Adsorption dryer SDAT

Similar documents
Product Data Sheet Adsorption Dryer DPS (A)

Compressed air preparation Compressed air storage Moisture management. Catalog #1

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Dry compressed air finally exits via a validated GL after-filter preventing the migration of particles into the downstream compressed air network.

A-DRY Heatless adsorption compressed air dryers

Product Data Sheet Adsorption Dryer DPS

Product Data Sheet Refrigeration Dryer DFX

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

ADSORPTION DRYING: WHY?

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Adsorption dryers PDAD

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Adsorption Dryers for Compressed Air

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Rail vehicles without compressed air? Practically inconceivable!

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

MDH Series Air Dryer. User s Guide

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series

Modular Adsorption Dryers

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

pneudri modular dessicant dryer

COMPRESSED AIR TREATMENT

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Adsorption Air Dryers

ASSEMBLY & OPERATING INSTRUCTIONS

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

Industrial Oxygen Generation Plant

CleanAIR Oil free piston compressors

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

With the world-renowned SIGMA PROFILE

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

VSA Series Air Dryer. User s Guide

Service package PDAD- -SP (en) Assembly instructions d [ ]

Heatless Desiccant Compressed Air Dryers

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

ecodry K-MT multitronic

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Modular Adsorption Dryers

Membrane Dryers KMM Series

Assembly and Maintenance manual according to regulation DIN 82079

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

Assembly and Maintenance manual according to regulation DIN DV TB 310-MA, DV TB 330-MA DV TB 510-MA, DV TB 530-MA DV TB 560-MA

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278


Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery 0.26 to 0.80 m 3 /min, Pressures bar

Ventilation Dryer for Hydraulic Units

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Dryer Systems Heatless Regenerating Adsorption Dryers

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Dryer Systems Heatless Regenerating Purification Packages

Membrane Dryers KMM Series

Product Catalogue Edition 1

Dual Tower Heat Reactivated Desiccant Air Dryer

ultra.dry heat regenerated adsorption dryer

Filters & Centrifugal Separators

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

Adsorption Compressed Air Dryer Heatless or heater regeneration

ADK MODEL Air Dehydration System INSTALLATION, OPERATING & MAINTENANCE MANUAL

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Assembly and Maintenance manual according to regulation DIN 82079

Dryer Systems Heatless Regenerating Adsorption Dryers

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Condensate Drain Valves

Propane Heater REMKO PGM 30 REMKO PGM 60

ingersoll rand desiccant dryers

Operating Instructions

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Treatment. Compressed Air. Equipment CONTENTS

Trident Breathing Air System

Downstream Equipment. Intelligent Air Technology

Supplementary Operating Manual for Cutting mill combination

PNEUDRI High Efficiency Compressed Air Dryers.

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

High Pressure Adsorption Dryer HLP PN 25, 0040 to 0125 HLP PN 40, 0050 to 0155

PROBENCH. Manual. A&D PA Process Automation and Instruments. Automation and Drive Engineering. Editor Department Location Telephone Fax

Modular Adsorption Dryers

Efficiency in the smallest space

Cooling with compressed air partial flow: the Heat Regenerating Adsorption Dryer EVERDRY FRP

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Rotary Screw Compressors ASD T SFC With the world-renowned SIGMA PROFILE Air delivery from 0.56 to 5.51 m³/min Pressure 5.

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Quality Components as a basis for Quality Equipment

DRYPOINT AC ADSORPTION DRYERS EFFICIENT, COMPACT, POWERFUL m 3 /h

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

Air. Pressure. Motion. nnnnnnnn

Transcription:

Solutions to your fluid power problems Adsorption dryer SDAT Operating instructions Issue 04/2004 DRUMAG GmbH Fluidtechnik Glarnerstrasse 2 D-79713 Bad Säckingen Telefon: +49 (0)7761 / 5505-0 Fax: +49 (0)7761 / 5505-70 Web: www.specken-drumag.com E-Mail: info@specken-drumag.com

Contents 1. Technical data page 2 2. Safety page 2 3. General page 3 4. Structure and function page 4 to 6 5. Installation page 6 6. Operation page 7 7. Maintenance page 7 8. Ordering spare parts page 7 1. Technical data (general) 1.1 Compressed air section Operating pressure 4 to 10 bar (key data) Compressed air input temperature < 30 C Pressure dew point up to -70 C Input volumetric flow < 350 Nl/min 1.2 Electrical equipment Valve insulation class H Protection class IP 65 Ambient temperature -10 to +50 C Permissible frequency tolerance ± 5 % Permissible voltage tolerance ±10% The operating pressure, maximum permissible volumetric flow and pressure dew point of your adsorption dryer can be read from the type plate. Example: SDAT G70/420 - P5 / 35 / 45 - PS - 230 Pressure dew point (- C) Max. volumetric flow (l/min Norm) Min. operating pressure (bar) 2. Safety Attention notice Attention! This Attention! notice appears at places in this operating manual to which particular attention must be paid. 0404 page 2 of 7 BE_SDAT.doc

Safety instructions The SDAT adsorption dryer has been built in accordance with the state of the art and is safe to operate if installed properly. The assessment of the operating safety within the entire plant must be carried out by the manufacturer of the entire plant. Every person who is involved with the installation and maintenance of the SDAT must have read and understood this operating manual and in particular these safety instructions. Electrical work must be carried out by persons who are qualified to do such work. Working on live parts is forbidden. Unauthorised conversions and alterations lead to the loss of the manufacturer's warranty. The SDAT adsorption dryer is dimensioned in accordance with the design data (operating pressure, temperatures, volumetric flow and desired pressure dew point). Each change of operating pressure, air temperature and/or volumetric flow will lead to a change in the pressure dew point. Appropriate use as intended SDAT adsorption dryer dry compressed air (elimination of water vapour from the compressed air) in accordance with the pressure swing adsorption method (heatless adsorption). Any other use is deemed to be inappropriate. The manufacturer shall not be held responsible for any damage resulting from this. 3. General Fundamentals Work on electrical and pneumatic systems should only be carried out by employees who are qualified to do such work. Only with knowledge of this operating manual can installation errors be avoided and trouble-free operation be guaranteed. If you should experience difficulties despite this, please contact us, our field service employees or our agents. We reserve the right to make technical changes. Copyright The copyright on this operating manual is retained by SPECKEN-DRUMAG. DRUMAG GmbH Postfach 1142 D-79702 Bad Säckingen Tel. 07761 5505-0 Fax. 07761 5505-70 SPECKEN AG Im Lörler 6 CH-8902 Urdorf Tel. 01 7340366 Fax. 01 7342313 0404 page 3 of 7 BE_SDAT.doc

4. Structure and function 4.1 Adsorption dryer 4.11 Structure 1.1 5/2 way solenoid valve (tower switching) 1.2 3/2 way solenoid valve (control of regeneration air) 1.3 tower with molecular sieve and surface filter 1.4 Exhaust muffler for regeneration air 1.6 molecular sieve load spring 1.7 regeneration air nozzle 1.8 Check valve E A Air pressure inlet Air pressure outlet Fig. 1: SDAT The SDAT adsorption dryer is equipped with two direct-switching solenoid valves, which control the main and regenerating air flows. The two towers as well as the base and cover plates are manufactured from anodised aluminium. The direct-controlled solenoid valves are manufactured from high performance components in a very robust design. The 4A molecular sieve is clamped by a stainless steel spring between two 30 µm surface filters and two perforated plates. The molecular sieve is fixed inside the towers even when they are removed. The adjustment of the regenerating air takes place via orifice plates in the base plate. 0404 page 4 of 7 BE_SDAT.doc

4.12 Functional method The SDAT adsorption dryer has two symmetrical towers. While the moist compressed air flows through one tower from top to bottom, whereby the water vapour is almost completely removed from the air, a part of the dried air flows through the second tower from bottom to top, takes up the water vapour again and transports it to the outside. After a specified time, the regeneration is interrupted and the pressure builds up in the tower concerned. Once the pressure level in the two towers is the same, switching takes place from one tower to the other. At the same time, the tower which is now to be regenerated is vented. The tower with the dried molecular sieve is now charged, whilst the molecular sieve in the other tower is regenerated. The amount of regenerating air, and hence the bore in the orifice plate, is determined by the partial pressure drop between adsorption and regeneration and the temperature of the compressed air. The regeneration time is calculated from the selected amount of regenerating air, the dynamically used charging and the desired pressure dew point. 4.13 Valve switching sequence The two solenoid valves control switching between the two towers as well as the regenerating air. It must be noted that no air can flow without electrical control. The switching sequence and the change of pressure with time are illustrated in the following diagram (fig. 2). EV1 5/2 way solenoid valve EV2 3/2 way solenoid valve T1/T2 Adsorption towers DRV1/DRV2 Throttle check valves L solenoid valve actuated 0 solenoid valve not actuated Fig. 2: Switching sequence and change of pressure with time 0404 page 5 of 7 BE_SDAT.doc

4.2 Control The valves are controlled by a built-in programme switching unit. This comprises a drive unit and two programme channels (fig. 3). The drive unit rotates the two program discs via a sliding coupling. Microswitches are actuated via the programme discs. In this manner the mechanical information is converted to electrical switching commands. The programme switching unit allows interval operation of the adsorption dryer. The programme switching unit is installed in a housing which is fastened to the adsorption dryer. Mounting bolts Program channels The overall cycle time is specified by the programme switching unit and is either 4 minutes or 10 minutes. If it should be necessary in exceptional cases to alter the pressure build-up time, this can be done by rotating the two cam discs against one another. Drive unit Fig. 3: Program switching unit Attention! Turn off the power to the device before opening the control housing! To change the pressure build-up time: 1. Turn off the power to the device 2. Remove the hood and the cover of the control housing 3. Unscrew the fixing screws on the programme switching unit and remove the drive unit together with the cam discs 4. Pull off the cam disc assembly from the drive motor 5. Rotate the cam disc pairs against one another in the fine notching Greater overlapping of the two cam disc pairs means upper cam disc lower cam disc pressure built-up time a longer pressure build-up time. One notch is equivalent to about 1.2 seconds (4 min. device) or about 3 seconds (10 min. device) 6. Reassemble the drive unit, tighten the fixing screws 7. Close the control housing cover, fit the hood and screw it tight. 5. Installation Attention! Electrical and mechanical work may only be carried out by qualified persons. - The adsorption dryer must be mounted in a vertical position. - Make sure that the pneumatic connecting pipes are free from all dirt. - The SDAT adsorption dryer is delivered pre-wired and adjusted. The voltage data of the valve coils must be checked before connecting to the mains supply. 0404 page 6 of 7 BE_SDAT.doc

- It is recommended to install a compressed air filter with automatic condensate drain and a sub-micro filter before the adsorption dryer. Depending on the requirements for the compressed air, an active charcoal filter and a further sub-micro filter should be installed after the adsorption dryer. The sub-micro filter must in any case be provided if the small amount of debris from the molecular sieve could cause faults. 6. Operation - The adsorption dryer can only dry the compressed air perfectly if the specified data as shown on the type plate is complied with (operating pressure and volumetric flow). A lower volumetric flow has a positive effect on the pressure dew point. If a lower pressure is required at the consumer, a pressure regulator must be installed after the adsorption dryer. - The ambient temperature should lie between 4 C und 30 C. 7. Maintenance - The activity of the molecular sieve is almost fully retained over a long period of time provided that due attention is paid to the treatment of the compressed air before the adsorption dryer. Oil borne with the compressed air is particularly damaging. It can block openings in the molecular sieve and reduce reactivation during regeneration. - If the pressure dew point is no longer being reached, it is recommended not to draw off any supply air for about 3 to 4 hours. In this manner the adsorption dryer can regenerate itself. - The partial pressure drop between adsorption and regeneration influences the attainable pressure dew point. It is therefore very important that the silencers for the regenerating air do not build up any back pressure due to contamination. The silencers are greatly over-dimensioned. If the pressure dew point is no longer being reached, contaminated silencers could also be a cause. - If, despite the above-mentioned measures, the specified values are no longer being achieved, it is necessary to replace the molecular sieve. Please contact SPECKEN- DRUMAG regarding this. - If the operating pressure needs to be reduced or the volumetric flow increased in relation to the specified values, this can be done if need be by exchanging the orifice plates and adjusting the switching times. Please contact SPECKEN-DUMAG in this case. 8. Spare parts Please quote the type description and the serial number of the device concerned when ordering spare parts. Spare seals are only available in complete sets. 0404 page 7 of 7 BE_SDAT.doc