Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Similar documents
Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

CONDENSERS AND CONDENSING UNITS

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

ALL PRODUCTS BROCHURE

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

THE ULTIMATE ROOFTOP SOLUTION

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Water-Source Heat Pumps

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Innovative Design, Performance, & Serviceability

RoofPak Applied Rooftop Systems

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Tulsa, OK Longview, TX

Energy Recovery with Cooling and Heating Model ERCH

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Maverick II Commercial Rooftop Systems 15 to 75 tons

Energy Recovery with Cooling and Heating

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Cultivator & Hybrid Cultivator

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

62DA,DB,DC,DD,DE,DF07-38

Commercial Packaged Rooftop Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

Submittal Summary Page

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Centeral Station Air Handling Unit

The ultimate fresh air solution.

Advance Release September 2009

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

VertiCool Aurora Engineering Guide

RT-OA TM Rooftop Outdoor-Air (DOAS)

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

1.1 This section applies to air handling units for HVAC Systems.

VariCool VAV Engineering Guide

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SKYPAK II, 3 Ton Series, gives you a

Direct Gas-Fired Make-Up Air Models DG and DGX

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

Modular Supply Make-Up Air Unit

C13-Series Engineering Guide

SKYPAK II, 3 Ton Series, gives you a

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

TYPICAL CPA SPECIFICATIONS

30GT FLOTRONIC AIR-COOLED CHILLERS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Double Skin Casing Air Handling Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MACH N-407 Heat Pump Air-Cooled Chiller

XeteX, Inc. All Rights Reserved.

AIR HANDLER SPECIFICATION

Roof Top Packaged Unit (RTU-1) Specification

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Mammoth Water Source Heat Pumps

Addendum Downsville Pike Hagerstown MD April 29, 2016

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Trane Performance Climate Changer Air Handlers. An air handler for every need.

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

EHH SERIES DRAW THROUGH FAN COILS CFM

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

RGE 13 A T - 1 A

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

30GN FLOTRONIC II AIR-COOLED CHILLERS

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

48PGD/E/F/L/M/N PG20-28

50TM TFF COMBINATION HEATING/COOLING UNITS

Transcription:

RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons Chilled water or non-compressorized DX air handling units, from 8,900-75,500 cfm R-410A scroll or R-134a centrifugal compressors Sound attenuating, double wall, foam insulated cabinet construction Walk-in compressor/controls service vestibule Unit access doors with full length hinges and lockable handles Spring isolated, direct drive, backward curved supply fans Blow-through and draw-through configurations Electric, gas, steam, or hot water heating Power exhaust and power return options Factory installed AAONAIRE sensible and total energy recovery wheels Humidity control features, return air bypass and modulating hot gas reheat Option boxes available for field installed components Application Flexibility Minimizes Installation Time and Reduces Cost Make-up Air Applications Up to 100% Outside Air Dehumidification and Filtration Capabilities Easy to Install and Service Factory Installed or Customer Specific Control Options

RL Rooftop/Air Handling Units AAON continuously strives to satisfy the dynamic industry requirement for larger, more energy efficient packaged rooftop equipment. The RL design incorporates the AAON long term commitment and dedication to excel as the premier manufacturer of rooftop equipment. RL units are available in multiple configurations and include many standard features that make AAON synonymous with quality products for any application. Rooftop Conditioners Superior Features Access doors are provided in areas subject to scheduled maintenance. Walk-in doors are constructed with stainless steel piano hinges, perimeter gaskets and zinc cast lockable handles that operate from a single point and open from the outside or inside. Aluminum tread plate floor covering in appropriate equipment access areas for improved durability and safety. Marine service lights for quick and convenient maintenance. Microprocessor controls are compatible with BACnet, Modbus, Johnson N2, LonTalk, and Fox protocols for integration with a variety of controls systems. Polyurethane paint exceeds a 2500-hour salt spray test - over 5 times the industry standard of 500 hours. Refrigerant circuits are provided with removable core filter dryers and isolation valves for ease of service; no need to cut the refrigerant line as is done with brazed in filter driers. Unit specific color-coded wiring diagrams are provided in point-to-point and ladder form and are laminated and permanently affixed inside the control compartment for ease of service. Selectable number of draw-through or blow-through direct drive backward curved plenum fans allows design flexibility for quieter applications and redundancy for applications where unit uptime is critical. H L Full Featured, Energy Efficient, Packaged Rooftop Units to Meet Today s Requirements! W Premier Options VFD driven variable speed scroll compressors are available for load matching cooling and increased part load efficiency. Oil-Free magnetic bearing R-134a centrifugal compressor option provides load matching cooling capacities with quiet, energy efficient operation. Compressor isolation valves are available for improved service efficiency. Double pane viewing windows can be installed in all doors where viewing of operating equipment or interior cabinet is needed. Multiple methods of humidity control including: High Capacity Cooling Coils, Return Air Bypass, and Modulating Humidity Control which provides efficient dehumidification, even with low sensible heat loads, without the temperature swings common with on/off reheat systems. Factory installed, sensible or enthalpy, gear driven economizer allows for free cooling. Multiple high efficiency filtration options, including pleated, cartridge, or bag type, with up to a MERV 14 efficiency rating. Factory installed total and sensible AAONAIRE energy recovery wheels save cooling and heating dollars. Return fans are available for high return static applications. Polymer e-coated coils are available to extend the life of the coils and protect them in corrosive environments. Interior corrosion protection option protects interior components of the unit in corrosive environments. Option boxes are segments of the unit that can be left empty from the factory so that components may be installed in the field without the trouble of working in a crowded cabinet.

Air-Cooled, Water-Cooled, or Evaporative-Cooled Condensers Air-Cooled Condensing Copper tube mechanically bonded aluminum fin condenser coils are slope mounted to prevent physical damage. The outward facing coils are intrusion protected with perforated metal screens. All condenser coils are designed for minimum 10 F of refrigerant sub-cooling. VFD can be installed on the condenser fans for head pressure control and greater operating temperature range, as well as to provide reduced sound levels at off design ambient temperatures. All condenser fans are direct drive, axial flow propeller type and discharge vertically. Evaporative-Cooled Condensing When compared to air-cooled designs these units deliver both outstanding energy efficiency, and significant operational cost savings. Energy cost reduction can be 20 % to 40 % annually dependent on geographic location. Geographic locations that require a central chiller and cooling tower are considered primary locations for application of the evaporative-cooled RL rooftop unit. Factory installed AAON evaporative-cooled condenser, with air-cooled de-superheater and variable frequency drive controlled fans, can be 20-40 % more energy efficient than a comparable air-cooled condenser, can use 22-100 % less water than a conventional evaporative-cooled condenser, and require 22-100 % less chemical usage than a conventional evaporativecooled condenser. Interior of evaporative-cooled condenser is constructed of 304 stainless steel and other non-corrosive materials. De-superheater coils include polymer e-coating for corrosion protection. Water-Cooled Condensing The energy efficient water-cooled units are of particular application value when there exists an accessible water source or when cooling tower water is available. The standard water-cooled RL units include these features: Shell and tube heat exchangers. Each heat exchanger is provided with a removable and cleanable type basket filter. Heat exchanger piping connections are made within the condensing section of the rooftop unit. Air Handling Units The RL also fits the job when units are required without compressors. The unit will be built without a condensing section and walk-in compressor/ control vestibule. All other features and options are readily available. Air handling units may include the following options: Supplied with a DX coil and TXV. Supplied with a chilled water coil in 4, 6 or 8 row. The unit may be specified with any of the heating options to provide a year-round rooftop heating and cooling package. RL Model 045 060 070 075 090 095 100 110 120 125 Air-Cooled EER Water-Cooled EER Evaporative-Cooled EER Up to 10.3 Up to 14.3 Up to 12.7 Width Height Air-Cooled Length* Water-Cooled Length* Evaporative-Cooled Length* 400 375 376 Up to 9.8 Up to 14.0 Up to 12.9 434 395 413 100 Up to 9.9 Up to 13.9 Up to 12.6 508 437 493 134 142 102 506 449 476 135 100 508 437 493 150 Up to 9.9 Up to 13.6 Up to 12.2 155 506 449 476 170 180 181 142 190 210 Up to 9.4 Up to 13.0 Up to 11.9 533 493 548 230 240 *Dimension may vary depending on options selected. All dimensions are in inches. RL Rooftop/Air Handling Units

RL Features Evaporative-Cooled Condenser Interior of evaporative-cooled condenser is constructed of 304 stainless steel and other non-corrosive materials. A de-superheater is installed above the moisture eliminators, spray nozzles and the copper tube condensers are below. Complete Water Treatment To ensure the proper treatment of the water system can be correctly and accurately performed, AAON furnishes a three chemical system and all associated controls, injector pumps and control components. Walk-In Service Vestibule The walk-in service vestibule provides shelter for the maintenance and service personnel while periodic maintenance is performed on the unit. A fluorescent light fixture is furnished in the compartment, controlled by a light switch at the door, and the vestibule can be heated and/or cooled for comfort. Spring Isolators Spring isolators provide sound attenuation for the main blower section. Electric Heat Low watt density, nickel chromium element, electric resistance coils. Modules are 40 KW individual circuit fused with manual reset high temperature switches. AAONAIRE This energy recovery ventilation option can be provided in all model sizes allowing reduced equipment size and operating cost savings while pre-conditioning the outside air being introduced into the conditioned space. Economizer A full line of economizer options are available. All are low leakage with extruded airfoil blades and rubber edge and aluminum end seals. Gas Heat Exchanger Constructed from stainless steel with patented dimple design to maximize efficiency at all inlet air conditions. Burners have electronic ignition and safety shutdown. Evaporator Coils Each evaporator coil has a TXV. A double sloped drain pan is provided for positive drainage. Tubing is dressed and structurally supported. Blower Section Single or multiple direct drive, single inlet plenum fans with spring isolation on the entire assembly allows optimization of fan diameter, sound level and efficiency.

RL Rooftop/Air Handling Units Water-Cooled Condenser R-410A Scroll Compressor Air, Water or Evaporative-Cooled Rooftop Units. The Ultimate in Energy Efficiency. SCR Controlled Electric Heat VFD Controlled Direct Drive Fan Assembly Walk-in Service Vestibule AAONAIRE Integral Energy Recovery Wheel Standard Double Sloped Stainless Steel Drain Pan Water-Cooled Condenser Rooftop Unit Lockable Handles Walk-in doors are constructed with stainless steel piano hinges, perimeter gaskets and zinc cast lockable handles that operate from a single point. Power Return Blower Power Exhaust Fan Outside Air Intake Hinged Access Doors Full length stainless steel piano hinges provide improved reliability over single point hinges. Optional Exhaust and Return Fans The axial flow and plenum power exhaust and return fans are directly driven by the motor.

Patented De-Superheater Design reduces water consumption and chemical treatment Evaporative-Cooled Condenser Rooftop Unit Blow-Through Design Three Tank Water Treatment System AAONAIRE Energy Recovery Wheel Standard Double Sloped Stainless Steel Drain Pan Outside Air Intake Rigid polyurethane foam panel construction provides greater thermal efficiency and improved indoor air quality Power Exhaust Fan Draw-Through Design Sloped Condenser Coils with Outer Coil Protection Gear Driven Economizer Stainless Steel Heat Exchanger with Patented Dimple Design Outside Air Intake Air-Cooled Condenser Rooftop Unit High Efficiency Filters Power Return Fan

Heating and Cooling Options The RL can be configured as either a drawthrough or blow-through arrangement with supply or return fans. The supply blower assemblies are direct drive, unhoused, single inlet, single width, fans with spring isolation. The AAON ECat32 selection software easily permits a selection for constant speed or variable speed applications. The software determines the most efficient alternatives for the application as a function of fan quantity, fan diameter, fan blade width and rpm. Inlet and outlet sound ratings are provided for each combination of fans and unit inlet and outlet sound ratings are determined for the overall unit configuration. Multiple fans can provide improved reliability, greater efficiency, lower sound levels, and greater service options. Gas Heat A system unique to AAON, the all stainless steel design construction assures dependable, long-term functionality. Through elimination of the need for internal turbulators, AAON s unique design assures trouble free service, capacity, and efficient performance. Up to 12 individual burners may be utilized. The total input of the 45-125 and 135 ton units is greater than 2580 MBH while the 134 and 150-240 ton units are 2880 MBH. Each burner may be supplied with 2 stage gas control valves. Stainless steel heat exchanger has a 10 year prorated warranty. Electric Heat Electric resistance heating coils are open type with low watt density nickel chromium elements. The heating modules are 40 KW with individual circuit fusing and a manually reset high temperature limit switch. Chilled Water Coils Chilled water coils are constructed of 1/2 seamless copper tubing mechanically expanded to bond with the aluminum fins. Tube sheets are constructed of 16 GA galvanized steel and extruded holes for the copper tubing. All headers are constructed of heavy wall copper tubing with either spun or die formed end caps. Chilled Water coils are available in 4, 6 or 8 rows deep in two different face areas for each cabinet size. Hot Water or Steam Preheat Coils When job site conditions require, coils are available to precondition the outside air. 1 or 2 row hot water or steam coils may be supplied to match the system requirements. Variable Capacity Compressors RL unit are available with variable capacity compressors which allow the unit to be able to provide a consistent supply air temperature at all operating conditions. Variable capacity and VFD driven variable speed R-410A scroll compressors are available for load matching cooling capabilities and increased part load efficiency. Variable capacity R-134a centrifugal compressors provide load matching cooling capabilities, with quiet energy efficient operation. During part load operation, reducing compressor capacity saves system operating costs. Flexibility The wide range of unit sizes, capacities, airflow rates, as well as, the standard design features and the many available options make the RL the wise selection. A Trend Setting Design In the past when greater airflows were required, the diameter of the single plenum fan was simply increased to meet the requirement. This results in higher tip speeds, which also means higher sound levels. With the AAON RL, the greater airflow rates can be accomplished with multiple fans of smaller diameter, which inherently will be quieter than a single larger diameter fan. All the fans are also directly driven by the motor, which eliminates the drive belt assembly and associated requirement for maintenance. The entire assembly is then spring mounted to further enhance the vibration isolation and reduce sound transmission. VFD Driven Variable Speed Scroll Compressor Hot Water and Steam Heat Coils Hot water and steam coils are available in 1 or 2 row configurations with 4 different face areas to meet job requirements. Oil-Free Magnetic Bearing Variable Capacity RL Centrifugal Compressor Rooftop/Air Handling Units

AAON Environmentally Friendly HVAC Product Family Custom & Cataloged Air Handling Units (800-200,000+ cfm) Condensers & Condensing Units (2-230 tons) Chillers (Air-Cooled, Evaporative- Cooled, Heat Pumps) (5-540 tons) Rooftop Units (2-240 tons) Outdoor Equipment Rooms (Chillers, Boilers & Pumps) Self Contained Units (2-70 tons) Heating and Cooling for... Auditoriums Convenience Stores Health Clubs Healthcare Facilities Homes Lodgings Manufacturing Museums & Libraries Natatoriums Office Buildings Restaurants Retail Stores Schools Supermarkets Residential Systems (2-5 tons) Geothermal & WSHP Units (2-230 tons) Air-Source Heat Pumps (2-230 tons) Defining Quality. Building Comfort. 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. RL V20770 120530