LuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ

Similar documents
INSTRUCTION MANUAL. PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch 3-YEAR WARRANTY

2-YEAR WARRANTY INSTRUCTION MANUAL

INSTRUCTION MANUAL. LUXPRO PSPU721T 2 Heating and 1 Cooling with Dual Fuel Switch 3-YEAR WARRANTY

TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

OWNER S MANUAL Venstar Inc. 08/07

HEAT COOL. Meets Commercial California Title 24

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

INSTRUCTION MANUAL P Heating and 1 Cooling

OWNER S MANUAL Venstar Inc. 08/07

Safety & Installation Instructions

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

OWNER S MANUAL Venstar Inc. 08/07

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Instruction Guide: Thermostat Operation

HEAT HEAT HEAT COOL COOL

EL-TSTAT-8820 Safety & Installation Instructions

ATC32U03 igate Communicating, Programmable Thermostat

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

Safety & Installation Instructions

7-Day. Digital Thermostat. residential. & 2-cool

User s Manual

ATC32U01 igate Communicating, Programmable Thermostat

Safety & Installation Instructions

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

AMANA PHWT-A200 THERMOSTAT

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Installation Instructions

VisionPRO IAQ Total Home Comfort System

VisionPRO IAQ Total Home Comfort System

Installation and Setup Guide

Operation Guide CT80 ENGLISH

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

Commercial Touchscreen Thermostat

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

Siemens RDY2000BN. Start Up Guide

Installation, Start-Up, and Operating Instructions

5+2 Day. up to HEAT COOL

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

Advanced Installation and Configuration Instructions

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

RC-2000 Thermostat Installation Instructions

Owner s Manual ENERGY EFFICIENT, AT A TOUCH OF A BUTTON TSTPRH01, CÔRR 7 TSTWRH01 CÔRR 7C RESIDENTIAL THERMOSTATS. Côrr 7 Series

USER S INFORMATION MANUAL

T-32-TS Touchscreen Thermostat. Installation Manual

Smart Temp. Model

Programmable Thermostat

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

For Quick Set-Up go to Page 14

User Manual. Universal Programmable Smart Wi-Fi Thermostat. For Systems Up to 3 Heat / 2 Cool with Wireless Humidity Control*

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

VisionPRO 8000 with Wi-Fi

Safety & Installation Instructions

RCS Residential Control Systems Inc.

PROGRAMMING AND APPLICATION GUIDE IMPORTANT. ComfortSense 7000 Series. CONTROLS /08 Supersedes 05/08. Shipping and Packing List

Homeowner s Guide / 1

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

USER GUIDE: COLOR TOUCHSCREEN COMMUNICATING WITH HUMIDITY CONTROL THERMOSTAT. Outside Temperature (if installed) Room Temperature.

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

ETN-24-SUPER-PROG (US Program - Celsius)

Safety & Installation Instructions

ZIGBEE COMMUNICATING THERMOSTAT

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Smart thermostat with Humidification/De-humidification control

OPERATING INSTRUCTIONS

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Installation & Operation Manual

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Safety & Installation Instructions

PerFormance Pro t4900 school series InstallatIon GUIDe

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Installation Settings Guide

Installer Guide. WARNING Important Safety Information. 1 Specifications

Model number is located on back of thermostat.

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01

Installation Instructions

THERMOSTATS 126. MECHANICAL THERMOSTATS 1C20 / 1C21 / 1C26 / 1E30 / 1E56 / 1F56... Wiring Diagrams / Configuration

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Read all instructions before proceeding. Store this manual for future reference

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

Installation Instructions

1F Day Day Non-Programmable. Maximum Stages Heat/Cool

What is the Carrier Connect Wi-Fi Thermostat?

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Installation Settings Guide

What is the Carrier Connect Wi-Fi Thermostat?

Transcription:

NEW MULTI-STAGE TOUCHSCREENS Features & Programming

NEW MULTI-STAGE TOUCHSCREENS PSPU721T 2H/1C PSPU732T 3H/2C 7 Day Programmable OR Non Programmable (Simple Mode) Dual Fuel Capable w/optional Outdoor Wireless Remote Temp Transmitter. Manual or Auto Humidity and De- Humidity Control (PSPU732T only) Installer Message Energy Watch Calculates Usage and Dollar Amount. Screen Lockout Much, Much, Much More.. VERY COMPETITIVE PRICING

TOUCH FOR SIMPLE THERMOSTAT On power up, to use the PSPU721 or 732 as a simple non programmable thermostat, touch the screen. To switch from programmable mode to simple mode, remove the faceplate, press & release the reset button on the bottom right. When Touch For Simple Thermostat comes up on the screen touch the screen and the t-stat will switch to Simple mode.

AUTO FAN AUTO 46% 72F - 72.0 + Simple Mode puts the thermostat into non programmable mode where only temperature set point, cool/heat/auto mode, or fan operation can be changed.

TOUCH FOR PROGRAMMABLE THERMOSTAT For Programmable Mode, touch the screen. Now you can use all of the extensive programmable features to configure the thermostat the way you or the consumer wants it.

Run Program or Hold Mode Setting Fan Setting Heat Set Point Outdoor Temp* Current time & date Room Humidity Cool Set Point * With Use of Wireless Remote Transmitter Home screen shows temp set points, date, time, room temp, humidity, and outdoor temp if using optional wireless temp transmitter. Touch the Screen anywhere to advance to Control Screen.

Run Program or Hold Auto, Cool Heat, Emerg Heat or Off Fan Auto, Fan Intermittent or Fan On. Main RUN PROG AUTO FAN AUTO Auto or Manual HUMIDITY MANUAL DHUM 70.0 - HEAT MENU COOL - Programming Current Mode Blinks Installers Message 45 68.0 72.0 46% + + Home Screen Current room temp & humidity Adjust temp and dehumidification settings The Control Screen is for the consumer to make Temp changes, set Humidity to Auto or Manual, set Dehumidifcation set Fan mode put t-stat in Hold or Run Mode access Installers Message. Press Home Screen button to go back to Home Screen. Press MENU to go to Main Programming Screen.

DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Main Menu Programming Screen allows owner to make adjustments, settings and programming choices. Push Date / Time Settings

DATE / TIME MENU 12 24 CLOCK SET TIME / DATE 12 33 PM H M 07 20 08 H D Y Set date & time by pressing each button individually. Press MENU to go back to Main Programming Screen

DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push Program Settings to set daily temperature and fan settings.

PROGRAM MENU MO TU EVENT START HEAT COOL WE TH FR SA SU 1 07 FAN AUTO 30 AM 68.0-72.0 + Press day of week 4 on/off periods per day. Each day can be programmed differently. Fan can be set differently for each period. Each day can be copied to the next.

PROGRAM COPY MONDAY YES NEW TOUCHSCREEN NO After completing each day s program, when you push the next day, the user is asked if they want to copy to the next day. If YES, then you will continue to the following day and be asked the question again, etc. If NO, then you program that day as you wish and proceed on to all the days of the week. Press MENU when complete to go back to the Main Programming Screen.

DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push Energy Watch to see HVAC energy consumption and cost to date.

ENERGY WATCH RESET MENU LAST 30 DAYS 150 HRS COMP. 20 HRS FURN. 120 HRS FAN 290 HRS TOTAL COST $20.30 Energy Watch shows energy consumption for up to 255 days based on parameters set in Advanced Settings. Owner can see energy usage and cost at anytime. Hit the RESET button to zero out.

CLEAN SCREEN DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY By touching the Clean Screen button, you freeze the screen for 15 seconds so that you can wash/wipe it w/o changing any settings. Consult owners manual for maintenance & care

DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push Set Screen to change screen settings.

SET SCREEN BACKLIGHT REVERSE NIGHT REVERSE CONTRAST AUTO ON ON MENU 07 Backlight Can be set to Constant Light or Auto (touch the screen). Reverse Change from B/W to W/B. Night Reverse - Set for Auto screen reverse (chgs at 9PM and 6AM).

DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push Vacation Settings to set parameters for time & temperature while away from the home.

VACATION VACATION BEGIN END HEAT COOL 09 09 20 30 08 08 65.0-80.0 + Input leave (BEGIN) date, return (END) date and heat/cool temp settings.

DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push Filter Monitor to see filter usage in days and to reset after changing filter.

FILTER MONITOR RESET MENU FILTER USED 15 DAYS Filter Monitor Screen shows how many days current filter has been used (based on fan run time). Reset button will set back to zero.

HUMIDITY DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push this button to toggle between Humidify or Dehumidify mode. More detailed settings for humidity control are available in Advanced Settings. (Installer settings)

ADVANCED DATE / TIME PROGRAM CLEAN SCREEN ENERGY WATCH SET SCREEN ADVANCED VACATION FILTER MONITOR DEHUMIDIFY Push & hold the Advanced Settings button for 5 seconds and the installer will be allowed to make additional and more detailed program settings. The following screen will appear when entering Advanced Settings: CAUTION: Altering the system properties in the ADVANCED may affect the performance of the HVAC system and should be performed only by a qualified installer.

ADVANCED NEXT PAGE MENU DAYLIGHT TIME FILTER SECU- RITY ENERGY WATCH INSTALL MESSAGE F OFF Advanced Settings Screen allows installer to set: Daylight Savings On/Off Filter Days Energy Usage Parameters Celsius or Fahrenheit Security level Installers message Press FILTER to set Filter Monitor to Off/On & number of days to monitor.

ADVANCED FILTER MONITOR NEW TOUCHSCREEN MENU FILTER MONITOR OFF Turn Filter Monitor Off or ON. An icon appears on the Home Screen when the Filter monitor is set to ON.

ADVANCED NEW TOUCHSCREEN FILTER MONITOR MENU CHANGE FILTER AFTER 2 MONTH When you turn THE Filter Monitor ON, screen will then ask for the number of months (up to 6), based on fan run time, to notify consumer to change filter. Return to Advanced Settings Screen

ADVANCED NEXT PAGE MENU DAYLIGHT TIME FILTER SECU- RITY ENERGY WATCH INSTALL MESSAGE F OFF Push Energy Watch to set parameters for tracking HVAC energy usage and cost.

ADVANCED NEW TOUCHSCREEN ENERGY WATCH 5 1 MENU 13 5 COMPRESSOR KW FURNACE KW FAN KW C / KWHr Set consumption KW parameters for compressor, furnace & fan, and per hr KW cost. This allows consumer to watch on going HVAC energy costs by pushing the Energy Watch button on the Main Menu Screen. Return to Advanced Settings Screen

ADVANCED NEXT PAGE DAYLIGHT TIME FILTER SECU- RITY ENERGY WATCH INSTALL MESSAGE F OFF Push Security to set level of screen lock MENU preferred.

ADVANCED NEW TOUCHSCREEN SECURITY MENU SECURITY OFF CHANGE PIN FULL LOCK To turn Security on to FULL Lock or PARTIAL Lock, push OFF button. You will be asked for a Pin #. The default Pin # is 1111. To change your Pin # push Change Pin and follow the prompts.

ADVANCED NEW TOUCHSCREEN SECURITY MENU SECURITY OFF CHANGE PIN FULL LOCK Push the Lock button to toggle between FULL Lock and PARTIAL Lock FULL Lock completely locks out the thermostat from unauthorized use w/o the Pin # PARTIAL Lock only allows the changing of the temperature setpoint. Return to Advanced Settings Screen

ADVANCED NEXT PAGE DAYLIGHT TIME FILTER SECU- RITY ENERGY WATCH INSTALL MESSAGE F OFF Push Install Message to input installer MENU message and set frequency of display.

ADVANCED NEW TOUCHSCREEN INSTALL MESSAGE MENU For Service Call ABC Htg at 777-555-4321 1 ABC 2 DEF 3 GHI 4 JKL 5 MNO 6 7 8 9 0 :/- PQR STU VWX YZ OK Message of up to 42 characters. Message can be programmed to appear on a monthly basis. Message can also be accessed by consumer by pushing the icon button on the Control Screen.

ADVANCED NEXT PAGE MENU DAYLIGHT TIME FILTER SECU- RITY ENERGY WATCH INSTALL MESSAGE F OFF Push Next Page to access Advanced settings for system type, cycles rates, staging temps, dual fuel, humidity and more

ADVANCED NEW TOUCHSCREEN Heat Pump 2 Stg HP A/C No Compressor NEXT PAGE PREV PAGE MENU HEAT PUMP 9 ELECTRIC FURNACE HP CUT OFF CUT TEMP Electric Furnace Gas Furnace 2 Stg Gas Furn. Oil Furnace 3 + CYCLE RATE AUTO CHNGE ON 40 Select type of HVAC system. Set Max Compressor Cycle Rate per Hr. (2-9)* Auto Change is minimum temp (dead band) difference between Heat/Cool set points. (1 5 )* * factory settings are recommended PUSH NEXT FOR FURTHER SETTING

ADVANCED NEW TOUCHSCREEN DUAL FUEL NEXT PAGE PREV PAGE MENU HEAT PUMP 9 ELECTRIC FURNACE HP CUT OFF CUT TEMP + CYCLE RATE 3 AUTO CHNGE ON 36 Heat Pump Cut Off is for Dual Fuel applications. By turning the HP CUT OFF to ON, and setting the CUT TEMP (outside), the HP will shut down at that CUT TEMP and the gas furnace will take over. Press NEXT PAGE for further settings

ADVANCED DUAL FUEL NEW TOUCHSCREEN NEXT PAGE PREV PAGE MENU HP OFF WHEN FURNACE ON Allows heat pump to operate with the furnace by changing to the ON position. Press NEXT PAGE for further settings

ADVANCED MULTI-STAGE DIFFERENTIAL NEXT PAGE PREV PAGE MENU 1ST STAGE DIF 2ND STAGE DIF 3RD STAGE DIF OB ENERGIZED NEW TOUCHSCREEN 2 2 2 COOL 1 st Stage Differential is the temp difference from set point that the heat or cool initiates. 2 nd Stage Differential is the temp difference from 1 st stg set point & 2 nd stg start-up. 3 rd Stage Set the reversing valve to energize in Heat or Cool depending on unit design Consult equipment manufacturer s operation/installation manuals before setting these temperature settings. PUSH NEXT FOR FURTHER SETTING

ADVANCED MULTI-STAGE DIFFERENTIAL NEXT PAGE 0 PREV PAGE MENU IF STAGE 1 RUNS NEW TOUCHSCREEN MINUTES TURN ON STAGE 2 This time setting brings on 2 nd stage (heat or cool) if system has not been able to reach the 2 nd stage temperature setpoint. This avoids excessive compressor run time by bringing on the 2 nd stage and full system capacity to meet setpoint. Consult equipment manufacturer s operation/installation manuals before setting these temperature settings. PUSH NEXT FOR FURTHER SETTING

ADVANCED NEW TOUCHSCREEN HUMIDITY CONTROL NEXT PAGE PREV PAGE MENU HUM FAN DH FAN DH REVERSE DHCONTCOMP OFF OFF OFF OFF Humidity Fan When set to ON the fan will run when there is an independent call to humidify. When set to OFF, fan only runs during heating or cooling cycles. De-Humidity Fan Same as above.

ADVANCED NEW TOUCHSCREEN HUMIDITY CONTROL NEXT PAGE PREV PAGE MENU HUM FAN DH FAN DH REVERSE DHCONTCOMP OFF OFF OFF OFF DH REVERSE: ON - DH relay is normally closed when relative humidity is above DH set point. OFF - DH relay is normally open when relative humidity is below DH set point.

ADVANCED NEW TOUCHSCREEN HUMIDITY CONTROL NEXT PAGE PREV PAGE MENU HUM FAN DH FAN DH REVERSE DHCONTCOMP OFF OFF OFF OFF DH CONTROL COMPRESSOR: ON - Thermostat will turn off the air conditioning if either the dehumidify set point or the temperature set point is reached, whichever comes first, both DH relay and compressor will turn off. OFF - DH relay is independent of compressor activity (DH becomes a spare relay and can be used for a variable speed fan or separate dehumidifier or air exchanger)

ADVANCED PREV PAGE MENU HUM + + NEW TOUCHSCREEN 0 TEMP 0 0 This screen allows you to calibrate temperature or relative humidity if found to be off. Temperature accuracy is set at +/-1 degree. It can be adjusted +/- 9.5. Humidity accuracy is +/- 4%. It can be adjusted +/- 20%. Press NEXT PAGE for further settings

De-humidification options for increasing comfort and efficiency HRV/ERV units can be controlled by simply connecting the DH terminal on the thermostat to the terminal DH of the HRV/ERV. Most HRV/ERV units will control properly with the DH REVERSE feature turned off (contact normally open). OPTION 1: In Advanced Settings choose DH ControlComp, set to ON then lower the temperature to a minimum safe set point, then set the desired de-humidity level. Dehumidify will control the compressor (unless minimum temperature set point is reached) whichever comes first.

De-humidification options for increasing comfort and efficiency OPTION 2: Connect terminal DH to Y1 and set thermostat to de-humidify mode. Then regardless of temperature the de-humidification setting will have priority. Caution: This method will run the compressor until the de-humidification level is reached and may cause overcooling.

De-humidification options for increasing comfort and efficiency OPTION 3: Connect the DH terminal to a variable speed fan control, (set DH REVERSE to control the fan so that low speed is activated to de-humidify). This method provides maximum comfort while maintaining the temperature in cooling mode.

Mounting Bracket NEW TOUCHSCREEN Wireless Remote Temp Transmitter Optional Wireless Remote Outdoor Temperature Transmitter for PSPU7 multistage touchscreens. Used for DUAL FUEL & AUTOMATIC HUMIDITY CONTROL of central humidifier. Indoor Receiver (plugs in at bottom of t-stat and mounts under t-stat cover) Optional Outdoor Wireless Remote Temp Transmitter Kit #WTR064

PSPU Thermostat Screen NEW TOUCHSCREEN Wireless Remote Indoor Receiver Plug antenna wire from Indoor Receiver into plug located at bottom right of PSPU t-stat Plug Indoor Receiver into plug located at bottom of PSPU t-stat Push Reset button on Indoor Receiver to initiate communication between Outdoor transmitter and Inside Receiver. Indoor Receiver Unit installed

WIRING LEGEND 12 11 RC DH H C Y2 RH OBW W2 G Y1 TERMINAL EQUIPMENT STANDARD COLOR Y1 First Heat Pump Yellow and/or AC G Fan Green W2 First Stage Furnace White OBW Reverse Valve or Orange Second Stage Furnace RH 24v Heat Transformer Red Y2 Second Heat Pump Unknown and/or AC C Common Blue H Humidity Control Unknown DH Dehumidify Control Unknown Variable Fan Control RC 24v Cool Transformer Unknown 11 and 12 Not Used NOTE: The above colors are standard in HVAC industry. The wiring should be confirmed before installation

TECHNICAL SUPPORT For more information, tech sheets, submittals, please refer to the Instruction or Engineering Manuals, or access the web site at www.luxproproducts.com. Problems with installation or troubleshooting, please call our Technical Support team at (856) 234-8803 Ext. 7 (5:30AM 2PM PST) It is best if contractor is on jobsite when calling Tech Support

LUXPRO S FULL LINE OF RESIDENTIAL & LIGHT COMM L THERMOSTATS OFFER YOU THE BEST VALUE. Thanks for viewing our Touchscreen Presentation