Operating Instructions. Rotating Vacuum Filter Type VRF

Similar documents
RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

INSTRUCTION MANUAL W-400

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

HX-30/40 and HX-30/40 S Glass and Dishwashers

VULKAN. Stationary Powder-Filling Machines

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

SuperKlean Washdown Products

BioMaster 250/350/600 BioMaster Thermo 250/350/600

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

ASPIRE Laboratory Aspirator

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Glass and Dishwashers AMX / AUX Series

Tornado Operations & Maintenance Manual

Glass and Dishwashers AMX / AUX Series

BarAid 400. Installation and. Starting from Serial No.:

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

BLAST-IT-ALL BUMPER BLASTER

Scrubber User Manual

Propane Heater REMKO PGM 30 REMKO PGM 60

Model: 1100 Float-Controlled Condensate Trap, PN 25

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Operating Manual BDC 1216

HD 525 S 06/03 A ! 5.960

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

SuperKlean Washdown Products

Shredder FD 8906CC Cross-Cut

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Fig. 2. Fig. 1. Fig. 3. Fig. 4. Fig. 5. Fig. 7 Fig. 6. Fig. 9. Fig. 8. Fig. 10 MAX H2O

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Less downtime. Better product quality. No odour. No more sticky tools. Reduced allergic reactions. Reduced tool wear

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Ventilation and air conditioning QUALITY FOR LIFE. Refrigerating systems and heat pumps. Operating manual

Operation Manual. Trash Water Pump ARTICLE Image similar

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

Oil burners fuel unit with solenoid valve

Wogaard Coolant Saver TM

Tornado Operations & Maintenance Manual

Rif Cod i220-0

Operating instructions

Operating Instructions. Keep for future reference! Maschinenbau Werkzeuge Laborgeräte. Machine no.:... Hausanschrift:

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

IMAGE V. Parts and Service Manual

INSTRUCTION MANUAL Model: SU3022

Rack conveyor dishwashing machine STR. Operating instructions

Easy Rooter. Operating Instructions

Operating Manual. the semi automatic

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Parts Available from

Requests for Daily Care and Maintenance

PJ130S High Pressure Cleaner

Contents. Safety instructions. Device elements. Colour coding. Hazard levels

General Maintenance and Operating Instructions for Heat Exchangers

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Conveyor Washer Operation Manual

Model K 240 plus Part No

K 3.97 M. Specifications or visit our website: In USA call: Part No

Owner s Manual. Van Ho Pug Mill Power Plus 160 Series

NSS STANDARD-SPEED FLOOR MACHINES

Oil burners fuel unit with solenoid valve

Model K 330 M Part No

Operating Instructions

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

OWNERS GUIDE TO INSTALLATION AND OPERATION

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

REMKO CLK Mobile automatic heater

PRO 2000i LOW LEVEL DEPOSITOR

Operating and installation instructions

Speedrooter 91. Operating Instructions

Model K 520 M Part No

Owner s Manual. Van Ho Pug mill Power Plus 200 Series

Owner s Manual. Van Ho 1HP Pug Mill Power Plus 130 Series

APW PSI PRESSURE WASHER

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Universal fuel unit for oil burners

SOLUS-500 EXTRACTOR 120V

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

Speedrooter 91 Operating Instructions

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Tornado Operations & Maintenance Manual

SOLUS-310 EXTRACTOR 120V

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Operating instructions

Transcription:

Operating Instructions Rotating Vacuum Filter Type VRF GB

Rotating Vacuum Filter Type VRF Table of Contents 1 Description of machine and functions... 5 2 Danger and safety instructions... 6 2.1 General instructions... 6 2.2 Instructions for repair and maintenance work and malfunctions... 7 3 Installation and location... 8 4 Start-up and operation... 8 4.1 Prior to initial operation... 8 4.2 Filling the equipment... 9 4.3 Setting various modes of operation... 10 5 Maintenance... 11 5.1 Removal/installation of the sieve drum... 11 5.2 Adjusting the flow volume... 12 5.3 Cleaning the sieve drum... 13 5.3.1 Cleaning by suction... 13 5.4 Important directions for the vacuum drum... 14 6 Information on coolants/tanks... 14 7 Maintenance table... 15 8 Eliminating malfunctions... 17 9 VRF basic settings... 19 10 Accessories... 21 10.1 Setting instructions for scrapers... 21 3

Rotating Vacuum Filter Type VRF 1 Description of product and functions Scope Cleaning of cooling lubricants Field of application - Primarily used in conjunction with machine tools for both single machines and machine groups. Function - Liquid flows through the inflow chamber into the rotating vacuum filter from a lifting pump. A sieve drum is arranged such that it is completely immersed and forms a vacuum chamber. - A vacuum pump sucks the liquid from the inside of the drum and conveys it to the clean water tank. The resulting vacuum causes liquid to flow into the drum; dirt particles are retained by the sieve drum mesh. - Vacuum pressure increases due to dirt particles (filter cake) deposited on the fine filter mesh. - A preset vacuum pressure value activates drum rotation by means of drive motor and chain. - The sludge cake is scraped off and the filter is rinsed by reversed flow. - Simultaneously, the sludge is discharged into a sludge container by means of a scraper chain. - The liquid in the clean water tank is conveyed to the processing machine by means of the pure water pump. - Multiple cleaning (circulation) by internal flow-off of the liquid (10-20 litre/min. approx.) from the clean water tank (deep tank) to the dirty water tank. Noise level: < 70 db(a) 5

Vakuum-Rotatiosfilter Typ VRF 2 Danger and safety instructions 2.1 General instructions - Always observe all statements and instructions in the operating instructions delivered with the equipment! - It is forbidden for unqualified persons to work at the plant! - Ensure correct fastening if components were installed by customers! - Never bypass safety contrivances (e.g. safety clutch)! - The operation of safety contrivances must always be guaranteed! - Work on the electrical equipment may be carried out by qualified personnel only. - Observe the relevant VDE requirements and connection requirements of the responsible Electricity Board! - Do not remove covers while the equipment is in operation. 6

Rotating Vacuum Filter Type VRF 2.2 Instructions for repair and maintenance work and malfunctions I 0 - Switch off the main switch! - Secure the equipment against accidental start-up! - Ensure that the equipment is dead! - Depressurize the plant! - Close pipe valves! - Remove all noxious materials! - Coolants must not enter the environment! - When handling chips, wear protective clothing, safety boots and protective gloves! 7

Vakuum-Rotatiosfilter Typ VRF 3 Installation and location - Ensure secure positioning and installation! - Secure equipment against accidental start-up! - Install equipment on a level surface. - Connect supply/return lines and reverse flow rinsing pump, if applicable. Check retrofitted piping for leaks. - Install sludge container etc. - Connect power supply for motor(s) and pump(s) 4 Start-up and operation 4.1 Prior to initial operation - Connect electrical equipment (ensure proper voltage, frequency, current strength and sense of rotation). - The rotating vacuum filter must always be connected via a lifting system (dirty water tank) because there may be an overflow of liquid during operation. - The rotating vacuum filter may be filled directly from above or by means of a lifting pump. In both cases the equipment is filled up until the liquid flows back to the dirty water tank through the lateral overflow pipe. The dirty water tank should be dimensioned to be able to hold the liquid coming from the rotating vacuum filter without flooding! - The vacuum pump must be deaerated before initial operation; this applies also when the pump has aspirated air. For this purpose, open the air bleed screw at the pump (below the delivery-side flange) until water is forced through the opening. To this end, the equipment must be filled sufficiently. - The entire equipement must be free of loose hardware (such as tools, accessories, etc.). 8

Rotating Vacuum Filter Type VRF 4.2 Filling the equipment The coolant tank consists of: Rotating vacuum filter, clean water tank, dirty water tank - Fill the rotating vacuum filter and the clean water tank. - Remove the cover plates from the rotating vacuum filter and the clean water tank. - Fill the equipment with clean liquid, until the float switch in the rotating vacuum filter or the dirty water tank closes at the maximum level. By means of an installed overflow pipe, the dirty water tank will be filled automatically. - Switch on the equipment for a short time, until the lifting pump starts to convey. - Switch off the equipment und refill the cooling lubricant if necessary. - Mount the cover plates again. 9

Vakuum-Rotatiosfilter Typ VRF 4.3 Setting various modes of operation Only for RVF with switch box and control elements by Knoll: "Manual" mode - Switch main switch to "ON" - Set selector switch to "Manual" Now each consumer may be switched on inidvidually. "Automatic" mode - Switch main switch to "ON" - Set all consumer switches to "Automatic" - Set selector switch to "Automatic mode on" Now the equipment is set for automatic operation RVF, controlled by the processing machine : see operating instructions of the processing machine RVF with MT control: see operating instructions RVF-MT 10

Rotating Vacuum Filter Type VRF 5 Maintenance 5.1 Removal/installation of the sieve drum 1 The sieve drum is installed accordingly in the reverse sequence. - Switch equipment off and secure against accidental start-up (switch main switch off). Remove upper tank lids. - Drain liquid from equipment - Risk of injury! - Do not reach into the equipment when parts are moving or when the main switch is switched on. - Unscrew and remove the driver blades mounted at the drum circumference (index the drum in the manual mode until all driver blades have been removed - do not forget to set the main switch to "off" position). - Switch equipment to manual operation; switch scraper belt drive on, until the chain joints of the bush chain are visible and accessible at the top (1). - Switch equipment off and secure against accidental start-up (switch main switch off) - Fold stripper bar away from drum. - Open chain joints and remove scraper belt chain from the sieve drum (the chain does not have to be removed from the tank) - Loosen the locking screw (5) on the bearing - Remove the hexagon nuts (2) and pull the bearing lid (3) straight from the sieve drum. Symbolic figure Check bearing lid seal for damage, replace if required. - Unscrew and remove the sieve drum lid (4). Symbolic figure 11

Vakuum-Rotatiosfilter Typ VRF - Dismantle the rinsing pipe in the drum at the screwed connection and remove the pipe. - Check the holes of the rinsing pipe for soiling and clean them if required. - Remove the complete drum assembly from the housing without damaging the filter fabric.. - Clean and check seals and bearings inside the sieve drum, replace if damaged. 5.2 Adjusting the flow volume Set flow only at the maximum liquid requirement of the processing machine(s) Symbolic figure 1 2 3 Supply flow (dirty water flow) - The amount of dirty water must not be higher than the amount of clean water (there must be no overflow in the dirty water tank or lifting tank (2) respectively). - Increase the clean water flow at the adjusting sleeve (1) or reduce the dirty water flow (3) as required. Flow rate (clean water flow) - The adjusting sleeve / the gate valve for adjusting the flow rate is located in the pipe of the vacuum pump at which the pressure is applied (1). - The flow rate is set correctly, if the filling level in the RVF slowly recedes. A Adjusting sleeve (installed only up to size RVF 500 ) - Unscrew screw plug (A) and seal. - Loosen the locking screw (B). To decrease flow: Turn adjusting nipple (C) in clockwise direction. Do not unscrew the adjusting nipple completely -iquid will be forced out under pressure. B C - Tighten locking screw and screw in screw plug; replace seal if required. 12

Rotating Vacuum Filter Type VRF 5.3 Cleaning the sieve drum 5.3.1Cleaning by suction The level of liquid in the rotating vacuum filter must be lowered until the surface of the sieve drum may be cleaned with a suitable vacuum cleaning device. - Switch off entire equipment - Remove covers - Drain the rotating vacuum filter by switching the vacuum pump on until the sieve drum rises above the liquid and may be cleaned. Use an extractor with a protective cap in order not to damage the filter material. Under no circumstances may a wire brush or sharp and pointed objects be used. - During the cleaning process the equipment must remain switched off and secured against accidental start-up! Symbolic figure Protective cap 13

Vakuum-Rotatiosfilter Typ VRF 5.4 Important directions for the vacuum drum After the initial operation the vacuum drum must be continuously immersed in liquid - if this cannot be guaranteed, clean the filter material (e.g. by means of sucking off) and preserve with anticorrosive agent. Do not let the vacuum drum dry if contaminated! Dried dirt might "clot" the sieve meshes of the filter material or cause corrosion. The vacuum drum becomes impermeable and thus useless. In most cases, later attempts at cleaning tend to be futile. 6 Information on coolants / tanks - Circulate the coolant permanently (circulation on weekends is recommended) - Prevent organic substances from entering - Avoid external oil input - For an emulsion, the temperature should not exceed 25 C - The ph-value should be within the neutral range - The degree of hardness of the water for the preparation should not exceed 15 dh - The degree of hardness due to upgrading must not exceed 20 dh Cleaning of the coolant tanks - The cleaning intervals depend above all on the type of processing, material, type of coolant, and the number of working hours; for this reason, no generally valid interval may be stated. As a guidline, a cleaning interval of 4 through 8 weeks is recommended. 14

Assembly/ Interval Maintenance work Safety instructions/ component note Sludge container Pumps Electrical equipment - Motor(s) - Wiring - Filling level switch 1 day --- --- 3 months 3 months Drain accumulated liquid See manufacturer's operating instructions See manufacturer's operating instructions Check for breakage and damage Check function Replace defective wiring Cross both switching positions in manual operation 7 Maintenance table - Safety equipement 3 months Check function Tanks and piping 6 months Check for leakage, corrosion, and damage Hazardous materials must not escape under any circumstances Scraper strips 6 months Check plastic insert for wear Replace worn inserts 15 Sieve drum 1 month 1 year --- Check for wear and damages, clean Change sieve drum if necessary Clean tissue (clean tissue with vacuum cleaner or from the inside using a high pressure cleaner) Disassemble drum in case of wear or damages (see chapter 5) and return it to the manufacturer for replacement Cleaning interval depends on type of swarf/chips and coolant (see chapter 5.3) Outside influences may damage the filter material Rotating Vacuum Filter Type VRF

16 Assembly/ Interval Maintenance work Safety instructions/ component note Piping 1 year Disassemble, clean, and check (for wear) the return /shut-off traps and valves Clean sludge filter of the hose assembly and strainer basket Switch equipment off Relieve piping from pressure Cooling lubricant off Lower piping Operate shut-off valve if necessary Replace defective parts Coolant tanks/ float switch 500 working hours Check for contamination (sludge deposits) and clean if required Depending on the tooling method, the interval may be significantly shortened Coolant tanks are extras and thus not installed in every equipment. Manometer --- Open the stop valve only for the measuring procedure Useful life of the manometer is increased Vakuum-Rotatiosfilter Typ VRF

Disturbance Possible causes Remedy No or insufficient reverse flow rinsing Safety clutch slips (loud rattling noise) Power transmission between clutch hub and running wheel interrupted Vaccum contact-making pressure gauge / pressure sensor defective Filling level in the clean water tank too low Holes in the rinsing nozzle of the sieve drum obstructed Filling level in the slush pump tank too low Coarse parts block the equipment Safety clutch defective Amount of chips/swarf too high Replace gauge/ sensor Refill liquid Open and clean sieve drum (refer also to chapter 5.1) Manual reverse flow rinsing max. 20 sec. Refill liquid Remove parts Replace clutch Clean equipment, reduce discharge cycle time 8 Eliminating malfunctions 17 Spur wheel Hub Rotating Vacuum Filter Type VRF

18 Disturbance Possible causes Remedy No chip/swarf discharge Amount of chips/swarf too high Reduce discharge cycle time Insufficient cleaning performance or very short reverse flow rinsing cycle (< 2min) Filter tissue clogged or clotted Clean tissue surface with vacuum cleaning device or from the inside using a high pressure cleaner The normal reverse flow rinsing cycle ranges from 2-5 minutes. Reverse flow rinsing cycles < 2 minutes may cause damages at the slush pump Vakuum-Rotatiosfilter Typ VRF

Rotating Vacuum Filter Type VRF 9 RVF basic settings In the hose assembly from the lifting pump to the RVF, there is an adjusting sleeve (2). By means of this sleeve, the amount of dirty water which is admitted to the RVF may be adjusted. RVF with level switch For the operation of the equipment, no overflow pipe for the liquid from the RVF to the dirty water tank is required. Setting: Close the adjustement sleeve, until the liquid level for the normal operation of the equipment levels out immediately below the lateral overflow pipe (1), or slowly starts to recede. Overflowing during the reverse flow rinsing procedure is quite normal. In case the efficiency of the vacuum drum deterioriates due to solings, the amount of overflow increases and thus dirt will be discharged. In this case, the vacuum drum has to be rinsed by reverse flow several times, or to be disassembled and cleaned. Symbolic figure - 2 + 1 19

Vakuum-Rotatiosfilter Typ VRF Cycle times and settings Procedure for equipment START: 1. Lifting pump ON 2. Vacuum pump ON 3. Machine supply pump(s) ON now the RVF cycle times start: the cycle times may or must be changed individually - RVF de-sludger: dead time 30 sec., pulse time 6 sec - Vacuum: - 0,15 bar - when the contact gauge responds (at - 0,15 bar): vacuum pump OFF, de-sludger ON, slush pump ON (6 sec. approx.) For some types of processing (e.g. aluminium), it may be necessary to employ an interval reverse flow. Interval reverse flow (induced reverse flow) In order to guarantee an effective reverse flow and a constant cleaning performance, the reverse flow process should be activated every 10 minutes for 6 seconds approx. In case the contact gauge responds less often, the interval reverse flow is necessary. Responding of the float switch in the RVF for MIN: vacuum pump off The swarf conveyor should run in continuous operation, in case of a high water discharge, short standstill intervals are, however, possible. Nevertheless, the standstill intervals must not be so long that the chpis/swarf starts to accumulate, and consequently, the conveyor will be blocked. 20

Rotating Vacuum Filter Type VRF 10 Accessories 10.1 Setting instructions for scrapers Risk of injuries! For all work carried out at the rotating vacuum filter: - Do not stand or reach into the rotating vacuum filter while being in operation! - Switch main switch off - Secure rotating vacuum filter against accidental start-up! - Switch equipment on, until the conveying strip is located 20 mm before the scraper - Switch equipment off and secure against accidental start-up - Dismantle sheet metal sheating at the sludge ejector - Set scarper at the adjusting screw, loosen lock nut beforehand - Set scraper at a distance of 10 mm from the edge of the strip! - Mount sheet metal sheathing at the sludge ejector again - Incorrect settings will cause damages to the scraper and to the equipment! - The equipment may be blocked! Correct Pull strip down ward Wrong 10 mm 21

27029/Vrf-bed-englisch.pm6/09.98Mo/V1.0 Coolant cleaning systems KNOLL Maschinenbau GmbH Phone 07581/2008-0 Swarf conveying systems Schwarzachstr. 20, Postf. 1362 Telefax 07581/2008-140 Low lift and jetting pumps D-88342 Bad Saulgau E-mail info@knoll-mb.de web www.knoll-mb.de