SITRANS T temperature transmitters A broad product family for every application. sitrans

Similar documents
Intelligent sensing for every temperature and condition

Temperature Measurement

Temperature measurement with SITRANS T siemens.com/processinstrumentation

SITRANS F M MAG 3100 P:

Operating Instructions Edition 02/2007

Temperature Measurement Transmitters for field mounting

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

7NG , 7NG

SIFLOW FC070 Coriolis mass flow transmitter As easy to install as playing a CD. siflow

Temperature Solutions Line Card

Instrumentation Products and Applications

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

SITRANS F C MASSFLO Flow metering based on coriolis technology. sitrans f

Model 144H. Product Data Sheet , Rev DB February Content

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Electronic Pressure Digest. Pressure and Temperature Transmitters

Is your process protected?

Explore the future of flow measurement. SITRANS FC430 - the market s most compact Coriolis solution. Process Instrumentation. Answers for industry.

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

WIKA Instrumentation (M) Sdn Bhd. Safe and Uncompromising. Easy Testing within the Process - Testing and Calibration Technology.

Engineering Guideline. pac- Carriers Type Universal

Level Measurement Continuous level measurement Ultrasonic transmitters

FAHM Co. Temperature Transmitter PTT74 Series

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Continuous level measurement Ultrasonic transmitters

Explore the future of flow measurement. SITRANS FC430 - the most compact NTEP approved Coriolis flow meter. Process Instrumentation

Level Measurement Continuous level measurement - Ultrasonic transmitters

For Tough Environment. SINAMICS S120 liquid-cooled. SINAMICS drives. Answers for industry.

-REOTEMP s TC/RTD Background - Field Solutions - Product Overview -The REOTEMP difference

Model 144H. Product Data Sheet , Rev DB February Content

Weed Instrument The Only Name You Need to Know for Temperature Measurement

Process Instrumentation. Battery-powered, reliable and cost efficient. SITRANS F M MAG 8000 water meter for long-term accuracy. siemens.

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SIL2-Interface/ -Signal Conditioners Series DuoTec

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Safe area; Zone 1 and Zone 2

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Functional Safety Manual June pointek CLS500/LC500

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Thermostats. Innovative solutions for the toughest requirements

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

EXCELLENCE in Solutions Products Service

Dräger Polytron 7000 Fixed gas detector

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

explosion protection automation global partner of the process industry

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Sitron s CF Line of Flow Switch Monitors

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Dynamisk vægt for væsker Dalum Landbrugsskole Vejeevent 21. august 2018

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Section B Field Instruments

THERMOCOUPLE & RTD INSTRUMENTS. Measuring your world since 1965

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Dew-Point Transmitters and Instruments

Thermal mass fl owmeter Precise and dynamic gas measurement with Sensyfl ow

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Technical Report Proven In Use SITRANS P500

Fire Detection systems. UniVario industrial fire detectors for every job

Safety vacuum drying oven for flammable solvents

Continuous level measurement - Radar transmitters

Rosemount 3051CFP Integral Orifice Flowmeter

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

DISCHARGING. electrostatic innovations. Top-Class Discharging

Density, Concentration and Solids Content. Non-contacting measurement

Thermostats. Innovative solutions to meet the most stringent standards

Flow Measurement. Product overview. 3/2 Siemens FI Overview. Siemens AG Software for parameterization

Product Information to the manual

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

1/2 Siemens FI US Edition. Siemens AG 2008

Dräger Polytron 8000 Stationary gas detector (EC)

Rosemount 4500 Hygienic Pressure Transmitter

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics


Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Products and performance

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

SITRANS T. Temperature transmitter SITRANS TH100. Introduction 1. General safety information 2. Description 3. Assembly 4. Connecting 5.

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Technologies, Solutions, and Applications. Radiation-based Level

Controllers, Indicators & Set Point Programmers

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Thermostats. Innovative solutions for the toughest requirements

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Rosemount 4500 Hygienic Pressure Transmitter. Start

DESCRIPTION AND SPECIFICATION

Rosemount 2090F Hygienic Pressure Transmitter

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

The evolution of accuracy in level measurement

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Transcription:

SITRANS T temperature transmitters A broad product family for every application sitrans

The SITRANS T family High-precision, intrinsically safe, and available for a wide variety of sensors Whether you need a complete temperature measurement system or individual components, you can get everything you need from Siemens. The SITRANS T family Control room transmitters SITRANS TW Field transmitters SITRANS TF and TF2 Head transmitters SITRANS TK-L, TK and TK-H Head transmitter SITRANS T3K PA The field transmitters, control room transmitters and the small, economical head transmitters of the SITRANS T family are highly accurate. They can be quickly connected to a wide variety of thermocouples and resistance thermometers as well as via millivolt sensors and ohmmeters. They are galvanically isolated and have selectable AC rejection. Intrinsically safe and explosion-proof versions are also available You also have a choice between non-intrinsically safe, intrinsically safe and explosionproof versions. And you don t have to wait, either, because our SITRANS T temperature transmitters are generally in stock. Easy configuration For SITRANS TK-H, T3K PA and TW configuration can be done in no time with the userfriendly SIMATIC PDM software package. PDM guides you in a logical sequence through all parameters. It is so intelligent that input errors are virtually eliminated. Temperature transmitter SITRANS TK-L SITRANS TK SITRANS TK-H Types of For sensor head For sensor head For sensor head Connection system Housing Degree of protection IP40 IP40 IP40 Power supply 8 to 35 V DC (28 V for Ex) 6.5 to 35 V DC (30 V for Ex ia) 8 to 35 V DC (30 V for Ex ia) Connectable sensors Pt100 resistance thermometers thermocouples and direct voltage sources thermocouples and direct voltage sources Operator input/settings/ parameter assignments SIPROM T SIPROM T SIMATIC PDM Local display Output Communication HART Certificates/Approvals ATEX EEx ia ATEX EEx n ATEX EEx ia ATEX EEx n FM intrinsically safe ATEX EEx ia ATEX EEx n FM intrinsically safe

SITRANS T3K-PA SITRANS TW SITRANS T SITRANS TF2 SITRANS TF For sensor head Control room transmitter for mounting channel Control room transmitter for mounting channel Field transmitter for direct, incl. Pt100 Field transmitter for separate signal sensor (e.g. thermometer) PROFIBUS PA interface Four-wire technology High-grade steel Varnished die-cast aluminum or high-grade steel IP40 IP20 IP20 IP65 IP68 11 ma bus supply 115 / 230 V UC or 24 V UC 12 to 45 V DC 12 to 30 V DC See Head transmitters thermocouples and direct voltage sources thermocouples, direct voltage sources and direct current sources thermocouples, direct voltage sources and direct current sources Integrated Pt100 thermocouples and direct voltage sources SIMATIC PDM SIMATIC PDM TransWin 3 keys TK-H with SIMATIC PDM TK with SIPROM T LC display LC display Digital PROFIBUS PA 0 to 20 ma, 0 to 10 V, 2 to 10 V PROFIBUS PA, Profile 3 HART Dependent on built-in head transmitter ATEX EEx ia or EEX ib ATEX EEx n FM intrinsically safe ATEX EEx [ia] or EEX [ib] Dependent on built-in head transmitter ATEX EEx d FM intrinsically safe and FM xp

SITRANS TK: The right head transmitter for every task SITRANS T3K PA: With PROFIBUS capability and access to Totally Integrated Automation SITRANS TK The smallest in the family Suitable for every requirement. Small, user-friendly, reliable, safe Thanks to its small size, the SITRANS TK fits into a form B connection head. Internal compensation eliminates the need for cold junction compensation usually required for thermocouples. It is also extremely user-friendly, reliable and safe. Other features are galvanic isolation up to 500 V AC, approval for use in hazardous areas, and usage at temperatures from a bitingly cold 40 C to an unbearably hot +85 C. The bus-capable device with PROFIBUS PA interface can be used in all sectors of industry. The SITRANS T3K PA converts signals from resistance thermometers, resistance-type sensors, And configuration parameters? They are assigned using SIPROM T or, in the case of SITRANS TK-H, also using HART Communicator or SIMATIC PDM. For less exacting demands on measuring accuracy, the SITRANS TK-L is the perfect solution for Pt100 measurements. Lacking galvanic isolation and a universal sensor interface, SITRANS TK-L is an economical alternative to SITRANS TK-H. PROCESS thermocouples and voltage sensors into digital signals. The measured value from the microprocessor is then placed on PROFIBUS PA. Sensor, limit values, failure mode, etc, are programmable. SITRANS T3K PA offers you a wide variety of diagnostic and simulation options. Extremely safe SITRANS T3K PA s power consumption is less than 11 ma. For purposes of safety, the bus current in the event of a fault is limited to less than 14 ma, and an EMC filter prohibits malfunctions in the event of electromagnetic disturbances. The SITRANS T3K PA is also available in intrinsically safe versions EEX ia, EEx ib and FM intrinsic safety. FELD-KOMMUNIKATIONS-PROTOKOLL Fast, error-free configuration Thanks to its compact size, the SITRANS T3K PA fits into a type B connection head with raised hinged lid. Configuration parameters are assigned by means of the user-friendly SIMATIC PDM software package.

SITRANS TF: The field transmitter for rugged industrial environments Because it has IP68 protection, SITRANS TF is used in environments too tough for other transmitters. SITRANS TF is available in your choice of a rugged die-cast aluminum or durable stainless-steel housing. It converts signals from resistance thermometers, resistance-type sensors, thermocouples and voltage sensors into direct current signals in accordance with the sensor characteristic. The remote sensor mount capability of the SITRANS TF allows the electronics to be isolated from possible high process temperatures and vibration. When measuring points are in a tough area, you can install your SITRANS TF in a more easily accessible location. The SITRANS TF is available with local indicating display. There is also a version for explosion-proof hazardous locations. SITRANS TF2 integrates three elements in one device: a Pt100 resistance thermometer in a stainless-steel thermowell, a high-grade stainlesssteel housing with a high degree of protection, and a built-in measuring transmitter with LC display with three configuration pushbuttons.

SITRANS TW: The user-friendly transmitter for the control room SITRANS TW is the result of continuous development of SITRANS T four-wire technology, which has proven itself many hundreds of thousands of times over. The SITRANS TW is designed for DIN rail. With many new functions, it sets new standards for temperature transmitters. Diagnostic and simulation functions let you know exactly what is going on during commissioning and during operation. Thanks to its HART interface, the SITRANS TW can be easily configured to any measuring task with SIMATIC PDM. The simulation function is used to specify physical values, making it possible to test the entire signal path from sensor input to control system without additional equipment. The Min/Max registers are used for acquiring the maximum and minimum values of the process variable. All SITRANS TW control-room devices are available in a nonintrinsically safe version as well, as in an intrinsically safe version for use under the most demanding conditions.

Sensors: A complete range of products! Complete measuring solutions for all applications When it comes to transmitters and sensors, the SITRANS T family can meet your every demand. Regardless of the market and application for which measuring points are needed, we provide all the support and know-how you need. A selection of suitable materials for protective sheath and neck well Does your application involve high temperatures, high pressure or aggressive media, or are your temperature measurements made in fast-flowing media? We can help you find just the right solution. You also have a choice of mounting options. Whether mounting flange, threaded or weld no problem. All conventional sensors With Siemens universal transmitters, you can have the sensor of your choice. Choose your sensor from a wide variety of thermocouples or resistance thermometers. Whatever your choice, we configure the transmitter to the sensor you select. It makes no difference whatsoever whether you want to measure low or high temperatures or whether you use thermocouples or resistance thermometers. Even if you want to measure direct voltages or direct currents, the transducers of the SITRANS T family are your smart choice. The very finest temperature sensors (Pt100, Class A) are available for applications in the pharmaceutical, food & beverage and biotechnology industries. These sensors are equipped with the process connection systems required in these industries, and are designed in accordance with hygiene requirements. Construction and materials meet FDA and EHEDG standards, and are manufactured under GMP guidelines. The temperature sensors can be installed in tubes, containers or as clamp-ons for measuring temperature without media contact.

Your Siemens partners worldwide You will find a list of contacts near you at www.siemens.com/processinstrumentation Subject to change without prior notice 10/03 Order No. E20001-A320-P710-X-7600 DISPO 27900 41C8476 PI.P1.ALLG.52.4.15 WS 03046.0 Printed in Germany Siemens AG 2004 Siemens AG Automation and Drives (A&D) Process Instrumentation and Analytics D-76181 Karlsruhe Phone +49 (721) 595-6997 Fax +49 (721) 595-2239 www.siemens.com/processautomation SITRANS, SIMATIC and SIPROM are registered trademarks of Siemens. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.