HUD Radon Updates. April 19, 2017

Similar documents
Special Attention of: Notice H All Multifamily Hub Directors All Program Center Directors All Project Managers All Field Office Directors

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

Radon Test Results, Prentis II Apartments, West 10 Mile Road, Oak Park, Michigan (ASTI Project No )

Radon Program Going Forward

Public Review: MAMF - Proposed Revision 09/2016. Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily Buildings

Comprehensive Short-Term Radon Survey Report

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

Buying a New Home? How to Protect Your Famil... Page 1 of 6

PURPOSE. 03/08/18 REVISOR SGS/HR RD The purpose ofparts to is to protect public health by establishing

Property of Aztec Home Services LLC

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON?

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Detection Specialists, Inc. Love the Lungs You re With

Ventilation Techniques. Topic 5 - Audio 53

Radon Detection Specialists, Inc.

REAL ESTATE TRANSACTIONS

REAL ESTATE TRANSACTIONS

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

Radon Measurement Report

Kansas Radon Program Newsletter

EagleRidge High School. Radon Testing Plan

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Multnomah Education Service District

ALL RADON TESTS WERE SIGNIFICANLY BELOW

Radon Detection Specialists, Inc.

Bethel School District Radon Testing Plan

REDUCING RADON LEVELS BELOW 2.0 pci/l WHEN VIBRATION AND SOUND NOISES ARE IMPORTANT AND PIPES ARE NOT OPTIMALLY INSTALLED IN NEW RESIDENCES

radon Keeping your home safe from radon

Radon Detection Specialists, Inc.

Dealing With RADON in Real Estate Transactions

Woodlin Elementary School Date of Report March 14, 2018

Dealing With RADON in Real Estate Transactions

2.3 Definitions, General Provisions, and Radon Standards

Radon Detection Specialists, Inc.


Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships

Radon Detection Specialists, Inc.

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

Certificate of Completion

Illinois School District & Daycares

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

Call to Action Reduce Radon s Risk in America

RADON LAZERWEB SERVICES

City of Mahtomedi Park System Plan Public Hearing Draft: September 13, 2006

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

NSAW Radon Assessment 2017 QUESTIONS AND ANSWERS

Certificate of Completion

Illinois School District & Daycares

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

U.S. Environmental Protection Agency, Radon Division Washington, DC

Chapter 4. Route Window C12: Mile End Park and Eleanor Street Shafts

APPLICATION BRIEFING Prepared For: Submitted by: Date: Subject:

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

June 7, Mr. Brian. 150 North. Third Streett. Foote. On behalf. Master Plan Project. Disney Studios. I. Final EXHIBIT Q-1

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL

Design Architect s/applicant s Certification Of Threshold Criteria

Radon YOU: What you need to know to protect you and your family

Locations must be selected where the detector is not to be disturbed during the measurement period.

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

FEE SCHEDULE Construction Services and Permitting

YOU: What you need to know to protect you and your family

2014/0590 Reg Date 26/06/2014 Chobham

Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM

Brother Hydrick, Best wishes, Kent L. Brough Senior Landscape Architect. Answers from Landscape Architect Kevin Shields-

MD and Its Impact on Lab Facilities

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Open to Below: A Discussion of Allowed Floor Openings. Jay A. Ierardi, Ph.D., P.E., LEED AP. Kevin S. Hastings, P.E., LEED AP

Site Contacts for Your Location

IC Chapter 6. Home Improvement Fraud

Home Buyer s and Seller s Guide to Radon

Building Permit Type & Sub-Type Definitions

SECTION ELECTRICAL SYSTEMS COMMISSIONING

1 The development hereby permitted shall be carried out in accordance with the following approved plans:

MONTGOMERY COUNTY PLANNING DEPARTMENT

AS Fire detection, warning, control and intercom systems System design, installation and commissioning. Presented by: DAVID ISAAC

Certificate of Completion

FOUR MILE RUN VALLEY WORKING GROUP AND CHARGE Adopted April 16, 2016 Amended July 19, 2016

Radon Survey Final Report

A Review of a White Paper on Residential Fire Sprinklers

Pre-Bid Meeting Minutes 2018 A & E RFP February 6, :00 a.m.

2.7 ac park. TOTAL 5,403 DU 1,297,900 sf 1,105,450 sf 3.87 ac 5,563 DU 1,121,200 sf 1,105,450 sf 3.87 ac

January 1, 2014 Mandatory Effective Date

West Yorkshire Fire & Rescue Authority. Fire Protection Policy

STATE OF MAINE Department of Public Safety Office of State Fire Marshal 52 State House Station Augusta, ME

C-NRPP Quality Assurance Guidance for Radon Test Devices

Arc Flash and Selective Coordination

Explain in writing if the address of the building is different than the address on this form:

Home Buyer s and Seller s Guide to Radon

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

Adoption of The 2007 Dallas Fire Code

Connecticut Radon Measurement Training Program

Transcription:

HUD Radon Updates April 19, 2017

Radon Testing Standards HUD requires following the most recent version of the ANSI AARST standards for testing: MAMF 2017 (released 3/1/17) Multifamily Buildings standard for Multi Family properties 1. Testing by a certified Radon Professional 2. Test 100% of ground contact apartments 3. Test occupied non residential, ground contact rooms 4. Test 10% of apartments on each upper floor of each building 5. Test for a minimum of 2 days MALB 2014, Large Buildings standard for LEAN (extended care) facilities 1. and 2. same as above 3. Test occupied non residential, ground contact rooms and unoccupied ground contact rooms that can be converted for occupancy (rooms provided with HVAC) 4. Test 10% of rooms on 2 nd and 3 rd floor and at least one room on each floor above the 3 rd floor 5. Test for 3 4 significantly occupied days K

HUD Requirements for Refinance

Steps for Refinance Initial 25% or 100% screening and Radon Report: Multi Family Not required for low risk (Zone 3) radon zones. Required for medium risk (Zone 2) and high risk (Zone 1) radon zones. LEAN Required for ALL radon zones.

25% Screening Option Test per AARST except only test 25% of ground contact units (MAP), occupied rooms, and unoccupied rooms that can be converted to occupancy (LEAN). Still test upper floors per AARST standards. Cannot test just 25% in states that require 100%: IA, IL, ME, OH. NEW MAMF 2017 Policy REQUIREMENT: If any result is 4.0 pci/l, Followup testing procedures to include 100% of all ground contact areas and dwelling units, and not less than 10% of the dwelling units on each upper floor in all buildings associated with the testing survey (Section 7.1.8.1 Elevated Radon (e.g., 4.0pCi/L))

25% Screening Option HUD will still permit initial testing of 25% ground contact units when applicable; however, if any results are elevated ( 4.0pCi/L), a repeat assessment must be conducted and include ALL previously tested units (ground contact and upper floors), and 100% of the remaining untested, ground contact units across the entire property. Retest locations that were <4.0 pci/l Retest the test locations that were 4.0 pci/l Test any location where the initial test was voided, lost or tampered with Test 100% of ground floor units If 100% follow up testing is not performed, mitigate 100%

Whether to Choose 25% or 100% Testing Testing 100% initially may be cheaper than testing 25% with follow up testing of the remaining 100% due to the multiple mobilizations and reports. If one or more elevated results are anticipated, the 100% ground contact full assessment is the most cost effective first step. Suggested: Zone 1 (High Radon) 100% Initial testing Zone 2 (Moderate Radon) 100% Initial testing Zone 3 (Low Radon) 25% Initial screening may be a safe bet. (Relevant for LEAN projects only)

Challenges of Designing a LEAN Sampling Plan Determining an accurate number of samples. What rooms are occupied or are supplied with HVAC and easily converted for occupancy.

Radon Mitigation Systems

Radon Mitigation Systems Installed on Existing Buildings Multi Family (Multi Family Buildings) ANSI/AARST RMS MF 2014 Radon Mitigation Standards for Multifamily Buildings (Single Family structures) ASTM E2121 13 Standard Practice for Installing Radon Mitigation Systems in Existing Low Rise Residential Buildings LEAN ANSI AARST RMS LB 2014, Radon Mitigation Standards for Schools and Large Buildings

O&M Plan Required for Active (Fan Powered) Mitigation Systems Maintenance of the Active Mitigation System is required for the duration of the insured mortgage Development and implementation of a formal O&M Plan is required. Key components: Routine monitoring and equipment maintenance schedule Provisions for Non routine repairs i.e. fan replacement Ongoing monitoring of Radon levels (testing every 2 years) Records management Include the O&M Plan in the amended Radon Report upon completion of mitigation system installation

Radon Resistant Construction for 221(d)(4) NC Projects

Radon Resistant Construction 221(d)(4) On March 28, 2017, Tom Bernaciak at HUD Headquarters provided an email with clarification on the Radon Report requirements for MAP 221(d)(4) New Construction Projects. Here are the major points of clarification: The language in Section 9.5.C.2.a.i requiring a radon report at either the pre application or the firm commitment application refers to reporting testing conclusions as part of a substantial rehabilitation or refinance application, not to new construction. For new construction projects, a report by a radon professional is required only after testing has been conducted, at completion of construction and prior to final endorsement in accordance with Section 9.5.C of the MAP guide. HUD will rely on the project Architect (who has E & O insurance) to incorporate any required radon resistant construction design or radon mitigation system(s) into the architectural plans. HUD encourages the Architect to seek technical advice from a licensed radon professional should they believe it to be necessary in their professional judgment.

Radon Resistant Construction 221(d)(4) Radon Zone 1: Must meet ALL of the requirements of ASTM E1465 08a for installation of passive mitigation systems. Everything but the powered fan. Radon Zones 2 and 3: Must meet the requirements of Sections 6.2 6.4 of ASTM E1465 08a Section 6.2 Ground cover. Section 6.3 Foundation walls. Section 6.4 Gas permeable layer.

Radon Questions Questions??