YP7899C SERIES Burner Management Panel

Similar documents
YP7999A1000 ControLinks Fuel Air Ratio Control Panel

7800 SERIES RM7888A Relay Module

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7888A Relay Module

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

7800 SERIES EC7823/RM7823 Relay Module

RM7838A 7800 SERIES Relay Modules

7800 SERIES 22-Terminal Universal Subbase

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

7800 SERIES RM7840E,G,L,M Relay Module

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

7800 SERIES EC7885A/RM7885A Relay Module

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

RM7897A,C 7800 SERIES Relay Modules

RM7890; RM Vac 7800 SERIES Relay Modules

R7120M 7800 SERIES Relay Modules

Q7800H Integrated Burner Control Subpanel

RM7895A,B,C,D/EC7895A,C; RM7896A,C,D 7800 SERIES

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

RM7890D; RM7895E,F 7800 SERIES Relay Modules

7800 SERIES S7830 Expanded Annunciator

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

RM7890A1056, RM7890B SERIES

7800 SERIES EC7810A, EC7820A Relay Module

APPLICATION SPECIFICATIONS INSTALLATION INSTRUCTIONS. The following assumptions apply when using the RM7840G,L, RM7800L, EC7840L:

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Cleaver-Brooks CB780/CB784 Operation and Maintenance Manual

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Sola Hydronic Control. An Eco-Friendly Solution.

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Commercial/Industrial Combustion Control Level Three Announcement

CR Series Command Relays

7800 SERIES RM7824A Relay Module

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

7800 SERIES Relay Modules

Honeywell Thermal Solutions COMBUSTION CATALOG

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

R7140G,L,M Burner Control Modules

COMBUSTION CATALOG. Honeywell Thermal Solutions Honeywell Thermal Solutions Combustion Catalog

Honeywell Primary Control Cross Reference

Instructions For A and Flame Simulators

7800 Series RM7888A Relay Module

7800 SERIES S7800A2142 Keyboard Display Module

SAFETY CONTROL REQUIREMENTS FOR OVENS AND FURNACES

Flame Safeguard Fault Code Diagnostics

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

BGH Series Hot Surface Ignition Control

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

LFL Series Burner Flame Safeguard Control

Indirect gas-fired air heater

RA890G Protectorelay Primary Control

MBCE-110/230UV Flame Sensor Module

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

Power Supply Display Module PSDM. Installation and Operation Manual

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

T7079A,B Solid State Remote Temperature Controllers

C6097A,B Pressure Switches

Power Flame Incorporated

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Power Flame Incorporated

ACL TC 200 TEMPERATURE CONTROLLER

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

7800 SERIES S7800A1167 Keyboard Display Module

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Model 60200FR Gas Primary Control Data Sheet

ECLIPSE INFORMATION GUIDE

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

MBCE-110/230FR Flame Sensor Module

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

INSTALLATION INSTRUCTIONS

Honeywell SLATE ICM Platform

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

COMBUSTION SAFETY AND EFFICIENCY

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Model Universal Oil Primary Control

C7232A,B Sensor and Controller

24 VAC Direct Spark Gas Ignition

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

C7005A,B Gas Pilot and Flame Rod Assemblies

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

24 VAC Intermittent Pilot Gas Ignition Control

Eclipse Trilogy Flame Safeguards

BC-R10 Series. Burner Controllers

RA889A Switching Relay

Transcription:

YP7C1000 700 SERIES Burner Management Panel INSTALLATION INSTRUCTIONS 65-00, ST700A,C 700 SERIES Plug-In Purge Timer 65-0, S710M Modbus Module 60-06, C707, C7035, C70, C77 Minipeeper UV Flame Detector 65-067, C761 Dynamic Self-checking Solid State UV Flame Detector 60-0, C715 Infrared Flame Detector 65-077, C76 Visible Light Flame Detector 60-0, C7007, C700, C700 flame Rod Detector 5-6, C7076 Adjustable Sensitivity UV Flame Detector 60-3, C701 Ultraviolet Flame Detectors 51-5-5-17, UDC500 Product Manual 51-5-5-11, UDC Limit Control Model Product Manual 51-5-5-66, UDC Modbus RTU Serial Communications User Manual FEATURES APPLICATION The 700 SERIES Burner Management Panel is a packaged, pre-wired panel that includes the RM700L107 burner control, a modbus interface, two DC500 controls for on/off and limit control and the S7D color touchscreen interface The S7D allows monitoring and control of the RM and DC controls via the modbus interface, all with user-friendly menus On board switches, buttons and alarm lights are included for customer convenience The burner control purge card, amplifier and flame detector are purchased separately This document provides installation instructions and operation information Other applicable publications are: 65-031, S7D10 System Display 66-115, RM700L107 Relay Module with Valve Proving 65-0, S700A11 Keyboard Display Module 700 SERIES 65-00, 700 Series Relay Module Checkout and Test 65-00, Q700A 700 SERIES -Terminals Universal Wiring Subbase 66-03, R7xx Amplifiers for 700 SERIES and R710 Relay Modules Pre-wired and ready to install Includes the RM700L107 burner control with wiring subbase, S710M modbus module, two DC500 controls and the S7D touchscreen display Monitor and control through the touchscreen interface Burner on/off selector switch Alarm lights Reset buttons Unit shutdown / Emergency stop button S7D touchscreen display is modbus ready VPS (Valve Proving System) capability via flame safeguard control SPECIFICATIONS Electrical Ratings 10 Vac, 50/60 Hz, 10 Amps For individual ratings, see component literature for details Environmental Ratings Enclosure: NEMA 1 For individual ratings, see component literature for details 66-061-01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL Humidity Install the panel where the relative humidity never reaches the saturation point The relay module inside the panel is designed to operate in a maximum 5 percent relative humidity continuous, non-condensing, moisture environment Vibration Do not install the panel where it could be subjected to vibration in excess of 05G continuous maximum vibration General Overall panel size: in high x in wide x in deep (excluding door and door mounted components) Panel weight: approx 75 pounds Mounting holes are 0 in typical diameter, 1 in on center Approvals Components are individually approved by the nationally recognized agencies Please see component literature for details The panel has UL 50A approval Panel is assembled and wired to the UL Standards INSTALLATION When Installing This Product 1 Read these instructions and the appropriate product literature carefully Failure to follow them could damage the product or cause a hazardous condition Refer to the installation manuals and wiring diagrams provided with this panel for the embedded products 3 Read these instructions and the appropriate product literature carefully Failure to follow them could damage the product or cause a hazardous condition Refer to the installation manuals and wiring diagrams provided with this panel for the embedded products 5 Check the ratings given in the instructions and on the product to make sure that the product is suitable for your application 6 Installer must be a trained, experienced combustion service technician 7 Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage More than one disconnect may be involved All wiring must comply with the National Electric Code (NEC) and any applicable local electrical codes, ordinances and regulations After installation is complete, check out product operation as provided in the appropriate product installation instructions WARNING Fire or Explosion Hazard Can cause severe injury, death or property damage To prevent possible hazardous burner operation, verify safety requirements each time a controller is installed on a burner WIRING WARNING Electrical Shock Hazard Can cause serious injury, death or equipment damage Disconnect the power supply before beginning wiring to prevent electrical shock, equipment and control damage More than one disconnect may be involved Ground Connection Earth ground is required for proper operation of the panel and components The earth ground must be capable of conducting enough current to blow the fuse or breaker in the event of an internal short Ensure the panel is bonded to a substantial earth ground Make sure that mechanically tightened joints along the ground path are free of nonconductive coatings and protected against corrosion on mating surfaces Electrical Connections 1 Refer to the appropriate product data sheet for details Wire size and length will vary, depending on the component Refer to the component literature for specific wire lengths, sizes and type recommendations 3 Wire according to specifications, following all local ordinances and requirements Field knockouts are required for the wiring When drilling holes, take care to protect the electronics from metal pieces and debris IMPORTANT Run line voltage and low voltage wiring in separate conduit to avoid signal interference Carefully check field wiring and terminal designations in this document and the associated wiring diagram They are different from those of the individual components Panel Inspection After mounting and wiring, but before powering the panel, inspect all internal panel wire connections Wires may loosen during transit Verify that all internal wire connections are secure from the wiring subbases to the components mounted on the door and the S7D touchscreen interface Final Wiring Check and Static Checkout All wiring shall be in accordance with the National Electric Codes (NEC) and local electrical codes 1 Check the power supply circuit The voltage and frequency must match the specification listed Check wiring terminations and routing to ensure proper connections 3 Follow any system checkout recommendations for individual components as found in the component literature Restore power to the panel 66-061 01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL CAUTION Test each limit and interlock to ensure system operates correctly as defined in the 700 Series Checkout and Test document (Form #65-0) WARNING Explosion and Electrical Shock Hazard Can cause serious injury, death or equipment damage 1 Close all manual fuel shutoff valves before starting these tests Use extreme care while testing the system Line voltage is present on most terminal connections when power is on 3 Replace all limits and interlocks that are not operating properly Do not bypass limit and interlocks TROUBLESHOOTING System Diagnostics The S7D touchscreen interface indicates the current fault and keeps a fault history log The RM700L control also has LED fault blink codes The DC controls have various tests and status messages Refer to the appropriate product instruction sheet for further troubleshooting information and diagnostic codes 3 66-061 01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL FIELD WIRING Table 1 Field Wiring and Terminal Designation 1 Terminal # To Connecting Device Description 1 L1 Panel power 10Vac Power Supply, 10A Max Provide disconnect means and overload protection as required L Panel neutral Panel ground -5 3 Airflow Switch Combustion airflow (pressure) switch 5-6 3 LP Switch Fuel low pressure/temperature switch 6-7 3 HP Switch Fuel high pressure/temperature switch 7-3 Interlocks Fuel customer interlocks and limits, including LWCO, high-limit, etc 10-3 Burner Control On/off burner operating control 11 Blower Motor Combustion blower motor line voltage output from burner control 15 Shutter Drive Shutter drive output connection from burner control 17 F Flame detector F lead connection from burner control Panel ground Flame detector G lead connection from burner control XF- 5 Ignition Spark ignition transformer 1- Low Fire Switch Low fire switch input to burner control 0- High Fire Switch High fire switch input to burner control - Pilot Valve(s) Pilot fuel valve(s) connection to burner control output 10 second interrupted pilot 1-6 Main Valve(s) Main fuel valve(s) connection to burner control output - 3 POC Switch 1 Main fuel valve 1 proof of closure switch (pre-ignition interlock switch) -3 3 POC Switch Main fuel valve proof of closure switch (pre-ignition interlock switch) 5-6 Limit Relay Out High limit alarm #1 relay output, NC (DC500 control) 6-7 Limit Relay Out High limit alarm #1 relay output, NO (DC500 control) - Low Fire Out Customer convenience wire point - Low fire output to firing rate motor indication 30-31 High Fire Out Customer convenience wire point - High fire output to firing rate motor indication 3-33 Modulate Out Customer convenience wire point - Modulate output to firing rate motor indication 3-35 Alarm Out Customer convenience wire point - Burner control alarm output indication 0 7 Temp/Press Limit + High temperature/pressure limit + input (DC500 control) 03 7 Temp/Press Limit - High temperature/pressure limit - input (DC500 control) 06 Mod Motor + Low fire / + connection to -0mA modulating motor (damper/valve) 07 Mod Motor - Common / - connection to -0mA modulating motor (damper/valve) 10 Mod Motor F High fire / F connection to -0mA modulating motor (damper/valve) 0 7 Temp/Press Control + Temperature/pressure fire rate controller + input (DC500 control) 0 7 Temp/Press Control - Temperature/pressure fire rate controller - input (DC500 control) 1 COM A S7D COM modbus A / Data + terminal 15 COM B S7D COM modbus B / Data - terminal 13 COM S7D COM Modbus C / Ground terminal 1 Carefully check field wiring and terminal designations in this document and the associated wiring diagram They are different from those of the individual components The circuit protection incorporated into this control panel is designed to serve as supplemental protection only It is the responsibility of the end user to provide appropriate protection on the service to this control panel Refer to the National Electric Code and UL standard 1077 for more information on this subject 66-061 01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL 3 Jumper all unused limits, interlocks and valve proof of closure switches Refer to the appropriate flame detector product sheet for wiring size and length information Run flame detector F and G leads in their own conduit, independent of other power carrying leadwires Flame detector power and shutter wires (if applicable) must be run in their own conduit as well, avoiding other electrical noise carrying wiring The scanner wires should remain separated a minimum of inches from other line voltage wires in the control panel to the flame safeguard device 5 Refer to the appropriate ignition transformer product sheet for wiring size and length information Separate the high voltage ignition cable from other wires to avoid interference Ignition cable to the spark electrode must be run in separate conduit (if applicable) 6 If VPS (Valve Proving System) usage is required with the RM700 burner control, contact factory for advice regarding wiring 7 For high temperature limit, wire Type K thermocouple + input (yellow) to + terminal and - input (red) to - terminal For pressure limit, supply appropriate transmitter and program DC500 controller for pressure operation Thermocouple or transmitter wires must be run in separate conduit with other low voltage wires to avoid signal interference DC500 controls from the factory are set-up for temperature, but can be modified in the field for pressure operation Firing rate control output is -0mA A -0mA firing rate/modulating actuator should be used with this panel Run actuator low voltage field wire in separate conduit with other low voltage wires to avoid signal interference Motor may be powered from panel T (L1) and T (L) or separately COM on the S7D is wired in a daisy-chain fashion to the S710M Modbus module on the RM700L burner control and the UDC500 controls in the panel for display on the S7D Customer may wire other Modbus-enabled UDC500/300/3500 controls in a daisy-chain fashion to the customer terminals provided for display on the S7D Refer to the S7D and UDC control product manuals for further information on wiring and S7D display set-up 10 Installation, operation and maintenance shall conform with National Fire Protection Association standards, national and local codes and authorities having jurisdiction 11 For detailed device wiring information, refer to the RM700, Q7, S7D10 and DC500 product sheets 1 Spare/unused terminals are provided for customer field use 5 66-061 01

5005-001 Rev A YP7C1000 700 SERIES BURNER MANAGEMENT PANEL (610) HIGH LIMIT Honeywell HTL01 PB101 EMERGENCY STOP HMI306A R PUSH TO STOP TWIST TO START (610) CONTROLLER CTLR0 SS10 LT105 LT1 BURNER OFF ON INTERLOCKS PROVEN W PILOT S ENERGIZED B LT13 BURNER ON G LT11 FSG ALARM R PB113 FLAME SAFEGUARD RESET Y! WARNING Electrical Shock Hazard Can cause serious injury, death or equipment damage Disconnect the power supply before beginning installation to prevent electrical shock, equipment and control damage More than one power supply disconnect may be required! AVERTISSEMENT Risque de choc électrique Peut provoquer des blessures graves, entraîner la mort ou causer des dommages matériels Couper l'alimentation électrique avant de commencer l'installation pour éviter les chocs électriques, les dommages au matériel et au régulateur Il faudra peut-être utiliser plus d'un dispositif de coupure d'alimentation M35 NOTES: 1 THE CIRCUIT PROTECTION INCORPORATED INTO THIS CONTROL PANEL IS DESIGNED TO SERVE AS SUPPLEMENTAL PROTECTION ONLY IT IS THE RESPONSIBILITY OF THE END USER TO PROVIDE APPROPRIATE PROTECTION ON THE SERVICE TO THIS CONTROL PANEL REFER TO THE NATIONAL ELECTRICAL CODE AND UL STANDARD 1077 FOR MORE INFORMATION ON THIS SUBJECT JUMPER ALL UNUSED LIMITS AND INTERLOCKS 3 FIELD WIRING SHOWN FOR BLOCK AND BLEED ARRANGEMENT POSITION SWITCH IS REQUIRED, TYPE AND MODEL MUST BE SPECIFIED THIS ITEM IS NOT INCLUDED WITH THE CONTROL PANEL 5 FIELD WIRE TO THE DETECTOR SHOULD BE #1 AWG TYPE TW 600V INSULATED WIRE OR EQUAL WIRE MUST NOT BE IN THE SAME CONDUIT WITH POWER WIRING WIRE CODE FUNCTION COLOR AWG 0 VAC (HOT) BLACK 0 VAC (NEUTRAL) WHITE 10 VAC (HOT) RED 10 VAC (NEUTRAL) WHITE EXTERNAL POWER SOURCE YELLOW DRY CONTACTS YELLOW VDC BLUE VAC -0 ma SIGNAL BROWN BLUE TYPE J THERMOCOUPLE WHITE/RED 0 (POLYVINYL) TYPE K THERMOCOUPLE YELLOW/RED 0 (POLYVINYL) F30 RESETS/DISPLAY/CONTROL BUS BELDEN (AWG) TWISTED PAIR GROUND GREEN 1 (MTW) 6 IGNITION CABLE TO THE SPARK ELECTRODE MUST BE RUN IN SEPARATE CONDUIT (IF APPLICABLE) 7 FIELD WIRE TO THE FIRING RATE ACTUATOR MUST BE RUN IN SEPARATE CONDUIT THERMOCOUPLE WIRES MUST BE RUN IN SEPARATE CONDUIT INSTALLATION, OPERATION AND MAINTENANCE SHALL CONFORM WITH NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS, NATIONAL AND LOCAL CODES, AND AUTHORITIES HAVING JURISDICTION INDICATES TERMINALS AND WIRING IN MAXON CONTROL PANEL (MAIN TERMINAL BLOCK) INDICATES EXTERNAL WIRING INDICATES TERMINALS IN MAXON S INDICATES COMPONENT TERMINALS M36 Fig 1 Panel front dimensions in in (mm) and notes 66-061 01 6

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL 1 (533) CUT FOR FLOOR LAYOUT 1 1 (533) CUT FOR FLOOR LAYOUT 3 5 5 6 6 7 7 10 11 1 13 1 15 16 17 1 0 1 1 1 1 3 5 6 7 30 31 3 33 3 35 XF 00 01 0 05 06 07 10 11 11 13 13 13 1 15 15 1 FU101 10A POWER PILOT FLAME MAIN ALARM RESET FU01 5A FU0 5A Honeywell FU30 5A FSG107 KBD11 MODE BURNER CONTROL CR10 CR110 CR111 CR11 XF301 CUT FOR FLOOR LAYOUT + - + - 0 03 0 0 CUT FOR FLOOR LAYOUT M37 Fig Equipment mounting panel dimensions in in (mm) 7 66-061 01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL 100 10/1/60 USE 16 AWG MTW WIRE 101 1 FU101 10A NOTE 1 3 EMERGENCY STOP PB101 1 10 103 COMBUSTION LOW GAS HIGH GAS AIR PRESSURE PRESSURE PRESSURE CUSTOMER PS103 5 PS103A 6 PS103B 7 INTERLOCKS NOTE HIGH LIMIT HTL01 0 1 to 03 to 03 10 105 LT105 W INTERLOCKS PROVEN 106 HONEYWELL RM700L-107 FSG107 107 10 BURNER SS10 OFF ON OX 10 3 7 L LOCKOUT/ RUNNING INTERLOCKS 6 BRN CTRL LIMITS LINE VOLTAGE COMMON 5 BURNER MOTOR 11 10 110 111 11 113 11 115 116 11 FROM 311 10 FLAME SAFEGUARD FROM 310 RESET 07 PB113 01 FROM 31 BLK BLK 3 00 CLR CLR 1 3 5 6 7 LOW FIRE SWITCH LS116 HIGH FIRE SWITCH LS117 HONEYWELL S710M-1003- MODBUS KBD11 NOTE RED CLR BLK 1 0 16 PROVING SWITCH 17 DEMAND PROVING 13 COMMON L1 LINE VOLTAGE SUPPLY 1 LOW FIRE SWITCH INPUT 1 HIGH FIRE 1 LOW FIRE 15 MODULATE SHUTTER F FLAME SENSOR FLAME G SENSOR GROUND 3 ALARM 10 IGNITION PILOT / IGNITION 1 13 1 15 17 BLU WHT XF TO 10 1 NOTE 5 ULTRAVIOLET DETECTOR ST11 XF115 SPARK IGNITION TRANSFORMER H1 H X1 X 16 CR10 13 1 HIGH FIRE NO 1,3 NC CR110 13 1 LOW FIRE NO 1 NC CR111 13 1 MODULATE NO 16 NC 1 LT11 FSG R X1 X ALARM CR11 13 1 NOTE 6 SPARK PLUG SP115 FSG ALARM NO NC 1 117 MAIN FUEL BLOCKING FUEL SOL17 SOL130 3 HIGH FIRE SWITCH INPUT 0 MAIN FUEL 1 TO 1 11 (PROOF OF CLOSURE) (PROOF OF CLOSURE) PREIGNITION INTERLOCK 15 SEC INTERR PILOT VLV, MV TO 1 TO 1 M3 Fig 3 Wiring diagram (part 1) 66-061 01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL 1 FROM 11 FROM 11 LT1 B PILOT S X1 X ENERGIZED 10 FROM 115 SOL10 VENT PILOT 11 NOTE 3 SOL11 MAIN PILOT 1 SOL1 BLOCKING PILOT 13 1 1 FROM 116 1 SOL1 MAIN FUEL VENT 15 16 17 1 SOL17 MAIN FUEL 1 NOTE 3 11 130 1 SOL130 BLOCKING FUEL 131 11 13 1 LT13 G X1 X BURNER ON 133 13 135 TO 00 TO 00 M3 Fig Wiring diagram (part ) 66-061 01

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL FROM 135 FROM 135 00 01 FU01 5A HIGH LIMIT HONEYWELL DC500-EE-L0R-00-00000-00-0 HTL01 L1/H L/N 0 03 TC03 TYPE K THERMOCOUPLE NOTE 03 0 5 R INPUT 1 6 + INPUT 1 7 - #1 OUTPUT 0 #1 OUTPUT 1 FROM 103 FROM 103 0 05 06 07 RED CLR BLK 07 10 11 SHLD 16 SHLD COMM 17 D+ (B) COMM 1 D- (A) 7 ALARM #1 ALARM #1 ALARM # 5 ALARM # 6 5 6 7 5 6 7 0 FROM 31 FROM 310 FROM 311 07 10 11 0 10 DRY CONTACTS FOR CUSTOMER USE 11 1 LOW FIRE CR110 YEL YEL 5 13 1 HIGH FIRE 30 CR10 31 YEL YEL 1 15 16 MODULATE 3 CR111 33 YEL YEL 1 17 1 TO FSG ALARM 3 CR11 35 YEL YEL 5 Fig 5 Wiring diagram (part 3) TO M300 66-061 01 10

YP7C1000 700 SERIES BURNER MANAGEMENT PANEL FROM 1 FROM 1 0 1 CONTROLLER HONEYWELL DC500-CB-A0R-00-00000-00 CTLR0 FU0 36 5A L1/H L/N MODULATE CR111 0 0 NOTE 7 1 10 (+) BLK OUTPUT 1 06 11 (-) 1 CLR 1 (+) 13 (-) 3 TC TYPE K THERMOCOUPLE NOTE 1 17 5 R INPUT 1 6 + INPUT 1 7-7 ALARM #1 ALARM #1 5 RED 16 SHLD COMM CLR 17 D+ (B) COMM 6 07 10 11 BLK SHLD 1 D- (A) 7 FROM 31 07 FROM 310 10 FROM 311 11 HONEYWELL MODULTROL MOTOR CM L N 30 31 NOTE 7 CLR BLK 13 0 3 3 (-) (+) 3 HIGH FIRE CR10 5 7 F 33 3 35 TO 300 TO 300 M301 Fig 6 Wiring diagram (part ) 11 66-061 01

RED WHT BLK YP7C1000 700 SERIES BURNER MANAGEMENT PANEL FROM 35 FROM 35 300 301 30 INPUT 10 VAC 0 FU30 5A 05 SYSTEM DISPLAY POWER SUPPLY XF301 (L) (+) (G) (N) (-) OUTPUT VAC 303 0 30 305 306 COM1 A COM1 B HMI306A HONEYWELL S7D10 SYSTEM DISPLAY COM1 C COM A COM B COM1 C COM +VAC 1 3 5 6 7 07 307 30 30 10 11 07 1 16 07 310 311 31 10 TO 113,0,7 11 TO 11,0,7 07 TO 113,0,7 RED WHT BLK 313 31 315 316 317 31 M30 Fig 7 Wiring diagram (part 5) Automation and Control Solutions Honeywell International Inc 5 Douglas Drive North Golden Valley, MN 55 customerhoneywellcom US Registered Trademark 013 Honeywell International Inc 66-061 01 MS 07-13 Printed in United States