IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

Similar documents
WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Experimental Study of Waste Heat Recovery through Refrigeration System

Enhancement of COP in Vapour Compression Refrigeration System

EXPERIMENTAL INVESTIGATION ON RECOVERY OF WASTE HEAT FROM WINDOW AIR CONDITIONER

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Numerical Simulation of Window Air Conditioner

Numerical Investigation of Household Refrigerator by Recovering Heat from the Condenser

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Review on study of waste heat utilization techniques in vapour compression refrigeration system

Waghmare Tushar Ramrao, D.S.Nakate

Fabrication of Hot and Cold Water Dispenser

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Performance Assessment of Water Cooled Condenser Refrigeration System

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Performance investigation of Air-conditioning system using ejector as expansion device

Experimental Analysis of Waste Heat Recovery System for Combined Refrigerator and Air Conditioning Unit

Design, Manufacturing of Chilled Water System for Process Cooling Application

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Experimental Investigations of Heat Pump for Domestic and Light Commercial Market.

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Design of LPG Refrigeration System

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering


Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Design & Fabrication of Hybrid Cooler

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

II. OBJECTIVE OF RESEARCH

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

A Review of Different Types of Combine Cooling System

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Global Journal of Engineering Science and Research Management

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

DEEPAK PALIWAL, S.P.S.RAJPUT

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Design and analysis of household direct cool refrigerator with vertical evaporator

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Performance Study of Triple Concentric Pipe Heat Exchanger

An experimental study of the effect of evaporator temperature on the compressor work of a simple vapour compression refrigeration system

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Heat utilization from refrigerator condenser using water heater and hot box

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Optimization of the Evaporative Condenser Design

Reheating Refrigeration System

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Department of MCE, Islamic University of Technology 2. Abstract

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Design and Performance Analysis of a Car Air Conditioner with LPG as a Refrigerant

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Fabrication and analysis of instantaneous water cooler by using isobutane as refrigerant

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

REFRIGERATION TUTOR. OBJECTIVE: To perform test on the refrigeration tutor to determine different COPs and other performance parameters.

Modified Air Cooler with Split Cooling Unit

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Transcription:

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online): 2321-0613 Design of Compact Condenser for Waste Heat Recovery and Cop Enhancement of Refrigerator Vinayak Nathjogi 1 Shruti Suryawanshi 2 Abhijit Khude 3 Dilbar Sayyad 4 Prof S.B.Teli 5 1,2,3,4,5 Department of Mechanical Engineering 1,2,3,4,5 Smt. Kashibai Navale College of Engineering, Vadgaon, Pune Abstract Refrigerator has become an essential commodity rather than luxury item. The heat absorbed from space to be refrigerated (Evaporator) and the heat from the compressor is added to refrigerant is rejected to the surrounding through a condenser. This heat can be recovered and used for the various purposes. Paper represents research work on a design of compact condenser (shell and tube type) for effective heat recovery in minimum possible time and cop enhancement of the domestic refrigerator. The modified condenser can mounted in the vacant space just above the compressor. Therefore vacant space is utilized and handling problems due to bare copper tube is also reduced. Natural circulation of water eliminates use of pump. Cad modeling and matlab programming are performed for ease in manufacturing and to determine the dimensions of the proposed condenser. By the experimental investigation it is found that this modification in existing system increases the performance of system to 28.61%. It is observed that temperature of cold water rises to 500c just within 20 minutes. This hot water can be used for various purposes like dish washing, bath, laundry etc. Therefore the proposed system makes the household refrigerator to be work as both refrigerator and water heater. Key words: Compact Condenser, Waste Heat Recovery There are some problems with air cooled refrigerator. Refrigerator needs to be place away from the wall for proper ventilation. There is handling problem also for shifting of refrigerator due to bare copper tubes of condenser. These problems can also be solved by using this system. We can used various refrigerants but generally R- 134a is most preferable substitute for R-12 and has 74% less GWP than R-12. Now a day s refrigerator is used in almost all middle class families, general stores for food preservation. In such refrigerator the refrigerant which is working medium, absorbs the heat from refrigerated space as well as the heat is added to it during compression. This total heat is then rejected to the atmosphere, through condenser. Therefore there is much scope for recovery of this waste heat. The main objectives of research work are is to extract the heat from the domestic refrigerator by designing a compact condenser. Recover the heat in minimum possible time. And Increase the COP and overall efficiency of the system. Power consumption or LPG consumption can be eliminated for water heating. Hot water can be used for geysers, laundry, and dish washing like applications. I. INTRODUCTION Energy saving is one of the key issue not only from the view of energy conservation but also for environment. Energy conservation is now faced with the challenged of applying the latest technology for facilities and improvement that can be justified on its own merit. Energy conservation is the technique to be adopted to face energy crisis under these circumstances. Waste heat before rejecting to the environment, we utilize a part of this energy in heating applications. Various waste heat sources are available such as domestic and urban waste which includes heat losses in cooking appliances, heat losses in air conditioners, heat losses in HVAC systems etc. Waste heat recovery system can be used in various applications but in present study, we shall focus on the use of waste heat recovery in air cooled domestic refrigerator. Fig. 1: Block Diagram of WHRS II. LITERATURE REVIEW A number of experimental studies have been done to recover the lost heat in domestic refrigerator systems. Many of these studies have been done by using different refrigerators modifications such as water-cooled condensers, different refrigerants, waste heat recovery systems etc. G.G Mominand Y.A.Patil [3] has found that performance of the system can be increased by using thermosyphon technique for water circulation. It also eliminates the need of pump for circulation of water. Y.A.Patil and H.M. Dange[1] discussed on waste heat recovery from an refrigerator by using a typical waste heat recovery unit. S.C.Walavade [5] has shown the effective and simple way of heat recovery by dividing the condenser and mounting it in metal cabin. P.Elumalai [7] has done a case study on waste heat recovery by using hot oven and heater chamber at compressor outlet. Tarangagarwal[8] has given the cost effective method of cop enhancement by mounting the condenser coil in iron galvanized box. In this paper the efforts are made to replace the box with compact WHRU and improving the heat transfer rate between refrigerant and water. III. SYSTEM DESCRIPTION The cold water from the water tank sent to the condenser thorough the mass flow meter. The amount of water going to the condenser can be adjusted with the help of mass flow meter. Water absorbs the heat which is rejected by the refrigerant in the condenser and leaves it as hot water. The manually operated control valve is assembled to the exit line All rights reserved by www.ijsrd.com 65

of hot water. So by closing this valve the time for which the water remains in the condenser can be adjusted and desired hot water temperature can be obtained. The working of system is same as vapor compression refrigeration cycle. Design of Compact Condenser for Waste Heat Recovery and Cop Enhancement of Refrigerator Fig. 2: Block diagram for setup The dimensions of condenser are determined by mathematical modeling. It is found that the shell diameter and length is 6 cm and 40 cm respectively. The length of condenser is slightly less than width of refrigerator. So we can imagine the compactness of condenser. A. System Specification Refrigerant R-134a Cooling capacity 365 Btu/hr Power input Rated 100 watts Refrigerant Control Capillary Compressor Cooling Static Evaporator temperature range -34 to -12 Displacement/revolution 4.00 cc No of cylinders One Evaporating temperature -10 Condensing temperature 40 Liquid sub cooling temperature 32 Return gas temperature 32 suction temperature 32 Suction (Evaporator) pressure 0.27579 Bar Discharge (Compressor)pressure 13.7895 Table 1: System Specification B. Mathematical Modeling 1) Coefficient of Performance (COP) From steam table at pressure 0.27579 bar h 1=366.94KJ/kg s 1=s2=1.7826 KJ/kgK From steam table at pressure 13.7895 bar S 2 =1.7065 KJ/kgK h 2 =424.08 KJ/kg From steam table at pressure 13.7895 bar h 4=hf 3=274.45 KJ/kg S 2= S 2 + 2.3Cp log (T 2 / T 2 ) T 2= 67.61 h 2 = h 2 + Cp (T 2-T 2 ) h 2 = 448.929 KJ/kg h1 h4 COP = h2 h1 COP = 1.128 Fig. 3: Modeling 2) Total heat rejected by the condenser (Q) Refrigerating Effect = h1 h f3 = 92.49 KJ/kg a) For compressor Motor power = 1/8 HP =92watt 100watt COP = Q W Q1 = 112.8 watt Q 2 = Q 1 + W = 212.8 watt Mass flow rate of refrigerant m r= Q2 = 0.002301 kg/s RE Heat available at condenser for Rejection Q = m r * (h 2-h 3) = 401.47 watt 3) Mass flow rate of water required (m w) a) For mass flow rate of water Q = m w * Cp w * T For to achieve desired temperature of hot water we can calculate the mass flow rate required of inlet water For T = 20 o C m w = 0.004794 kg/s 4) Logarithmic mean temperature difference (LMTD) T c1 = 25 o C T h1 = 67.61 o C T c2 = 45 o C T h2= 37 o C a) For counter flow heat exchanger T 1 = T h1 Tc 2 = 22.61 o C T 2 = T h2 Tc 1 = 12 o C LMTD = T1 T2 ln ( T1 = 16.7486 T2 ) 5) Overall heat transfer coefficient (U) a) For h iand h o calculation T mean = Twin+TRout = 31 o C 2 Properties of water at 31 o C b) For water side hf g= 2431 KJ/kK f =0.165µ = 0.798 * 10-3 kg/md = 0.053m = 53mm Heat transfer coefficient for water side (h i) h i= 0.725 [ ρ2 g hfg Kf 3 ] µ D (To Ti) Heat transfer coefficient for water side (h i) = 475.98 c) For refrigerant side hf g= 179.1 µ=1.83*10-4 K f= 0.00342 Similarly heat transfer coefficient for refrigerant side (h r) = 225.38 Fouling factor for Refrigerant (f r) =0.00017 Fouling factor for water (f w) =0.00017 1 = 1 + 1 + µ + fr+ fw U hi hr K U= 145.38 w/m 2 k 6) Total Area required for heat recovery (A) Q = U * A * LMTD A = 0.16488 m 2 R= [ Tc1 Tc2 ] S= [th2 th1 ] th2 th1 Tc1 th1 R= 0.4533 S= 0.7183 All rights reserved by www.ijsrd.com 66

Design of Compact Condenser for Waste Heat Recovery and Cop Enhancement of Refrigerator Fig. 3: correction factor: one shell pass; two or more even tube 'passes From graph f t = Temp correction factor = 0.85 New LMTD = 16.7486 * 0.8 = 14.23631 o C Q New Area = = 0.1939 m2 U newlmtd 7) Length of copper tube required (L) Area = π Do L Nt = 10.286 m 2 8) Total no of copper tubes required (N t) L No of turns Nt = = 21.42 22 Fixeddistance L isassumed Tubes 9) Tube pitch (P t) Pt = 1.25 * do=0.75 mm 10) Bundle diameter (Db) Db = do * ( Nt K1 )1/n1 For 1 pass: Triangular Pitch K 1= 0.319 n 1= 2.412 Db= 4.33 cm 11) Bundle diameter clearance (BDC) Bundle diameter clearance (BDC) = 10 mm 12) Shell diameter (Ds) Shell diameter (Ds) = Db + BDC= 5.33 cm 13) Baffle spacing (Bs) Baffle spacing (Bs) = 1.8 * Ds= 9.6 cm Fig. 4: CAD modeling of shell and tube condenser CAD model is designed as per the dimensions obtained from mathematical modeling. CREO software is used for the designing. C. Observation Table Time in Minutes Compressor Outlet Water Outlet Evaporator 0 40.1 33.2 12 5 43.3 39.5 11 10 46.2 43 9.5 15 48.6 46.9 4.1 20 49.8 47.9 2.2 25 50.4 48.3 0.8 30 51.8 48.2-0.1 35 52.3 47.9-0.3 40 52.8 48-0.1 45 52.9 47.4-0.5 50 56.1 48.2-0.9 55 58.3 48.5-1.2 60 58.3 48.7-1.4 65 60 49.3-1.4 70 59.9 49.7-1.3 75 61 49.9-1.4 80 60 49.6-1.6 Table 2: Observation Table From the observations we can see that the temperature of water increase to 48 0 c within 20 minutes only. Maximum temperature of water which can be achieved is 50 0 c. IV. RESULTS AND CALCULATIONS A. Cop Calculations Time required for 10 impulse = 60 sec Trial duration = 10 minutes Energy meter constant=3200 imp/kw hr = 1000*(3600/3200) = 1125 watt Work supplied to compressor = 1125 10 watt 60 =0.1875kw For 25 liters load on system Cop of old system: Refrigerating effect produced = ( mass of water cp temperature rise for 10 minutes ) trial duration in seconds =25*4.187*1.25)/(60*10) = 0.2180 kw Cop = refrigerating effect work supplied Similarly cop of new system Time for 10 impulse = 84 sec New cop =1.6277 = 1.162 % improvement in cop = ( new cop old cop ) 100 new cop = 28.61 % Fig. 5: Actual model of shell and tube condenser Fig. 6: Graph Time vs rise graph All rights reserved by www.ijsrd.com 67

Design of Compact Condenser for Waste Heat Recovery and Cop Enhancement of Refrigerator System takes only 20 minutes to raise the temperature of water to 48 0 c. Maximum temperature which can be obtained is 50 0 c.as per earlier researches; system takes 2 hours of time to raise the temperature to 50 0 c. Fig. 7: Graph 2 Load vs Actual COP graph Actual COP of the system with compact condenser is more than system with existing air cooled condenser system. COP has improved to 28.61 %. Fig. 5: CAD modeling of setup The green color represents the condenser. The condenser is mounted just above the compressor. The surface area required for this condenser is much lesser than air cooled condenser. So it saves lot of space which is wasted for mounting air cooled condenser. B. Actual Experimental Setup Fig. 5: Actual Experimental Setup V. CONCLUSION The maximum temperature achieved in the water Storage tank at 25 liter load is 50 C within 20 minutes. Power Consumption is reduced by using water cooled (HRU) condenser instead of air cooled. Cop of system increased to 28.61 % The designed condenser is much compact and can be adjusted easily in the vacant space available above compressor. It reduces the handling problems of refrigerator and reduces chances of leakage of refrigerant from bare copper tube. Recovery of heat from the condenser reduces the heat load to surrounding and it makes surrounding comfortable. REFERENCES [1] Y.A.Patil, H.MDange, Improving the Performance of Household Refrigerator by Recovering Heat from the Condenser. International Journal of Science and Research (IJSR), India Online ISSN: 2319-7064 Volume 2 Issue 6 (2013) [2] Sreejith.K., Experimental Investigation of A Domestic Refrigerator Having Water-Cooled Condenser Using Various Compressor Oils. Research Inventy: International Journal Of Engineering And Science Issn: 2278-4721, Vol. 2, Issue 5 (February 2013), pp 27-31 (2013) [3] Momin, G.G., Deshmukh, S.R., Deshmukh, M.T., Chavan, P.T., Choudhari P.P., Cop Enhancement of Domestic Refrigerator by Recovering Heat from the Condenser. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 (2014) [4] Jay J. Bhavsar, V K. Matawala, S.B.Dixit, Performance Analysis of Spiral Tube Heat Exchange, International Journal of Engineering and Advanced Technology (IJEAT) ISSN: 2249 8958, Volume-2, Issue-4, (April 2013 ) [5] S. C. Walawade,B.R. Barve, P. R. Kulkarni, Design and Development of Waste Heat Recovery System for Domestic Refrigerator, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684, PP: 28-32 [6] Tanmay Patil, Nitesh Medhane, Yogesh Mahapure, Kalpesh Nagmoti, Prof. Anil Dube,A Review On Recovering Waste Heat From Condenser Of Domestic Refrigerator, International Journal of scientific research and management (IJSRM), Volume3, Issue3, Pages 2409-2414 (2015) [7] P. Elumalai, R. Vijayan, K.K. Ramasamy and M. Premkumar, Experimental Study on Energy Recovery from Condenser Unit of Small Capacity Domestic Refrigerator, Middle-East Journal of Scientific Research 23 (3): 417-420, 2015 ISSN 1990-9233 IDOSI Publications, (2015) [8] Tarang Agarwal, Manoj Kumar, Praveen Kumar Gautam, Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant, International Journal of Emerging All rights reserved by www.ijsrd.com 68

Technology and Advanced Engineering Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 4, Issue 11, November 2014) [9] Refrigeration and air conditioning by R.S.Khurmi and Gupta, fifth edition. Design of Compact Condenser for Waste Heat Recovery and Cop Enhancement of Refrigerator All rights reserved by www.ijsrd.com 69