Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Similar documents
Job Name Control Systems Description Date

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Virginia Tech Standards for Building Automation System

Digital Precise Air Control - DPAC

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

HVAC Controls Upgrades: Requirement Details ( )

DDC POINT LIST. 004 Harry Griffith Hall. RFP #PW17-2 Exhibit J Page 1 of 9 AHU 1 BOILER BOX DUAL DUCT MIXING. Building: HUMBOLDT STATE UNIVERSITY

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Technical Assignment 3 11/15/04. Executive Summary

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Sequence of Operations (excerpt)

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

AHU Air Handling Unit Fundamentals. j.ilangumaran

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Programming Guide. Signature Series, Ton Modular Series, Ton. Models AO and later Design Sequence

9/18/2017. Nicholas Thornton, CEM. Systems: HVAC, Electrical, and Technology. Overview. Today s Goals Introductions HVAC Electrical Technology Q&A

DIGI-VAV APPLICATIONS

DX-9100 Applications from Engineering Services

4. OVERVIEW OF MECHANICAL SYSTEM

CHAPTER 4. HVAC DELIVERY SYSTEMS

COMcheck Software Version Review Mechanical Compliance Certificate

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

terminal unit accessories

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

HVAC Mandatory Provisions Part II, Page 1

Submitted to. Texas A&M University at Commerce The Texas A&M University System. Submitted by. Guanghua Wei Craig Campbell David Claridge Dan Turner

Your Home. Jacco & Assoc.

Reference Guide for Microprocessor Controller

HVAC Controls Upgrades: Requirement Details ( )

HVAC 101. H V A C S y s t e m s

RCE # April 30, 2013 Centennial School District William Tennent HS, Region 3 ES, Region 1 ES, Region 2 ES

An HVAC Audit of the Canberra Institute of Technology

Reference Guide for Microprocessor Controller

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY

MicroTech Rooftop/RMC

Energy Recovery with Cooling and Heating Model ERCH

Appendix 13. Categories of Cooling and Heating systems

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Voyager. 12½ to 25 Ton Light Commercial Packaged Units with ReliaTel Microprocessor Controls

MEP CONDITION ASSESSMENT

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

Song Deng, P.E. Assistant Director Energy Systems Laboratory Texas A&M University College Station, TX

Summary Comparison of Simulation Program Features

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Computing Services Center

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

Strategies for Building Energy Efficiency

Feature Summary. I. System

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

To: Steve Ardolf, MSU Mankato From: Chris Plum, CEE. CC: Tim Ellingson, CEE. Angela Vreeland, CEE Dan Briese, MSU Mankato Date: April 21, 2014.

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

COMcheck Software Version Mechanical Compliance Certificate

IntelliPak. Commercial Self-Contained Modular Series, Ton. BO and later Design Sequence

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

Vapor-Compression Refrigeration

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

1.0 Digital Controller

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Dehumidifying with Dedicated Outdoor Air

Verasys System Operation Overview Technical Bulletin

FINAL REPORT INFRASTRUCTURE MASTER PLAN UPDATE. Harper College. Palatine, Illinois

GARCIA GALUSKA DESOUSA Consulting Engineers

RT-OA TM Rooftop Outdoor-Air (DOAS)

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

Agenda and Objectives

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Reference Guide for Microprocessor Controller

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Balancing Energy & Performance in Healthcare. Dan Koenigshofer, PE, MSPH, HFDP, SASHE Dewberry Engineers Inc. Raleigh, NC - November 12, 2014

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

QUANTITY EQUIPMENT MANUFACTURER MODEL NUMBER SERIAL NUMBER

Building Systems: HVAC

ONLINE REGISTRATION: > Commercial > Products & Systems > Education & Training > Training - Class Finder > Filter State: Indiana OR CALL

GARCIA GALUSKA DESOUSA Consulting Engineers

Transcription:

Rooftop Units CV Reheat RTU Reheat Reheat system RTU, serving electric reheat coils, w/dehumidification cycle & RA CO2 override of OAD CV Single Zone RTU SZ (from PC) RTU SZ Generic RTU SZ Multiple Units RTU SZ Prog Thermostat RTU SZ Short Version RTU SZ Trane Tracer RTU SZ Trane with Zone Sensor Single zone RTU, controlled by a programmable thermostat Single zone RTU, generic description, with power exhauster Single zone RTUs, one sentence descriptions of multiple units for a single project Single zone RTU, controlled by a programmable thermostat, with smoke detector Single zone RTU, short description of programmable thermostat control Single zone RTU, typical control of a networked Trane RTU on a Tracer system Single zone RTU, typical control of a stand-alone Trane RTU Misc. Economizer Economizer (from PC) Refrig Cycle (from PC) T7300-Q7300 Short description of economizer operation as it applies to packaged RTUs Long description of economizer operation as it applies to packaged RTUs Basic description of the refrigeration cycle as it applies to packaged RTUs RTU operation of the Honeywell T7300 programmable thermostat, with the Q7300 switching subbase VAV RTU VAV Elec Heat VFD RTU VAV Gas Heat IGV's RTU VAV Trane Intellipak RTU VAV Traq Dampers VAV RTU, DX cooling and electric heating, supply fan VFD, generic description VAV RTU, DX cooling and gas heating, supply fan IGVs, Trane RTU and VAV boxes (Tracer) VAV RTU, Trane Intellipak, point style sequence of operation of the whole VAV system VAV RTU, elaborate description of the operation of Trane's Traq Dampers RTU VAV Two Units One System Two VAV RTUs serving the same ductwork distribution system, version 1 RTU VAV Two Units One System Two VAV RTUs serving the same ductwork distribution system, version 2 Wednesday, December 07, 2005 Page 1 of 7

Make Up Air Units Built Up MAU Blt Up HW MAU Blt Up HW CHW Elec MAU Blt Up Steam Built up MAU, 100% OA, hot water preheat coil and circ pump, chilled water coil, electric reheat coil Built up MAU, 100% OA, hot water coil and circ pump, no cooling, combustion air unit Built up MAU, 100% OA, steam coil with face/byp dampers, no cooling, microprocessor-based control Packaged 100% OA MAU 100% OA Generic MAU 100% OA with CHW 1 MAU 100% OA with CHW 2 MAU 100% OA with DX 1 MAU 100% OA with DX 2 MAU 100% OA with DX 3 MAU 100% OA with VFD Packaged MAU, DA control with space reset, short description Packaged gas-fired MAU, DA control, with CHW coil and separate cooling DA control system Packaged gas-fired MAU, DA control, with CHW coil, integration of htg and clg via digital controller Packaged gas-fired heating / DX cooling MAU, factory controls with some BAS integration Packaged gas-fired heating / DX cooling MAU, factory controls Packaged gas-fired heating / DX cooling MAU, factory controls Packaged gas-fired MAU, with supply fan VFD and space pressure control Packaged 80-20 MAU 80-20 1 MAU 80-20 2 Packaged gas-fired MAU, DA control with space reset, space pressure control of OA/RA dampers Packaged gas-fired MAU, DA control with space reset, space pressure control of OA/RA dampers Fan Coil Units Built Up FCU Blt Up Dual Temp FCU Blt Up DX Elec FCU Blt Up DX Elec HW FCU Blt Up DX HW Built up FCU, one coil for both heating and cooling, controlled by a programmable thermostat Built up FCU, DX clg, electric and hot water htg coils, controlled by a non-programmable thermostat Built up FCU, DX cooling and electric heating, controlled by an electronic thermostat Built up FCU, DX cooling and hot water heating, controlled by an electronic thermostat Wednesday, December 07, 2005 Page 2 of 7

Packaged FCU Four-pipe FCU Split System FCU Two-pipe 1 FCU Two-pipe 2 FCU Two-pipe 3 FCU Two-pipe 4 Packaged FCU, chilled water cooling and hot water heating, controlled by a unit mounted thermostat Packaged FCU, DX cooling and electric heating, controlled by a remote mounted thermostat Packaged FCU, one coil for both heating and cooling, controlled by a unit mounted thermostat Packaged FCU, one coil for both heating and cooling, controlled by a non-programmable thermostat Packaged FCU, one coil for both heating and cooling, controlled by a unit/wall mounted thermostat Packaged FCU, one coil for both heating and cooling, controlled by a unit mtd stat, with electric heat Air Handling Units CV Reheat AHU Reheat (from PC) AHU Reheat Long AHU Reheat Short Reheat system AHU, hot and chilled water coils, supply and E/R fans, night setback and morning warmup Reheat system AHU, hot and chilled water coils, supply and exhaust fans, 24/7 operation Reheat system AHU, short descrpition, night setback CV Single Zone AHU SZ (from PC) AHU SZ CHW Steam AHU SZ Dual Temp AHU SZ DX no Heat Single zone AHU, hot and chilled water coils, supply and E/R fans, night setback Single zone AHU, steam and chilled water coils, supply and exhsuat fans Single zone AHU, single coil for both hot and chilled water, supply fan, night setback Single zone AHU, DX coil, supply and E/R fans, safeties and limits, smoke evacuation mode Smoke Purge Smoke Purge Point style sequence of a particular AHU smoke purge configuration VAV AHU VAV (from PC) AHU VAV CHW HW VFD AHU VAV CHW IGV's AHU VAV CHW Steam VFD AHU VAV DX VFD VAV AHU, hot and chilled water coils, supply and E/R fans, night setback and morning warmup VAV AHU, hot and chilled water coils, supply and exhaust fans w/vfds, safeties and limits, NSB, MWU VAV AHU, chilled water coil, supply fan w/igvs, interlocked exhaust fan, no economizer (fixed OA, RA) VAV AHU, steam and chilled water coils, supply and E/R fans w/vfds, night setback and morning warmup VAV AHU, DX coil, supply fan w/vfd, E/R fan, safeties and limits Wednesday, December 07, 2005 Page 3 of 7

VVT Systems VVT Systems VVT Airlink VVT Carrier VVT System (from PC) VVT Trane Airlink rooftop unit zoning system Carrier rooftop unit zoning system (VVT) Generic description of rooftop unit zoning system Trane rooftop unit zoning system (Varitrac) VAV & Fan Powered Boxes Cooling with Reheat VAV CV (from PC) VAV Elec Htg (from PC) VAV HW Htg (from PC) Constant volume terminal unit, with electric/hot water reheat VAV box with electric reheat VAV box with hot water reheat Cooling-only VAV Clg Only (from PC) VAV box, cooling-only Fan Powered FP Parallel (from PC) FP Series (from PC) FP Unocc Mode (from PC) Parallel fan powered box with electric/hot water heat Series fan powered box with electric/hot water reheat Unoccupied mode operation of a series or parallel fan powered box (one version) Reheat Coils Reheat Coils DH Electric DH Hot Water DH Steam Electric duct heater in a reheat application Hot water coil in a reheat application Steam coil in a reheat application Exhaust Fans Exhaust Fans Exhaust Fans Various Control One/two sentence descriptions of various exhaust fan control methods Wednesday, December 07, 2005 Page 4 of 7

Pumps Pumps Auto Alt Auto Backup Each Half Capacity Manual Alt & Backup Manual Alt Auto Backup Pump Seq (from PC) Two full sized pumps, automatic time-based alternation, automatic backup upon failure Two pumps, each sized for half capacity Two full sized pumps, manual alternation, non-automatic (manual) backup upon failure Two full sized pumps, manual alternation, automatic backup upon failure Two full sized pumps, automatic alternation and automatic backup upon failure, detailed description Boilers & Chillers Boilers HW Boilers (from PC) Hydrotherm Control Single HW Boiler Two Blrs, 3-way Valve, Ext Ctrl Two Boilers & 3-Way Valve Two Boilers External Control Multiple HW boiler system, generic description Multiple HW boiler system, controlled by the Hydrotherm Model S boiler controller Single HW boiler system, operated via its own factory controller Multiple HW boiler system, operated via external controller, with 3-way valve for reset control Multiple HW boiler system, operated via external ctrlr., 3-way valve for reset, and 2-way press. byp. valve Multiple HW boiler system, operated via external controller Boilers & Chillers Dual Temp Auto Chgover 1 Dual Temp Auto Chgover 2 Dual Temp Auto Chgover 3 Dual Temp Manual Chgover Four-pipe System Boiler/chiller plant, primary-secondary system, dual-temp with motorized valves for auto changeover Boiler/chiller plant, primary-secondary system, dual-temp with motorized valves for auto changeover Boiler/chiller plant, primary-secondary system, dual-temp with motorized valves for auto changeover Boiler/chiller plant, primary-secondary system, dual-temp, motorized valves for chgvr, manually initiated Boiler/chiller plant, separate piping distribution systems, for hot and chilled water Chillers Single Chiller Two Chillers Complex System Two Chillers Integral Control Single air cooled chiller system, operated via its own factory controller Multiple water cooled chiller system, for a complex process application Multiple air cooled chiller system, both chillers operated via their own factory controllers. Misc. Fill System Self-contained pressure fill system Wednesday, December 07, 2005 Page 5 of 7

Heat Exchangers Heat Exchangers HE One Valve Control HE Two Valve Control Steam to hot water heat exchanger, controlled via a single steam valve Steam to hot water heat exchanger, controlled by two steam valves Unitary Heating Equipment Baseboard Heaters BBD Electric Integral Control BBD Electric Remote Stat BBD Electric with VAV BBD Hot Water Thermostatic Val BBD Hot Water with VAV BBD Steam Thermostatic Valve BBD Steam with VAV Electric radiator controlled by an integral thermostat Electric radiator controlled by a remote thermostat Electric radiator zoned and controlled via a VAV box Hot water radiator controlled by a self-contained thermostatic control valve Hot water radiator zoned and controlled via a VAV box Steam radiator controlled by a self-contained thermostatic control valve Steam radiator zoned and controlled via a VAV box Cab Unit Heaters CUH Electric CUH Hot Water Electric cabinet unit heater controlled via factory control packages Hot water cabinet unit heater controlled via factory control packages Unit Heaters UH Electric UH Gas Fired UH Hot Water UH Hot Water (Dual Temp) UH Steam Electric unit heater controlled by an integral thermostat Gas fired unit heater controlled by a remote thermostat Hot water unit heater served by a dual-temp system, controlled by a remote thermostat Hot water unit heater controlled by a remote thermostat Steam unit heater controlled by a remote thermostat Computer Room Units Air Cooled CRU Air Cooled Short description of a split system operated via factory controls Wednesday, December 07, 2005 Page 6 of 7

Fluid Cooled CRU Fluid Cooled of two fluid cooled A/C systems Water Source Heat Pumps Water Source Heat Pumps WSHP System Heat pump core water system Miscellaneous Miscellaneous CO & CO2 Mon Sys CO Mon Sys 1 CO Mon Sys 2 CO Mon Sys 3 Glycol Sys Ref Mon Sys Tracker System Centralized monitoring systems with remote sensors wired back to central panels Centralized monitoring system with remote sensors wired back to a central panel Centralized monitoring system with remote sensors wired back to a central panel Stand-alone detectors with contacts wired in parallel to start fans and open dampers Glycol system consisting of pumps, drycoolers, heat pumps, and computer room A/C units Refrigerant monitoring system consisting of monitor/sensor, exhaust fan, and OAI damper Brief description of Trane Tracker system supervising the operation of packaged rooftop units Wednesday, December 07, 2005 Page 7 of 7