INSTALLATION AND SERVICE INSTRUCTIONS. Tuthill atlantic fluidics OSR-5, 10,15 & 20. Oil sealed liquid ring vacuum pump

Similar documents
The Experts in Vacuum Solutions

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

MODEL MW200 MODEL MW600 AIR DRYER

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

CHILLER. Operator s & Installation Manual

SECTION STEAM CONDENSATE PUMPS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

CHILLER MODEL: CH1500, 2000 AND 3000

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION AIR COMPRESSORS AND ACCESSORIES

A B A B4

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

VENTLESS DOOR-TYPE DISHWASHER

Refrigerated Air Dryers

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

Oil burners fuel unit with solenoid valve

CH250 AND CH251 CHILLERS

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

OPERATING INSTRUCTIONS

OIL FILTRATION SYSTEMS, INC. 111 Parkway Drive, Boerne, Texas Phone: Web: oilfiltrationsystems.com.

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

VAC-U-DRY VACUUM DEHYDRATOR

CHILLER. Model CH3000. Operator s & Installation Manual

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

SENTRA Series Water Unit

Air Cooled Oil Coolers

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

CPF PRODUCT DESCRIPTION

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

CHILLERS. Operator s & Installation Manual

Precise Temperature Control; Compact Footprint

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

MAC-120HE-03 Air-Cooled Chiller

KIC Air Curtains. Technical Guide

Technical Specifications & Pricing

Liebert InteleCool Warranty Inspection Check Sheet

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Oil burners fuel unit with solenoid valve

Universal fuel unit for oil burners

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

BLAST-IT-ALL BUMPER BLASTER

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements, Parts and Pricing

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

3.5 Cryosurface & Cryogenic Feed-through Specification

VAC-U-DRY VACUUM DEHYDRATION SKIDS

TM Series. Induced Draft, Counter Flow Optional Accessories

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

High Output Vacuum/Pressure Pump

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Glass Door Merchandiser. Model RM-49

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Type UB-2502A and UB-3002A Forced-Air Heater

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

KPS-E, KLS-E AND KLT-E SERIES

PDF Created with deskpdf PDF Writer - Trial ::

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

REFRIGERATED AIR DRYERS

Lubricated Rotary Screw Air Compressors

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

IMPORTANT CONSIDERATIONS

Modular Multi-position Air Handler

CO2 TRANSCRITICAL BOOSTER SYSTEMS

Direct Gas-Fired Make-Up Air

CR A-F-A-E-HQQE 3x400/ HZ

Dry Bulk Truck Blowers

C44A/C44AW DISHWASHER

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

THE CLEAR CHOICE FOR CLEANING

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts

Air-Cooled Condensing Units with Compact Screw Compressors

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

SECTION 50 - CAB CLIMATE CONTROL

STARJET BURNER SJ075 SJ980

Our Purifier systems

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Transcription:

INSTALLATION AND SERVICE INSTRUCTIONS Tuthill atlantic fluidics OSR-5, 10,15 & 20 Oil sealed liquid ring vacuum pump Vacuum & Blowers 4840 West Kearney Street Springfield, MO 65803 417-865-8715 (phone) 471-865-2950 (fax)

TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 3 2. INSTALLATION... 3 2.1 ELECTRICAL... 3 2.2 PRIMING THE SYSTEM... 3 2.3 PIPING... 3 3. NORMAL OPERATION... 4 4. START UP... 4 5. PREVENTATIVE MAINTENANCE... 5 5.1 Coalescing filter... 5 5.2 Oil... 5-2 -

1. GENERAL DESCRIPTION The OSR-5, 10, 15 & 20 oil sealed vacuum pumps are designed to operate over the full vacuum range from 0-29 Hg. Because of the unique axial flow design the pump operates at constant horsepower throughout the full vacuum range. The oil sealed vacuum pump consists of an A5, A10, A15 or A20 atlantic fluidics liquid ring vacuum pump close coupled to a 1, 2 or 3 HP motor, an oil separator tank with level gauge and seal flow control valve. The oil is cooled by an air-cooled heat exchanger with copper tubes and aluminum fins. An electrical controller is optional. 2. INSTALLATION 2.1 ELECTRICAL Provide 230 or 460 Vac, 3Ø, 60Hz power to the top of the contactor in the controller. Jog motor to check rotation. When looking at front of pump, rotation is counterclockwise. Some models are single-phase 1/60/115-230 volt. 2.2 PRIMING THE SYSTEM Oil has been provided (shipped separately for on-site filling). When charging the system for the first time, remove the plug and add oil until the level reaches ½ to ¾ of the oil gauge. The system is ready to operate. Some iron models could come from the factory with a rust inhibitor in them. Drain off prior to adding oil. 2.3 PIPING Inlet connection is the 1 NPT shut-off valve. The air discharge is 1 NPT on top of the oil separator tank. - 3 -

3. NORMAL OPERATION Connection to the process is made at the shut-off valve. When energized, the liquid ring vacuum pump creates a vacuum by recirculation of the oil in the reservoir tank. The oil temperature is maintained by diverting the flow to an air-cooled heat exchanger. The system is designed to operate continuously with little maintenance. (See Preventative Maintenance). 4. START UP Supplemental start up instructions for the atlantic fluidics liquid ring vacuum pump are outlined in detail in the appended Installation and Service Manual. Start the atlantic fluidics pump. The pump will immediately turn; it will clear the oil already in the pump head and begin to draw fresh oil from the tank. On start-up when the oil is below the operating temperature, the viscosity will cause the motor to overload. This is normal. Within five (5) minutes, the oil will be warm enough to lower the load on the motor. No other adjustments are necessary for normal operation. - 4 -

5. PREVENTATIVE MAINTENANCE 5.1 Coalescing filter The oil separator tank includes a filter, which is designed to coalesce the remaining oil in the vapor stream prior to exiting. If this filter becomes loaded with particles and other material, it will restrict the flow of air, and the increased backpressure will increase the load on the motor. The filter element should be replaced. Replacement filter element: 058285 0000 5.2 Oil The oil used as the sealant should be clear and free from contaminants, including particles and other debris, which could affect the pump s performance. Although the frequency oil changes will depend on the application, regular monitoring the color and clarity of the oil in the sight gauge will give the user a baseline to work from. Although the oil separator tank is designed with maximum efficiency for reclaiming the oil, some emissions are to be expected. This will require the user to top up the level in the oil tank on a periodic basis. The frequency will depend on many factors, including the number of hours of operation, the vacuum level, the oil temperature and the type of oil used. Standard Oil: Low Temp Oil: LR Oil 5 Gallon jug P/N 203040 0000 LT LR Oil 1 Gallon jug P/N 203096 0000 Note: The low temp oil should be used where starting in ambient conditions of 50 F or less. Consult factory for details. AF Pump: Refer the AF liquid ring vacuum pump manual for details on the vacuum pump itself. - 5 -