Duct Temperature Sensors

Similar documents
Duct Temperature Sensors

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Frost Protection Thermostat

Frost Units for air temperature monitoring

Room Temperature Sensors

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

for relative humidity and temperature

for relative humidity and temperature

Room Temperature Sensors

Room Temperature Controllers

Duct Air Quality Sensors

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room Temperature Controller

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

RVL479. Heating Controller. for use with a partner unit

for relative humidity and temperature with calibration certificates

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Wall-mounted room thermostat with LCD

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Use. For 2-pipe fan coils

Semi flush-mount room thermostats

FDBZ290 Air sampling smoke detection kit

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Input module, input/output modules

DM1131 / DM1133 / DM1134 Manual call points

Electronic timeswitch

Output module (230 V)

Room air quality sensors

Room Air Quality Sensors

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Flush-mounted room thermostat

Room thermostats with LCD RDD100..

Input module, input/output module

Multi line separator module

Mimic display driver, LED ribbon cable

FDBZ290 Air sampling smoke detection kit

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Room thermostat with 24-hour time switch and large LCD

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Radio fire detection system

QPM21 Series Duct CO 2 and Air Quality Sensors

District heating controller

QAW70. Room Unit. Building Technologies. for use with heating controllers

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Wireless room thermostat with LCD

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Room thermostat with independent DHW control

Use. Functions. Key function. Other functions

FDOOT221, FDO221, FDT221

Flush-mounted room thermostats

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

RAB21 RAB21.1. For two-pipe fan coils

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

District heating controller

1592P01. for liquids in piping DN

OH720, OP720, HI720, HI722

FDM273 Radio manual call point Mounting

FDCIO223 (ES 45) Transponder

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Room thermostat with Auto Timer, independent DHW

FT2080 Fire terminal (Touch) Mounting Installation

FDCL221-M Multi line separator module

ASA linear smoke detector

FT2080 Fire terminal (Touch) Mounting Installation

Call stations and extensions

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

PRELIMINARY EDITION

Heating Controller. Synco 700

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Application Sheet Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

DT1101A / DT1102A / DO110xA Automatic fire detectors

District Heating Controller

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Room Temperature Controller

DC1192 Input /Output module

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

SWING radio fire detection system

MANDÍK MEASUREMENT AND CONTROL SYSTEM

FDOOT241-A9-Ex Multisensor fire detector

Smart Thermostat RDS110

Room Temperature Controller

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Transcription:

1 761 1761P03 1761P01 1761P02 Mounting flange AQM63.0 QAM2110.040, QAM2120.040 QAM2120.200, QAM2120.600 Symaro Duct Temperature Sensors QAM21... Passive sensors for acquiring the air temperature in air ducts. Use The duct temperature sensors are for use in ventilation and air conditioning plants as: Supply or extract air temperature sensors Limit sensors, e.g. for minimum limitation of the supply air temperature Reference sensors, e.g. for shifting the room temperature as a function of the outside temperature Measuring sensors, e.g. for measured value indication or for connection to a building automation and control system Type summary Type reference Probe length Mounting clamps Sensing element QAM2110.040 0,4 m no Pt 100 QAM2112.040 0,4 m no Pt 1000 QAM2112.200 2,0 m 4 pcs. Pt 1000 QAM2120.040 0,4 m no LG-Ni 1000 QAM2120.200 2,0 m 4 pcs. LG-Ni 1000 QAM2120.600 6,0 m 6 pcs LG-Ni 1000 QAM2130.040 0,4 m no NTC 10k CE1N1761en 2017-12-01 Building Technologies

Accessories (Spare parts) Name Capillary tube clamb for the QAM2120.200 and QAM2120.600 (6 pieces) Monting flange Type reference AQM63.3 AQM63.0 Ordering and delivery When ordering, please give name and type reference, e.g.: Duct temperature sensor QAM2120.040 The sensor is supplied complete with mounting flange AQM63.0 and, if required, mounting clamps AQM63.3. Equipment combinations All systems or devices capable of acquiring and handling the sensor s passive output signal. Function The sensor acquires the air temperature via its sensing element whose resistance changes as a function of the temperature. The signal is delivered to a suitable controller for further handling. Sensing elements LG-Ni 1000 [K] 1400 1771D01 2.0 1771D02 1200 1.0 1000 0.0 800 1.0 600 2.0 50 40 30 20 10 0 10 20 30 40 50 60 70 80 [ C] Pt 100 (class B) 140 1811D05 [K] 0.8 1811D06 120 0.4 100 0.0 80 0.4 60 0.8 2/6

Pt 1000 (class B) 1400 1761D01 [K] 0.8 1761D02 1200 0.4 1000 0.0 800 0.4 600 0.8 NTC 10k 1000000 100000 10000 1000-40 -30-20 -10 0 10 20 30 40 50 60 70 80 [ C] 1811D09 [K] 1.20 1.00 0.80 0.60 0.40 0.20 0.00-0.20-0.40-0.60-0.80-1.00-1.20-40 -30-20 -10 0 10 20 30 40 50 60 70 80 [ C] 1811D08 Legend R Resistance value in Ohm Temperature in degrees Celsius Temperature differential in Kelvin Mechanical design The duct temperature sensor consists of the following components: Two-sectional plastic housing comprised of base with connection terminals and removable cover (snap-on design) Fully active, flexible probe with sensing element which acquires the average temperature The connection terminals can be accessed after removing the cover. Cable entry is made via a grommet which, if required, can be replaced by a cable entry gland M16 (IP 54). After fitting the mounting flange, the sensor can be installed in 6 different immersion positions so that the sensor housing is always located outside the insulation for layers up to 70 mm. The probe with a length of 2 or 6 m is to be fitted across the air duct with the help of the mounting clamps supplied with the sensor. 3/6

Mounting notes Mounting location For supply air temperature control: Downstream from the fan, if the fan is located after the last air handling unit. Otherwise, after the last air handling unit with a minimum distance of 0.5 m For extract air temperature control: Always upstream of the extract air fan As a limit sensor for the supply air temperature: As close as possible to the air outlet into the room For dew point control: Immediately after the spray trap of the air washer Manually bend the probe so that it lies diagonally across the duct or in equally spaced windings across the entire duct cross-section. The probe must not touch the duct wall. The sensor is supplied complete with Mounting Instructions. Mounting positions permitted: not permitted: 1761Z03 Mounting examples min. 200 mm max. 70 mm A 1 2 1761Z05 1761Z07 A 1761Z09 Disposal The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 4/6

Technical data Functional data Degree of protection Electrical connections Directives and Standards Environmental conditions Materials and colors Weight Operating range Sensing element Probe Length Min. bending radius Time constant Dead time Measuring accuracy 40...+80 C for NTC type 50...+80 C other types refer to "Type summary Refer to "Type summary 10 mm 30 s at 2 m/s <1 s Refer to Function" Protection class III according to EN 60730-1 Protection degree of housing With cable entry gland M 16 x 1.5 IP42 according to EN 60529 IP54 according to EN 60529 (not included as standard) Screw terminals for 1 x 2.5 mm 2 or 2 x 1.5 mm 2 Cable entry Grommet Cable entry gland Perm. cable lengths For 5.5...7.2 mm dia. cable M 16 x 1.5 can be fitted refer to Data Sheet of the relevant controller Product standard EN 60730-1 Automatic electrical controls for household and similar use UL EU Conformity (CE) CE1T1761xx *) Operation Climatic conditions Temperature (housing) Humidity (housing) Transport Climatic conditions Temperature Humidity Mechanical conditions Probe Base Cover Mounting flange Clamps Packaging Incl. packaging QAM2110.040 QAM2112.040 QAM2112.200 QAM2120.040 QAM2120.200 QAM2120.600 QAM2130.040 UL 873, http://ul.com/database To IEC 60721-3-3 class 3K5 40...+70 C 5...95 % r. h. To IEC 60721-3-2 Class 2K3 25...+70 C <95 % r. h. class 2M2 Copper, polyolefine Polycarbonate, RAL 7001 (silver-grey) Polycarbonate, RAL 7035 (light-grey) PA 66 (black) PA-GF 35 (black) Corrugated cardboard Ca. 0,3 kg Ca. 0,30 kg Ca. 0,53 kg *) The documents can be downloaded from http://siemens.com/bt/download. Internal diagram B M 1761G01 The internal diagram is identical for all types of duct temperature sensors covered by this Data Sheet. The connecting wires are interchangeable. 5/6

Dimensions Typ L1 L2 max. min. QAM2130.040 400 97 37 QAM2110.040 400 97 37 QAM2120.040 400 97 37 QAM2112.040 400 97 37 QAM2112.200 2000 97 37 QAM2120.200 2000 97 37 QAM2120.600 6000 97 37 Dimensions in mm Drilling plan Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2004 Delivery and technical specifications subject to change 6/6