SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Similar documents
FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Output module (230 V)

Input module, input/output modules

FDCL221-M Multi line separator module

FDCIO223 (ES 45) Transponder

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

Multi line separator module

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Electronic timeswitch

Input module, input/output module

DC1192 Input /Output module

Room thermostat with 24-hour time switch and large LCD

DT1101A / DT1102A / DO110xA Automatic fire detectors

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Conventional Audible Visual Range

XC10 Extinguishing control panels

Fire Products Catalogue

FDA241, FDA221 Siemens ASD

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Cerberus FIT conventional system

ASA linear smoke detector

FDCL221-Ex Line adapter (Ex)

DM1131 / DM1133 / DM1134 Manual call points

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Mimic display driver, LED ribbon cable

Fire control panels FC360

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDA241, FDA221 Siemens ASD

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCW241 Radio gateway Mounting

OH720, OP720, HI720, HI722

Fire Signalling. Signalling Solutions

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

FlexSQUARE Square shaped beacons

EN54-23 Beacons & Sounder Beacons

Room thermostats with LCD RDD100..

FDM273 Radio manual call point Mounting

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

INSTRUCTION MANUAL A131 High Level Audible Warning System

DF1101-Ex Infrared flame detector

Fire alarm devices Product overview. Ensure a safer future

Room Temperature Controllers

Intellia Sounder Bases and Sounder Beacon Bases

Frost Units for air temperature monitoring

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Duct Temperature Sensors

OOH740, OOHC740 Automatic fire detectors

Opal TM AV Devices. Data Sheet. Benefits

DF1151-Ex Infrared flame detector

XP95 Sounder VAD Base

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDOOT221, FDO221, FDT221

Fire control panels FC726 FC726-XA

FC724 Fire control panel

CONTENTS NBM-06 Bell (6") Page 1

Opal TM AV Devices. Data Sheet. Benefits

FC722 Fire control panel

Radio fire detection system

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

Fire Signalling. Signalling Solutions

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

X10 Mini, Midi & Maxi

FC722 Fire control panel

FC724 Fire control panel

Contents. Security. Page

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Building Technologies. FDUL221 en Line tester operating instructions for electricians

1592P01. for liquids in piping DN

Evacuate everyone Sonos Pulse & Nexus Pulse

Control Products & Systems OEM

Room Temperature Controller

FP120-Z1 Power supply kit A (70 W) Technical Manual

Call stations and extensions

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OOH740-A9-Ex Multisensor fire detector

FC723 Fire control panel

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

OOH740-A9-Ex Multi-sensor fire detector

DOW1171 / DCW1151 Radio fire detection system

Room Temperature Sensors

Quick Selection Guide Fire Systems LSN Periphery

FC2020 Fire control panel

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

FDL241-9 Linear smoke detector Mounting Commissioning

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

4) Intrinsic Safety Certification

Flush-mounted room thermostat

Transcription:

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon alarm devices For fire detector and extinguishing systems Loud alarm signal clearly recognizable as a danger signal even in noisy environments Choose from a variety of tones and sound levels Choose beacon ranges and beacon frequencies For indoor and outdoor applications Low current consumption Conforms to EN 54-3 and EN 54-23 Control Products and Systems

RoLP/R/S & RoLP-W For general detection in the event of fire White ABS plastic housing Base adapter for cable entry with cable gland Choose from 32 different tones Automatic synchronization Improved tone quality, reduced risk of confusion Second input for a second tone. This makes two-stage alarm activation possible. Adjustable sound level 93 SHALLOW BASE 63 93 DEEP / U BASE SOL-LX-W-RW & SOL-LX-W-WW (wall mounting) For universal use wherever current consumption plays a central role Ideal for bedrooms or bathrooms and lavatories White or red ABS plastic housing for surface mounting Red or white beacon Very low current consumption Two adjustable signaling ranges ('W-2.4-7.5' and 'W-2.4-2.5') Adjustable beacon frequency (0.5 Hz or 1 Hz) for reduced current consumption 93 66 DEEP BASE 38 SHALLOW BASE 2

SOL-LX-C-WW (ceiling mounting) For universal use wherever current consumption plays a central role Ideal for bedrooms or bathrooms and lavatories White or red ABS plastic housing for surface mounting Red or white beacon Very low current consumption Two adjustable signaling ranges ('C-3-7.5' and 'C-3-5' / 'C-3-3') Adjustable beacon frequency (0.5 Hz or 1 Hz) for reduced current consumption 93 66 DEEP BASE RoLP-LX-WW & RoLP-LX-RW (wall mounting) 38 SHALLOW BASE For universal use wherever current consumption plays a central role Ideal for bedrooms or bathrooms and lavatories White or red ABS plastic housing for surface mounting Red or white beacon Very low current consumption Two adjustable signaling ranges ('W-2.4-7.5' and 'W-2.4-2.5') Adjustable beacon frequency (0.5 Hz or 1 Hz) for reduced current consumption 95 95 2 x 20 135 3

DAB-R & DAB-W Surface-mounted base for the cables for all RoLP and SOL sounder alarm devices. White or red ABS plastic DEEP BASE 93 50 4

Technical data Type RoLP/R/S / RoLP-W RoLP-LX-RW / RoLP-LX-WW / RoLP-LX-RR / RoLP-LX-WR SOL-LX-C-WW / SOL-LX-C-WR Mode of mounting Wall / ceiling Wall Ceiling Wall SOL-LX-W-RW / SOL-LX-W-WW / SOL-LX-W-RR / SOL-LX-W-WR Operating voltage DC 18 28 V DC 18 28 V DC 9 60 V DC 9 60 V Current consumption 15 ma 22 37 ma 10 25 ma 10 25 ma Sound level 102 db(a) 102 db(a) Range 7.5 m 7.5 m 7.5 m Mounting height 2.4 m (max.) 3 m (max.) 2.4 m (max.) Signaling range Stage 1: W-2.4-7.5 Stage 1: C-3-7.5 Stage 1: W-2.4-7.5 Stage 2: W-2.4-2.5 Stage 2 (white): C-3- Stage 2: W-2.4-2.5 5 Stage 2 (red): C-3-3 Volume coverage 135 m 3 132 m 3 135 m 3 Beacon frequency 1 Hz 1 Hz 1 Hz Operating temperature -25 +70 C -25 +70 C -25 +70 C -25 +70 C Protection against polarity reversal Protection category Yes Yes Yes Yes IP54 (IP65 with DAB) IP65 IP33C (IP65 with DAB) IP33C (IP65 with DAB) Housing ABS white or red ABS white or red ABS white or red ABS white or red Beacon color White / red White / red White / red Details for ordering Type Art. no. ation Weight DAB-R S54370-N27-A1 Base adapter - red 0.200 kg DAB-W S54370-N27-A2 Base adapter - white 0.200 kg RoLP-LX-RW S54370-N28-A1 Sounder / beacon alarm device with red 0.250 kg housing and white beacon RoLP-LX-WW S54370-N28-A2 Sounder / beacon alarm device with white 0.250 kg housing and white beacon RoLP-LX-RR S54370-N28-A4 Sounder / beacon alarm device with red 0.250 kg housing and red beacon RoLP-LX-WR S54370-N28-A3 Sounder / beacon alarm device with white 0.250 kg housing and red beacon SOL-LX-C-WR S54370-N29-A2 Beacon alarm device with white housing and 0.100 kg red beacon for ceiling mounting SOL-LX-W-RR S54370-N30-A3 Beacon alarm device with red housing and 0.100 kg red beacon for wall mounting SOL-LX-W-WR S54370-N30-A4 Beacon alarm device with white housing and 0.100 kg red beacon for wall mounting SOL-LX-C-WW S54370-N29-A1 Beacon alarm device with white housing and 0.100 kg white beacon for ceiling mounting SOL-LX-W-RW S54370-N30-A1 Beacon alarm device with red housing and 0.100 kg white beacon for wall mounting SOL-LX-W-WW S54370-N30-A2 Beacon alarm device with white housing and 0.100 kg white beacon for wall mounting RoLP/R/S GBI:1082507 Roshni sounder alarm device, red 0.205 kg RoLP-W S54370-N44-A1 Roshni sounder alarm device, white 0.205 kg 5

Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2014 Technical specifications and availability subject to change without notice. Document no. Edition