Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Similar documents
AND ARCHITECT SPECIFICATIONS

Conventional Releasing Control Panel

AND ARCHITECT SPECIFICATIONS

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Installation Instructions Model HZM

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

30.45 Electric Release PDRP-2001

Specification/ Data Sheet

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

MR-2602 Two Zone Fire Alarm Control Panel

Air Duct Housings. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

good things in small packages

Addressable Fire Alarm Control Panel

Desigo TM Fire Safety System A comprehensive fire-protection system

Remote NAC Power Supply D7038

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

ANNUNCIATOR FIXED MODULE

LifeAlarm Fire Alarm Control Panels

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

TECHNICAL DATA OBSOLETE

s Notification Appliances

AL800ULADA. NAC Power Extender. Installation Guide

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Release Control Fire Alarm Systems

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

DS7400Xi Addressable Control/ Communicator

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Installation Instructions Model ABHW-4S

LifeAlarm Fire Alarm Controls

June 10, 2002 DF C S2424

Desigo TM Fire Safety System A comprehensive fire-protection system

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

July 14, 1999 DF C-100.

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

MPC-6000 / MPC-7000 / RND-2

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

D7024 Fire Alarm Control Panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Cerberus PRO A comprehensive fire-protection system

ECC-50/100C. Emergency Command Center

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FireNET Plus Wiring Instructions

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

INTELLIGENT FIRE ALARM CONTROL PANEL

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

PSN-1000 & PSN 1000(E) Installation Manual

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Doc. No Part No Rev. U * T*

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Installation, Operating and Maintenance Manual

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

AND ARCHITECT SPECIFICATIONS

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Notification Appliance Circuit Module

Model 17A00 Expansion Enclosure

Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

TrueAlert Addressable Notification

Installation Instructions Model CDC-4

ARCHITECT AND ENGINEER SPECIFICATIONS

Operating Instructions MXL Multi-Line Keyboard/Display Panel

SFC-200 SERIES LED FIRE ALARM PANEL

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

MANUAL RESET ALARM RELEASE BOX

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

'08 Series Notification A liances

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

MS-2410BC. Conventional Fire Alarm Control Panel. Programming, Installation, Maintenance and Operating Instruction Manual

MANUAL RESET ALARM RELEASE

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

Fire Alarm Control/Communicator

Control/Communicator 5110XM. Installation Instructions Installation Instructions Installation Instructions N8026 4/96

Annunciator Modules. for Fire Lite Fire Alarm Control Panels. Document # /30/95 Revision:

Transcription:

s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones Series 3 and 11 compatible detectors and accessories Microprocessor-based control Factory programmed field configurable Two (2) Style Y notification appliance circuits (NACs) 3 Amps notification and auxiliary power 24 and 60-hour battery backup Eight (8) Form C relay-output option 220/240 VAC, 50 Hz power-supply option Remote serial-annunciator option Sprinkler supervisory service Non-silenceable bell service Alarm verification by zone One-person test feature Zone / output bypass feature Subsequent Alarm and Trouble commands with 24-hour reminders Alarm, Trouble and Supervisory last-event records UL 864 9 th Edition Listed & ULC Listed; CSFM Approved System Overview Model SXL-EX from Siemens Fire Safety is a microprocessor-based fire-alarm control panel (FACP) supplied with four (4) conventional zones, and is expandable to eight (8) conventional zones. Model SXL-EX also contains features, such as: field programmability; power-limited circuits, one-person person test; remote annunciation, and sufficient power to meet ADA requirements for signaling. Model SXL-EX is designed to meet the varied firealarm needs for small office buildings, apartment buildings, department stores, hotels, strip malls or anywhere a cost-efficient, general-purpose FACP is required. * Asterisks shown in the second column denote Models DI-3C; PE-11C and PE-11TC, respectively, in Canada Additionally, the SXL-EX can be used to supply remote bell power for larger systems such as the MXL FACP. Initiating Circuits Model SXL-EX has four (4) conventional, Style B (Class B) zones, which are typically compatible with the ionization detector (Model DI-3*); the photoelectric detector (Model PE-11*) and the photo-thermal detector (Model PE-11T*); Siemens Fire Safety thermal, flame and beam detectors, and the MS Series of manual stations. (Please refer to the detectorcompatibility list in the wiring diagram for specific compatibility questions). SXL-EX FACP 7906

System Overview (continued) Any combination of 30 compatible smoke detectors can be combined on a given zone. Any number of thermal detectors, manual stations or other compatible direct shorting devices may be connected to each zone. All of these initiating devices can be mixed on the same zone, providing the total power requirement of the zone does not exceed 9mA supervisory current. Model SXL-EX has the additional capacity to support detector accessories such as: relays, remote alarm lamps and audible bases. Initiating zones can be programmed for many functions. Alarm verification allows detector application in sensitive areas with or without manual stations mixed on the zone, as allowed by code. Manual station operation shall not be delayed on verified zones. Generic zone function allows the NACs in Model SXL-EX to follow the action of a master fire-alarm panel in the facility. Initiating zones can also be bypassed as required for example during construction on the premises. The system is expanded through the (4) four-zone expander (Model SZE-4X), which has an additional four (4) initiating circuits, in addition to relays and open-collector outputs. Notification Appliance Circuits Model SXL-EX has two (2) Style Y (Class B) NACs, each rated at 1.5 Amps. The total power output of the panel, between the two (2) notification circuits and the auxiliary output, is limited to 3 Amps, which is sufficient to provide power for many applications requiring appliances designed to ADA specifications. The SXL-EX notification circuits are power limited to reduce installation costs without the addition of any hardware. NACs can be programmed for various codes. These include: temporal / march time, simplified zone code, and number of rounds. They can also be inhibited during test and programming functions. The two (2) circuits can be individually programmed as non-silenceable. This steady operation can be used for strobes that must continue operation after audible devices are silenced. Relays and Outputs Model SXL-EX has Form C relays for general alarm and trouble commands, rated at 1 Amp, 30VDC. The optional (4) four-zone expander module (Model SZE-4X) has an additional four (4) general purpose, programmable relays at 2 Amps, 30VDC / 120VAC. All remote operations in the fire-alarm system are controlled from Model SZE-4X or the relay module (SRC-8) each of which is situated within the actual Model SXL-EX enclosure. Visual and Audible Indicators Model SXL-EX has visible LED annunciation by zone for alarm and trouble prompts. Additionally, there is a system alarm light-emitting diode (LED) and a system trouble LED. Supervisory zones utilize the zone trouble LED flashing in sync with a system supervisory LED to indicate an abnormal system event. LEDs for AC power bypass and test / program mode are clustered with the system alarm, trouble and supervisory LEDs. A (7) seven-segment display used during testing and programming functions reports a code for each system trouble event. Trouble conditions are also annunciated by a piezo-electric sounder housed inside Model SXL-EX. Remote annunciation is accomplished through a serial connection with Model LED-3 or Model LED-4, (8) eightzone LED annunciators. Models LED-3 and LED-4 display alarm, supervisory and trouble conditions for eight (8) zones. A total of two (2) modules can be attached to each system. Model LED-3 comes with a black enclosure, while Model LED-4 uses a white enclosure. Auxiliary Power Model SXL-EX contains a 1/2 Amp auxiliary power circuit that is used to drive remote devices. The total power for Model SXL-EX, between the auxiliary output and the two (2) NACs, is 3 Amps. Power Supply / Battery Charger The power supply accepts a 120VAC, 60 Hz. Input or, optionally, a 220 / 240VAC, 50 Hz. Input. On loss of AC power, the system switches to battery operation, indicating a loss of power by flashing the AC power LED on the display. Battery capacities of 24 and 60 hours are available. Manual Controls Model SXL-EX has four (4) switches for acknowledging alarm, supervisory and trouble conditions; silencing NACs; resetting the system, and for the drill function. These switches are also used when programming the control unit. Field Programmability and Test Functions The following functions of Model SXL-EX are field programmable, and are generally not programmed in the unit, since the each unit is shipped as received from the factory. Field programming is accomplished through the display, and does not require the use of a computer or any proprietary tools. Initiating Circuits: Alarm Verification by Zone; Zone Bypass; Supervisory Zone, or Generic Zone [when Model SXL-EX is used to provide remote NACs] Note: The default mode is an alarm-causing zone. Notification Appliance Circuits: Non-silenceable, Simple Zone Coding, March Time, Temporal, Silence Inhibit, Cutoff Timers and Reminders Note: The default mode is a steady signal.

System Overview (continued) Outputs: Bypass Outputs / Relays System Programming: Zone to Output Matrix and Password Maintenance System-test features include: one-person test feature, a lamp test, search and clear of the alarm, trouble and supervisory history buffer. Specifications The fire-alarm control panel (FACP) shall be a Siemens Fire Safety SXL-EX; shall utilize conventional zones and shall be microprocessor based and fully field programmable. The base panel shall include four (4) initiating zones, relays for general alarm and trouble and two (2) power-limited notification circuits capable of a total of 3 Amps of power. The system shall be expandable via an expander module (model SZE-4X), which contains an additional four (4) conventional zones; four (4) general-purpose relays and four (4) general-purpose, open-collector outputs. The fire-alarm system shall have the following features: subsequent alarm and trouble prompts; one person test feature; brown out protection, and 24 or 60 hour battery backup. Model SXL-EX also has the following selectable features: supervisory zones; alarm verification by zone; non-latching zones; alarm, trouble and supervisory history, NAC coding, alarm / trouble 24-hour reminder, and zone / output bypass. Any initiating-device circuit shall have the capability of being mapped to any optional output, via the systemprogramming function. The FACP shall be UL / ULC Listed, and meet the requirements of NFPA 72 for local fire alarm control for automatic or manual service, and for sprinkler supervisory and waterflow service. Model SLX-EX shall meet NFPA 72 requirements for central-station service when connected to Model 5128 or Model 5129 digital fire communicator. The system can alternately be expanded through the expander module (Model SZE-8AX), which has an additional four (4) Class A (Style D) initiating circuits. Model SZE-8AX also converts the four (4) initiating circuits and the two (2) notification circuits on the main SXL-EX to Style D (Class A) and Style Z (Class A), respectively. Model Number Details for Ordering Part Number Description 500-695884 EN-SX Enclosure SXL-EX Planning Bill (Black Enclosure) 500-696000 SXL-XLCON SXL-EX-RED Planning Bill 500-696011 EN-SX Enclosure (Red) (Red Enclosure) 600-696000 SXL-XLCON SXL-EX-DF Planning Bill 500-695885 EN-SX Enclosure (Dead Front, 500-696000 SXL-XLCON Black Enclosure) 500-695889 DF-SX Dead Front SXL-EX-INT (International, Black Enclosure) SXL-EX Optional Modules Model Part Number Number Description SZE-4X SZE-8AX SRC-8 RPR-1 SLT-1 MM-SX LED-3 500-695885 EN-SX Enclosure 500-696010 SXL-EX-INT Board, Transformer & Hardware 500-696006 SXL-EX 4-Zone Expander (with outputs) 500-696007 SXL-EX 8-Class A Zone Module 500-692972 SXL-EX 8-Relay Module Remote Polarized 24VDC Relay 500-694998 (with SXL, MXL and System 3 FACPs) 500-093285 SXL-EX Leased Line / Municipal Tie Module 500-696008 Meter Module for SXL-EX 500-693062 LED-3 Annunciator SXL-EX Control Equipment Components SXL-XCON 500-696000 SXL-EX Board, Transformer & Hardware SXL-XCON-INT 500-696010 SXL-EX-INT Board, Transformer & Hardware EN-SX 500-695884 SXL-EX Enclosure, Black EN-SXR 500-696011 SXL-EX Enclosure, Red DF-SX 500-695889 SXL-EX Dead Front Kit. Black Only FT-SX 500-695890 SXL-EX Semi-Flush Trim Kit FT-SXR 500-696104 SXL-EX Semi-Flush Trim, Red SXL-AK 500-696358 SXL-EX / ENS-S Adapter Kit SXL-MAIN 500-695992 SXL-X Main PCB Assembly Pkg. SXL-EX Batteries & Power Supplies BT-33 175-387141 6AH Battery Set BT-34 175-387140 10AH Battery Set BP-61 175-387194 15AH Battery Set PAD-3 599-699189 P/S NAC EXT (6 Amps) PAD-3R 599-699190 P/S NAC EXT, Red PAD-3-MB 500-699080 Main Board Only for PAD-3 EN-PAD 310-099073 Black Enclosure for PAD-3 EN-PADR 310-099150 Red Enclosure for PAD-3 PAD-3-UK 500-648449 PAD-3-UK Upgrade Kit SXL-EX Upgrade Kits SXL-EX-UK 500-363009 SXL-EX-UK F/W Upgrade Kit SLT-1-UK 500-699052 SLT-1F/W Upgrade Kit LED-UK 500-696205 LED-3/4 Upgrade Kit Digital Fire Communicators 5128C 500-693213 4-Channel Slave Communicator 5129 500-693214 4-Channel Communicator [in enclosure] 5230K 500-693215 Programmer / Annunciator [5128 / 5129] TIK-5128 500-693218 (1) Dual-Pack-RJ331X Block & Cord Note: Model BP-61 requires a separate enclosure (i.e. BB-55)

Dimensional Data SXL-EX [with Deadfront Enclosure]

SXL-EX Main Board Connection Diagram Fuse Replacement Model Part Number Number Description F1 105-217858 AC Input, 8 Amps F2 105-224090 Batteries, 15 Amps F3 105-280300 AUX Port, 0.75 Amps Electrical Ratings Alarm / Trouble Relay 244 mmhg., 41 kpa @ 20 C 11.6 (ref std.: Air = 1) Notes: 7. All field wiring must be in accordance with NFPA 70, Article 760. 8. Make no wiring connections while the system is powered. 9. Alarm Relay contacts are shown de-energized, and Trouble Relay contacts are shown energized. Suitable for resistive load only. 10. Auxiliary output rate 0.5 Amps @ +24VDC, filtered. Maximum line impedance of 5 ohms. 11. Combined current output for NAC1, NAC2 and auxiliary outputs is limited to 3.0 Amps. 12. Equipment connected to these terminals must be located within the same room. 13. Refer to the SXL-EX Operation, Installation and Maintenance Manual (IOM): P/N 315-095997, for further details. 1. No T-tapping allowed. 2. Connect standby batteries only to Terminals B+ and B-. The batteries may be installed in either the bottom of the cabinet, or in a UL Listed battery enclosure. 3. In all cases, the Siemens Fire Safety model number is the compatibility identifier, including the control panel, module(s), and all compatible initiating devices. 4. When using the SLT-1 module, not suitable for remote station protected premises service where separate transmission circuits are required for alarm, trouble and supervisory signals. 5. All power-limited wiring requires separation from nonpower-limited wiring. Refer to the SXL-EX Power Limited Wiring Instructions: P/N 315-095994.

Detector Compatibility Detectors Quantity per Loop Base Installation Instructions Part Number DI-3 / 3H 30 DB-3S 315-081943 DI-A3 / A3H 30 DB-3S 315-081943 DI-B3 / B3H 30 AD-31 315-093234 DT-3P-135 30 DB-3S 315-084401 DT-11 30 DB-11 DB-3S with DB-ADPT 315-095429 315-095429 PB-119A 1 PB-1191B 315-095424 PE-3 / 3T DB-3S 315-090875 30 AD-3ILP 315-093234 PE-11 / 11T DB-11 30 DB-3S with 315-094198 DB-ADPT 315-094198 Electrical Ratings Notification Appliance Circuits (NACs) Voltage: Supervisory Current: Alarm Current: 24VDC 1.5mA, max. 1.5A, max. Each NAC is rated at 1.5 Amps, +24VDC. Maximum line impedance, 3.0 ohms per circuit All NACs are supervised. Each NAC must use at least 14 American Wire Gauge (AWG), 300V insulation, color-coded wire. All NACs are power limited per NFPA 70, Article 760 for non-coded applications. Electrical Ratings Initiating Device Circuit Voltage: 16.4 26.4VDC Supervisory Current: 9mA, max. Alarm Current: 120mA, max. Maximum line impedance of 25 ohms per IDC zone All IDC zones are supervised and power limited, per NFPA 70, Article 760 Each IDC zone must use at least 18 AWG, 300V insulation, color-coded wire for low-voltage circuits where local codes require conduit. Where local codes permit, use limited-energy shielded cable rated at 300V. Each IDC zone will support one (1) initiating device in alarm mode. The IDC zone compatibility is an unlimited number of shorting-type devices. For smoke-detector compatibility, see: Compatible Detectors chart. Model SZE-4X Form C Relay 2.0 Amps @ 30 VDC, Resistive Only 0.5 Amps @ 30 VAC, Resistive Only Open Collector 50mA, max. @ 26.4 VDC, max. Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product s installation instructions. Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.usa.siemens.com/fire (SII-FS) Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858 January 2013 Supersedes sheet dated 10/10 (Rev. 2)