Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Similar documents
INSTALLATION & TESTING MANUAL

INSTALLATION & TESTING MANUAL

Model TWBS.EW.H Tempered Water Blending System

Model Combination Shower Eye/Face Wash

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model 7656WCC Eye/face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model TWBS.SHE Tempered Water Blending System

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 9001, Alarm

Model 9001, Alarm

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 1011/1011HPS Drinking Fountain

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7500EB Portable Eyewash with Heater

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 1900 Retrofit Bottle Filler

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Model 7611 Eye/Face Wash

Model H1011.8/H1011.8HPS Water Cooler

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

3121FR Pedestal Mounted Drinking Fountain

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

H Barrier-Free Wall Mounted Electric Drinking Fountain

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

Model 1920/1920HPS/1920W Bottle Filler

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Installation Instructions / Warranty

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION, OPERATION AND MAINTENANCE

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

ADA Compliant Wall-Mount Fountain and Bottle Filler

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

Installation and Operation Guide

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

EMERGENCY DRENCH SHOWER

INSTALLATION ADJUSTMENT SERVICE

TA-300, TA-300-LF, TA-350, TA-350-LF

Installation Instructions PP-AS20 Anti-Scale System

OUTLET HOT INLET COLD INLET INSTALLATION

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Installation and Operation Guide

installation, operation & Maintenance manual Floor-mounted Induction units

Installation, Operation, and Maintenance Manual

PNLDII-28 Condensate Drain Instruction Manual

INSTRUCTION MANUAL HS-229G

TITAN FLOW CONTROL, INC.

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Point-of-Use Water Heater Owner s Manual. Installation, Care & Use

Comfort Series Instant Hot Water System

Installation Instructions / Warranty

OPERATING AND INSTALLATION MANUAL

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

OPERATING AND INSTALLATION MANUAL

Installation and Testing of Inverted Bucket Steam Traps Manual

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Installation Instructions / Warranty

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Installation Instructions / Warranty. Massaud

TORRID MARINE YACHT QUALITY Since Owner s Manual

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

Installation Instructions / Warranty

55-Gallon Dispenser Package

TABLE 1 Electrical Specifications

Installation & Operation Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9400 No. 2080243(7) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of two years from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 04/17 Model 9400 Page 1 of 5

RECOMMENDED TOOLS: Teflon tape pipe joint sealant, pipe dope if used sparingly, making sure none enters the heating system, adjustable pipe wrenches. WATER CONNECTIONS: The minimum recommended supply line is 1 1/4 IPS. The inlet connection is a 1 1/4 NPT union. Cold supply temperatures should range from 40º F to 80º F (4.4º C to 26.7º C). The supply must be capable of delivering 25 gpm (94.6 L/min) at a minimum of 55 psi (3.8 bar) dynamic pressure to the instantaneous heater. Outlet connection is a 1 1/4 NPT union. Where sediment or mineral content is a problem, an inline filter is recommended. STEAM CONNECTIONS: The unit requires 600 lb/hr (272 kg/hr) of steam @ 45 psi to 60 psi (3.1 bar to 4.1 bar). Usage in standby is 5-20 lb/hr (2.3-9.1 kg/hr) INTRODUCTION The HAWS 9400 is an on demand steam water heating system for use with emergency safety showers and eyewashes where hot water is not supplied. As long as cold water can be supplied (40º F (4.4º C) minimum), the 9400 can supply 80º F (26.7º C) water to safety showers and eyewashes. PERFORMANCE FEATURES OF THE 9400 SYSTEM The heart of the 9400 is a steam heat exchanger, a multi-stage feedback control valve strategy and a mixing valve that maintains the output water temperature at 80º F (26.7º C) regardless of inlet water temperature (between 40º F (4.4º C) and 80º F (26.7º C)). CAPACITY HAWS 9400 produces up to 25 gpm (94.6 L/min) of 80º F (26.7º C) water for one shower/eyewash combination. At that flow, there will be a pressure drop of approximately 25 psi (1.7 bar) across the unit. The warm water heater is designed to activate at a minimum flow of no less than 3 gpm (11.4 L/min). INSTALLATION The standard 9400 is sized to heat enough water for one shower/eyewash combo at a time. This water heating system should be installed in close proximity to the shower (3 to 12 of 1 1/4 IPS piping between the 9400 outlet and the shower inlet). It should be clearly identified, with easy access, and should remain free from obstructions. Supply lines must be heat-traced if subject to freezing temperatures. If any part of the piping network runs through a cold area, this piping should be heat-traced with self-regulating heat tape. Any heat-traced piping should be protected with scald protection bleed valves. Complicated chains of showers and eyewashes, long piping runs and recirculating loops should all be evaluated by a qualified engineer. IMPORTANT: The 9400 is designed for intermittent operation only. Outlet tepid water must only be used for emergency shower/eyewash stations. Continuous operation and/or use of tepid water for other applications may result in hazardous conditions and potential personal injury. Improper operation is not covered under warranty. LIFTING: Caution: Do not lift unit by grasping yellow enclosure. Yellow enclosure is not designed to support weight. When lifting, moving or aligning, always grasp the inlet and outlet piping only. NEVER GRASP THE UNIT BY THE ENCLOSURE. MOUNTING: Caution: DO NOT MOUNT YELLOW ENCLOSURE DIRECTLY TO THE WALL. Unit weighs 105 lb. (47.6 kg), empty, and is designed to be supported by the safety shower piping 04/17 Model 9400 Page 2 of 5

union connections. If wall, or post or beam mounting is desired, proper mounting is required to maintain access for testing and service. Unit must be mounted, so both halves of the yellow enclosure can be removed for service. See included Installation drawing. Remove plugs from inlet and outlet unions. Save for future use (when servicing the unit). Flush piping prior to connecting to inlet unions to eliminate debris. Connect outlet union to piping leading to shower/eyewash. Check for leaks. CAUTION: All inlet and outlet piping to the 9400 should remain independent and should not be tied in together at any point. STEAM: STEAM INLET PRESSURE MUST BE REGULATED TO 45 psi to 60 psi (3.1 bar to 4.1 bar). If a pressure regulator is required it is recommended that a pilot-operated steam pressure regulating valve be used to maintain the pressure setting under all flow conditions. If the supply pressure is greater than 75 psi (5.2 bar), then a pressure relief valve must also be used. For operation at other pressures, consult factory. 9400 contains internal steam trap. Redundant steam traps are not recommended. MAXIMUM STEAM TEMPERATURE IS 350⁰ F (176.7⁰ C). Pipe steam inlet with 1" Schedule 40 (minimum) pipe. Install a 1" ball valve for service isolation and as a safety shutoff. CAUTION: Always use back-up wrench when connecting to the 9400 unit. Do not allow rotation of any piping on station while connecting steam and water lines. Rotation of piping in or on station may cause damage and malfunction. CONDENSATE/DISCHARGE OUTLET: This line should be piped with 1" Schedule 40 (minimum) pipe to convenient drain, catch basin or open drain. If operated in freezing temperatures the drain line must be less than 6 in length and steeply sloped to prevent blockage due to freezing condensate. If the installation layout requires a longer or shallow sloped drain, the piping must be heat traced and insulated. CAUTION: This line must be free-flowing in order for the unit to operate correctly. NO STEAM TRAP SHOULD BE USED ON THIS LINE! ADDITION OF STEAM TRAP OR RESTRICTION WILL CAUSE SERIOUS SCALDING HAZARD! During operation of the 9400 unit, this line will discharge condensate and drain water from the system and some flash steam vapors. It must be piped so that there is no back pressure restriction. Do not tie other drain lines into condensate pipe. In order to prevent freeze damage to the water supply line to the 9400, to the safety shower/eyewash station and to safeguard against over temperature water conditions caused by solar radiation, heat tracing or other local heat sources, FREEZE AND SCALD PROTECTION VALVES MUST BE INSTALLED per industry standards prior to and after the station. If heat tracing is applied to the water supply line, the freeze protection valve may be installed as backup protection. Depending on system piping layout, additional freeze and over-temperature protection valves may be required. WATER: MINIMUM WATER INLET PRESSURE OF 55 psi (3.8 bar). Water pressure up to 90 psi (6.21 bar) is allowable as long as the downstream flow rate is regulated to less than 25 gpm (94.6 L/min). Pipe the water inlet using 1 1/4 Schedule 40 (minimum) pipe. Where sediment or mineral content is a problem, an inline filter is recommended. CAUTION: Always use a back-up wrench when tightening union connection to prevent damage. 04/17 Model 9400 Page 3 of 5

TEST FUNCTION OF UNIT: Turn on shower. Carefully monitor temperature for the first few minutes of operation. Check to insure initial flow does not contain brief shots of hot water. See troubleshooting for any problems. IMPORTANT: REPEAT TEST PROCEDURE WEEKLY! MAINTENANCE Consult the factory before attempting any maintenance. PROBLEM TROUBLESHOOTING REPAIR CHECKLIST 1. Cold water leaving heater 1. a. Insure steam supply is active and capable of providing 600 lb/hr (272 kg/hr). b. Insure flow through heater is sufficient to activate flow control valve. Minimum flow of 3 gpm (11.4 L/min) is required. c. Too much flow through heater? Heater is designed to handle a maximum flow of 25 gpm (94.6 L/min). 2. Output too hot a. Check that input temperature is not greater than 80º F (26.7º C). 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 04/17 Model 9400 Page 4 of 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: 1. DIMENSIONAL TOLERANCES: ±1/2". 2. RECOMMENDED WATER PRESSURE: 55 psi (3.79 bar) MIN 90 psi (6.21 bar) MAX. 3. RECOMMENDED STEAM PRESSURE: 45 psi to 60 psi (3.10 bar to 4.14 bar). 4. MAXIMUM STEAM TEMPERATURE: 350 F (177 C). 16 5/8" 3 1/4" MIN CLEARANCE TO WALL 14 1/4" MIN CLEARANCE FROM WALL PAGE 5 of 5 26" 9 3/4" 3 5/8" 3 3/8" 2 5/8" COLD WATER INLET (1 1/4" NPT UNION) TEMPERED WATER OUTLET (1 1/4" NPT UNION) 3' MIN DISTANCE TO SAFETY SHOWER STEAM INLET (1" NPT UNION) (14 1/4") 7 3/8" 7 1/8" 6 3/8" 4 5/8" C 2017 4 1/4" 9 5/8" (16 5/8") CONDENSATE DISCHARGE/OUTLET (1" NPT UNION) ECN NO. REVISED PER BY: 4930 ECN: 5198 JP DRAWN: DATE: CHK'D.: VC 10/01/14 CC APPROVED: DATE: FV 05/26/17 MODEL(S) 9400 AXION STEAM WATER HEATER 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM PART NUMBER REVISION SCALE: NA DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 R Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080243.D 7