General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Technical Information

Technical Information

General Specifications

Technical Information

General Specifications

General Specifications

General Specifications

AO Annunciator Module

General Specifications

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

General Specifications

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

Two global companies, one solution.

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.

Bionics Instrument. Alarm Handling. Gas Alarm Systems

General Specifications

CPS V Cabinet Power System

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

General Specifications

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Annunciator Unit SACO 16 D1. Product Guide

Annunciator unit. Application

FC724 Fire control panel

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

AQ7275 OTDR Optical Time Domain Reflectometer

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Analog Annunciator Unit SACO 16 A3. Product Guide

Vibracon LVL-A* Level limit switch for liquids, compact design

FC723 Fire control panel

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

FC2020 Fire control panel

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

AQ7275 OTDR Optical Time Domain Reflectometer

User s Manual YTA610 and YTA710 NEPSI Certification

Personal ph, ph/orp, Conductivity Meters

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Using ISA100 Wireless to Enhance Plant Safety Penny Chen, Ph.D. Fellow of ISA Yokogawa Corporation of America, US Technology Center

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

FC724 Fire control panel

Personal ph, ph/orp, Conductivity Meters

FC722 Fire control panel

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

PARTS CATALOG MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

General Specifications

Input module, input/output module

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Proven Technology for Safety Instrumentation Systems

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

General Specifications

Touch Screen 1 loop Addressable Fire Alarm Panel

XC10 Extinguishing control panels

EXA Conductivity & Resistivity Analysers

4 Channel Contact Closure SFP DIN Fiber Link System

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

User s. Manual) Model VJUK Limit Alarm for Universal Input

Model A1600 Series Annunciator

Input module, input/output modules

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Dräger Polytron 5720 IR Toxic Gas Detection

Burner control unit BCU 370

INTERNATIONAL STANDARD

Annubar Flowmeter Series

FC700A Fire detection control unit

Four-Door Access Controller User s Manual

Multi line separator module

APPLICATION DATA SHEET

Technical Description Relay Module Flame Detector

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Power Supply Display Module PSDM. Installation and Operation Manual

FC722 Fire control panel

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Fire Damper Interface (24V)

Danfoss gas detection units

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

/8 DIN Level Indicator

EcoSystem H-Series Ballasts

Fire control panels FC726 FC726-XA

Danfoss gas detection units

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Transcription:

General Specifications Model ACUKT1 Cabinet Utility Kit (for Rittal Cabinet, AFV30 ) GENERAL The ACUKT1 Cabinet Utility Kit is used to install in high density a Field Control Unit (AFV30 ), ESB Bus Node Unit (ANB10 ), Optical ESB Bus Node Unit (ANB11 ), and Unit for Optical ESB Bus Repeater Module (ANT10U) in the Rittal TS8 Cabinet. Temperatures and fans in the cabinet can be monitored on HIS by connecting to the HK bus. Kit Components Power Distribution Board with Built-in HKU (Power can be received from two power sources) Door Fan Units: 2 for front door and 2 for rear door Power Supply for HKU and Fan: 2 power supplies Cables Power Supply Bus Unit, Vertical Type (specify with option code) Node Fan Unit (specify with option code) Units that can be Installed in Cabinet (order separately) Field Control Unit: AFV30 ESB Bus Node Unit: ANB10 Optical ESB Bus Node Unit: ANB11 Unit for Optical ESB Bus Repeater Module: ANT10U Applicable Cabinet Rittal TS8 Cabinet (800 (W) x 800 (D) x 2000 (H) mm), Single door or Double door. Number of Units that can be Installed in Cabinet Maximum number of installable units is 14 (7 at the front and 7 at the rear). Maximum number of AFV30 is 1. Status Contact Output When AFV30 is installed: FCU fault contact is output When AFV30 is not installed: A fan, fan power supply or cabinet temperature fault contact is output Three terminals (NC, NO, C) Contact Rating: Rated voltage: 250 V AC/30 V DC or less Rated current: 2 A Rated power: 125 VA or less Power Supply Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC Specify with suffix code Power Consumption 100-120 V AC: 2900 VA (When the maximum number of nodes is installed) 100 VA (Only for ACUKT1) 220-240 V AC: 3320 VA (When the maximum number of nodes is installed) 100 VA (Only for ACUKT1) 24 V DC: 82 A (When the maximum number of nodes is installed) 5 A (Only for ACUKT1) Connection Power Supply: M6 screw terminal connection (Power can be received from two power sources) Contact Output: M4 screw terminal connection Weight Approx. 36 kg (Total weight of the kit components) Regulatory Compliance For the detailed information on the following applicable standards, see Integrated Production Control System CENTUM VP System Overview (for Vnet/IP) (GS 33K01A10-50E). Safety Standards [CSA] (for 100-120 V AC power supply) [CE Marking] (for 100-120 V AC, 220-240 V AC, and 24 V DC power supply) EMC Standards [CE Marking] (for 100-120 V AC, 220-240 V AC, and 24 V DC power supply) [C-Tick Marking] (for 220-240 V AC and 24 V DC power supply) [KC Marking] (for 100-120 V AC, 220-240 V AC, and 24 V DC power supply) Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright Aug. 2011(YK) 3rd Edition Feb. 1, 2014(YK)

2 EXTERNAL DIMENSIONS Node Fan Unit 3.4 209 186.6 1 2 3 4 8.75 20.8 482.6 465.1 441 43.6 31.8 5.9 F01E.ai Fan Unit (for ANFAN) 157.6 153.2 101.8 43 39.5 F02E.ai Dec. 7, 2011-00

3 Door Fan Unit (for ACUKT1) 87 87 184 54 174 47 184 180 152 F03E.ai Power Distribution Board with Built-in HKU 438 224.8 127.8 (384) 159.2 8.75 482.6 465.1 57.15 133 37.7 F04E.ai Dec. 7, 2011-00

4 Power Supply Bus Unit, Vertical Type (for Cabinet Mounting) 11.6 128 112.5 5.9 43.6 31.8 128 112.5 11.6 5.9 43.6 31.8 40 12 40 12 550 630 606 550 630 606 40 40 In the case of 100-120 V AC and 220-240 V AC In the case of 24 V DC F05E.ai Unit Installation Example Rittal TS8 front (for single door) AFV30 2 m Rital TS8 rear (for double doors) ANB10 YCB301 ANFAN-1 Node fan unit YCB301 ANFAN-3 Power supply bus unit, Vertical type 20 c m ANFAN-2 Node fan unit ANFAN-4 20 c m Power distrubution board with Built-in HKU 20 c m HK Bus Door fan unit F06E.ai Figure Example of Installing AFV30D, ANB10D, and ACUKT1 in Rittal TS8 Cabinet Power distrubution board with Built-in HKU Dec. 7, 2011-00

5 HK Bus connection example Optical ESB Bus (Max. 50 km) ACUKT1- L ACUKT1- C AFV30 /HKU ESB Bus ANB10 ACUKT1- R ANB11 /HU HK Bus Transmission Distance: Max. 100 m F07E.ai Aug. 19, 2011-00

6 MODELS AND SUFFIX CODES Cabinet Utility Kit (for Rittal Cabinet, AFV30 ) Model ACUKT1 Cabinet Utility Kit (for Rittal Cabinet, AFV30 ) Suffix Codes Option Codes -C For CPU node (for AFV30 /HKU) -L For ESB Bus Node (for ANB10 ) -R For Optical ESB Bus Node (for ANB11 ) 1 Single door type 2 Double door type 1 Single power supply 2 Dual power supply 1 100-120 V AC power supply 2 220-240 V AC power supply 4 24 V DC power supply 0 Basic type /NFAN1 Node fan 1 (for upper of front side) (*1) [Model: ANFAN-1] /NFAN2 Node fan 2 (for lower of front side) (*1) [Model: ANFAN-2] /NFAN3 Node fan 3 (for upper of rear side) (*1) [Model: ANFAN-3] /NFAN4 Node fan 4 (for lower of rear side) (*1) [Model: ANFAN-4] / -AEP Power supply bus unit, vertical type (*2) [Model: AEPV7D] Note: If the field control unit (AFV30 ) is used in combination with this kit, specify the option code /HKU when ordering AFV30. Note: Be sure to order the HK Bus Cable (AKBHKU) if communication with the HK unit is to be performed between cabinets. (However, the HK Bus Cable is not required for cabinets that are to be connected via an optical ESB Bus.) *1: Order node fan units ( /NFAN ) according to the number of node units (ANB10 or ANB11 or ANT10U) and CPU node to be mounted on the front and rear sides of the cabinet. <Front side> In the case of one CPU node and node units: One CPU node + 0 to 4 node units: /NFAN1 One CPU node + 5 or 6 node units: /NFAN1/NFAN2 In the case of no CPU node: 0 to 4 node units: No node fan unit is required 5 node units: /NFAN1 6 or 7 node units: /NFAN1/NFAN2 <Rear side> In the case of one CPU node and node units: One CPU node + 0 to 4 node units: /NFAN3 One CPU node + 5 or 6 node units: /NFAN3/NFAN4 In the case of no CPU node: 0 to 4 node units: No node fan unit is required 5 node units: /NFAN3 6 or 7 node units: /NFAN3/NFAN4 *2: Specify 1 or 2. If 1 is specified, one unit is mounted on the front panel, and if 2 is specified, one unit is mounted on each of the front panel and the rear panel. Aug. 19, 2011-00

7 MODELS AND SUFFIX CODES OF RELATED PRODUCTS The following related products are included in the ACUKT1 Kit. Order any new products that will be required when performing additional installation or maintenance work. Node fan unit Model ANFAN Node fan unit -1 Node fan 1 (for upper of front side, power supply cable 2.) (*1) Suffix -2 Node fan 2 (for lower of front side, power supply cable 1.6 m) (*1) Codes -3 Node fan 3 (for upper of rear side, power supply cable 2.7 m) (*1) -4 Node fan 4 (for lower of rear side, power supply cable 2.) (*1) Fan Unit (for ANFAN) Model AIP611 Fan Unit (for ANFAN) Door Fan Unit (for ACUKT1) Model ADFAN Door Fan Unit (for ACUKT1) Power Supply Bus Unit, Vertical Type Model AEPV7D Power Supply Bus Unit, Vertical Type (for Cabinet Mounting ) -1 100-120 V AC power supply -2 220-240 V AC power supply -4 24 V DC power supply 0 For Yokogawa cabinet (for AFV40 /ACB51) Suffix Codes 1 For general cabinet (*1) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection *1: To install AEPV7D for ACUKT1, specify General Mounting Type. ORDERING INFORMATION Specify model and suffix codes. TRADEMARKS CENTUM and Vnet/IP are registered trademarks of Yokogawa Electric Corporation. Other product and company names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. Feb. 1, 2014-00