.63 0.35 0 4.5.57 0.35 67 4.4.53 0.35 307 4.7.48 0.35 373 6 8 4. 3.07 0.75 056 3.94.94 0.75 09 3.78.8 0.75 6 3.64.7 0.75 4 6 0 4.9.69 0.63 09 4..58 0.63 75 3.99.50 0.63 0 3.85.4 0.63 54 6 4.46.6 0.5 48 4.3.8 0.5 4.0.3 0.5 54 4.03.04 0.5 307 6 4 4.69.8 0.39 0 4.5.75 0.39 67 4.4.7 0.39 307 4.7.65 0.39 373 6 6 4.83.9 0.7 67 4.69.5 0.7 333 4.6.3 0.7 373 4.48.0 0.7 4 7 8 4. 3.4 0.79 056 3.94 3.0 0.79 09 3.78.97 0.79 6 3.64.86 0.79 4 7 0 4.9.86 0.67 09 4..74 0.67 75 3.99.66 0.67 0 3.85.57 0.67 54 7 4.46.44 0.55 48 4.3.35 0.55 4.0.30 0.55 54 4.03.0 0.55 307 7 4 4.69.00 0.43 0 4.5.93 0.43 67 4.4.88 0.43 307 4.7.8 0.43 373 7 6 4.83.48 0.3 67 4.69.44 0.3 333 4.6.4 0.3 373 4.48.38 0.3 4 8 8 4. 3.40 0.83 056 3.94 3.6 0.83 09 3.78 3.3 0.83 6 3.64 3.0 0.83 4 8 0 4.9 3.03 0.7 09 4..9 0.7 75 3.99.8 0.7 0 3.85.7 0.7 54 8 4.46.6 0.59 48 4.3.53 0.59 4.0.47 0.59 54 4.03.36 0.59 307 8 4 4.69.9 0.47 0 4.5. 0.47 67 4.4.06 0.47 307 4.7.99 0.47 373 8 6 4.83.68 0.35 67 4.69.63 0.35 333 4.6.60 0.35 373 4.48.55 0.35 4 9 8 4. 3.57 0.87 056 3.94 3.4 0.87 09 3.78 3.8 0.87 6 3.64 3.6 0.87 4 9 0 4.9 3.0 0.75 09 4. 3.07 0.75 75 3.99.98 0.75 0 3.85.88 0.75 54 9 4.46.80 0.63 48 4.3.70 0.63 4.0.63 0.63 54 4.03.5 0.63 307 9 4 4.69.38 0.5 0 4.5.9 0.5 67 4.4.4 0.5 307 4.7.6 0.5 373 9 6 4.83.87 0.39 67 4.69.8 0.39 333 4.6.79 0.39 373 4.48.73 0.39 4 30 8 4. 3.73 0.9 056 3.94 3.57 0.9 09 3.78 3.43 0.9 6 3.64 3.30 0.9 4 30 0 4.9 3.37 0.79 09 4. 3.4 0.79 75 3.99 3.4 0.79 0 3.85 3.03 0.79 54 30 4.46.98 0.67 48 4.3.87 0.67 4.0.80 0.67 54 4.03.68 0.67 307 30 4 4.69.57 0.55 0 4.5.47 0.55 67 4.4.4 0.55 307 4.7.34 0.55 373 30 6 4.83.06 0.43 67 4.69.00 0.43 333 4.6.97 0.43 373 4.48.9 0.43 4 3 8 4. 3.89 0.95 056 3.94 3.73 0.95 09 3.78 3.58 0.95 6 3.64 3.45 0.95 4 3 0 4.9 3.55 0.83 09 4. 3.40 0.83 75 3.99 3.30 0.83 0 3.85 3.8 0.83 54 3 4.46 3.5 0.7 48 4.3 3.04 0.7 4.0.97 0.7 54 4.03.85 0.7 307 3 4 4.69.75 0.59 0 4.5.65 0.59 67 4.4.59 0.59 307 4.7.5 0.59 373 3 6 4.83.6 0.47 67 4.69.9 0.47 333 4.6.6 0.47 373 4.48.09 0.47 4 3 8 4. 4.06 0.99 056 3.94 3.89 0.99 09 3.78 3.73 0.99 6 3.64 3.59 0.99 4 3 0 4.9 3.7 0.87 09 4. 3.57 0.87 75 3.99 3.46 0.87 0 3.85 3.34 0.87 54 3 4.46 3.33 0.75 48 4.3 3. 0.75 4.0 3.4 0.75 54 4.03 3.0 0.75 307 3 4 4.69.94 0.63 0 4.5.83 0.63 67 4.4.77 0.63 307 4.7.68 0.63 373 3 6 4.83.45 0.5 67 4.69.38 0.5 333 4.6.34 0.5 373 4.48.7 0.5 4 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 39

PERFORMNCE DT COOL operation (30V) MSC-C35VB - MSC-G35VB - (Single : Room ) : MUX-59VB - E CPCITY : 3.5(kW) SHF : 0.73 INPUT : 30(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.43.88 0.55 94 3.5.7 0.55 373 3.03.66 0.55 399 0 3.6.54 0.43 346 3.36.43 0.43 4 3.4.38 0.43 45 8 3.43.0 0.59 94 3.5.85 0.59 373 3.03.78 0.59 399 0 3.6.68 0.47 346 3.36.57 0.47 4 3.4.5 0.47 45 3.8.3 0.35 399 3.57.4 0.35 478 3.45.0 0.35 505 3 8 3.43.5 0.63 94 3.5.98 0.63 373 3.03.90 0.63 399 3 0 3.6.83 0.5 346 3.36.70 0.5 4 3.4.64 0.5 45 3 3.8.48 0.39 399 3.57.38 0.39 478 3.45.33 0.39 505 4 8 3.43.9 0.67 94 3.5.0 0.67 373 3.03.0 0.67 399 4 0 3.6.97 0.55 346 3.36.84 0.55 4 3.4.77 0.55 45 4 3.8.63 0.43 399 3.57.5 0.43 478 3.45.47 0.43 505 4 4 4.03.4 0.3 45 3.78.6 0.3 58 3.68.3 0.3 55 5 8 3.43.43 0.7 94 3.5.3 0.7 373 3.03.4 0.7 399 5 0 3.6. 0.59 346 3.36.97 0.59 4 3.4.90 0.59 45 5 3.8.78 0.47 399 3.57.67 0.47 478 3.45.6 0.47 505 5 4 4.03.40 0.35 45 3.78.3 0.35 58 3.68.8 0.35 55 6 8 3.43.56 0.75 94 3.5.35 0.75 373 3.03.6 0.75 399 6 0 3.6.6 0.63 346 3.36. 0.63 4 3.4.03 0.63 45 6 3.8.93 0.5 399 3.57.8 0.5 478 3.45.75 0.5 505 6 4 4.03.56 0.39 45 3.78.46 0.39 58 3.68.4 0.39 55 6 6 4.4.3 0.7 505 3.99.07 0.7 57 3.87.03 0.7 604 7 8 3.43.70 0.79 94 3.5.48 0.79 373 3.03.38 0.79 399 7 0 3.6.40 0.67 346 3.36.4 0.67 4 3.4.6 0.67 45 7 3.8.09 0.55 399 3.57.95 0.55 478 3.45.89 0.55 505 7 4 4.03.7 0.43 45 3.78.6 0.43 58 3.68.57 0.43 55 7 6 4.4.30 0.3 505 3.99. 0.3 57 3.87.9 0.3 604 8 8 3.43.84 0.83 94 3.5.6 0.83 373 3.03.50 0.83 399 8 0 3.6.55 0.7 346 3.36.38 0.7 4 3.4.9 0.7 45 8 3.8.4 0.59 399 3.57.0 0.59 478 3.45.0 0.59 505 8 4 4.03.88 0.47 45 3.78.77 0.47 58 3.68.7 0.47 55 8 6 4.4.47 0.35 505 3.99.38 0.35 57 3.87.34 0.35 604 9 8 3.43.97 0.87 94 3.5.73 0.87 373 3.03.6 0.87 399 9 0 3.6.69 0.75 346 3.36.5 0.75 4 3.4.4 0.75 45 9 3.8.39 0.63 399 3.57.4 0.63 478 3.45.6 0.63 505 9 4 4.03.04 0.5 45 3.78.9 0.5 58 3.68.86 0.5 55 9 6 4.4.64 0.39 505 3.99.54 0.39 57 3.87.50 0.39 604 30 8 3.43 3. 0.9 94 3.5.86 0.9 373 3.03.75 0.9 399 30 0 3.6.84 0.79 346 3.36.64 0.79 4 3.4.55 0.79 45 30 3.8.54 0.67 399 3.57.38 0.67 478 3.45.30 0.67 505 30 4 4.03.0 0.55 45 3.78.07 0.55 58 3.68.0 0.55 55 30 6 4.4.8 0.43 505 3.99.70 0.43 57 3.87.65 0.43 604 3 8 3.43 3.5 0.95 94 3.5.98 0.95 373 3.03.87 0.95 399 3 0 3.6.98 0.83 346 3.36.78 0.83 4 3.4.68 0.83 45 3 3.8.70 0.7 399 3.57.5 0.7 478 3.45.44 0.7 505 3 4 4.03.36 0.59 45 3.78. 0.59 58 3.68.6 0.59 55 3 6 4.4.98 0.47 505 3.99.86 0.47 57 3.87.8 0.47 604 3 8 3.43 3.39 0.99 94 3.5 3. 0.99 373 3.03.99 0.99 399 3 0 3.6 3.3 0.87 346 3.36.9 0.87 4 3.4.8 0.87 45 3 3.8.85 0.75 399 3.57.67 0.75 478 3.45.58 0.75 505 3 4 4.03.5 0.63 45 3.78.37 0.63 58 3.68.30 0.63 55 3 6 4.4.5 0.5 505 3.99.0 0.5 57 3.87.96 0.5 604 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 40

PERFORMNCE DT COOL operation (30V) MSC-C5VB - MSC-G5VB - (Single : Room ) : MUX-360VB - E CPCITY :.6(kW) SHF : 0.75 INPUT : 850(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.06.74 0.57 680.93.67 0.57 74.8.60 0.57 748.70.54 0.57 78 0 3.9.43 0.45 74 3.06.37 0.45 757.96.33 0.45 774.86.9 0.45 808 8 3.06.86 0.6 680.93.78 0.6 74.8.7 0.6 748.70.65 0.6 78 0 3.9.56 0.49 74 3.06.50 0.49 757.96.45 0.49 774.86.40 0.49 808 3.3.3 0.37 740 3.0.8 0.37 786 3..5 0.37 808.99. 0.37 84 3 8 3.06.99 0.65 680.93.90 0.65 74.8.83 0.65 748.70.76 0.65 78 3 0 3.9.69 0.53 74 3.06.6 0.53 757.96.57 0.53 774.86.5 0.53 808 3 3.3.36 0.4 740 3.0.3 0.4 786 3..8 0.4 808.99.3 0.4 84 4 8 3.06. 0.69 680.93.0 0.69 74.8.94 0.69 748.70.87 0.69 78 4 0 3.9.8 0.57 74 3.06.74 0.57 757.96.69 0.57 774.86.63 0.57 808 4 3.3.49 0.45 740 3.0.44 0.45 786 3..40 0.45 808.99.35 0.45 84 4 4 3.48.5 0.33 774 3.35. 0.33 86 3.8.08 0.33 84 3.7.05 0.33 884 5 8 3.06.3 0.73 680.93.4 0.73 74.8.05 0.73 748.70.97 0.73 78 5 0 3.9.94 0.6 74 3.06.86 0.6 757.96.8 0.6 774.86.74 0.6 808 5 3.3.6 0.49 740 3.0.57 0.49 786 3..53 0.49 808.99.47 0.49 84 5 4 3.48.9 0.37 774 3.35.4 0.37 86 3.8. 0.37 84 3.7.7 0.37 884 6 8 3.06.35 0.77 680.93.5 0.77 74.8.6 0.77 748.70.08 0.77 78 6 0 3.9.07 0.65 74 3.06.99 0.65 757.96.93 0.65 774.86.86 0.65 808 6 3.3.76 0.53 740 3.0.69 0.53 786 3..65 0.53 808.99.58 0.53 84 6 4 3.48.43 0.4 774 3.35.38 0.4 86 3.8.34 0.4 84 3.7.30 0.4 884 6 6 3.59.04 0.9 86 3.48.0 0.9 859 3.43.00 0.9 884 3.33 0.97 0.9 90 7 8 3.06.47 0.8 680.93.37 0.8 74.8.7 0.8 748.70.9 0.8 78 7 0 3.9.0 0.69 74 3.06. 0.69 757.96.05 0.69 774.86.97 0.69 808 7 3.3.89 0.57 740 3.0.8 0.57 786 3..78 0.57 808.99.70 0.57 84 7 4 3.48.57 0.45 774 3.35.5 0.45 86 3.8.47 0.45 84 3.7.43 0.45 884 7 6 3.59.8 0.33 86 3.48.5 0.33 859 3.43.3 0.33 884 3.33.0 0.33 90 8 8 3.06.60 0.85 680.93.49 0.85 74.8.39 0.85 748.70.30 0.85 78 8 0 3.9.33 0.73 74 3.06.3 0.73 757.96.6 0.73 774.86.09 0.73 808 8 3.3.0 0.6 740 3.0.95 0.6 786 3..90 0.6 808.99.8 0.6 84 8 4 3.48.7 0.49 774 3.35.64 0.49 86 3.8.6 0.49 84 3.7.55 0.49 884 8 6 3.59.33 0.37 86 3.48.9 0.37 859 3.43.7 0.37 884 3.33.3 0.37 90 9 8 3.06.7 0.89 680.93.60 0.89 74.8.50 0.89 748.70.4 0.89 78 9 0 3.9.45 0.77 74 3.06.35 0.77 757.96.8 0.77 774.86.0 0.77 808 9 3.3.5 0.65 740 3.0.08 0.65 786 3..03 0.65 808.99.94 0.65 84 9 4 3.48.85 0.53 774 3.35.78 0.53 86 3.8.74 0.53 84 3.7.68 0.53 884 9 6 3.59.47 0.4 86 3.48.43 0.4 859 3.43.4 0.4 884 3.33.36 0.4 90 30 8 3.06.84 0.93 680.93.7 0.93 74.8.6 0.93 748.70.5 0.93 78 30 0 3.9.58 0.8 74 3.06.47 0.8 757.96.40 0.8 774.86.3 0.8 808 30 3.3.9 0.69 740 3.0. 0.69 786 3..5 0.69 808.99.06 0.69 84 30 4 3.48.99 0.57 774 3.35.9 0.57 86 3.8.87 0.57 84 3.7.8 0.57 884 30 6 3.59.6 0.45 86 3.48.57 0.45 859 3.43.54 0.45 884 3.33.50 0.45 90 3 8 3.06.96 0.97 680.93.84 0.97 74.8.7 0.97 748.70.6 0.97 78 3 0 3.9.7 0.85 74 3.06.60 0.85 757.96.5 0.85 774.86.43 0.85 808 3 3.3.4 0.73 740 3.0.33 0.73 786 3..8 0.73 808.99.8 0.73 84 3 4 3.48.3 0.6 774 3.35.05 0.6 86 3.8.00 0.6 84 3.7.93 0.6 884 3 6 3.59.76 0.49 86 3.48.7 0.49 859 3.43.68 0.49 884 3.33.63 0.49 90 3 8 3.06 3.09.0 680.93.95.0 74.8.84.0 748.70.73.0 78 3 0 3.9.83 0.89 74 3.06.7 0.89 757.96.64 0.89 774.86.55 0.89 808 3 3.3.55 0.77 740 3.0.46 0.77 786 3..40 0.77 808.99.30 0.77 84 3 4 3.48.6 0.65 774 3.35.8 0.65 86 3.8.3 0.65 84 3.7.06 0.65 884 3 6 3.59.90 0.53 86 3.48.85 0.53 859 3.43.8 0.53 884 3.33.76 0.53 90 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 4

PERFORMNCE DT COOL operation (30V) MSC-C5VB - MSC-G5VB - (Single : Room ) : MUX-360VB - E CPCITY :.6(kW) SHF : 0.75 INPUT : 850(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.55.45 0.57 833.34.33 0.57 884.5.8 0.57 90 0.68. 0.45 867.50. 0.45 90.4.08 0.45 935 8.55.55 0.6 833.34.43 0.6 884.5.37 0.6 90 0.68.3 0.49 867.50. 0.49 90.4.8 0.49 935.83.05 0.37 90.65 0.98 0.37 95.56 0.95 0.37 969 3 8.55.66 0.65 833.34.5 0.65 884.5.46 0.65 90 3 0.68.4 0.53 867.50.3 0.53 90.4.7 0.53 935 3.83.6 0.4 90.65.09 0.4 95.56.05 0.4 969 4 8.55.76 0.69 833.34.6 0.69 884.5.55 0.69 90 4 0.68.53 0.57 867.50.4 0.57 90.4.37 0.57 935 4.83.8 0.45 90.65.9 0.45 95.56.5 0.45 969 4 4.99 0.99 0.33 935.8 0.93 0.33 978.73 0.90 0.33 999 5 8.55.86 0.73 833.34.7 0.73 884.5.64 0.73 90 5 0.68.63 0.6 867.50.5 0.6 90.4.47 0.6 935 5.83.39 0.49 90.65.30 0.49 95.56.5 0.49 969 5 4.99. 0.37 935.8.04 0.37 978.73.0 0.37 999 6 8.55.96 0.77 833.34.80 0.77 884.5.73 0.77 90 6 0.68.74 0.65 867.50.6 0.65 90.4.56 0.65 935 6.83.50 0.53 90.65.4 0.53 95.56.36 0.53 969 6 4.99.3 0.4 935.8.5 0.4 978.73. 0.4 999 6 6 3.5 0.9 0.9 969.96 0.86 0.9 0.87 0.83 0.9 033 7 8.55.06 0.8 833.34.90 0.8 884.5.8 0.8 90 7 0.68.85 0.69 867.50.7 0.69 90.4.66 0.69 935 7.83.6 0.57 90.65.5 0.57 95.56.46 0.57 969 7 4.99.35 0.45 935.8.6 0.45 978.73.3 0.45 999 7 6 3.5.04 0.33 969.96 0.98 0.33 0.87 0.95 0.33 033 8 8.55.7 0.85 833.34.99 0.85 884.5.9 0.85 90 8 0.68.95 0.73 867.50.8 0.73 90.4.76 0.73 935 8.83.73 0.6 90.65.6 0.6 95.56.56 0.6 969 8 4.99.47 0.49 935.8.38 0.49 978.73.34 0.49 999 8 6 3.5.6 0.37 969.96.0 0.37 0.87.06 0.37 033 9 8.55.7 0.89 833.34.08 0.89 884.5.00 0.89 90 9 0.68.06 0.77 867.50.9 0.77 90.4.85 0.77 935 9.83.84 0.65 90.65.7 0.65 95.56.66 0.65 969 9 4.99.58 0.53 935.8.49 0.53 978.73.45 0.53 999 9 6 3.5.9 0.4 969.96. 0.4 0.87.8 0.4 033 30 8.55.37 0.93 833.34.8 0.93 884.5.09 0.93 90 30 0.68.7 0.8 867.50.0 0.8 90.4.95 0.8 935 30.83.96 0.69 90.65.83 0.69 95.56.77 0.69 969 30 4.99.70 0.57 935.8.60 0.57 978.73.56 0.57 999 30 6 3.5.4 0.45 969.96.33 0.45 0.87.9 0.45 033 3 8.55.47 0.97 833.34.7 0.97 884.5.8 0.97 90 3 0.68.8 0.85 867.50. 0.85 90.4.04 0.85 935 3.83.07 0.73 90.65.94 0.73 95.56.87 0.73 969 3 4.99.8 0.6 935.8.7 0.6 978.73.67 0.6 999 3 6 3.5.54 0.49 969.96.45 0.49 0.87.4 0.49 033 3 8.55.57.0 833.34.36.0 884.5.7.0 90 3 0.68.38 0.89 867.50. 0.89 90.4.4 0.89 935 3.83.8 0.77 90.65.04 0.77 95.56.97 0.77 969 3 4.99.94 0.65 935.8.83 0.65 978.73.77 0.65 999 3 6 3.5.67 0.53 969.96.57 0.53 0.87.5 0.53 033 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 4

PERFORMNCE DT COOL operation (30V) MSC-C5VB - MSC-G5VB - (Single : Room B) : MUX-360VB - E CPCITY :.9(kW) SHF : 0.7 INPUT : 0(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.4.8 0.53 888 3.6.74 0.53 93 3.3.67 0.53 977 3.0.6 0.53 0 0 3.55.47 0.4 93 3.4.4 0.4 988 3.3.37 0.4 00 3.9.3 0.4 055 8 3.4.95 0.57 888 3.6.87 0.57 93 3.3.79 0.57 977 3.0.73 0.57 0 0 3.55.6 0.45 93 3.4.54 0.45 988 3.3.50 0.45 00 3.9.45 0.45 055 3.70.3 0.33 966 3.57.9 0.33 07 3.48.6 0.33 055 3.34. 0.33 099 3 8 3.4.09 0.6 888 3.6.00 0.6 93 3.3.9 0.6 977 3.0.85 0.6 0 3 0 3.55.75 0.49 93 3.4.68 0.49 988 3.3.63 0.49 00 3.9.57 0.49 055 3 3.70.38 0.37 966 3.57.33 0.37 07 3.48.30 0.37 055 3.34.4 0.37 099 4 8 3.4.3 0.65 888 3.6.3 0.65 93 3.3.05 0.65 977 3.0.97 0.65 0 4 0 3.55.89 0.53 93 3.4.8 0.53 988 3.3.76 0.53 00 3.9.70 0.53 055 4 3.70.53 0.4 966 3.57.47 0.4 07 3.48.44 0.4 055 3.34.38 0.4 099 4 4 3.89.4 0.9 00 3.74.0 0.9 066 3.65.07 0.9 099 3.54.04 0.9 54 5 8 3.4.36 0.69 888 3.6.6 0.69 93 3.3.7 0.69 977 3.0.09 0.69 0 5 0 3.55.04 0.57 93 3.4.95 0.57 988 3.3.89 0.57 00 3.9.83 0.57 055 5 3.70.67 0.45 966 3.57.6 0.45 07 3.48.58 0.45 055 3.34.5 0.45 099 5 4 3.89.9 0.33 00 3.74.5 0.33 066 3.65. 0.33 099 3.54.8 0.33 54 6 8 3.4.50 0.73 888 3.6.39 0.73 93 3.3.30 0.73 977 3.0. 0.73 0 6 0 3.55.8 0.6 93 3.4.09 0.6 988 3.3.03 0.6 00 3.9.96 0.6 055 6 3.70.8 0.49 966 3.57.76 0.49 07 3.48.7 0.49 055 3.34.64 0.49 099 6 4 3.89.45 0.37 00 3.74.40 0.37 066 3.65.36 0.37 099 3.54.3 0.37 54 6 6 4.00.0 0.5 066 3.89 0.98 0.5 3.83 0.97 0.5 54 3.7 0.94 0.5 88 7 8 3.4.63 0.77 888 3.6.5 0.77 93 3.3.4 0.77 977 3.0.33 0.77 0 7 0 3.55.3 0.65 93 3.4.3 0.65 988 3.3.6 0.65 00 3.9.08 0.65 055 7 3.70.97 0.53 966 3.57.90 0.53 07 3.48.85 0.53 055 3.34.78 0.53 099 7 4 3.89.60 0.4 00 3.74.55 0.4 066 3.65.5 0.4 099 3.54.46 0.4 54 7 6 4.00.7 0.9 066 3.89.4 0.9 3.83. 0.9 54 3.7.09 0.9 88 8 8 3.4.77 0.8 888 3.6.65 0.8 93 3.3.55 0.8 977 3.0.45 0.8 0 8 0 3.55.46 0.69 93 3.4.36 0.69 988 3.3.9 0.69 00 3.9. 0.69 055 8 3.70. 0.57 966 3.57.04 0.57 07 3.48.99 0.57 055 3.34.9 0.57 099 8 4 3.89.76 0.45 00 3.74.69 0.45 066 3.65.66 0.45 099 3.54.60 0.45 54 8 6 4.00.33 0.33 066 3.89.9 0.33 3.83.7 0.33 54 3.7.4 0.33 88 9 8 3.4.9 0.85 888 3.6.78 0.85 93 3.3.67 0.85 977 3.0.57 0.85 0 9 0 3.55.60 0.73 93 3.4.50 0.73 988 3.3.4 0.73 00 3.9.34 0.73 055 9 3.70.7 0.6 966 3.57.9 0.6 07 3.48.3 0.6 055 3.34.04 0.6 099 9 4 3.89.9 0.49 00 3.74.84 0.49 066 3.65.80 0.49 099 3.54.74 0.49 54 9 6 4.00.49 0.37 066 3.89.45 0.37 3.83.43 0.37 54 3.7.38 0.37 88 30 8 3.4 3.04 0.89 888 3.6.9 0.89 93 3.3.80 0.89 977 3.0.69 0.89 0 30 0 3.55.75 0.77 93 3.4.63 0.77 988 3.3.56 0.77 00 3.9.47 0.77 055 30 3.70.4 0.65 966 3.57.33 0.65 07 3.48.7 0.65 055 3.34.8 0.65 099 30 4 3.89.07 0.53 00 3.74.99 0.53 066 3.65.95 0.53 099 3.54.89 0.53 54 30 6 4.00.65 0.4 066 3.89.60 0.4 3.83.58 0.4 54 3.7.53 0.4 88 3 8 3.4 3.8 0.93 888 3.6 3.04 0.93 93 3.3.9 0.93 977 3.0.8 0.93 0 3 0 3.55.89 0.8 93 3.4.77 0.8 988 3.3.69 0.8 00 3.9.59 0.8 055 3 3.70.56 0.69 966 3.57.47 0.69 07 3.48.4 0.69 055 3.34.3 0.69 099 3 4 3.89.3 0.57 00 3.74.4 0.57 066 3.65.09 0.57 099 3.54.03 0.57 54 3 6 4.00.8 0.45 066 3.89.76 0.45 3.83.73 0.45 54 3.7.68 0.45 88 3 8 3.4 3.3 0.97 888 3.6 3.7 0.97 93 3.3 3.05 0.97 977 3.0.93 0.97 0 3 0 3.55 3.03 0.85 93 3.4.9 0.85 988 3.3.8 0.85 00 3.9.7 0.85 055 3 3.70.7 0.73 966 3.57.6 0.73 07 3.48.55 0.73 055 3.34.44 0.73 099 3 4 3.89.38 0.6 00 3.74.9 0.6 066 3.65.4 0.6 099 3.54.7 0.6 54 3 6 4.00.97 0.49 066 3.89.9 0.49 3.83.89 0.49 54 3.7.83 0.49 88 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 43

PERFORMNCE DT COOL operation (30V) MSC-C5VB - MSC-G5VB - (Single : Room B) : MUX-360VB - E CPCITY :.9(kW) SHF : 0.7 INPUT : 0(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.84.5 0.53 088.6.39 0.53 54.5.34 0.53 77 0.99.3 0.4 3.78.5 0.4 88.68. 0.4 8.84.63 0.57 088.6.50 0.57 54.5.44 0.57 77 0.99.35 0.45 3.78.6 0.45 88.68. 0.45 3.6.05 0.33 77.96 0.99 0.33 43.86 0.95 0.33 65 3 8.84.74 0.6 088.6.60 0.6 54.5.54 0.6 77 3 0.99.47 0.49 3.78.37 0.49 88.68.3 0.49 3 3.6.8 0.37 77.96.0 0.37 43.86.07 0.37 65 4 8.84.86 0.65 088.6.70 0.65 54.5.64 0.65 77 4 0.99.59 0.53 3.78.48 0.53 88.68.43 0.53 4 3.6.3 0.4 77.96. 0.4 43.86.8 0.4 65 4 4 3.34 0.98 0.9 3.3 0.9 0.9 77 3.05 0.89 0.9 304 5 8.84.97 0.69 088.6.8 0.69 54.5.74 0.69 77 5 0.99.7 0.57 3.78.60 0.57 88.68.54 0.57 5 3.6.43 0.45 77.96.34 0.45 43.86.9 0.45 65 5 4 3.34. 0.33 3.3.04 0.33 77 3.05.0 0.33 304 6 8.84.08 0.73 088.6.9 0.73 54.5.84 0.73 77 6 0.99.83 0.6 3.78.7 0.6 88.68.64 0.6 6 3.6.56 0.49 77.96.46 0.49 43.86.4 0.49 65 6 4 3.34.4 0.37 3.3.7 0.37 77 3.05.4 0.37 304 6 6 3.5 0.89 0.5 65 3.3 0.84 0.5 3 3.0 0.8 0.5 349 7 8.84.0 0.77 088.6.0 0.77 54.5.94 0.77 77 7 0.99.95 0.65 3.78.8 0.65 88.68.75 0.65 7 3.6.68 0.53 77.96.58 0.53 43.86.5 0.53 65 7 4 3.34.38 0.4 3.3.9 0.4 77 3.05.6 0.4 304 7 6 3.5.03 0.9 65 3.3 0.97 0.9 3 3.0 0.94 0.9 349 8 8.84.3 0.8 088.6. 0.8 54.5.04 0.8 77 8 0.99.07 0.69 3.78.93 0.69 88.68.86 0.69 8 3.6.8 0.57 77.96.69 0.57 43.86.64 0.57 65 8 4 3.34.5 0.45 3.3.4 0.45 77 3.05.38 0.45 304 8 6 3.5.7 0.33 65 3.3.0 0.33 3 3.0.07 0.33 349 9 8.84.4 0.85 088.6.3 0.85 54.5.4 0.85 77 9 0.99.9 0.73 3.78.04 0.73 88.68.97 0.73 9 3.6.94 0.6 77.96.8 0.6 43.86.75 0.6 65 9 4 3.34.64 0.49 3.3.54 0.49 77 3.05.50 0.49 304 9 6 3.5.3 0.37 65 3.3.3 0.37 3 3.0.0 0.37 349 30 8.84.54 0.89 088.6.33 0.89 54.5.4 0.89 77 30 0.99.3 0.77 3.78.5 0.77 88.68.07 0.77 30 3.6.06 0.65 77.96.93 0.65 43.86.87 0.65 65 30 4 3.34.78 0.53 3.3.67 0.53 77 3.05.6 0.53 304 30 6 3.5.45 0.4 65 3.3.37 0.4 3 3.0.3 0.4 349 3 8.84.65 0.93 088.6.44 0.93 54.5.34 0.93 77 3 0.99.43 0.8 3.78.6 0.8 88.68.8 0.8 3 3.6.9 0.69 77.96.05 0.69 43.86.98 0.69 65 3 4 3.34.9 0.57 3.3.79 0.57 77 3.05.74 0.57 304 3 6 3.5.59 0.45 65 3.3.50 0.45 3 3.0.45 0.45 349 3 8.84.77 0.97 088.6.54 0.97 54.5.44 0.97 77 3 0.99.55 0.85 3.78.37 0.85 88.68.9 0.85 3 3.6.3 0.73 77.96.7 0.73 43.86.09 0.73 65 3 4 3.34.04 0.6 3.3.9 0.6 77 3.05.87 0.6 304 3 6 3.5.73 0.49 65 3.3.63 0.49 3 3.0.58 0.49 349 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 44

PERFORMNCE DT COOL operation (30V) MSC-C35VB - E MSC-G35VB - E (Single : Room ) : MUX-363VB - E CPCITY : 3.5(kW) SHF : 0.73 INPUT : 30(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 4..5 0.55 056 3.94.5 0.55 09 3.78.07 0.55 6 3.64.99 0.55 4 0 4.9.83 0.43 09 4..76 0.43 75 3.99.70 0.43 0 3.85.64 0.43 54 8 4..4 0.59 056 3.94.3 0.59 09 3.78. 0.59 6 3.64.4 0.59 4 0 4.9.00 0.47 09 4..9 0.47 75 3.99.86 0.47 0 3.85.80 0.47 54 4.46.55 0.35 48 4.3.49 0.35 4.0.46 0.35 54 4.03.40 0.35 307 3 8 4..58 0.63 056 3.94.47 0.63 09 3.78.37 0.63 6 3.64.8 0.63 4 3 0 4.9.7 0.5 09 4..09 0.5 75 3.99.0 0.5 0 3.85.95 0.5 54 3 4.46.73 0.39 48 4.3.67 0.39 4.0.63 0.39 54 4.03.56 0.39 307 4 8 4..74 0.67 056 3.94.63 0.67 09 3.78.5 0.67 6 3.64.43 0.67 4 4 0 4.9.35 0.55 09 4..5 0.55 75 3.99.8 0.55 0 3.85. 0.55 54 4 4.46.9 0.43 48 4.3.84 0.43 4.0.79 0.43 54 4.03.7 0.43 307 4 4 4.69.44 0.3 0 4.5.39 0.3 67 4.4.35 0.3 307 4.7.3 0.3 373 5 8 4..9 0.7 056 3.94.78 0.7 09 3.78.67 0.7 6 3.64.57 0.7 4 5 0 4.9.5 0.59 09 4..4 0.59 75 3.99.34 0.59 0 3.85.6 0.59 54 5 4.46.08 0.47 48 4.3.0 0.47 4.0.96 0.47 54 4.03.88 0.47 307 5 4 4.69.63 0.35 0 4.5.57 0.35 67 4.4.53 0.35 307 4.7.48 0.35 373 6 8 4. 3.07 0.75 056 3.94.94 0.75 09 3.78.8 0.75 6 3.64.7 0.75 4 6 0 4.9.69 0.63 09 4..58 0.63 75 3.99.50 0.63 0 3.85.4 0.63 54 6 4.46.6 0.5 48 4.3.8 0.5 4.0.3 0.5 54 4.03.04 0.5 307 6 4 4.69.8 0.39 0 4.5.75 0.39 67 4.4.7 0.39 307 4.7.65 0.39 373 6 6 4.83.9 0.7 67 4.69.5 0.7 333 4.6.3 0.7 373 4.48.0 0.7 4 7 8 4. 3.4 0.79 056 3.94 3.0 0.79 09 3.78.97 0.79 6 3.64.86 0.79 4 7 0 4.9.86 0.67 09 4..74 0.67 75 3.99.66 0.67 0 3.85.57 0.67 54 7 4.46.44 0.55 48 4.3.35 0.55 4.0.30 0.55 54 4.03.0 0.55 307 7 4 4.69.00 0.43 0 4.5.93 0.43 67 4.4.88 0.43 307 4.7.8 0.43 373 7 6 4.83.48 0.3 67 4.69.44 0.3 333 4.6.4 0.3 373 4.48.38 0.3 4 8 8 4. 3.40 0.83 056 3.94 3.6 0.83 09 3.78 3.3 0.83 6 3.64 3.0 0.83 4 8 0 4.9 3.03 0.7 09 4..9 0.7 75 3.99.8 0.7 0 3.85.7 0.7 54 8 4.46.6 0.59 48 4.3.53 0.59 4.0.47 0.59 54 4.03.36 0.59 307 8 4 4.69.9 0.47 0 4.5. 0.47 67 4.4.06 0.47 307 4.7.99 0.47 373 8 6 4.83.68 0.35 67 4.69.63 0.35 333 4.6.60 0.35 373 4.48.55 0.35 4 9 8 4. 3.57 0.87 056 3.94 3.4 0.87 09 3.78 3.8 0.87 6 3.64 3.6 0.87 4 9 0 4.9 3.0 0.75 09 4. 3.07 0.75 75 3.99.98 0.75 0 3.85.88 0.75 54 9 4.46.80 0.63 48 4.3.70 0.63 4.0.63 0.63 54 4.03.5 0.63 307 9 4 4.69.38 0.5 0 4.5.9 0.5 67 4.4.4 0.5 307 4.7.6 0.5 373 9 6 4.83.87 0.39 67 4.69.8 0.39 333 4.6.79 0.39 373 4.48.73 0.39 4 30 8 4. 3.73 0.9 056 3.94 3.57 0.9 09 3.78 3.43 0.9 6 3.64 3.30 0.9 4 30 0 4.9 3.37 0.79 09 4. 3.4 0.79 75 3.99 3.4 0.79 0 3.85 3.03 0.79 54 30 4.46.98 0.67 48 4.3.87 0.67 4.0.80 0.67 54 4.03.68 0.67 307 30 4 4.69.57 0.55 0 4.5.47 0.55 67 4.4.4 0.55 307 4.7.34 0.55 373 30 6 4.83.06 0.43 67 4.69.00 0.43 333 4.6.97 0.43 373 4.48.9 0.43 4 3 8 4. 3.89 0.95 056 3.94 3.73 0.95 09 3.78 3.58 0.95 6 3.64 3.45 0.95 4 3 0 4.9 3.55 0.83 09 4. 3.40 0.83 75 3.99 3.30 0.83 0 3.85 3.8 0.83 54 3 4.46 3.5 0.7 48 4.3 3.04 0.7 4.0.97 0.7 54 4.03.85 0.7 307 3 4 4.69.75 0.59 0 4.5.65 0.59 67 4.4.59 0.59 307 4.7.5 0.59 373 3 6 4.83.6 0.47 67 4.69.9 0.47 333 4.6.6 0.47 373 4.48.09 0.47 4 3 8 4. 4.06 0.99 056 3.94 3.89 0.99 09 3.78 3.73 0.99 6 3.64 3.59 0.99 4 3 0 4.9 3.7 0.87 09 4. 3.57 0.87 75 3.99 3.46 0.87 0 3.85 3.34 0.87 54 3 4.46 3.33 0.75 48 4.3 3. 0.75 4.0 3.4 0.75 54 4.03 3.0 0.75 307 3 4 4.69.94 0.63 0 4.5.83 0.63 67 4.4.77 0.63 307 4.7.68 0.63 373 3 6 4.83.45 0.5 67 4.69.38 0.5 333 4.6.34 0.5 373 4.48.7 0.5 4 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 45

PERFORMNCE DT COOL operation (30V) MSC-C35VB - E MSC-G35VB - E (Single : Room ) : MUX-363VB - E CPCITY : 3.5(kW) SHF : 0.73 INPUT : 30(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.43.88 0.55 94 3.5.7 0.55 373 3.03.66 0.55 399 0 3.6.54 0.43 346 3.36.43 0.43 4 3.4.38 0.43 45 8 3.43.0 0.59 94 3.5.85 0.59 373 3.03.78 0.59 399 0 3.6.68 0.47 346 3.36.57 0.47 4 3.4.5 0.47 45 3.8.3 0.35 399 3.57.4 0.35 478 3.45.0 0.35 505 3 8 3.43.5 0.63 94 3.5.98 0.63 373 3.03.90 0.63 399 3 0 3.6.83 0.5 346 3.36.70 0.5 4 3.4.64 0.5 45 3 3.8.48 0.39 399 3.57.38 0.39 478 3.45.33 0.39 505 4 8 3.43.9 0.67 94 3.5.0 0.67 373 3.03.0 0.67 399 4 0 3.6.97 0.55 346 3.36.84 0.55 4 3.4.77 0.55 45 4 3.8.63 0.43 399 3.57.5 0.43 478 3.45.47 0.43 505 4 4 4.03.4 0.3 45 3.78.6 0.3 58 3.68.3 0.3 55 5 8 3.43.43 0.7 94 3.5.3 0.7 373 3.03.4 0.7 399 5 0 3.6. 0.59 346 3.36.97 0.59 4 3.4.90 0.59 45 5 3.8.78 0.47 399 3.57.67 0.47 478 3.45.6 0.47 505 5 4 4.03.40 0.35 45 3.78.3 0.35 58 3.68.8 0.35 55 6 8 3.43.56 0.75 94 3.5.35 0.75 373 3.03.6 0.75 399 6 0 3.6.6 0.63 346 3.36. 0.63 4 3.4.03 0.63 45 6 3.8.93 0.5 399 3.57.8 0.5 478 3.45.75 0.5 505 6 4 4.03.56 0.39 45 3.78.46 0.39 58 3.68.4 0.39 55 6 6 4.4.3 0.7 505 3.99.07 0.7 57 3.87.03 0.7 604 7 8 3.43.70 0.79 94 3.5.48 0.79 373 3.03.38 0.79 399 7 0 3.6.40 0.67 346 3.36.4 0.67 4 3.4.6 0.67 45 7 3.8.09 0.55 399 3.57.95 0.55 478 3.45.89 0.55 505 7 4 4.03.7 0.43 45 3.78.6 0.43 58 3.68.57 0.43 55 7 6 4.4.30 0.3 505 3.99. 0.3 57 3.87.9 0.3 604 8 8 3.43.84 0.83 94 3.5.6 0.83 373 3.03.50 0.83 399 8 0 3.6.55 0.7 346 3.36.38 0.7 4 3.4.9 0.7 45 8 3.8.4 0.59 399 3.57.0 0.59 478 3.45.0 0.59 505 8 4 4.03.88 0.47 45 3.78.77 0.47 58 3.68.7 0.47 55 8 6 4.4.47 0.35 505 3.99.38 0.35 57 3.87.34 0.35 604 9 8 3.43.97 0.87 94 3.5.73 0.87 373 3.03.6 0.87 399 9 0 3.6.69 0.75 346 3.36.5 0.75 4 3.4.4 0.75 45 9 3.8.39 0.63 399 3.57.4 0.63 478 3.45.6 0.63 505 9 4 4.03.04 0.5 45 3.78.9 0.5 58 3.68.86 0.5 55 9 6 4.4.64 0.39 505 3.99.54 0.39 57 3.87.50 0.39 604 30 8 3.43 3. 0.9 94 3.5.86 0.9 373 3.03.75 0.9 399 30 0 3.6.84 0.79 346 3.36.64 0.79 4 3.4.55 0.79 45 30 3.8.54 0.67 399 3.57.38 0.67 478 3.45.30 0.67 505 30 4 4.03.0 0.55 45 3.78.07 0.55 58 3.68.0 0.55 55 30 6 4.4.8 0.43 505 3.99.70 0.43 57 3.87.65 0.43 604 3 8 3.43 3.5 0.95 94 3.5.98 0.95 373 3.03.87 0.95 399 3 0 3.6.98 0.83 346 3.36.78 0.83 4 3.4.68 0.83 45 3 3.8.70 0.7 399 3.57.5 0.7 478 3.45.44 0.7 505 3 4 4.03.36 0.59 45 3.78. 0.59 58 3.68.6 0.59 55 3 6 4.4.98 0.47 505 3.99.86 0.47 57 3.87.8 0.47 604 3 8 3.43 3.39 0.99 94 3.5 3. 0.99 373 3.03.99 0.99 399 3 0 3.6 3.3 0.87 346 3.36.9 0.87 4 3.4.8 0.87 45 3 3.8.85 0.75 399 3.57.67 0.75 478 3.45.58 0.75 505 3 4 4.03.5 0.63 45 3.78.37 0.63 58 3.68.30 0.63 55 3 6 4.4.5 0.5 505 3.99.0 0.5 57 3.87.96 0.5 604 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 46

PERFORMNCE DT COOL operation (30V) MSC-C0VB - E MSC-G0VB - E (Single : Room B or C) : MUX-363VB - E CPCITY :.4(kW) SHF : 0.74 INPUT : 850(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.8.58 0.56 680.70.5 0.56 74.59.45 0.56 748.50.40 0.56 78 0.94.9 0.44 74.8.4 0.44 757.74.0 0.44 774.64.6 0.44 808 8.8.69 0.60 680.70.6 0.60 74.59.56 0.60 748.50.50 0.60 78 0.94.4 0.48 74.8.35 0.48 757.74.3 0.48 774.64.7 0.48 808 3.06.0 0.36 740.95.06 0.36 786.88.04 0.36 808.76 0.99 0.36 84 3 8.8.80 0.64 680.70.73 0.64 74.59.66 0.64 748.50.60 0.64 78 3 0.94.53 0.5 74.8.47 0.5 757.74.4 0.5 774.64.37 0.5 808 3 3.06. 0.40 740.95.8 0.40 786.88.5 0.40 808.76.0 0.40 84 4 8.8.9 0.68 680.70.84 0.68 74.59.76 0.68 748.50.70 0.68 78 4 0.94.65 0.56 74.8.58 0.56 757.74.53 0.56 774.64.48 0.56 808 4 3.06.35 0.44 740.95.30 0.44 786.88.7 0.44 808.76. 0.44 84 4 4 3..03 0.3 774 3.0 0.99 0.3 86 3.0 0.97 0.3 84.93 0.94 0.3 884 5 8.8.03 0.7 680.70.94 0.7 74.59.87 0.7 748.50.80 0.7 78 5 0.94.76 0.60 74.8.69 0.60 757.74.64 0.60 774.64.58 0.60 808 5 3.06.47 0.48 740.95.4 0.48 786.88.38 0.48 808.76.3 0.48 84 5 4 3..6 0.36 774 3.0. 0.36 86 3.0.09 0.36 84.93.05 0.36 884 6 8.8.4 0.76 680.70.05 0.76 74.59.97 0.76 748.50.90 0.76 78 6 0.94.88 0.64 74.8.80 0.64 757.74.75 0.64 774.64.69 0.64 808 6 3.06.59 0.5 740.95.54 0.5 786.88.50 0.5 808.76.44 0.5 84 6 4 3..9 0.40 774 3.0.4 0.40 86 3.0. 0.40 84.93.7 0.40 884 6 6 3.3 0.93 0.8 86 3. 0.90 0.8 859 3.7 0.89 0.8 884 3.07 0.86 0.8 90 7 8.8.6 0.80 680.70.6 0.80 74.59.07 0.80 748.50.00 0.80 78 7 0.94.00 0.68 74.8.9 0.68 757.74.86 0.68 774.64.80 0.68 808 7 3.06.7 0.56 740.95.65 0.56 786.88.6 0.56 808.76.55 0.56 84 7 4 3..4 0.44 774 3.0.36 0.44 86 3.0.33 0.44 84.93.9 0.44 884 7 6 3.3.06 0.3 86 3..03 0.3 859 3.7.0 0.3 884 3.07 0.98 0.3 90 8 8.8.37 0.84 680.70.7 0.84 74.59.8 0.84 748.50.0 0.84 78 8 0.94. 0.7 74.8.03 0.7 757.74.97 0.7 774.64.90 0.7 808 8 3.06.84 0.60 740.95.77 0.60 786.88.73 0.60 808.76.66 0.60 84 8 4 3..54 0.48 774 3.0.49 0.48 86 3.0.45 0.48 84.93.4 0.48 884 8 6 3.3.9 0.36 86 3..6 0.36 859 3.7.4 0.36 884 3.07. 0.36 90 9 8.8.48 0.88 680.70.38 0.88 74.59.8 0.88 748.50.0 0.88 78 9 0.94.3 0.76 74.8.4 0.76 757.74.08 0.76 774.64.0 0.76 808 9 3.06.96 0.64 740.95.89 0.64 786.88.84 0.64 808.76.77 0.64 84 9 4 3..67 0.5 774 3.0.6 0.5 86 3.0.57 0.5 84.93.5 0.5 884 9 6 3.3.3 0.40 86 3..9 0.40 859 3.7.7 0.40 884 3.07.3 0.40 90 30 8.8.59 0.9 680.70.48 0.9 74.59.38 0.9 748.50.30 0.9 78 30 0.94.35 0.80 74.8.6 0.80 757.74.9 0.80 774.64. 0.80 808 30 3.06.08 0.68 740.95.0 0.68 786.88.96 0.68 808.76.88 0.68 84 30 4 3..80 0.56 774 3.0.73 0.56 86 3.0.69 0.56 84.93.64 0.56 884 30 6 3.3.46 0.44 86 3..4 0.44 859 3.7.39 0.44 884 3.07.35 0.44 90 3 8.8.7 0.96 680.70.59 0.96 74.59.49 0.96 748.50.40 0.96 78 3 0.94.47 0.84 74.8.37 0.84 757.74.30 0.84 774.64. 0.84 808 3 3.06.0 0.7 740.95.3 0.7 786.88.07 0.7 808.76.99 0.7 84 3 4 3..93 0.60 774 3.0.86 0.60 86 3.0.8 0.60 84.93.76 0.60 884 3 6 3.3.59 0.48 86 3..54 0.48 859 3.7.5 0.48 884 3.07.47 0.48 90 3 8.8.8.00 680.70.70.00 74.59.59.00 748.50.50.00 78 3 0.94.59 0.88 74.8.48 0.88 757.74.4 0.88 774.64.3 0.88 808 3 3.06.33 0.76 740.95.4 0.76 786.88.9 0.76 808.76.0 0.76 84 3 4 3..06 0.64 774 3.0.98 0.64 86 3.0.94 0.64 84.93.87 0.64 884 3 6 3.3.7 0.5 86 3..67 0.5 859 3.7.65 0.5 884 3.07.60 0.5 90 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 47

PERFORMNCE DT COOL operation (30V) MSC-C0VB - E MSC-G0VB - E (Single : Room B or C) : MUX-363VB - E CPCITY :.4(kW) SHF : 0.74 INPUT : 850(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.35.3 0.56 833.6. 0.56 884.08.6 0.56 90 0.47.09 0.44 867.30.0 0.44 90. 0.98 0.44 935 8.35.4 0.60 833.6.30 0.60 884.08.5 0.60 90 0.47.9 0.48 867.30. 0.48 90..07 0.48 935.6 0.94 0.36 90.45 0.88 0.36 95.36 0.85 0.36 969 3 8.35.5 0.64 833.6.38 0.64 884.08.33 0.64 90 3 0.47.9 0.5 867.30.0 0.5 90..5 0.5 935 3.6.05 0.40 90.45 0.98 0.40 95.36 0.95 0.40 969 4 8.35.60 0.68 833.6.47 0.68 884.08.4 0.68 90 4 0.47.38 0.56 867.30.9 0.56 90..4 0.56 935 4.6.5 0.44 90.45.08 0.44 95.36.04 0.44 969 4 4.76 0.88 0.3 935.59 0.83 0.3 978.5 0.8 0.3 999 5 8.35.69 0.7 833.6.56 0.7 884.08.49 0.7 90 5 0.47.48 0.60 867.30.38 0.60 90..33 0.60 935 5.6.6 0.48 90.45.8 0.48 95.36.3 0.48 969 5 4.76 0.99 0.36 935.59 0.93 0.36 978.5 0.9 0.36 999 6 8.35.79 0.76 833.6.64 0.76 884.08.58 0.76 90 6 0.47.58 0.64 867.30.47 0.64 90..4 0.64 935 6.6.36 0.5 90.45.7 0.5 95.36.3 0.5 969 6 4.76.0 0.40 935.59.04 0.40 978.5.0 0.40 999 6 6.90 0.8 0.8 969.74 0.77 0.8 0.65 0.74 0.8 033 7 8.35.88 0.80 833.6.73 0.80 884.08.66 0.80 90 7 0.47.68 0.68 867.30.57 0.68 90..5 0.68 935 7.6.46 0.56 90.45.37 0.56 95.36.3 0.56 969 7 4.76. 0.44 935.59.4 0.44 978.5. 0.44 999 7 6.90 0.93 0.3 969.74 0.88 0.3 0.65 0.85 0.3 033 8 8.35.98 0.84 833.6.8 0.84 884.08.74 0.84 90 8 0.47.78 0.7 867.30.66 0.7 90..60 0.7 935 8.6.57 0.60 90.45.47 0.60 95.36.4 0.60 969 8 4.76.3 0.48 935.59.4 0.48 978.5. 0.48 999 8 6.90.05 0.36 969.74 0.98 0.36 0.65 0.95 0.36 033 9 8.35.07 0.88 833.6.90 0.88 884.08.83 0.88 90 9 0.47.88 0.76 867.30.75 0.76 90..69 0.76 935 9.6.67 0.64 90.45.57 0.64 95.36.5 0.64 969 9 4.76.44 0.5 935.59.35 0.5 978.5.3 0.5 999 9 6.90.6 0.40 969.74.09 0.40 0.65.06 0.40 033 30 8.35.6 0.9 833.6.99 0.9 884.08.9 0.9 90 30 0.47.98 0.80 867.30.84 0.80 90..78 0.80 935 30.6.78 0.68 90.45.66 0.68 95.36.6 0.68 969 30 4.76.55 0.56 935.59.45 0.56 978.5.4 0.56 999 30 6.90.8 0.44 969.74.0 0.44 0.65.7 0.44 033 3 8.35.6 0.96 833.6.07 0.96 884.08.99 0.96 90 3 0.47.08 0.84 867.30.94 0.84 90..86 0.84 935 3.6.88 0.7 90.45.76 0.7 95.36.70 0.7 969 3 4.76.66 0.60 935.59.56 0.60 978.5.5 0.60 999 3 6.90.39 0.48 969.74.3 0.48 0.65.7 0.48 033 3 8.35.35.00 833.6.6.00 884.08.08.00 90 3 0.47.8 0.88 867.30.03 0.88 90..95 0.88 935 3.6.99 0.76 90.45.86 0.76 95.36.80 0.76 969 3 4.76.77 0.64 935.59.66 0.64 978.5.6 0.64 999 3 6.90.5 0.5 969.74.4 0.5 0.65.38 0.5 033 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 48

PERFORMNCE DT COOL operation (30V) MSC-C35VB - E MSC-G35VB - E (Single) : MUX-70VB - E CPCITY : 3.5(kW) SHF : 0.73 INPUT : 340(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 4..5 0.55 07 3.94.5 0.55 6 3.78.07 0.55 79 3.64.99 0.55 33 0 4.9.83 0.43 6 4..76 0.43 93 3.99.70 0.43 9 3.85.64 0.43 73 8 4..4 0.59 07 3.94.3 0.59 6 3.78. 0.59 79 3.64.4 0.59 33 0 4.9.00 0.47 6 4..9 0.47 93 3.99.86 0.47 9 3.85.80 0.47 73 4.46.55 0.35 66 4.3.49 0.35 40 4.0.46 0.35 73 4.03.40 0.35 37 3 8 4..58 0.63 07 3.94.47 0.63 6 3.78.37 0.63 79 3.64.8 0.63 33 3 0 4.9.7 0.5 6 4..09 0.5 93 3.99.0 0.5 9 3.85.95 0.5 73 3 4.46.73 0.39 66 4.3.67 0.39 40 4.0.63 0.39 73 4.03.56 0.39 37 4 8 4..74 0.67 07 3.94.63 0.67 6 3.78.5 0.67 79 3.64.43 0.67 33 4 0 4.9.35 0.55 6 4..5 0.55 93 3.99.8 0.55 9 3.85. 0.55 73 4 4.46.9 0.43 66 4.3.84 0.43 40 4.0.79 0.43 73 4.03.7 0.43 37 4 4 4.69.44 0.3 9 4.5.39 0.3 86 4.4.35 0.3 37 4.7.3 0.3 394 5 8 4..9 0.7 07 3.94.78 0.7 6 3.78.67 0.7 79 3.64.57 0.7 33 5 0 4.9.5 0.59 6 4..4 0.59 93 3.99.34 0.59 9 3.85.6 0.59 73 5 4.46.08 0.47 66 4.3.0 0.47 40 4.0.96 0.47 73 4.03.88 0.47 37 5 4 4.69.63 0.35 9 4.5.57 0.35 86 4.4.53 0.35 37 4.7.48 0.35 394 6 8 4. 3.07 0.75 07 3.94.94 0.75 6 3.78.8 0.75 79 3.64.7 0.75 33 6 0 4.9.69 0.63 6 4..58 0.63 93 3.99.50 0.63 9 3.85.4 0.63 73 6 4.46.6 0.5 66 4.3.8 0.5 40 4.0.3 0.5 73 4.03.04 0.5 37 6 4 4.69.8 0.39 9 4.5.75 0.39 86 4.4.7 0.39 37 4.7.65 0.39 394 6 6 4.83.9 0.7 86 4.69.5 0.7 353 4.6.3 0.7 394 4.48.0 0.7 434 7 8 4. 3.4 0.79 07 3.94 3.0 0.79 6 3.78.97 0.79 79 3.64.86 0.79 33 7 0 4.9.86 0.67 6 4..74 0.67 93 3.99.66 0.67 9 3.85.57 0.67 73 7 4.46.44 0.55 66 4.3.35 0.55 40 4.0.30 0.55 73 4.03.0 0.55 37 7 4 4.69.00 0.43 9 4.5.93 0.43 86 4.4.88 0.43 37 4.7.8 0.43 394 7 6 4.83.48 0.3 86 4.69.44 0.3 353 4.6.4 0.3 394 4.48.38 0.3 434 8 8 4. 3.40 0.83 07 3.94 3.6 0.83 6 3.78 3.3 0.83 79 3.64 3.0 0.83 33 8 0 4.9 3.03 0.7 6 4..9 0.7 93 3.99.8 0.7 9 3.85.7 0.7 73 8 4.46.6 0.59 66 4.3.53 0.59 40 4.0.47 0.59 73 4.03.36 0.59 37 8 4 4.69.9 0.47 9 4.5. 0.47 86 4.4.06 0.47 37 4.7.99 0.47 394 8 6 4.83.68 0.35 86 4.69.63 0.35 353 4.6.60 0.35 394 4.48.55 0.35 434 9 8 4. 3.57 0.87 07 3.94 3.4 0.87 6 3.78 3.8 0.87 79 3.64 3.6 0.87 33 9 0 4.9 3.0 0.75 6 4. 3.07 0.75 93 3.99.98 0.75 9 3.85.88 0.75 73 9 4.46.80 0.63 66 4.3.70 0.63 40 4.0.63 0.63 73 4.03.5 0.63 37 9 4 4.69.38 0.5 9 4.5.9 0.5 86 4.4.4 0.5 37 4.7.6 0.5 394 9 6 4.83.87 0.39 86 4.69.8 0.39 353 4.6.79 0.39 394 4.48.73 0.39 434 30 8 4. 3.73 0.9 07 3.94 3.57 0.9 6 3.78 3.43 0.9 79 3.64 3.30 0.9 33 30 0 4.9 3.37 0.79 6 4. 3.4 0.79 93 3.99 3.4 0.79 9 3.85 3.03 0.79 73 30 4.46.98 0.67 66 4.3.87 0.67 40 4.0.80 0.67 73 4.03.68 0.67 37 30 4 4.69.57 0.55 9 4.5.47 0.55 86 4.4.4 0.55 37 4.7.34 0.55 394 30 6 4.83.06 0.43 86 4.69.00 0.43 353 4.6.97 0.43 394 4.48.9 0.43 434 3 8 4. 3.89 0.95 07 3.94 3.73 0.95 6 3.78 3.58 0.95 79 3.64 3.45 0.95 33 3 0 4.9 3.55 0.83 6 4. 3.40 0.83 93 3.99 3.30 0.83 9 3.85 3.8 0.83 73 3 4.46 3.5 0.7 66 4.3 3.04 0.7 40 4.0.97 0.7 73 4.03.85 0.7 37 3 4 4.69.75 0.59 9 4.5.65 0.59 86 4.4.59 0.59 37 4.7.5 0.59 394 3 6 4.83.6 0.47 86 4.69.9 0.47 353 4.6.6 0.47 394 4.48.09 0.47 434 3 8 4. 4.06 0.99 07 3.94 3.89 0.99 6 3.78 3.73 0.99 79 3.64 3.59 0.99 33 3 0 4.9 3.7 0.87 6 4. 3.57 0.87 93 3.99 3.46 0.87 9 3.85 3.34 0.87 73 3 4.46 3.33 0.75 66 4.3 3. 0.75 40 4.0 3.4 0.75 73 4.03 3.0 0.75 37 3 4 4.69.94 0.63 9 4.5.83 0.63 86 4.4.77 0.63 37 4.7.68 0.63 394 3 6 4.83.45 0.5 86 4.69.38 0.5 353 4.6.34 0.5 394 4.48.7 0.5 434 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 49

PERFORMNCE DT COOL operation (30V) MSC-C35VB - E MSC-G35VB - E (Single) : MUX-70VB - E CPCITY : 3.5(kW) SHF : 0.73 INPUT : 340(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.43.88 0.55 33 3.5.7 0.55 394 3.03.66 0.55 40 0 3.6.54 0.43 367 3.36.43 0.43 434 3.4.38 0.43 474 8 3.43.0 0.59 33 3.5.85 0.59 394 3.03.78 0.59 40 0 3.6.68 0.47 367 3.36.57 0.47 434 3.4.5 0.47 474 3.8.3 0.35 40 3.57.4 0.35 50 3.45.0 0.35 58 3 8 3.43.5 0.63 33 3.5.98 0.63 394 3.03.90 0.63 40 3 0 3.6.83 0.5 367 3.36.70 0.5 434 3.4.64 0.5 474 3 3.8.48 0.39 40 3.57.38 0.39 50 3.45.33 0.39 58 4 8 3.43.9 0.67 33 3.5.0 0.67 394 3.03.0 0.67 40 4 0 3.6.97 0.55 367 3.36.84 0.55 434 3.4.77 0.55 474 4 3.8.63 0.43 40 3.57.5 0.43 50 3.45.47 0.43 58 4 4 4.03.4 0.3 474 3.78.6 0.3 54 3.68.3 0.3 575 5 8 3.43.43 0.7 33 3.5.3 0.7 394 3.03.4 0.7 40 5 0 3.6. 0.59 367 3.36.97 0.59 434 3.4.90 0.59 474 5 3.8.78 0.47 40 3.57.67 0.47 50 3.45.6 0.47 58 5 4 4.03.40 0.35 474 3.78.3 0.35 54 3.68.8 0.35 575 6 8 3.43.56 0.75 33 3.5.35 0.75 394 3.03.6 0.75 40 6 0 3.6.6 0.63 367 3.36. 0.63 434 3.4.03 0.63 474 6 3.8.93 0.5 40 3.57.8 0.5 50 3.45.75 0.5 58 6 4 4.03.56 0.39 474 3.78.46 0.39 54 3.68.4 0.39 575 6 6 4.4.3 0.7 58 3.99.07 0.7 595 3.87.03 0.7 68 7 8 3.43.70 0.79 33 3.5.48 0.79 394 3.03.38 0.79 40 7 0 3.6.40 0.67 367 3.36.4 0.67 434 3.4.6 0.67 474 7 3.8.09 0.55 40 3.57.95 0.55 50 3.45.89 0.55 58 7 4 4.03.7 0.43 474 3.78.6 0.43 54 3.68.57 0.43 575 7 6 4.4.30 0.3 58 3.99. 0.3 595 3.87.9 0.3 68 8 8 3.43.84 0.83 33 3.5.6 0.83 394 3.03.50 0.83 40 8 0 3.6.55 0.7 367 3.36.38 0.7 434 3.4.9 0.7 474 8 3.8.4 0.59 40 3.57.0 0.59 50 3.45.0 0.59 58 8 4 4.03.88 0.47 474 3.78.77 0.47 54 3.68.7 0.47 575 8 6 4.4.47 0.35 58 3.99.38 0.35 595 3.87.34 0.35 68 9 8 3.43.97 0.87 33 3.5.73 0.87 394 3.03.6 0.87 40 9 0 3.6.69 0.75 367 3.36.5 0.75 434 3.4.4 0.75 474 9 3.8.39 0.63 40 3.57.4 0.63 50 3.45.6 0.63 58 9 4 4.03.04 0.5 474 3.78.9 0.5 54 3.68.86 0.5 575 9 6 4.4.64 0.39 58 3.99.54 0.39 595 3.87.50 0.39 68 30 8 3.43 3. 0.9 33 3.5.86 0.9 394 3.03.75 0.9 40 30 0 3.6.84 0.79 367 3.36.64 0.79 434 3.4.55 0.79 474 30 3.8.54 0.67 40 3.57.38 0.67 50 3.45.30 0.67 58 30 4 4.03.0 0.55 474 3.78.07 0.55 54 3.68.0 0.55 575 30 6 4.4.8 0.43 58 3.99.70 0.43 595 3.87.65 0.43 68 3 8 3.43 3.5 0.95 33 3.5.98 0.95 394 3.03.87 0.95 40 3 0 3.6.98 0.83 367 3.36.78 0.83 434 3.4.68 0.83 474 3 3.8.70 0.7 40 3.57.5 0.7 50 3.45.44 0.7 58 3 4 4.03.36 0.59 474 3.78. 0.59 54 3.68.6 0.59 575 3 6 4.4.98 0.47 58 3.99.86 0.47 595 3.87.8 0.47 68 3 8 3.43 3.39 0.99 33 3.5 3. 0.99 394 3.03.99 0.99 40 3 0 3.6 3.3 0.87 367 3.36.9 0.87 434 3.4.8 0.87 474 3 3.8.85 0.75 40 3.57.67 0.75 50 3.45.58 0.75 58 3 4 4.03.5 0.63 474 3.78.37 0.63 54 3.68.30 0.63 575 3 6 4.4.5 0.5 58 3.99.0 0.5 595 3.87.96 0.5 68 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 50

PERFORMNCE DT COOL operation (30V) MSC-C5VB - MSC-G5VB - (Single : Room C ) : MUX-473VB - E CPCITY :.75(kW) SHF :0.73 INPUT : 050(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.3.76 0.55 840 3.09.69 0.55 88.97.6 0.55 94.86.56 0.55 966 0 3.37.43 0.43 88 3.3.37 0.43 935 3.4.33 0.43 956 3.03.9 0.43 998 8 3.3.89 0.59 840 3.09.8 0.59 88.97.74 0.59 94.86.67 0.59 966 0 3.37.57 0.47 88 3.3.50 0.47 935 3.4.46 0.47 956 3.03.4 0.47 998 3.5. 0.35 94 3.38.7 0.35 97 3.30.4 0.35 998 3.6.09 0.35 040 3 8 3.3.0 0.63 840 3.09.93 0.63 88.97.86 0.63 94.86.79 0.63 966 3 0 3.37.70 0.5 88 3.3.63 0.5 935 3.4.58 0.5 956 3.03.53 0.5 998 3 3.5.35 0.39 94 3.38.30 0.39 97 3.30.7 0.39 998 3.6. 0.39 040 4 8 3.3.5 0.67 840 3.09.06 0.67 88.97.98 0.67 94.86.90 0.67 966 4 0 3.37.84 0.55 88 3.3.76 0.55 935 3.4.7 0.55 956 3.03.65 0.55 998 4 3.5.49 0.43 94 3.38.44 0.43 97 3.30.40 0.43 998 3.6.34 0.43 040 4 4 3.69. 0.3 956 3.55.08 0.3 008 3.47.06 0.3 040 3.36.0 0.3 09 5 8 3.3.8 0.7 840 3.09.8 0.7 88.97.09 0.7 94.86.0 0.7 966 5 0 3.37.97 0.59 88 3.3.89 0.59 935 3.4.83 0.59 956 3.03.77 0.59 998 5 3.5.63 0.47 94 3.38.57 0.47 97 3.30.53 0.47 998 3.6.47 0.47 040 5 4 3.69.7 0.35 956 3.55. 0.35 008 3.47.0 0.35 040 3.36.6 0.35 09 6 8 3.3.4 0.75 840 3.09.30 0.75 88.97. 0.75 94.86.3 0.75 966 6 0 3.37. 0.63 88 3.3.0 0.63 935 3.4.96 0.63 956 3.03.89 0.63 998 6 3.5.77 0.5 94 3.38.7 0.5 97 3.30.67 0.5 998 3.6.60 0.5 040 6 4 3.69.4 0.39 956 3.55.37 0.39 008 3.47.33 0.39 040 3.36.9 0.39 09 6 6 3.80.0 0.7 008 3.69 0.98 0.7 06 3.63 0.96 0.7 09 3.5 0.93 0.7 4 7 8 3.3.54 0.79 840 3.09.43 0.79 88.97.33 0.79 94.86.5 0.79 966 7 0 3.37.4 0.67 88 3.3.5 0.67 935 3.4.08 0.67 956 3.03.0 0.67 998 7 3.5.9 0.55 94 3.38.84 0.55 97 3.30.80 0.55 998 3.6.7 0.55 040 7 4 3.69.57 0.43 956 3.55.5 0.43 008 3.47.47 0.43 040 3.36.43 0.43 09 7 6 3.80.6 0.3 008 3.69. 0.3 06 3.63. 0.3 09 3.5.07 0.3 4 8 8 3.3.67 0.83 840 3.09.55 0.83 88.97.45 0.83 94.86.36 0.83 966 8 0 3.37.37 0.7 88 3.3.8 0.7 935 3.4. 0.7 956 3.03.3 0.7 998 8 3.5.05 0.59 94 3.38.98 0.59 97 3.30.93 0.59 998 3.6.85 0.59 040 8 4 3.69.7 0.47 956 3.55.65 0.47 008 3.47.6 0.47 040 3.36.56 0.47 09 8 6 3.80.3 0.35 008 3.69.7 0.35 06 3.63.5 0.35 09 3.5. 0.35 4 9 8 3.3.80 0.87 840 3.09.68 0.87 88.97.57 0.87 94.86.47 0.87 966 9 0 3.37.5 0.75 88 3.3.4 0.75 935 3.4.34 0.75 956 3.03.5 0.75 998 9 3.5.9 0.63 94 3.38. 0.63 97 3.30.06 0.63 998 3.6.98 0.63 040 9 4 3.69.86 0.5 956 3.55.79 0.5 008 3.47.75 0.5 040 3.36.69 0.5 09 9 6 3.80.46 0.39 008 3.69.4 0.39 06 3.63.40 0.39 09 3.5.36 0.39 4 30 8 3.3.9 0.9 840 3.09.80 0.9 88.97.69 0.9 94.86.59 0.9 966 30 0 3.37.64 0.79 88 3.3.54 0.79 935 3.4.46 0.79 956 3.03.37 0.79 998 30 3.5.33 0.67 94 3.38.5 0.67 97 3.30.9 0.67 998 3.6.0 0.67 040 30 4 3.69.0 0.55 956 3.55.93 0.55 008 3.47.89 0.55 040 3.36.83 0.55 09 30 6 3.80.6 0.43 008 3.69.57 0.43 06 3.63.54 0.43 09 3.5.50 0.43 4 3 8 3.3 3.05 0.95 840 3.09.9 0.95 88.97.8 0.95 94.86.70 0.95 966 3 0 3.37.78 0.83 88 3.3.67 0.83 935 3.4.59 0.83 956 3.03.50 0.83 998 3 3.5.47 0.7 94 3.38.38 0.7 97 3.30.33 0.7 998 3.6.3 0.7 040 3 4 3.69.6 0.59 956 3.55.08 0.59 008 3.47.03 0.59 040 3.36.96 0.59 09 3 6 3.80.76 0.47 008 3.69.7 0.47 06 3.63.69 0.47 09 3.5.64 0.47 4 3 8 3.3 3.8 0.99 840 3.09 3.05 0.99 88.97.93 0.99 94.86.8 0.99 966 3 0 3.37.9 0.87 88 3.3.80 0.87 935 3.4.7 0.87 956 3.03.6 0.87 998 3 3.5.6 0.75 94 3.38.5 0.75 97 3.30.46 0.75 998 3.6.36 0.75 040 3 4 3.69.30 0.63 956 3.55. 0.63 008 3.47.7 0.63 040 3.36.0 0.63 09 3 6 3.80.9 0.5 008 3.69.86 0.5 06 3.63.83 0.5 09 3.5.78 0.5 4 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 5

PERFORMNCE DT COOL operation (30V) MSC-C5VB - MSC-G5VB - (Single : Room C) : MUX-473VB - E CPCITY :.75(kW) SHF : 0.73 INPUT : 050(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8.70.47 0.55 09.48.35 0.55 09.38.30 0.55 3 0.83.0 0.43 07.64. 0.43 4.54.08 0.43 55 8.70.58 0.59 09.48.45 0.59 09.38.39 0.59 3 0.83.3 0.47 07.64.3 0.47 4.54.8 0.47 55 3.00.03 0.35 3.8 0.97 0.35 76.7 0.93 0.35 97 3 8.70.68 0.63 09.48.55 0.63 09.38.49 0.63 3 3 0.83.43 0.5 07.64.33 0.5 4.54.8 0.5 55 3 3.00.5 0.39 3.8.08 0.39 76.7.04 0.39 97 4 8.70.79 0.67 09.48.65 0.67 09.38.58 0.67 3 4 0.83.54 0.55 07.64.44 0.55 4.54.39 0.55 55 4 3.00.7 0.43 3.8.9 0.43 76.7.5 0.43 97 4 4 3.6 0.96 0.3 55.97 0.9 0.3 08.89 0.88 0.3 34 5 8.70.90 0.7 09.48.74 0.7 09.38.68 0.7 3 5 0.83.66 0.59 07.64.54 0.59 4.54.49 0.59 55 5 3.00.39 0.47 3.8.30 0.47 76.7.6 0.47 97 5 4 3.6.09 0.35 55.97.0 0.35 08.89.00 0.35 34 6 8.70.0 0.75 09.48.84 0.75 09.38.77 0.75 3 6 0.83.77 0.63 07.64.65 0.63 4.54.59 0.63 55 6 3.00.5 0.5 3.8.4 0.5 76.7.37 0.5 97 6 4 3.6. 0.39 55.97.4 0.39 08.89. 0.39 34 6 6 3.33 0.88 0.7 97 3.4 0.83 0.7 50 3.04 0.8 0.7 76 7 8.70. 0.79 09.48.94 0.79 09.38.87 0.79 3 7 0.83.88 0.67 07.64.76 0.67 4.54.69 0.67 55 7 3.00.63 0.55 3.8.53 0.55 76.7.48 0.55 97 7 4 3.6.34 0.43 55.97.6 0.43 08.89.3 0.43 34 7 6 3.33.0 0.3 97 3.4 0.96 0.3 50 3.04 0.93 0.3 76 8 8.70. 0.83 09.48.04 0.83 09.38.96 0.83 3 8 0.83.00 0.7 07.64.86 0.7 4.54.79 0.7 55 8 3.00.75 0.59 3.8.64 0.59 76.7.58 0.59 97 8 4 3.6.47 0.47 55.97.38 0.47 08.89.34 0.47 34 8 6 3.33.5 0.35 97 3.4.08 0.35 50 3.04.05 0.35 76 9 8.70.33 0.87 09.48.4 0.87 09.38.06 0.87 3 9 0.83. 0.75 07.64.97 0.75 4.54.90 0.75 55 9 3.00.87 0.63 3.8.75 0.63 76.7.69 0.63 97 9 4 3.6.60 0.5 55.97.50 0.5 08.89.46 0.5 34 9 6 3.33.8 0.39 97 3.4. 0.39 50 3.04.7 0.39 76 30 8.70.44 0.9 09.48.4 0.9 09.38.5 0.9 3 30 0.83. 0.79 07.64.07 0.79 4.54.00 0.79 55 30 3.00.99 0.67 3.8.87 0.67 76.7.80 0.67 97 30 4 3.6.7 0.55 55.97.6 0.55 08.89.57 0.55 34 30 6 3.33.4 0.43 97 3.4.33 0.43 50 3.04.9 0.43 76 3 8.70.55 0.95 09.48.34 0.95 09.38.5 0.95 3 3 0.83.34 0.83 07.64.8 0.83 4.54.0 0.83 55 3 3.00. 0.7 3.8.98 0.7 76.7.9 0.7 97 3 4 3.6.85 0.59 55.97.74 0.59 08.89.69 0.59 34 3 6 3.33.55 0.47 97 3.4.46 0.47 50 3.04.4 0.47 76 3 8.70.65 0.99 09.48.44 0.99 09.38.34 0.99 3 3 0.83.45 0.87 07.64.8 0.87 4.54.0 0.87 55 3 3.00.3 0.75 3.8.09 0.75 76.7.0 0.75 97 3 4 3.6.98 0.63 55.97.86 0.63 08.89.80 0.63 34 3 6 3.33.68 0.5 97 3.4.58 0.5 50 3.04.53 0.5 76 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 5

PERFORMNCE DT COOL operation (30V) MSC-C35VB - MSC-G35VB - (Single : Room ) : MUX-473VB - E CPCITY : 3.4(kW) SHF : 0.77 INPUT : 0(W) OUTDOOR DB(:) INDOOR INDOOR 5 7 30 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 4.00.37 0.59 976 3.83.7 0.59 05 3.67.8 0.59 074 3.54.0 0.59 0 4.7.97 0.47 05 4.00.89 0.47 086 3.88.83 0.47 0 3.74.77 0.47 59 8 4.00.53 0.63 976 3.83.4 0.63 05 3.67.3 0.63 074 3.54.4 0.63 0 4.7.4 0.5 05 4.00.05 0.5 086 3.88.99 0.5 0 3.74.9 0.5 59 4.34.70 0.39 06 4.8.64 0.39 9 4.08.60 0.39 59 3.9.54 0.39 08 3 8 4.00.69 0.67 976 3.83.57 0.67 05 3.67.47 0.67 074 3.54.38 0.67 3 0 4.7.30 0.55 05 4.00. 0.55 086 3.88.4 0.55 0 3.74.07 0.55 59 3 4.34.88 0.43 06 4.8.8 0.43 9 4.08.77 0.43 59 3.9.69 0.43 08 4 8 4.00.85 0.7 976 3.83.73 0.7 05 3.67.6 0.7 074 3.54.5 0.7 4 0 4.7.47 0.59 05 4.00.37 0.59 086 3.88.30 0.59 0 3.74. 0.59 59 4 4.34.05 0.47 06 4.8.98 0.47 9 4.08.93 0.47 59 3.9.85 0.47 08 4 4 4.56.6 0.35 0 4.39.55 0.35 7 4.8.5 0.35 08 4.5.46 0.35 69 5 8 4.00 3.0 0.75 976 3.83.88 0.75 05 3.67.77 0.75 074 3.54.66 0.75 5 0 4.7.64 0.63 05 4.00.53 0.63 086 3.88.45 0.63 0 3.74.37 0.63 59 5 4.34. 0.5 06 4.8.5 0.5 9 4.08.09 0.5 59 3.9.0 0.5 08 5 4 4.56.79 0.39 0 4.39.7 0.39 7 4.8.68 0.39 08 4.5.63 0.39 69 6 8 4.00 3.7 0.79 976 3.83 3.03 0.79 05 3.67.9 0.79 074 3.54.80 0.79 6 0 4.7.80 0.67 05 4.00.69 0.67 086 3.88.6 0.67 0 3.74.5 0.67 59 6 4.34.40 0.55 06 4.8.3 0.55 9 4.08.6 0.55 59 3.9.6 0.55 08 6 4 4.56.97 0.43 0 4.39.90 0.43 7 4.8.85 0.43 08 4.5.80 0.43 69 6 6 4.69.47 0.3 7 4.56.43 0.3 3 4.49.40 0.3 69 4.35.36 0.3 305 7 8 4.00 3.33 0.83 976 3.83 3.9 0.83 05 3.67 3.06 0.83 074 3.54.95 0.83 7 0 4.7.97 0.7 05 4.00.85 0.7 086 3.88.76 0.7 0 3.74.67 0.7 59 7 4.34.57 0.59 06 4.8.48 0.59 9 4.08.4 0.59 59 3.9.3 0.59 08 7 4 4.56.5 0.47 0 4.39.07 0.47 7 4.8.03 0.47 08 4.5.96 0.47 69 7 6 4.69.66 0.35 7 4.56.6 0.35 3 4.49.58 0.35 69 4.35.54 0.35 305 8 8 4.00 3.49 0.87 976 3.83 3.34 0.87 05 3.67 3. 0.87 074 3.54 3.09 0.87 8 0 4.7 3.4 0.75 05 4.00 3.0 0.75 086 3.88.9 0.75 0 3.74.8 0.75 59 8 4.34.74 0.63 06 4.8.65 0.63 9 4.08.58 0.63 59 3.9.48 0.63 08 8 4 4.56.34 0.5 0 4.39.5 0.5 7 4.8.0 0.5 08 4.5.3 0.5 69 8 6 4.69.84 0.39 7 4.56.79 0.39 3 4.49.76 0.39 69 4.35.7 0.39 305 9 8 4.00 3.65 0.9 976 3.83 3.49 0.9 05 3.67 3.35 0.9 074 3.54 3.3 0.9 9 0 4.7 3.30 0.79 05 4.00 3.7 0.79 086 3.88 3.07 0.79 0 3.74.97 0.79 59 9 4.34.9 0.67 06 4.8.8 0.67 9 4.08.75 0.67 59 3.9.63 0.67 08 9 4 4.56.5 0.55 0 4.39.43 0.55 7 4.8.37 0.55 08 4.5.9 0.55 69 9 6 4.69.03 0.43 7 4.56.97 0.43 3 4.49.94 0.43 69 4.35.88 0.43 305 30 8 4.00 3.8 0.95 976 3.83 3.65 0.95 05 3.67 3.50 0.95 074 3.54 3.37 0.95 30 0 4.7 3.47 0.83 05 4.00 3.33 0.83 086 3.88 3.3 0.83 0 3.74 3. 0.83 59 30 4.34 3.09 0.7 06 4.8.98 0.7 9 4.08.9 0.7 59 3.9.79 0.7 08 30 4 4.56.70 0.59 0 4.39.60 0.59 7 4.8.54 0.59 08 4.5.46 0.59 69 30 6 4.69. 0.47 7 4.56.5 0.47 3 4.49. 0.47 69 4.35.06 0.47 305 3 8 4.00 3.97 0.99 976 3.83 3.80 0.99 05 3.67 3.65 0.99 074 3.54 3.5 0.99 3 0 4.7 3.64 0.87 05 4.00 3.49 0.87 086 3.88 3.38 0.87 0 3.74 3.7 0.87 59 3 4.34 3.6 0.75 06 4.8 3.5 0.75 9 4.08 3.07 0.75 59 3.9.94 0.75 08 3 4 4.56.88 0.63 0 4.39.78 0.63 7 4.8.7 0.63 08 4.5.63 0.63 69 3 6 4.69.4 0.5 7 4.56.34 0.5 3 4.49.30 0.5 69 4.35.3 0.5 305 3 8 4.00 4.3.03 976 3.83 3.95.03 05 3.67 3.79.03 074 3.54 3.65.03 3 0 4.7 3.80 0.9 05 4.00 3.65 0.9 086 3.88 3.54 0.9 0 3.74 3.4 0.9 59 3 4.34 3.44 0.79 06 4.8 3.3 0.79 9 4.08 3.4 0.79 59 3.9 3.0 0.79 08 3 4 4.56 3.07 0.67 0 4.39.95 0.67 7 4.8.88 0.67 08 4.5.79 0.67 69 3 6 4.69.59 0.55 7 4.56.5 0.55 3 4.49.48 0.55 69 4.35.4 0.55 305 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 53

PERFORMNCE DT COOL operation (30V) MSC-C35VB - MSC-G35VB - (Single : Room ) : MUX-473VB - E CPCITY : 3.4(kW) SHF : 0.77 INPUT : 0(W) OUTDOOR DB(:) INDOOR INDOOR 35 40 43 DB(:) WB(:) Q SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT 8 3.33.98 0.59 96 3.06.8 0.59 69.94.74 0.59 93 0 3.50.66 0.47 44 3.6.54 0.47 305 3.5.49 0.47 34 8 3.33. 0.63 96 3.06.94 0.63 69.94.86 0.63 93 0 3.50.80 0.5 44 3.6.67 0.5 305 3.5.6 0.5 34 3.7.46 0.39 93 3.47.36 0.39 366 3.35.3 0.39 39 3 8 3.33.4 0.67 96 3.06.06 0.67 69.94.98 0.67 93 3 0 3.50.94 0.55 44 3.6.80 0.55 305 3.5.74 0.55 34 3 3.7.60 0.43 93 3.47.50 0.43 366 3.35.45 0.43 39 4 8 3.33.38 0.7 96 3.06.8 0.7 69.94.0 0.7 93 4 0 3.50.08 0.59 44 3.6.94 0.59 305 3.5.86 0.59 34 4 3.7.75 0.47 93 3.47.64 0.47 366 3.35.58 0.47 39 4 4 3.9.38 0.35 34 3.67.30 0.35 403 3.57.6 0.35 434 5 8 3.33.5 0.75 96 3.06.30 0.75 69.94. 0.75 93 5 0 3.50. 0.63 44 3.6.07 0.63 305 3.5.99 0.63 34 5 3.7.90 0.5 93 3.47.78 0.5 366 3.35.7 0.5 39 5 4 3.9.54 0.39 34 3.67.44 0.39 403 3.57.40 0.39 434 6 8 3.33.64 0.79 96 3.06.43 0.79 69.94.33 0.79 93 6 0 3.50.36 0.67 44 3.6.0 0.67 305 3.5. 0.67 34 6 3.7.05 0.55 93 3.47.9 0.55 366 3.35.85 0.55 39 6 4 3.9.69 0.43 34 3.67.59 0.43 403 3.57.55 0.43 434 6 6 4..9 0.3 39 3.88. 0.3 45 3.76.8 0.3 48 7 8 3.33.78 0.83 96 3.06.55 0.83 69.94.45 0.83 93 7 0 3.50.50 0.7 44 3.6.33 0.7 305 3.5.4 0.7 34 7 3.7.0 0.59 93 3.47.06 0.59 366 3.35.99 0.59 39 7 4 3.9.85 0.47 34 3.67.74 0.47 403 3.57.69 0.47 434 7 6 4..45 0.35 39 3.88.37 0.35 45 3.76.33 0.35 48 8 8 3.33.9 0.87 96 3.06.67 0.87 69.94.57 0.87 93 8 0 3.50.64 0.75 44 3.6.46 0.75 305 3.5.37 0.75 34 8 3.7.35 0.63 93 3.47.0 0.63 366 3.35. 0.63 39 8 4 3.9.0 0.5 34 3.67.88 0.5 403 3.57.83 0.5 434 8 6 4..6 0.39 39 3.88.5 0.39 45 3.76.48 0.39 48 9 8 3.33 3.04 0.9 96 3.06.79 0.9 69.94.69 0.9 93 9 0 3.50.78 0.79 44 3.6.59 0.79 305 3.5.49 0.79 34 9 3.7.49 0.67 93 3.47.33 0.67 366 3.35.5 0.67 39 9 4 3.9.6 0.55 34 3.67.03 0.55 403 3.57.97 0.55 434 9 6 4..78 0.43 39 3.88.68 0.43 45 3.76.63 0.43 48 30 8 3.33 3.8 0.95 96 3.06.9 0.95 69.94.80 0.95 93 30 0 3.50.9 0.83 44 3.6.7 0.83 305 3.5.6 0.83 34 30 3.7.64 0.7 93 3.47.47 0.7 366 3.35.39 0.7 39 30 4 3.9.3 0.59 34 3.67.8 0.59 403 3.57. 0.59 434 30 6 4..95 0.47 39 3.88.83 0.47 45 3.76.78 0.47 48 3 8 3.33 3.3 0.99 96 3.06 3.04 0.99 69.94.9 0.99 93 3 0 3.50 3.06 0.87 44 3.6.85 0.87 305 3.5.75 0.87 34 3 3.7.79 0.75 93 3.47.6 0.75 366 3.35.5 0.75 39 3 4 3.9.48 0.63 34 3.67.3 0.63 403 3.57.6 0.63 434 3 6 4.. 0.5 39 3.88.99 0.5 45 3.76.93 0.5 48 3 8 3.33 3.44.03 96 3.06 3.6.03 69.94 3.04.03 93 3 0 3.50 3.0 0.9 44 3.6.98 0.9 305 3.5.87 0.9 34 3 3.7.94 0.79 93 3.47.75 0.79 366 3.35.66 0.79 39 3 4 3.9.63 0.67 34 3.67.47 0.67 403 3.57.40 0.67 434 3 6 4..8 0.55 39 3.88.4 0.55 45 3.76.08 0.55 48 NOTE Q :Total capacity (kw) SHF :Sensible heat factor DB :Dry-bulb temperature SHC :Sensible heat capacity (kw) INPUT :Total power input (W) WB :Wet-bulb temperature 54

0 CTUTOR CTROL OUTDOOR UNIT CTUTOR CTROL MUX-8VB - E MUX-59VB - E MUX-70VB - E CTUTOR OUTDOOR FN MOTOR SOLENOID VLVE CTUTOR OUTDOOR FN MOTOR SOLENOID VLVE MC MF R (BLNCE) R R MC MC MF6 R3 R4 RB INDOOR UNIT (CLOSE) (OPEN) (OPEN) (CLOSE) (OPEN) (CLOSE) MUX-360VB - E MUX-363VB - E INDOOR UNIT (OPEN) (CLOSE) (OPEN) (CLOSE) (CLOSE) (OPEN) NY UNIT B B C NY UNIT means that the indoor unit is not related to the control of actuator. CTUTOR COMPRE- SSOR COMPRE- SSOR COMPRE- SSOR COMPRE- SSOR OUTDOOR FN MOTOR MUX-473VB - E CTUTOR OUTDOOR FN MOTOR SOLENOID VLVE MC MC MF6 MC MC MF6 R R R3 R4 R INDOOR UNIT INDOOR UNIT (OPEN) (CLOSE) (OPEN) (CLOSE) (OPEN) (CLOSE) (OPEN) (CLOSE) (CLOSE) (BLNCE) (OPEN) RB (CLOSE) (BLNCE) (OPEN) NY UNIT B C B D NY UNIT 55

TROUBLESHOOTING MUX-8VB - E MUX-363VB - E MUX-59VB - E MUX-70VB - E MUX-360VB - MUX-473VB - E -. Cautions on troubleshooting. Before troubleshooting, check the following: ) Check the power supply voltage. ) Check the indoor/outdoor connecting wire for mis-wiring.. Take care the following during servicing. ) Before servicing the air conditioner, be sure to turn off the main unit first with the remote controller, and then after confirming the horizontal vane is closed, turn off the breaker and / or disconnect the power plug. ) Be sure to turn the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board. 3) When removing the electrical parts, be careful to the residual voltage of smoothing capacitor. 4) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components. 5) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires. Lead wiring Housing point 3. Troubleshooting procedure ) First, check if the OPERTI INDICTOR lamp on the indoor unit is flashing on and off to indicate an abnormality. To make sure, check how many times the abnormality indication is flashing on and off before starting service work. ) Before servicing check that the connector and terminal are connected properly. 3) If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the components for bursting and discoloration. 4) When troubleshooting, refer to -. 56

-. Instruction of troubleshooting Start Indoor unit operates. Outdoor unit doesn't operate. Indoor unit operates. Outdoor unit doesn't operate normally. Indoor unit doesn't receive the signal from remote controller. OPERTI INDICTOR lamp on the indoor unit is flashing on and off. Indoor unit operates. But indoor unit doesn't blow out cool air. Outdoor unit operates in only Test Run operation. Outdoor unit doesn't operate even in Test Run operation. Outdoor unit doesn't stop even if indoor unit stops. Indoor unit operates, when the EMERGENCY OPERTI switch is pressed. Indoor unit doesn't operate, when the EMERGENCY OPERTI switch is pressed. Check room temperature thermistor. Refer to "Test point diagram and voltage". Refer to -4. "Check of outdoor unit". Refer to -4.B "Check of outdoor unit". Refer to "Check of remote controller and receiver P.C. board".. Check indoor / outdoor connecting wire.. Refer to "Check of indoor electronic control P.C. board". Refer to -4.D "Check of indoor / outdoor units' connection and outdoor unit". Flash on and off at 0.5-second intervals Cause: Wrong setting of switch (SW-) on the electronic control P.C. board. -time flash Cause: Indoor unit Trouble of room temperature/ indoor coil thermistor 3-time flash Cause: Indoor unit Trouble of indoor fan motor s for indoor unit MSC-C type, refer to service manual OB393. s for indoor unit MSC-G type, refer to service manual OB385. Refer to -4.C "Check of MU & MUX TYPE / MUH & MXZ TYPE SWITCH OVER " (When outdoor unit doesn't work.). Check room temperature thermistor and indoor coil thermistor. Refer to "Test point diagram and voltage". Refer to "Check of indoor fan motor". 57

-3. Trouble criterion of main parts MUX-8VB - E MUX-59VB - E MUX-360VB - E MUX-363VB - MUX-70VB - MUX-473VB - E Part name Check method and criterion Measure the resistance between the terminals with a tester. (Coil wiring temperature-0 C ~ 40 C) E Figure Compressor (MC, MC, MC) INNER PROTECTOR 50 C OPEN 90 C CLOSE C-R C-S C-R C-S Normal MUX-8VB MUX-59VB, MUX-363VB MUX-360VB RN09VHSHT RN45VHSHT RN09VHSHT RN099VHSHT RN5VHSHT 3.4 ~ 4.8Ω.4 ~.63Ω 3.4 ~ 4.8Ω.99 ~ 3.67Ω.5 ~ 3.09Ω 5.4 ~ 6.63Ω 3.35 ~ 4.Ω 5.4 ~ 6.63Ω 4.0 ~ 4.39Ω 5.04 ~ 6.8Ω RN45VHSHT.4 ~.63Ω 3.35 ~ 4.Ω MUX-70VB RN45VHSHT.4 ~.63Ω 3.35 ~ 4.Ω Normal RN45VHSHT.4 ~.63Ω 3.35 ~ 4.Ω MUX-473VB RN5VHSHT.5 ~ 3.09Ω 5.04 ~ 6.8Ω bnormal Open or short-circuit bnormal Open or short-circuit P Outdoor fan motor (MF, MF6) INNER FUSE MUX-8VB 45 C OPEN Measure the resistance between the terminals with a tester. (Coil wiring temperature -0 C ~ 40 C) Color of lead wire WHT-BLK BLK-RED MUX-8VB 96 ~ 4Ω 08 ~ 46Ω Normal MUX-59VB 79 ~ 98Ω 9 ~ 58Ω MUX-360VB 79 ~ 98Ω 9 ~ 58Ω bnormal Open or short-circuit MUX-8VB FUSE BLK RED WHT INNER PROTECTOR MUX-59/360/ 363/70/ 473VB 45i8 C OPEN Solenoid coil R, R, RB, R, R, R3, R4 Measure the resistance between the terminals with a tester. (Coil wiring temperature -0 C ~ 40 C) WHT-BLK BLK-RED MUX-363VB 79 ~ 98Ω 9 ~ 58Ω Normal MUX-70VB 79 ~ 98Ω 9 ~ 58Ω MUX-473VB 69 ~ 85Ω 70 ~ 86Ω bnormal Open or short-circuit Measure the resistance with a tester. (Part temperature -0 C ~ 40 C) Normal bnormal 40 ~ 730Ω Open or short-circuit MUX-59/360/ 363/70/ 473VB P BLK RED WHT P INNER PROTECTOR 58

-4.Troubleshooting flow Compressor and / or outdoor fan doesn t operate. Check of outdoor unit Start Is there 30V C between L - N on the TB of outdoor unit? Yes Press the EMERGENCY OPERTI switch of all indoor units. No Check the power supply and connecting wire. 3 minutes later, is there V DC between - on the all terminal blocks of outdoor unit? Yes No Is there V DC between - on the terminal block of each indoor unit? Yes Check and rectify the connecting wire of indoor and outdoor unit. No Check the indoor unit. Is there 0~5V DC between JP0 DCV and JP9 GND on outdoor control P.C. board? No Turn the power supply. Yes Is fuse(f6) on the outdoor control P.C. board broken? No Replace the outdoor control P.C. board. Yes 59/70VB MUX-360/363/ 473VB Disconnect connector of outdoor fan motor CN9 and outdoor fan capacitor C6. Measure resistance on all the solenoid coils. Is resistance 0"? No Yes Replace the solenoid coil. Is the resistance 0" or between the lead wire WHT and BLK of outdoor fan motor, or between the lead wire RED and BLK of outdoor fan motor? (Refer to -3.) Yes Replace the outdoor fan motor and fuse(f6). No Short both terminal of fuse(f6). Is the resistance 0" between No the fuse(f6) and the terminal of CN903? Yes Replace the fuse(f6). Replace the outdoor control P.C. board. Fan motor doesn't operate. Compressor doesn't operate. Turn the power supply to outdoor unit. Does outdoor control P.C. board connect with outdoor fan capacitor C6? Yes Disconnect connector of outdoor fan motor CN9 and outdoor fan capacitor C6. Is the resistance 0" or between the lead wire WHT and BLK of outdoor fan motor, or between the lead wire RED and BLK of outdoor fan motor? (Refer to -3.) Yes Replace the outdoor fan motor. No No Connect the outdoor control P.C. board with outdoor fan capacitor C6. Replace the outdoor control P.C. board. Turn the power supply to outdoor unit. Disconnect connecting wire of X5 and X5 from outdoor control P.C. board. Insulate terminal of connecting wires to prevent contact of other parts. Turn the power supply to outdoor unit. Press the EMERGENCY OPERTI switch of all indoor unit. 3 minutes later, is the resistance 0" between the terminal 3 and 4 of X5 on outdoor control P.C. board, and between the terminal 3 and 4 of X5 on outdoor control P.C. board? Yes Turn the power supply to outdoor unit. Is the resistance 0" or between the terminal C and R of MC, and between the terminal C and S of MC? (Refer to -3.) Yes Replace the compressor MC. No No Is the resistance 0" or between the terminal C and R of MC, and between the terminal C and S of MC? (Refer to -3.) Yes Replace the compressor MC. Turn the power supply to outdoor unit. Replace the outdoor control P.C. board. No Check and rectify the connecting wire of terminal and compressor. 59

Compressor and / or outdoor fan doesn t stop. B Check of outdoor unit Start Turn the power supply. fter minute, turn power supply again. Does compressor or outdoor fan motor stop? Yes OK No Is there V DC between on the outdoor terminal block (TB or TB3)? Yes Replace the indoor electoronic control P.C. board. No Replace the outdoor control P.C. board. When OPERTI INDICTOR lamp flashes 0.5-second intervals. Outdoor unit doesn t operate. C Check of MU & MUX TYPE / MUH & MXZ TYPE SWITCH OVER Start Turn the power supply (indoor / outdoor unit). Set switch (SW-) on the indoor electronic control P.C. board to MUX type. w Yes Does the unit operate? No Refer to the "Instruction of troubleshooting." OK w Set the switch (SW-) on indoor electronic control P.C. board to MUX type, when the outdoor unit is MUX type. If the setting is MUH or MXZ type, the unit does not work. Refer to MU & MUX TYPE / MUH& MXZ TYPE SWITCH OVER on service manual OB393 or OB385. 60

Cool air does not blow out although indoor unit is operating. D Check of indoor/outdoor units connection and outdoor unit w In case of troubleshooting, be sure to operate indoor unit by emergency operation switch. Start Turn the power supply, and operate all the indoor units at a time. Do they perform the cooling operation? Yes Operate the indoor unit one by one, and measure the voltage between and of outdoor terminal block for each indoor unit. Match the signs of terminal block whose voltage is V DC and pipe of indoor/ outdoor units' connection. w. w. MUX-8/360/363/473VB If the pipe of indoor unit that does not operate is cooled though the combination of pipe and connecting wire is correct, check the solenoid coil. Refer to 7.WIRING DIGRM. No Turn the power supply. Remove solenoid coil's connector that corresponds to the indoor unit, which does not blow out cool air. Then, measure the resistance of solenoid coil. Do the resistance value normal? No (Refer to -3.) Yes Reconnect solenoid coil's connector. Then turn the main power on and operate the indoor unit that does not blow out cool air. Measure the voltage of solenoid coil's connector that corresponds to the indoor unit, which is operated. Replace the solenoid coil. Is voltage 30V? Yes No MUX-8VB Check wiring of outdoor unit and relay. (Refer to page 6.) Model Indoor unit Terminal block Connector for solenoid coil control OK MUX-59/360/363/ 70/473VB Replace the outdoor control P.C. board. MUX-8VB MUX-360VB MUX-363VB MUX-473VB B B C B C D TB TB TB3 TB4 TB TB3 TB4 TB5 R R R3-CN85 R4-CN86 R-CN83 R-CN84 R3-CN85 R4-CN86 R RB-CN8 R-CN8 RB-CN8 6

-5. Test point diagram and voltage MUX-59VB - E MUX-360VB - E MUX-363VB - E MUX-70VB - E MUX-473VB - E Outdoor control P.C. board To fan motor To fan capacitor W From indoor unit V DC +,3- W From indoor unit B V DC +,3- W From indoor unit C V DC +,3- W From indoor unit D V DC +,3- To fan capacitor To indoor unit B Solenoid coil R To indoor unit Solenoid coil R To indoor unit C Solenoid coil R3 To indoor unit D Solenoid coil R4 To solenoid coil R To solenoid coil RB To compressor MC To terminal block To compressor MC To terminal block Fuse 50V C 3.5 Power supply input 30V C Surge absorber (NR6) + W In case of MUX-473VB } V DC 6

DISSSEMBLY INSTRUCTIS <"Terminal with locking mechanism" Detaching points> The terminal which has the locking mechanism can be detached as shown below. There are two types ( Refer to () and ()) of the terminal with locking mechanism. The terminal without locking mechanism can be detached by pulling it out. Check the shape of the terminal before detaching. () Slide the sleeve and check if there is a locking lever or not. () The terminal with this connector has the locking mechanism. Sleeve Locking lever Slide the sleeve. Pull the terminal while pushing the locking lever. Connector Hold the sleeve, and pull out the terminal slowly. -. MUX-8VB - E OUTDOOR UNIT OPERTING PROCEDURE. Removing the cabinet () Remove the screws of the top panel. () Remove the screw of the service panel. (3) Remove the screws of the cabinet. (4) Remove the screws of the front panel and motor support. (5) Remove the service panel, and remove the screw from the insides. (6) Remove the top panel. (7) Remove the cabinet. Photo PHOTOS Screws of the front panel and motor support Screws of the top panel Screws of the service panel Photo 3 Relay panel Fuse (F6) Compressor capacitor (C) Fuse (F6) Terminal block (TB) Terminal block (TB) Screws of the cabinet Photo Screws of the top panel Screws of fixing relay panel Screw of fixing relay panel Terminal block (TB3) Outdoor fan capacitor (C) Relay (o) Relay (o) Surge absorber (DSR) Contactor (5C) Screws of the cabinet 63

OPERTING PROCEDURE PHOTOS. Removing the relay panel () Remove the service panel and the cabinet.(refer to.) () Remove the following connectors. Outdoor fan motor Solenoid coil (R, R, R) Photo 4 Screws of the outdoor fan motor Hook Lead wire Lead clamp Propeller Propeller nut Outdoor fan motor Outdoor fan motor connector Solenoid coil connector (R, R, R) 3. Removing the propeller and the outdoor fan motor () Remove the cabinet. (Refer to.) () Remove the propeller nut. (3) Remove the propeller. NOTE : Loose the propeller in the rotating direction for removal. When attaching the propeller, align the mark on the propeller and the motor shaft cut section. Set the propeller in position by using the cut on the shaft and the mark on the propeller. (4) Remove lead clamps and disconnect the outdoor fan motor connector. (5) Remove screws fixing the fan motor. (6) Remove the outdoor fan motor. 4. Removing the compressor () Remove the cabinet. (Refer to.) () Remove the relay panel. (3) Remove the soundproof felt. (4) Remove the terminal cover on the compressor. (5) Disconnect lead wires from the glass terminal of the compressor. (6) Recover gas from the refrigerant circuit. NOTE:Recover gas from the pipes until the pressure gauge shows 0 kg/cm (0 MPa). (7) Disconnect the welded part of the discharge pipe. (8) Disconnect the welded part of the suction pipe. (9) Remove nuts fixing the compressor. (0) Remove the compressor. Photo 5 Discharge pipe Glass terminal Compressor Screws of the solenoid coil (R) Screws of the compressor Screws of the solenoid coil (R) Screws of the solenoid coil (R) Suction pipe Terminal cover 64

-. MUX-59VB - E MUX-360VB - E MUX-363VB - E MUX-70VB - MUX-473VB - E OUTDOOR UNIT NOTE : These photos are MUX-360VB. Other models are almost the same as MUX-360VB. E OPERTING PROCEDURE PHOTOS.Removing the cabinet () Remove the screws of the service panel. () Remove the screws of the top panel. (3) Remove the service panel. (4) Remove the top panel. (5) Remove the screws of the front panel. (6) Remove the front panel. (7) Remove the screws of the back panel. (8) Remove the back panel. Photo Screws of the front panel Top panel Front panel Screws of the front panel Photo 3 Back panel Photo Screws of the top panel Service panel Screws of the service panel Screws of the back panel Screws of the front panel Screws of the back panel 65

OPERTING PROCEDURE. Removing the relay panel () Remove the cabinet. (Refer to.) () Disconnect the following connectors.. Outdoor fan motor. Only MUX-360VB and MUX-363VB Solenoid coil (RB, R3, R4). Only MUX-473VB Solenoid coil (R, RB, R, R, R3, R4) Photo 4 Screws of the outdoor fan motor Back panel Outdoor fan motor PHOTOS Solenoid coil connector (R, RB, R, R, R3, R4) Outdoor fan motor connector Screws of the relay panel Clamp Screws of the relay panel 3. Removing the propeller () Remove the cabinet. (Refer to.) () Remove the propeller nut. (3) Remove the propeller. NOTE : Loose the propeller in the rotating direction for removal. When attaching the propeller, align the mark on the propeller and the motor shaft cut section. Set the propeller in position by using the cut on the shaft and the mark on the propeller. Propeller Propeller nut 4. Removing the outdoor fan motor () Remove the cabinet. (Refer to.) () Remove the propeller. (Refer to 3.) (3) Remove the clamp of outdoor fan motor lead wire and disconnect the outdoor fan motor connector. (4) Remove the screws fixing the outdoor fan motor. (5) Remove the outdoor fan motor. 66

OPERTING PROCEDURE 5. Removing the compressor (, B) () Remove the cabinet. (Refer to.) () Remove the relay panel. (3) Remove the soundproof felt. (4) Remove the terminal cover on the compressor. (5) Disconnect lead wires from the compressor. (6) Recover gas from the refrigerant circuit. NOTE:Recover gas from the pipes until the pressure gauge shows 0 kg/cm (0 MPa). (7) Disconnect the welded part of the discharge pipe. (8) Disconnect the welded part of the suction pipe. (9) Remove nuts fixing the compressor. (0) Remove the compressor. Photo 5 Suction pipe PHOTOS Terminal cover 6. Removing the compressor (C) () Remove the cabinet. (Refer to.) () Remove the relay panel. (Refer to.) (3) Remove the screws fixing back panel. (4) Remove the back panel. (5) Remove the soundproof felt. (6) Remove the terminal cover on the compressor. (7) Disconnect lead wires from the compressor. (8) Recover gas from the refrigerant circuit. NOTE:Recover gas from the pipes until the pressure gauge shows 0 kg/cm (0 MPa). (9) Disconnect the welded part of the discharge pipe. (0) Disconnect the welded part of the suction pipe. () Remove nuts fixing the compressor. () Remove the compressor. Discharge pipe Soundproof felt Terminal cover 67