T4398A,B High Performance Electric Heat Thermostats

Similar documents
T4098A,B Deluxe Electric Heat Thermostats

T4398A,B Precision Electric Heating Thermostat

C554A Cadmium Sulfide Flame Detector

T7079A,B Solid State Remote Temperature Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T6984F,G Electronic Floating Control Thermostats

The T6140A,B Remote Bulb Temperature Controller

T834C Heating-Cooling Thermostat

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

C6097A,B Pressure Switches

Commercial/Industrial Combustion Control Level Three Announcement

T7984 A,B,C Electronic Modulating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats

T8011R Programmable Heat Pump Thermostat

CR7075 Two-Stage Lighting Controller

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

RA889A Switching Relay

T874 Multistage Thermostat and Q674 Subbase

F25F Media Air Cleaner

T8411R Electronic Heat Pump Thermostat

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

F150E Media Air Cleaner

C7232A,B Sensor and Controller

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE

H1008A,D Automatic Humidity Controls

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

IS Series Pressure Sensing Switches

F200E Charged-Media Air Cleaner

L8151A Triple Aquastat Relay

HE365A,B Powered Flow-Through Humidifier

T8524 Deluxe Electronic Thermostat

T8034C Heating/Cooling Thermostats

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

T7200D,E Series 2000 Commercial Microelectronic Thermostats

M6063A Compact Rotary Mixing Valve Actuator

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

CT500 Electronic Thermostat

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

Home and Building Control Home and Building Control Helping You Control Your World

Deluxe Programmable Heat Pump Thermostat T8611M

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

Deluxe Programmable Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

T8112 Programmable Thermostat

T8600D Chronotherm IV Deluxe Programmable Thermostats

C7004B Flame Rod Holder

T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase

T8602C Chronotherm IV Deluxe Programmable Thermostats

CT2700 An Electronic Round Programmable Thermostat

Q382A,B Pilot Burners

Q7300L Series 2000 Commercial Thermostat Subbases

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8401C Electronic Thermostats

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

Instructions For A and Flame Simulators

HE360 Powered Flow-Through Humidifier

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

Q7100A,C,D Thermostat Subbases

CT1500, CT1501, CT1502, CT1503

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

T8112C,DElectronic ProgrammableThermostats

HE360A,B Powered Flow-Through Humidifier

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

UV100E Ultraviolet Air Treatment System

T4360G, T6360D, T6360E Line Voltage Thermostat

TP970 Series CONVERTASTAT Kits

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

T7100D Microelectronic Conventional Thermostat

Powers TM Controls ET 134 Line Voltage Room Thermostats

P7810A-D Pressuretrol Controller

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

T8400C Universal Electronic Thermostats

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

RA889A Switching Relay

D896 Automatic Vent Damper

T8000C Programmable Thermostat

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

F59A Console 3-Speed Electronic Air Cleaner

T8400C and T8401C Electronic Thermostats

VisionPRO 8000 with Wi-Fi

Installation Instructions

Oil-Fired Furnace Single Stage Heat Pumps No- Auxiliary Heat. Electric Air Conditioning

UV100A Ultraviolet System

HE420A Steam Power Humidifier

TC-5231 Series, TC-5232, & TC-5241 Series

Must be installed by a trained, experienced technician

Transcription:

T498A,B High Performance Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides 2 F (1 C) sensitivity with minimum droop. UL listed up to 5 kw at 277 Vac. Replaces virtually all standard wall-mounted line voltage thermostats. Includes long-lasting Micro Switch mechanism. Color-coded leads for easy installation. Cover thermometer indicates room temperature. Rugged, plastic mounting base. GENERAL Contemporary white finish complements almost any decor. The T498A,B High Performance Electric Heat Thermostats provide precise line voltage control of resistance-rated electric heating equipment. Snap action switch makes heating circuit on temperature fall; T498B models make double line break with setting knob at OFF position. Contents General... 1 Features... 1 Specifications... 2 Ordering Information... 2 Installation... Settings and Adjustment... 4 Checkout... 5 Operation... 6 Copyright 1996 Honeywell Inc. All Rights Reserved X-XX UL 68-0147-2

SPECIFICATIONS IMPORTANT The Specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. For exact engineering specifications, contact your Honeywell sales representative. TRADELINE MODELS TRADELINE models are selected and packaged to provide ease of stocking and handling and also maximum replacement value. TRADELINE model specifications are listed in Table 1. Electrical Ratings (Noninductive Resistive Loads): 22A at 120/208/240 Vac; 19A at 277 Vac, 60 Hz. Wiring Connections: 6 in. (150 mm) copper leadwires, suitable for connecting to aluminum wiring if approved special service CO/ALR connectors are used. Sensing Element: Vapor-filled dual diaphragm. Thermometer Temperature Range: 50 to 90 F (10 to 0 C). Differential: 2 F (1 C), nonadjustable. Setpoint Adjustment: Dial on front of thermostat. Dimensions: See Fig. 1. Barometric Sensitivity: 1 F /500 ft (0.5 C/kPa). Mounting: Mount directly on vertical 2 x 4 in. outlet box, or on 4 x 4 in. outlet box with ring adapter (ordered separately), using 6-2 Robertson slotted screws. Approvals: Underwriters Laboratories Listed: File no. E4744, guide no. XAPX. Canadian Standards Association Listed: File no. LR122. Accessories: 272804A Range Stop and Locking Screw Assembly: Includes locking cover screws, Tinnerman cilps, wrench and range stops two plastic pins to insert inside cover for fieldselection of minimum and maximum temperature settings. Temperature Setting Range: 50 to 80 F (10 to 25 C). Table 1. Thermostat Specifications. Model Number T498A T498B Switching Spst; makes single line break on temperature fall. Dpst; makes double line break with setting knob at OFF position. Temperature Rating F ( C) Finish Includes 50 to 80 (10 to 25) White Cover thermometer, temperature range stops and locking cover. 50 to 80 (10 to 25) White Cover thermometer, temperature range stops and locking cover. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number or specify: 1. Model Number. 2. Switching. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-486 In Canada Honeywell Limited/Honeywell Limitée, 5 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0147 2 2

FRONT VIEW 80 70 60 50 F 4-/8 (111) SIDE VIEW 1-/4 (48) /4 (19) 1/2 (1) 2-1/8 (54) -1/4 (8) CAUTION 1. Disconnect power supply to prevent electrical shock or equipment damage. 2. If connecting with aluminum conductors, use CO/ ALR solderless wire connectors to avoid fire hazard.. Do not remove thermostat cover until wiring is complete to avoid damaging the sensing element. Location Install a vertical outlet box, which is used to mount the thermostat on, about 5 ft (1.5 m) above the floor in an area with good air circulation at room temperature. 2-7/8 (7) 1-1/2 (9) RECYCLING NOTICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of any control containing mercury in a sealed tube. INSTALLATION 1/2 (1) Fig. 1. T498 approximate dimensions in in. (mm). M5795A When Installing this Product... 1. Read these instructions carefully. Failure to follow these instructions could damage the product or cause a hazardous condition. 2. Check the ratings on the product to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. WARNING HIGH VOLTAGE CONTROL. ELECTRICAL SHOCK HAZARD. Follow local codes and ordinances when installing this thermostat. Improper handling can cause serious injury or death. Do not install the thermostat where it may be affected by: drafts or dead spots behind doors, in corners or under cabinets. hot air from convectors. radiant heat from sun or appliances. concealed pipes and chimneys. unheated (uncooled) areas such as an outside wall behind the thermostat. Wiring and Mounting CAUTION 1. Handle the thermostat with care to avoid damaging the sensing element or control. 2. Use a separate limit control in the heating appliance. IMPORTANT If locking cover feature is desired, insert the locking cover clip in the thermostat base before mounting the thermostat on the wall. See Fig. 7. Replacement Applications Disconnect power to thermostat to prevent electrical shock or equipment damage. All wiring must comply with local electrical codes and ordinances. Remove the old thermostat from the wall, taking care not to damage the wiring insulation. Check the old wire insulation for cracks, nicks or fraying. Apply approved electrical tape to insulate wires or replace wires as necessary. Do not remove T498 Thermostat Cover. Using wire connectors approved for No. 12 wires, make line voltage connections directly to leadwires on thermostat. See Figs. 2 and for typical wiring connections. Prebend and push solid wires into the outlet box. Remove the thermostat cover by grasping the top and bottom edges and pulling outward away from the base. Turn the setting dial so the indicator is at the 12 o clock position to prevent damaging the sensing element when mounting the thermostat. Mount the thermostat on the outlet box as shown in Fig. 4. Secure the thermostat by tightening the two mounting screws. 68-0147 2

80 60 55 T498A,B HIGH PERFORMANCE ELECTRIC HEAT THERMOSTATS T498A L1 WALL T1 4 THERMOSTAT BASE 1 L1 (HOT) SOLDERLESS CONNECTORS 2 ELECTRIC HEATER OUTLET BOX SETTING DIAL INDICATOR 75 70 65 50 L2 1 2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. USE SPECIAL SERVICE CO/ALR SOLDERLESS CONNECTORS WHEN CONNECTING ALUMINUM CONDUCTORS OR A FIRE HAZARD MAY RESULT. MOUNTING SCREWS (2) M5797 Fig. 4. Mounting thermostat to outlet box. 4 USE A SEPARATE LIMIT CONTROL IN THE HEATING APPLIANCE. BREAKS AND REMAKES BELOW -1 F (-5 C); NORMALLY THERMAL ACTIVATED. BREAKS ON TEMPERATURE RISE; MAKES ON TEMPERATURE FALL. M5791B Fig. 2. Typical wiring connections for T498A. L1 T498B T1 L2 T2 5 RED WIRE 6 New Applications Disconnect power supply to prevent electrical shock or equipment damage. All wiring must comply with local electrical codes and ordinances. Run line voltage wiring to the thermostat location. Do not remove T498 Thermostat Cover. Using wire connectors approved for No. 12 wires, make line voltage connections directly to leadwires on thermostat. See Figs. 2 and for typical wiring connections. Prebend and push solid wires into the outlet box. Remove the thermostat cover by grasping the top and bottom edges and pulling outward away from the base. Turn the setting dial so indicator is at the 12 o clock position to prevent damaging the sensing element when mounting the thermostat. Mount the thermostat on the outlet box as shown in Fig. 4. Secure the thermostat by tightening the two mounting screws. L2 1 L1 (HOT) 1 2 4 5 6 2 SOLDERLESS CONNECTORS POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. ELECTRIC HEATER USE SPECIAL SERVICE CO/ALR SOLDERLESS CONNECTORS WHEN CONNECTING ALUMINUM CONDUCTORS OR A FIRE HAZARD MAY RESULT. BREAKS AT POSITIVE OFF AND REMAKES UNDER 1 F ( 5 C); NORMALLY THERMALLY ACTIVATED. BREAKS ON TEMPERATURE RISE; MAKES ON TEMPERATURE FALL. USE A SEPARATE LIMIT CONTROL IN THE HEATING APPLIANCE. BREAKS AT POSITIVE OFF ONLY; NOT THERMALLY ACTIVATED. DO NOT CONNECT GROUNDED CONDUCTOR (NEUTRAL) ON 120 OR 227V CIRCUITS. INSULATE AND TAPE OR CUT OFF RED WIRES IF UNUSED. M5792B Fig.. Typical wiring connections for T498B. 4 SETTINGS AND ADJUSTMENTS Calibration The T498 Thermostats are calibrated at the factory using precise instruments under closely controlled conditions. Recalibration should not be necessary. Allow the thermostat to operate for several hours before checking calibration. The T498 Thermostat vapor-filled dual diaphragm sensing element is affected by barometric pressure and altitude. Temperature deviations of 1 F (0.5 C) are normal. If the thermostat is mounted in a suitable location (as instructed in the Location section) and still appears out of calibration, check calibration as follows. Check Calibration Remove the thermostat cover and set it aside for several minutes because radiant heat from your hands will affect the thermometer reading. Turn the setting dial clockwise until the switch makes (click sound). The heating equipment and fan start. No recalibration is necessary if the thermostat switch makes with the thermostat setting at the same temperature as indicated on the thermostat cover thermometer. 68-0147 2 4

If the thermostat setting differs from the thermometer, record the temperature difference and recalibrate as instructed in the Recalibration Procedure section. BACK OF THERMOSTAT COVER Recalibration Procedure Note the temperature difference between the thermostat setting and the thermometer. Turn the setting dial clockwise until the switch makes (click sound). Firmly hold the setting dial with one hand. Using the other hand, turn the outer scale ring counterclockwise until the 12 o clock position of the scale ring is the same temperature as the cover thermometer. See Fig. 5. Wait five minutes and recheck the calibration. 75 24 70 20 C 65 16 60 12 55 INSERT RANGE STOP PINS IN SLOTS. THERMOSTAT BASE M5801 Fig. 6. Setting range stops. THERMOSTAT BASE 80 75 70 65 60 55 SETTING KNOB AT 12 O'CLOCK POSITION 50 SCALE RING SETTING KNOB THERMOSTAT COVER LOCKING COVER CLIP M5796 Fig. 5. Calibrating thermostat. Setting Range Stops Use the range stops, included, to limit the maximum and minimum temperatures that may be set. Move the thermostat setting dial to the desired maximum temperature. Remove the thermostat cover. Insert the range stop pins in the desired minimum and maximum temperature setting positions on the back of the thermostat cover. See Fig. 6. Make sure the pins are completely seated before replacing the thermostat cover. Replace the thermostat cover and check the range stops. Locking Cover The thermostat cover may be locked using the locking cover screws included. Locking the cover prevents unauthorized tampering of the thermostat temperature setting. Remove the thermostat cover. Insert the locking cover clip (included) into the slot at the back of thermostat base as shown in Fig. 7. Using the Allen wrench, insert the locking cover screw into the clip. Secure the screw in place until it is flush with the thermostat base. LOCKING COVER SCREW CHECKOUT ALLEN WRENCH M5798 Fig. 7. Locking cover. IMPORTANT Make sure that all wiring connections are secure before beginning checkout. After thermostat installation is complete, check the operation as follows: Move the thermostat setting knob clockwise until the switch makes (click sound); the electric heater starts. Move the setting knob counterclockwise all the way; the switch breaks and the electric heater starts to cool. Allow the thermostat to operate for several hours to determine the appropriate temperature setting. Adjust the setting as necessary. The precise temperature control of the T498 allows the user to select a lower temperature setting, which saves energy while maintaining comfort. 5 68-0147 2

OPERATION The T498 Thermostat provides precise temperature control of resistance-rated electric baseboard heating equipment with minimum droop. The T498 controls room temperature within 2 F (1 C), regardless of the load of the baseboard heater. The vapor-filled dual diaphragm sensing element is more sensitive to temperature changes than a bimetal sensor. This accuracy, usually associated with low voltage thermostats, is now available for line voltage control. Electric heat thermostats are often affected by the heat generated in the control. Temperature control points can vary or droop 2 to 4 F (1 to C) depending on the load demand. Temperature settings are adjusted to offset this. The T498 provides precise control with minimum droop. This allows better control of room temperatures from day to night and season to season while saving energy. 68-0147 2 6

7 68-0147 2

Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9 Helping You Control Your World Printed on recycled paper containing at 68-0147 2 C.H. Rev. 4-96 Printed in U.S.A. least 10% 8 post-consumer paper fibers. www.honeywell.com/yourhome