The Healthcare Environment Update

Similar documents
EXPLORING LIFE SAFETY COMPLIANCE FOR HEALTH CARE

2016 Joint Commission Update

THE HEALTHCARE ENVIRONMENT UPDATE. Anne M. Guglielmo, Engineer Engineering Department The Joint Commission. Copyright, The Joint Commission

2017 CHALLENGING STANDARDS 2018 NEW ELEMENTS OF PERFORMANCE HOSPITAL ENVIRONMENT OF CARE AND

ASHE Advocacy Team. Q4 ASHE Advocacy Liaison Webinar 12/7/16 12/7/16. Tim Adams, FASHE, CHFM, CHC Director of Leadership Development

Top 8 Findings & SAFER Matrix for the 2017 ACE Summit & Expo

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

2018 Joint Commission Standards What s New in the EC/LS/UM GASHE Annual March Meeting Lake Blackshear Resort

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

2017 Accreditation Updates

Michigan Society for Healthcare Engineering Environment of Care, Life Safety, and Emergency Management Update

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Compliance w/ the 2012 Life Safety Code

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

Agency for Health Care Administration

THE HEALTHCARE ENVIRONMENT UPDATE. George Mills, Director Engineering Department The Joint Commission. Copyright, The Joint Commission

The Surveyor s Perspective. Understanding How The Joint Commission Surveyors Conducts Surveys

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

Agency for Health Care Administration

Standards Revisions Related to Life Safety Code Update

NFPA 99 for Facility Managers

FHCA 2014 Annual Conference & Trade Show

The Joint Commission: 2018 Update

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters

Measures (ILSM) Process

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

10/25/2018. Facilitators. Emergency Preparedness &Life Safety Code for Administrators. Participant Guide

TOPICS IN CODE ENFORCEMENT

Center for Clinical Standards and Quality /Survey & Certification Group

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Life Safety Code Comparison

Agency for Health Care Administration

Written Fire Safety Plans

Statement of Conditions

Agency for Health Care Administration

Health Care Engineers Fire & Life Safety Boot Camp

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

UPDATE. The Healthcare Environment. George Mills, Sr. Engineer Standard Interpretation Group The Joint Commission. Copyright, The Joint Commission

K SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER

Iowa State Fire Marshal

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

Agency for Health Care Administration

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

ASCs & LSC. Alice Epstein, DFASHRM, FNAHQ

Agency for Health Care Administration

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Are there any policies regarding outlets that contain USB ports?

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

NFPA 101 Life Safety Code Culture change 2012

Developing a Healthcare Facility Fire Door Inspection Program

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

California Society for Healthcare Engineering, Inc. Environment of Care, Life Safety, and Emergency Management Update 2017

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

Standards Revisions Related to Life Safety Code Update

EC 5.10 FIRE PREVENTION MANAGEMENT

Agency for Health Care Administration

The Physical Environment Portal: Module 5, LS Leadership

HFAP Acute Care Hospital Manual Crosswalk of Standards against 2014 Standards

Agency for Health Care Administration

Public Safety in the Healthcare Facility

TIPS FOR BETTER JOINT COMMISSION SURVEYS

Review of Revisions to NFPA 1, 2015 Edition

Emergency Planning for Institutional Facilities

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Agency for Health Care Administration

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Facility Sourcing Practices and Joint Commission Update

27th Annual AHCA Seminar

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

2000 to 2012 Hospital K-tag crosswalk matrix for hospitals 2000 Tag #

INSPECTOR I SKILLS ADMINISTRATION

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

WHAT S NEW IN NFPA

ICC CODE CORNER 2015 International Fire Code

WHAT S NEW IN NFPA

Candy Easterling K-063. Adequate and Reliable Water Supply for the Sprinkler System. CITY WATER or WATER TANK for Sprinkler System

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

David Stymiest, PE, CHFM, CHSP, FASHE cell Copyright 2014, Smith Seckman Reid, Inc.; All rights reserved

Transcription:

2017 The Healthcare Environment Update John Maurer, SASHE, CHFM, CHSP Engineering Department The Joint Commission Engineering Department 2017-1

Most Cited Standards Standard 2015 % Noncompliance 2016 % Noncompliance 2016 Rank EC.02.06.01 62% 68% 1 IC.02.02.01 59% 60% 2 EC.02.05.01 58% 57% 3 LS.02.01.35 46% 49% 4 LS.02.01.30 50% 51% 5 LS.02.01.20 51% 46% 6 LS.02.01.10 45% 50% 7 EC.02.02.01 39% 48% 8 PC.02.01.03 40% 47% 9 RC.01.01.01 47% 42% 10 Engineering Department 2017-2

EC.02.06.01 EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Cylinder management 2017 Scoring at EC.02.05.09 EP 6 Storage Secured, labeled, etc. Segregation Full vs. Empty NFPA 99 2012 Chapter 5 Gas and Vacuum Systems Chapter 11 Gas Equipment NEW! Engineering Department 2017-3

EC.02.06.01 EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Outside Cylinder Management 2017 Scoring at EC.02.05.09 EP 7 Previously scored at EC.02.01.01 EP 5 Secured Protected for the elements (sun, snow, water, etc.) Protective shipping mesh or wraps NFPA 99 2012 Chapter 5 Gas and Vacuum Systems Chapter 11 Gas Equipment NEW! Engineering Department 2017-4

EC.02.06.01 EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Ligature/self harm risks (i.e. BHC) Current Risk Assessment Best Practice Guidelines Design Guide for the Built Environment of Behavioral Health Facilities Engineering Department 2017-5

Ligature Risks Psychiatric Settings Process: self-harm risks identified Determination if previously identified Evaluate existing plans for removing the risks Evaluate the environmental risk assessment process See also Joint Commission Online, March 1, 2017 www.jointcommission.org/issues Engineering Department 2017-6

Ligature Risks Psychiatric Settings Further evaluation Plans and policies on mitigation of harm posed by risks while removal occurs Adequacy of staffing patterns to the mitigation plans The patient suicide risk assessment process See also Joint Commission Online, March 1, 2017 www.jointcommission.org/issues Engineering Department 2017-7

Ligature Risks Psychiatric Settings Further evaluation Policies and practices related to actions needed for patients identified at risk Policies and processes of ensuring staff awareness of a patient s level of risk The organization s internal processes for improvement, including: The history of patient safety events and the process for root cause analysis of these events The organization s process for monitoring its compliance with its policies Actions taken when noncompliance was identified Engineering Department 2017-8

IMPACT OF CMS ADOPTION OF THE 2012 LIFE SAFETY CODE (NFPA 101-2012) 2012 HEALTH CARE FACILITIES (NFPA 99-2012) Engineering Department 2017-9

Standards NFPA 101-2012 The NFPA created a series of codes to provide guidance in building and maintaining buildings CMS adopted this body of codes, incorporating them into their COP as K-Tags The Joint Commission has also recognized the NFPA body of codes The Life Safety Chapter is based on NFPA 101-2012 In the Environment of Care several other NFPA codes are referenced, including: NFPA 10-2010, Standard for Portable Fire Extinguishers NFPA 25-2011, Standard for Water-based Systems ITM Activity NFPA 72-2010, Fire Alarm Code NFPA 99-2012, Health Care Facilities Code Engineering Department 2017-10

Engineering Department 2017-11 Copyright, The Joint Commission

New vs. Existing Occupancies New Health Care Buildings, additions, renovations or changes in occupancy whose final plans were approved by the local AHJ after July 5 th, 2016 Use Chapter 18 of the NFPA 101-2012 Life Safety Code Existing Health Care Buildings, additions, renovations or changes in occupancy whose final plans were approved by the local Authority Having Jurisdiction (AHJ) prior to July 5 th, 2016 Use Chapter 19 of the NFPA 101-2012 Life Safety Code Engineering Department 2017-12

CMS Information Tuesday May, 3, 2016 CMS issued the final rule adopting the 2012 Life Safety Code. The rule is effective July 5, 2016 This rule also adopts most of NFPA 99, 2012 edition. Chapters 7, 8, 12, 13 are excluded from the adoption Survey for compliance November 1, 2016 Emergency Management Published September 8, 2016 Implementation by November 15, 2017 Standards under review Engineering Department 2017-13

NFPA 99-2012: Risk-based Chapter 4: Building systems shall be designed to meet Category 1-4 Category 1: Failure likely to cause major injury of death Category 2: Failure likely to cause minor injury Category 3: Failure to cause discomfort Category 4: Failure with no impact to care Risk assessment Categories determined by organization s risk assessment procedure Chapters identify new vs. existing application Engineering Department 2017-14

NFPA 99-2012 Adoption Exclusions Chapter 7: IT and Communication Systems Chapter 8: Plumbing Chapter 12: Emergency Management Chapter 13: Security Management Engineering Department 2017-15

NFPA 99-2012 Adoption Exclusions CMS statement: As stated in the proposed rule, we will not be adopting Chapters 7, 8 and 13 because we have no authority to regulate these specific topics in health care facilities. Additionally, the content of Chapter 12, Emergency management, is already being addressed in a separate rule for emergency preparedness. Although, we have not adopted these chapters, providers may use these chapters for their individual facility needs. Source: Federal Register, Vol. 81, No. 86 Engineering Department 2017-16

CMS Adoption Issues Roller latches continue to be prohibited Corridor doors Doors protecting hazardous areas ASC that renders one or more incapable continue to be AHC Outpatient surgical departments There is a provision to allow CMS to waive specific provisions of the Life Safety Code for unreasonable hardship Hospitals may install ABHR provided the installation adequately protects against inappropriate access Engineering Department 2017-17

CMS Quote: While CMS does not directly enforce the Americans with Disabilities Act (ADA) it does expect compliance with the requirements as additional Federal requirements that facilities are required to follow. An example of this is corridor projections where the Life Safety Code (LSC) allows a noncontinuous projection to be no more than 6 inches from the corridor wall. Section 307 of the ADA Accessibility Guidelines for Buildings and Facilities requires that projections be not more than 4 inches from the corridor wall. Facilities are required to meet this more stringent requirement as set forth by the ADA. Engineering Department 2017-18

CMS Adoption Issues If the sprinkler system is shut down for 10 or more hours, a fire watch or evacuation of the building or affected portion of the building must occur Every sleeping room has outside door or window Windows in atrium walls are considered outside windows Exception: newborn nurseries and rooms intended for less than 24- hour stays (see NFPA 101-2006 18/19.3.8) In new buildings the fixed window sill height is to be no higher than 36 inches above the floor (with exceptions, see NFPA 101-2006 18/19.3.8.2) Required sprinkler protection of all high rises (>75 ft) Includes Chapter 43, Building Rehabilitation Engineering Department 2017-19

Impact to Standards - 2017 Environment of Care 149 1 = 148 + 13 = 161 31 modifications Life Safety Chapter 203 5 = 198 +21 = 219 32 modifications Engineering Department 2017-20

Environment of Care Chapter 2017

EC.02.02.01 EP 9 The hospital minimizes risks associated with selecting, handling, storing, transporting, using, and disposing of hazardous gases and vapors. Note: Hazardous gases and vapors include, but are not limited to, ethylene oxide and nitrous oxide gases; vapors generated by glutaraldehyde; cauterizing equipment, such as lasers; waste anesthetic gas disposal (WAGD); and laboratory rooftop exhaust. (For full text, refer to NFPA 99-2012: 9.3.8; 9.3.9) Engineering Department 2017-22

EC.02.03.05 EP 25 The hospital has written documentation of annual inspection and testing of door assemblies by individuals who can demonstrate knowledge and understanding of the operating components of the door being tested. Testing begins with a pre-test visual inspection; testing includes both sides of the opening. Note: For additional guidance on testing of door assemblies, see NFPA 101-2012: 7.2.1.5.10.1; 7.2.1.5.11; NFPA 80-2010: 4.8.4; 5.2.1; 5.2.3; 5.2.4; 5.2.6; 5.2.7; 6.3.1.7; NFPA 105-2010: 5.2.1. Engineering Department 2017-23

EC.02.05.01 EP 8 The hospital labels utility system controls to facilitate partial or complete emergency shutdowns. Note 1: Examples of utility system controls that should be labeled are utility source valves, utility system main switches and valves, and individual circuits in an electrical distribution panel. Engineering Department 2017-24

EC.02.05.01 EP 8 (cont.) Note 2: For example, the fire alarm system s circuit is clearly labeled as Fire Alarm Circuit; the disconnect method (that is, the circuit breaker) is marked in red; and access is restricted to authorized personnel. Information regarding the dedicated branch circuit for the fire alarm panel is located in the control unit. For additional guidance, see NFPA 101-2012: 18/19.3.4.1; 9.6.1.3; NFPA 72-2010: 10.5.5.2. Engineering Department 2017-25

EC.02.05.01 EP 18 Medical gas storage rooms and transfer and manifold rooms comply with NFPA 99-2012: 9.3.7. Ventilation Engineering Department 2017-26

EC.02.05.01 EP 19 The emergency power supply system s equipment and environment are maintained per manufacturers recommendations, including ambient temperature of at least 40 F; ventilation supply and exhaust; and water jacket temperature (when required). (For full text, refer to NFPA 99-2012: 9.3.10) Engineering Department 2017-27

EC.02.05.03 EP 10 The hospital provides emergency power within 10 seconds for the following: Emergency lighting at emergency generator locations. The hospital s emergency power system (EPS) has a remote manual stop station (with identifying label) to prevent inadvertent or unintentional operation. A remote annunciator (powered by storage battery) is located outside the EPS location. Note: For guidance in establishing a reliable emergency power system (that is, an essential electrical distribution system), refer to NFPA 99-2012: 6.4.1.1.6; 6.4.1.1.17; 6.4.2.2.3.3; NFPA 110-2010: 5.6.5.6; 7.3.1. Engineering Department 2017-28

EC.02.06.05 EP 2 When planning for demolition, construction, renovation, or general maintenance, the hospital conducts a preconstruction risk assessment for air quality requirements, infection control, utility requirements, noise, vibration, and other hazards that affect care, treatment, and services. Note: See LS.01.02.01 for information on fire safety procedures to implement during construction or renovation. Engineering Department 2017-29

EC.02.05.05 EP 1 When performing repairs or maintenance activities, the hospital has a process to manage risks associated with air-quality requirements; infection control; utility requirements; noise, odor, dust, vibration; and other hazards that affect care, treatment, or services for patients, staff, and visitors. Engineering Department 2017-30

Medical Equipment & Utilities Systems All scheduled maintenance activities for non-high-risk medical equipment and utility systems components in an alternative equipment maintenance (AEM) program inventory are to be completed at 100%. AEM frequency is determined by the organization AEM program. Engineering Department 2017-31

Medical Equipment Note 3 Update Scheduled maintenance activities for non-high-risk medical equipment in an alternative equipment maintenance (AEM) program may be deferred provided the completion rate is not less than 90% CMS response: Note allows for completion rate of 90% for AEM for non-high-risk medical equipment. CMS indicated that 100% of the maintenance has to be completed and that AEM is performed at a frequency defined by the organization s AEM program Engineering Department 2017-32

Life Safety Chapter 2017

LS.01.01.01 EP 2 In time frames defined by the hospital, the hospital performs a building assessment to determine compliance with the Life Safety chapter. Requires documentation of the policy Policy requires time frame Policy on how an assessment is completed Does not include review of results of assessment Engineering Department 2017-34

LS.01.01.01 EP 3 The hospital maintains current and accurate drawings denoting features of fire safety and related square footage. Fire safety features include the following: Areas of the building that are fully sprinklered (if the building is partially sprinklered) Locations of all hazardous storage areas Locations of all fire-rated barriers Locations of all smoke-rated barriers Sleeping and non-sleeping suite boundaries, including the size of the identified suites Locations of designated smoke compartments Locations of chutes and shafts Any approved equivalencies or waivers Engineering Department 2017-35

LS.01.01.01 EP 4 When the hospital plans to resolve a deficiency through a Survey-Related Plan for Improvement (SPFI), the hospital meets the 60-day time frame. Note 1: If the corrective action will exceed the 60-day time frame, the hospital must request a time-limited waiver within 30 days from the end of survey. Note 2: If there are alternative systems, methods, or devices considered equivalent, the hospital may submit an equivalency request using its Statement of Conditions (SOC). Note 3: For hospitals that use Joint Commission accreditation for deemed status purposes: if there are existing alternative systems, methods, or devices, the hospital may submit a waiver request using their Statement of Conditions (SOC). Note 4: For additional guidance on equivalencies, see NFPA 2012: 101:1.4.3 Engineering Department 2017-36

LS.01.01.01 EP 5 & 6 EP 5 For hospitals that use Joint Commission accreditation for deemed status purposes: The hospital maintains documentation of any inspections and approvals made by state or local fire control agencies. EP 6 The hospital does not remove or minimize an existing life safety feature when such feature is a requirement for new construction. Existing life safety features, if not required by the Life Safety Code, can be either maintained or removed. (For full text, refer to NFPA 101-2012: 4.6.12.2; 4.6.12.3) Engineering Department 2017-37

LS.02.01.34 EP 3 EP 3 The ceiling membrane is installed and maintained in a manner that permits activation of the smoke detection system. (For full text, refer to NFPA 101-2012: 18/19.3.4.1) Engineering Department 2017-38

LS.02.01.35 EP 5 Sprinkler heads are not damaged. They are also free from corrosion, foreign materials, and paint and have necessary escutcheon plates installed. (For full text, refer to NFPA 101-2012: 18.3.5.1; 19.3.5.3; 9.7.5; NFPA 25-2011: 5.2.1.1.1; 5.2.1.1.2; NFPA 13-2010: 6.2.6.2.2; 6.2.7.1) Engineering Department 2017-39

LS.02.01.35 EP 10 The travel distance from any point to the nearest portable fire extinguisher is 75 feet or less. Portable fire extinguishers have appropriate signage, are installed either in a cabinet or secured on a hanger made for the extinguisher, and are at least four inches off the floor. Those fire extinguishers that are 40 pounds or less are installed so the top is not more than 5 feet above the floor. (For full text, refer to NFPA 101-2012: 18/19.3.5.12; 9.7.4.1; NFPA 10-2010: 6.2.1.1; 6.1.3.3.1; 6.1.3.4; 6.1.3.8) Engineering Department 2017-40

LS.02.01.70 EP 1 Smoking is prohibited in any room, ward, or compartment where flammable liquids, combustible gases, or oxygen is used or stored; these areas have signs that read NO SMOKING or display the international symbol for no smoking. In facilities where smoking is prohibited and signs are prominently placed at all major entrances, secondary signs that prohibit smoking in hazardous areas are not required. (For full text, refer to NFPA 101-2012: 18/19.7.4) Note: The secondary sign exception is not applicable to medical gas storage areas. Engineering Department 2017-41

LS.02.01.70 EP 2 In areas where smoking is permitted, ashtrays are safely designed and made of noncombustible material. Metal containers with self-closing cover devices in which ashtrays can be emptied are readily available to all areas where smoking is permitted. (For full text, refer to NFPA 101-2012: 18/19.7.4) Engineering Department 2017-42

Department of Engineering 630-792-5900 George Mills, MBA, FASHE, CEM, CHFM, CHSP, Green Belt Director Andrea Browne, PhD., DABR Medical Physicist John Maurer, CHFM, CHSP, SASHE Engineer Herman McKenzie, MBA, CHSP Engineer Kathy Tolomeo, CHEM, CHSP Engineer James Woodson, P.E., CHFM Engineer Kate Dolezal, MA, CRC, LPC Technical Coordinator Engineering Department 2017-43

The Joint Commission Disclaimer These slides are current as of 3/31/2016. The Joint Commission reserves the right to change the content of the information, as appropriate These slides are only meant to be cue points, which were expounded upon verbally by the original presenter and are not meant to be comprehensive statements of standards interpretation or represent all the content of the presentation. Thus, care should be exercised in interpreting Joint Commission requirements based solely on the content of these slides These slides are copyrighted and may not be further used, shared or distributed without permission of the original presenter or The Joint Commission Engineering Department 2017-44