Operating Instructions

Similar documents
Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Original operating instructions Safety switch with guard locking AC901S AC902S

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Customer Operation & Installation Manual Electric Panel Heaters

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

AUTOMATIC VACUUM UNIT

This instruction manual explains the use of three models listed on the left.

KK70 Silent. Installation and Operating Instructions L V001

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

MODEL 7000 SUCTION UNIT

Rotary Tube Furnaces

Waste water ejection unit

Manual Power relay SR853

Service package PDAD- -SP (en) Assembly instructions d [ ]

Instructions for the fan motor control system with integrated wiring terminals SILVER C

EN Instruction manual

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

UFM-T100H US ES CA Power Alarm Test TM

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Swaging Machine Type H50-46ECO

Instructions For Use ENG. LED Magnifier Lamp

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

PVL1300 INSTRUCTIONS FOR USE

Translation of the assembly instructions with operating instructions and technical appendix

Operating Manual MS220KA and MSR220KA

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

POLYMIX PX-IG 2000 Operating Instructions

FSW300 Series Flow Switch

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Alarm System SECURE AS 302

Stainless Steel Chimney Extractor

Service: to SLK Laboratory Hot Plates glass made of ideas

Installer manual AG-WL10

A measured step forward

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

UV - Monitor UVT 16. Use. Description

Instruction Manual. Electronic gas and smoke detector GRM

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Product waste disposal - Protection of the environment:

Instructions for the fan motor control system, SILVER C

Operation Manual. Trash Water Pump ARTICLE Image similar

Operating Manual. VIENNA Hot Display

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Original instructions Sense7-series Non-contact coded safety switch

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

Stainless Steel Chimney Extractor

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN

TTV 4500 / TTV 4500 HP / TTV 7000

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

HSGM Heißschneide-Geräte

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

Installation and operating instructions. DK energy storage and DK energy buffer

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

SCHMIDT LED Measured Value Display MD Instructions for Use

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Operating Manual MS220DA

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

R1000 / R1040 / R1080

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

BAYSIDE NAUTILUS CEILING FAN

EHA Hoffmann International GmbH

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

SP420 & SP14 SP520 & SP15 SP920 & SP19. 08/19222/9 (UK) - Issue 9

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Bench-Top Vacuum Oven with 28 segments programmable controller

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

60cm Integrated Turbo Extractor

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Approved by: Document no.: EGT

Advantages / Characteristics

E-17 Flammable Gas Detection and Alarm System

ELECTRIC FAN HEATERS

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Transcription:

Operating Instructions ir Monitoring System Puracon Stationary PRO Version: 11/14-E www.uebler.net

TBLE OF CONTENTS General Information and Technical Data General Information, Description of marks and warning signs... 3 Scope of Delivery... 4 Technical Data... 5 Unit ssembly - Display unit... 6 Unit ssembly - Sensor... 7 Safety Precautions Intended Use, Operators... 9 General Safety Precautions... 10 Installation Montage ufbau nzeigegerät... 12 Installation Sensor... 14 Connection plan display unit... 15 Electrical connection... 16 Operation Important operation instructions, Legal regulation and filling authorization... 19 Start unit / Dry unit... 20 Menu settings... 21 Error messages... 23 Maintenance and Service Maintenance Work... 25 Maintenance Lists / Maintenance Intervals... 25 Sensor maintenance / Check / Return to manufacturer... 26 Check sinter filter / Replacement of the seal... 27 Disposal / Electric and electronic components... 28 Puracon Filter Monitoring Page - 2 Version: 171114-001

GENERL INFORMTION General Information We strongly recommend reading this manual thoroughly prior to operation and follow all the safety precautions precisely. Damage resulting from any deviation from these instructions is excluded from warranty and liability for this product. Carry out other commissioning steps only if you have fully understood the following contents. Before commissioning and using the unit, carry out all the essential preliminary work and measures concerning legal regulations and safety. These are described on the following pages of this operation manual. Description of marks and warning signs The following warning signs are used in this document to identify the corresponding warning notes which require particular attention by the user. The warning signs are defined as follows:! Caution Indicates an imminently hazardous situation which, if not avoided, could result in serious injury, physical injury or death.! Warning Indicates a potentially hazardous situation which, if not avoided, could result in physical injury or damage to the product or environment. i Note Indicates additional information on how to use the unit. Puracon Filter Monitoring Page - 3 Version: 271012-001 E

DESCRIPTION Scope of Delivery This device is used for controlling of the air/gas humidity value during the filling process of air/gas tanks by compressors with a final pressure up to 420 bar. Specifications luminum sensor housing with inlet and outlet connection G¼ Display unit (120 x 120 x 60 mm) for wall mounting with sensor cable (length: 2 m) Power supply cable (length 1.7 m) with CE plug 24VDC and 100-/240 V C ~ 50/60 Hz Digital LCD display with humidity display in mg/m³ and error warnings 2 monitoring LEDs, adjustable limits Sensor cables with 5, 10, 15 or 30 m available for surcharge pproved up to 350 bar Stainless steel sensor optional, approved up to 420 bar utomatic condensation (optional) Heater for external installation of the display unit (optional). vailable versions Sensor 350bar Sensor 420bar Standard plug-in power supply unit DIN-rail power supply unit incl. relay for emergency shutdown or automatik condensation drain Explosion-proof sensor with TEX certification Puracon Filter Monitoring Page - 4 Version: 171114-001

DESCRIPTION Technical Data Technical Data Display Unit Dimensions L x W x H [mm]: 82 x 107 x 40 Installation dimensions L x W x H [mm]: 82 x 120 x 40 Weight [g]: Power supply: Protection Class: Medium: Relay switching capacity: 560 g 24VDC 150m / optionally with heater 300m IP64 ir / NITROX up to 40% O² / Inert gases max. 30V / 300m mbient Temperature [ C]: +5 to +40 / optionally with heater -15 to +40 Technical Data Gas: Sensor Compressed ir Dimensions L x W x H [mm]: 90 x 60 x 50 Installation dimensions L x W x H [mm]: 90 x 60 x 150 Weight / basic material: Sensor temperature range [ C]: ir / Gas temperature range [ C]: Cover screw: Edelstahl 1.4301 1200g / max. Druck 420 bar luminium lmgsi1 450g / max Druck 350 bar +5 to+45 C +5 to +45 C M8 x 30 Steel 10.9 ISO7380 or DIN912 for 420bar M8 x 30 Stainless Steel 2 ISO7380 or DIN912 to 350bar Filter: 50µm Protection Class: Type: IP64 RSE_2012_4-20m_Sensor Puracon Filter Monitoring Page - 5 Version: 171114-001

DESCRIPTION Unit ssembly - Display unit The display unit converts the sensor signal to a digital display value. Power supply directly with 24 VDC or by the included 100-240V switching power supply. The LCD display shows the present humidity level in mg/m³ and/or self-test and alarm messages. 1 3 2 4 5 7 8 6 No. Designation 1 LCD display 2 UP - Button 3 ENTER - Button 4 DOWN - Button 5 Red - replace filter cartridge 6 Green - filter cartridge OK 7 Connection cable 8 Sensor cable Puracon Filter Monitoring Page - 6 Version: 171114-001

DESCRIPTION Unit ssembly - Sensor The sensor housing contains the highly sensitive sensor that monitors the moisture content. The housing should be mounted in the high pressure pipeline. 1 2 3 4 No. Designation 1 Connection sensor cable 2 Sensor cable 3 Pipe connection 4 Pipe connection Puracon Filter Monitoring Page - 7 Version: 131114-001

SFETY PRECUTIONS

SFETY PRECUTIONS Intended Use Only use the unit in perfect condition for its intended purpose, safety and intended use and observe the operating instructions! In particular disorders that may affect safety have to be eliminated immediately! Use the unit exclusively for the determined medium (see "Technical Data"). ny other use that is not specified is not authorized. The manufacturer/supplier shall not be liable for any damages resulting from such use. Such risk lies entirely with the user. uthorization for use is also under the condition that the instruction manual is complied with and inspection and maintenance requirements are enforced. No change and modification to the unit can be made without the written agreement of the manufacturer. The manufacturer is not liable for damage to persons or property resulting from unauthorised modifications. Operators Target groups in these instructions; Operators Operators are persons who are authorized and briefed for the use of the compressor. Qualified personnel Qualified personnel are persons who are entitled to repair, service, modify and maintain the system.! Warning Only trained personnel are permitted to work on the unit!! Warning Work on the electrical equipment on / with the machine / unit may only be carried out by qualified electricians. Puracon Filter Monitoring Page - 9 Version: 261012-001 E

SFETY PRECUTIONS Strictly follow the instruction for use ny use of the device requires full understanding and strict observation of this instruction. The device is only to be used for purposes specified here. lso pay attention to the specific instructions for the use of compressors, filling stations and to the corresponding statutory requirements and standards. Maintenance The device must be inspected regularly (examination of actual condition), calibration and adjustment (compare with true values) and maintenance by competent personnel to maintain the specified condition. Liability for proper function or damage The liability for the proper function of this device is irrevocably transferred to the owner or operator to the extent that the device has been serviced or repaired by personnel not employed or authorized by Lenhardt & Wagner or when the device was used in a manner not conforming to its intended use. Lenhardt & Wagner and its distribution partners cannot be held responsible for damage caused by non-compliance with the recommendations given above. The warranty and liability provision of the terms of sale and delivery of Lenhardt & Wagner and its distribution partners are likewise not modified by the recommendation given above. Safety regulations Inspections according to legal and local obligatory regulations regarding accident prevention are carried out by the manufacturer or by authorised expert personnel. No guarantees whatsoever are valid for damage caused or favoured by the non-consideration of these directions for use. Puracon Filter Monitoring Page - 10 Version: 270513-001 E

INSTLLTION

INSTLLTION Display unit installation - surface-mounted The display unit can be mounted on a mounting plate with 4 screws M3 without opening the housing (Fig. 1, point 1). The housing is provided with 4 pre-punched holes to be mounted from the inside. These holes must be drilled manually (Fig. 1, point 2). In this case, the housing must be opened. First remove the 4 screws M3 at the front of the housing (Fig. 2). i Note If the rubber seal is attached between upper and bottom section by vacuum (the cover cannot be removed), wait 1-2 minutes (Fig. 2). Remove cover and plugs (Fig. 3). Drill 4 mounting holes, see pre-punched holes on the rear side (Fig. 1, point 2). 1 2 3 Fig. 1 - Mounting holes Fig. 2 - Cover screws Fig. 3 - Remove plugs The direction of the cable outlets can be chosen freely by rotating the cover! Puracon Filter Monitoring Page - 12 Version: 171114-001

INSTLLTION Display unit installation - front panel installation The cover of the display unit can also be installed into a front panel with an opening of Ø 63mm (standard opening of a 63mm pressure gauge). Drill 4 holes in the front panel, install 4 spacers M3x6mm, place sealing and mount the display on the spacers by 4 screws M3x6mm. Wiring on the rear side. Sealing 4 Spacers Puracon Filter Monitoring Page - 13 Version: 171114-001

INSTLLTION Mechanical installation! Danger Before any work will be carried out, isolate the power supply to prevent injury and reduce the pressure in the pipes to atmospheric pressure. The installation of a non-return value in the outlet of the sensor housing towards the filling panel may only be carried out by a qualified technician. For installation observe the following: We recommend using G1/4 Ermeto connections. Before mounting the housing, tighten the screws again (Fig. 2). ttention: Screw depth max. 4 mm! Mount the sensor tightly at a place with low vibration. Mount the sensor at least by two M8 mounting screws. n installation only by gas lines is not allowed! Fig. 1 - G1/4 Ermeto connection Fig. 2 - Retighten cover screws Fig. 3 - Rear sided opening M8 Puracon Filter Monitoring Page - 14 Version: 270513-001 E

INSTLLTION Connection plan display unit i Hinweis The alarm output 2 is not isolated! Maximum power: Power supply: 40m / power supply: 100m 8 9 7 10 5 6 1 2 3 4 No. Designation 1 24VDC positive terminal (pink) 2 0 GND (blue) 3 Switching output optional automatic condensation (yellow) 4 larm switching output for motor emergency stop (white) 5 Sensor signal input (blue) 6 Sensor 24VDC supply (brown) 7 Kanal 1: 4-20m input (100R) signal blue) 24V (brown) 8 Kanal 2: not assigned 9 Kanal 3: not assigned 10 Kanal 4: not assigned Puracon Filter Monitoring Page - 15 Version: 171114-001

INSTLLTION Electrical connection Connect sensor cable (Fig. 1) ttention: The gas lines must be connected to earth. Connect power supply: 240 VC - connect the plug to socket. Compressor shutdown (optional) If the humidity value is too high (red LED) the compressor will be switched off. Semiconductor output for max. 24VDC-300m. Fig. 1 - Connect sensor cable utomatic condensation (optional) The condensate valve is controlled automatically. Semiconductor output for max. 24VDC-300m. For any questions about options, please contact us. i Note The unit must be earthed to avoid electromagnetic interference! Use the earthed gas line (a shielded sensor cable must be used) or mount the rear side of the housing with the openings M3 on an earthed mounting plate (e.g. filling panel). Puracon Filter Monitoring Page - 16 Version: 171114-001

INSTLLTION Electrical connection when using external relays! Caution The unit is designed for a maximum voltage of 28VDC-300m. Caution! Never connect the unit to 230VC. Remove plug-in power supply and cable. Connect a 3-pole cable (min. 3x0,25mm², max. length 10m). Connect power supply and the required relay (Optional). 7 6 3 4 1 8 10 3 9 3 2 No. Designation 1 DSP-10-24 DIN switching power supply 10Watt, 24VDC, 300m 5 2 100-240VC input 3 +24VDC 300m output (pink) 4 0V ground output (blue) 5 4-pole display unit cable 6 Condensate relay (switching capacity 10 300VC) 7 larm or motor relay (switching capacity 10 300VC) + Signal lamp max..24v / 100m 8 Signal LED with protective diode (CUTION! lways operate the relay with protective diode) 9 Switching line of the display unit for automatic condensation (yellow) 10 Switching line of the display unit for the alarm or motor relay (white) Puracon Filter Monitoring Page - 17 Version: 12.03.2015

OPERTION

OPERTION Important operation instructions Each contamination and humidity values higher than 60 mg/m³ can influence the measurement or/ and damage the sensor. Ensure a clean pipe line system. Before mounting, the pipes must be cleaned from contamination to avoid damage of the sensor. Every contamination can reduce the measured values or damage the sensor. Each excessive pressure and temperature changes can produce condensate. Humidity values higher than 60 mg/m³ can reduce the sensor lifetime. High pressure and temperature changes provoke high humidity fluctuation. Too high system humidity tends to condensate. Consistent measurement or sensor protection from condensation as follows: - avoid gas flow returning into the pipe system - do not exceed the maximum humidity value of 25mg/m³ (orange LED) according to EN12021 (2012) - prevent the sensor from frequent, abrupt pressure changes.. WRNING! Correct humidity values are only possible during gas flow and with a working pressure from 200 to 300 bar. Puracon Filter Monitoring Page - 19 Version: 131114-001

OPERTION Start During commissioning of the display unit, all LEDs light up and the display indicates the unit and software version and the current humidity value. Red - replace filter cartridge (Grenzwert 25mg/m³) Green - filter cartridge OK i Note fter longer standstill of the compressor or after filter change, the yellow or red LED may be illuminated and the digital display may indicate a humidity value higher than 25 mg/m³. This is caused by the remaining humidity in the pipes or by the delayed effect of new filters. Dry unit - only necessary with the option "Compressor- shutdown" Only necessary for installations with auto shutdown of the compressor when the red LED is illuminated. During drying, the compressor operation will be released for 10 minutes regardless of the humidity value. To rinse the system without auto shutdown of the compressor, carry out the drying process. Drying process as follows: ENT The unit must show the humidity value (normal operation), press and hold ENTER button for 3 sec. The display shows "DELY" and the LEDs flash during 10 minutes DELY time. Puracon Filter Monitoring Page - 20 Version: 171114-001

OPERTION Menu settings Menu settings change as follows: ENT + Reset and restart the unit by pressing the UP and DOWN buttons simultaneously and press and hold the ENTER button immediately afterwards Hold the ENTER button as long as MENU will be displayed. MENU MX MIN Mit der UP und DOWN Taste wird der gewünschte Menu-Punkt ausgewählt. Maximum limit value setting (preset 26mg/m³) Minimum limit value setting (preset -3mg/m³) This limit value is deactivated because the sensor will never generate values below 0 mg/m³. PROG CUST D-ON D-OFF Programming Optional function Customising Optional function DELY ON - activates automatic drying during unit start-up. Preset drying time = 10 minutes. Drying time adjustment by the buttons UP and DOWN DELY OFF - deactivates automatic drying. ENT Select the desired menu item by the ENTER button. Select the desired value by the UP and DOWN buttons. ENT Save the selected value by the ENTER button Puracon Filter Monitoring Page - 21 Version: 171114-001

ERROR MESSGES

ERROR MESSGES Error display Exx Error messages treatment as follows: + Reset and restart the unit by pressing the UP and DOWN buttons simultaneously. Code Cause Remedy ERROR 1 undefined software error back to manufacturer ERROR 2 no sensor signal check cable connections ERROR 3 more than one sensor connected connect only one sensor ERROR 4 ERROR 5 ERROR 10 ERROR 11 not used not used internal voltage reference defective back to manufacturer ERROR 12 supply voltage too low; 20-28VDC required supply cable - use a higher cross section or a stronger power unit. ERROR 13 internal overcurrent protection defective back to manufacturer ERROR 14-17 sensor cable short-circuit check sensor cable ERROR 18 sensor voltage too low check sensor cable ERROR 21 internal hardware error back to manufacturer Puracon Filter Monitoring Page - 23 Version: 171114-001

MINTENNCE ND SERVICE

MINTENNCE ND SERVICE Maintenance Work Carry out service and maintenance work exclusively when the compressor is stopped and depressurized. The unit should be leak-checked regularly. Leaks can be preferably localised by using a leak detector spray (if necessary, brush pipes with soapy water). We urgently recommend that all maintenance, repair and installation work must only be carried out by trained personnel. This is necessary because all maintenance work can not be explained exactly and detailed in this manual. Only use authentic spare parts for service work.! Danger Components under pressure, such as the hose ends, can quickly come loose when manipulated and can cause potentially fatal injuries due to the pressure surge. ny work on system parts may only be performed in a pressure-compensated state.! Warning The use of accessories that have not been tested can lead to death or serious injury or damage to the unit. Only use authentic spare parts for service work.! Warning Carry out maintenance or service work when the unit is switched off and protected against unexpected restart. Carry out the following maintenance work every 12 months Maintenance type Quantity Order. No. Visual control for contamination or damage of the sinter filter. Change the sinter filter and the O-ring if necessary. 1 007318 Sensor check - - Puracon Filter Monitoring Page - 25 Version: 270513-001 E

MINTENNCE ND SERVICE Sensor maintenance / check! Danger Do not open when the gas lines are pressurized! Sensor maintenance / check as follows: Loosen cover screws, do not extract. Lift cover at least 1 cm The humidity value should increase fast up to at least 25 mg/ m³. If the humidity value should not increase, return sensor, display unit and cables to the manufacturer for check / repair / calibration! Place cover Place and mount screws crosswise Loosen cover screws, do not extract The sensor maintenance / check is now completed. Return to manufacturer Please return sensor, display unit, all cables as well as a short error description to the manufacturer. free software update and a cleaning will be carried out during check / repair / calibration. Calibration Return only the sensor for calibration. i Note For return delivery to manufacturer ensure sufficient sensor protection. i Note To continue the compressor operation after removing the sensor you can order the connection piece with the order number: 007323 Puracon Filter Monitoring Page - 26 Version: 11/15 001

MINTENNCE ND SERVICE Check sinter filter / replacement of the seal! Danger Do not open when the gas lines are pressurized!! Warning Do not touch or contaminate the sensor. Each contamination can influence the measurement or/and damage the sensor. Sinter filter or seal check as follows: Switch unit off. Loosen and extract cover screws 4 x M8. Remove sensor housing top an place it on a clean surface. ttention: Do not touch or contaminate the sensor. Unscrew the sinter filter out of the sensor housing and check it (visual inspection). Replace a damaged or contaminated sinter filter immediately (seal kit Puracon: 007318). Replace the seal. Place sensor housing top and tighten cover screws. Fig. 1 - Loosen cover screws The sinter filter or seal check is now completed. Fig. 2 - Sensor housing top and bottom Fig. 3 - Sensor Fig. 4 - Rear cover, seal and sinter filter Puracon Filter Monitoring Page - 27 Version: 270513-001 E

DISPOSL Disposal The product must be disposed in accordance with national waste disposal regulations and by an appropriate waste disposal company. Electric and electronic components EU-wide regulations for the disposal of electric and electronic appliances which have been defined in the EU Directive 2002/96/EC and in national laws are effective from ugust 2005 and apply to this device. Common household appliances can be disposed by using special collecting and recycling facilities. However, as this device has not been registered for household usage, it must not be disposed of through these means. The device can be returned to L&W. Please do not hesitate to contact us if you have any further questions on this issue. Puracon Filter Monitoring Page - 28 Version: 260413-001 E