Original operating instructions Safety switch with guard locking AC901S AC902S

Similar documents
More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode)

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

/ / 2018

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

SensaGuard TM Integrated Latch Installation Instructions

ISIS SAFETY SYSTEM Installation guide

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Datasheet - MZM 100 ST-SD2PREM-A

SCHMIDT LED Measured Value Display MD Instructions for Use

Datasheet - MZM 100 B ST2-SD2PREM-A

Important Safety Notice

One giant leap for safety: AZM400.

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Operating Guide Safe Torque Off

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

MANUAL Oil Level Sensor

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

SAFETY RELAY APPLICATION

Datasheet - MZM 100 ST2-1P2PWREM-A

Original instructions JSNY7 Magnetic switch

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Original instructions Sense7-series Non-contact coded safety switch

Installation instructions

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

5, SE GÅNGHESTER,

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Simply safe. Transponder-coded safety switch CET with guard locking

MANUAL Overflow sensor NVF-104/34-PF

Operating instructions

Non-contacting guards

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

EN Z Subject to change due to technical improvements! Operating instructions

Operating Guide Safe Torque Off

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Datasheet - AZM 161SK-12/12RK-024

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Safety Function: Single-beam Area Access Control (AAC)

TE 1000-AVR. English. Printed: Doc-Nr: PUB / / 000 / 04

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

DOCUMENTATION IPS640

Datasheet - AZM 161SK-12/12RK-024

Magnetically Coded Non-contact Switch (MC2)

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Danfoss gas detection units

Operating Manual MS220KA and MSR220KA

Panel Mounted Fault Annunciator Series

PROTECT SRB 200EXi-1A

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

M2500 Engine Controller Installation Manual

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

Detector switch - Dual Tech SCS

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

DOCUMENTATION IPS640

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Flameproof Manual Call Points

Connections, displays and operating elements C D E G H. Installing the control unit

Connection of auxiliary heater in coolant circuit of W12 engine

Multifunctional Gate Box MGB. More than safety.

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

GLEB Kitchen exhaust fan

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Operator systems for garage doors Highline 10, 15, 18

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Datasheet - AZM ZRK 24 VAC/DC

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

GMA Panels with double busbar

SACE PR021/K SIGNALLING UNIT

Panel Mounted Fault Annunciator Series

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

PERMACONN PM1030 Includes DI300. Installation Manual

Danfoss gas detection units

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Consultant Specification AGILE Wireless Fire Detection System

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

First of all, what is a safety-related

Functional Safety Manual Oil Leak Detector NAR300 System

Installation and operation manual

Installation, operating and servicing instructions

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

Intelligent Security & Fire Ltd

Proservo NMS5- / NMS7-

Transcription:

Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017

Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5 4 Functions and features...5 5 Structure and operating principle...7 5.1 Actuator version...7 5.2 Version AC901S (guard locking by spring force)...7 5.3 Version AC902S (guard locking by solenoid force)...8 5.4 Mechanical release...9 6 Installation...10 6.1 Installation instructions...10 6.1.1 Changing the actuating direction... 11 6.2 Protection against environmental influences... 11 7 Electrical connection... 11 7.1 Wiring...12 8 Set-up...12 8.1 Setting of the AS Interface address...12 8.2 Configuration in the AS Interface safety monitor...12 8.2.1 Monitor with extended functions...13 9 Operation...14 9.1 LED indicators / AS-Interface status messages...14 10 Function check and troubleshooting...14 10.1 Mechanical function check...14 10.2 Electrical function check...15 10.3 Troubleshooting...15 11 Scale drawing...16 12 Technical data...17 13 Terms and abbreviations...18 14 Data bit table...19 2

15 Standards and approvals...22 15.1 Directives and standards...22 15.2 Approvals...22 3

1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 1.1 Explanation of symbols Instruction > Reaction, result Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note. 4 WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. 2 Safety instructions Read this document before setting up the product and keep it during the entire service life. The product must be suitable for the corresponding applications and environmental conditions without any restrictions. Only use the product for its intended purpose ( Functions and features). If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur. The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator. Installation, electrical connection, set-up, operation and maintenance of the unit must be carried out by qualified personnel authorised by the machine operator. Protect units and cables against damage. Also adhere to the safety instructions for the operation of the whole installation. The applicable technical standards for the corresponding application must be complied with.

For installation the requirements according to EN 60204-1 must be observed. Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. After installation of the system perform a complete function check. Only use the unit under the specified operating conditions ( 12 Technical data). In case of special operating conditions please contact the manufacturer. Safety switches fulfil a personal protection function. Incorrect installation or tampering can lead to serious injury. Safety components must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. On this point, take particular note of the measures to reduce the possibilities of bypassing in EN ISO 14119: 2013. The switching operation must only be triggered by actuators specially provided for this purpose which are permanently connected to the safety guard. A complete safety-related system normally consists of several signalling devices, sensors, evaluation units and concepts for a safe shut-down. The manufacturer of a machine or installation is responsible for a correct and safe overall function. All safety instructions and specifications in the operating instructions of the AS Interface safety monitor must be adhered to. 3 Items supplied 1 AS-Interface safety switch type AC90xS 1 operating instructions safety switch with guard locking, ident no. 7390914. If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. 4 Functions and features AS-Interface safety switches type AC901S/AC902S operate as slaves on the safety bus AS Interface Safety at Work and function as electromagnetic interlock devices with guard locking. The actuator has a low coding level. In combination with a guard and the machine control system this safety component prevents the safety guard from being opened while there is potential of 5

exposure to a mechanical hazard. For the control system this means the following: Switch-on commands which cause hazardous situations must become active only when the safety guard is in a protective position and the guard locking in locked position. The locked position of the guard locking must be released only when the hazardous situation is no longer present. Closing and guard locking a safety guard must not cause automatic start of a dangerous machine function. A separate start command has to be given. For exceptions see EN ISO 12100 or relevant C standards. Before safety switches are used, a risk assessment must be performed on the machine, e.g. according to EN ISO 13849, Safety of machinery - Safety-related parts of control systems EN 12100-1, Safety of machinery - General principles for design - Risk assessment and risk reduction Correct use includes compliance with the relevant requirements for installation and operation, in particular IEC 62061, Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems EN ISO 13849, Safety of machinery - Safety-related parts of control systems EN 14119, Interlocking devices associated with guards EN 60204-1, Electrical equipment of machines. The user is responsible for a safe integration of the device into a safe overall system. Validate the whole system, e.g. to EN ISO 13849 2. If the simplified procedure to EN ISO 13849-1: 2016 (section 6.3) is used for validation, the performance level (PL) may be reduced in the event of several units being connected in series. If a data sheet is supplied with the product, the specifications of the data sheet apply in case of deviations from the operating instructions. 6

5 Structure and operating principle AS-Interface safety switches, type AC901S/AC902S feature a slave interface to the safety bus AS Interface Safety at Work. They enable locking of movable safety guards. In the switch head there is a rotating switch cylinder that is locked/released by the guard locking bolt. When the actuator is introduced/removed and the guard locking is activated/ unlocked, the locking bolt is moved. The switching contacts are activated. When the switch cylinder (guard locking active) is locked, the actuator cannot be removed from the switch head. For reasons of design the guard locking can only be activated if the protective equipment is closed (protected against incorrect locking). Position monitoring of the safety guard and monitoring of interlocking are performed via two separate contact elements (door monitoring contact SK and solenoid monitoring contact ÜK). When the safety guard is closed and the guard locking is active, each AS-i safety switch transmits a switch-specific unique safety code sequence comprising 8x4 bits via the AS Interface bus. This code sequence is evaluated by an AS Interface safety monitor. The positively driven contact SK for door monitoring is represented by the AS Interface input bits D0 and D1. The solenoid monitoring contact ÜK is represented by the AS Interface input bits D2 and D3. Configure the safety switch in the AS Interface safety monitor accordingly (refer to the operating instructions of the AS Interface safety monitor and the data bit table). The fail-safe switch is designed so that the exclusion of internal faults according to EN ISO 13849 2: 2013, Table A4 can be assumed. 5.1 Actuator version Actuator S for the AS-i safety switches AC901S/AC902S without insertion funnel. 5.2 Version AC901S (guard locking by spring force) Additional measure for personal protection against dangerous overtravel movements: 7

Connect the black AS-Interface cable (auxiliary power) to the AS-Interface splitter via a standstill monitor or via the safe switch-on delay of a two-channel AS-Interface safety monitor (e.g. door locking for the duration of the delay time). The switches are connected to the AS-Interface splitter. The locking bolt is held in locked position by spring force and is electromagnetically released. The spring-interlocked guard locking operates normally closed. In the event of interruption of the solenoid power supply the safety guard cannot be opened immediately. For process protection the interlocking solenoid can be switched by software via the AS Interface output bit D0. If the safety guard is open when the power supply is interrupted and the guard is then closed, guard locking is activated. This can lead to persons being locked in unintentionally. 5.3 Version AC902S (guard locking by solenoid force) Use as guard locking for operator protection is only possible in special cases after a strict assessment of the risk of accident (see EN ISO 14119: 2013, section 5.7.1). In the event of interruption of the solenoid power supply the safety guard can be opened immediately! The locking bolt is electromagnetically held in locked position and released by spring force. The guard locking operates normally open. For process protection switch the interlocking solenoid by software via the AS Interface output bit D0. Close the safety guard and activate the guard locking. Insert the actuator into the safety switch. > > The locking bolt is released. AC901S: The locking bolt passes into the locked position by spring force. AC902S: The locking bolt passes into the locked position by applying the operating voltage of the solenoid. > > The safety contacts close. > > The whole safety code sequence (8 x 4 bits) is transmitted via the AS Interface input bits D0 to D3. Deactivate the guard locking and open the safety guard. 8

AC901S Apply the operating voltage of the solenoid and release the guard locking via the AS-Interface output bit D0. > > The guard locking is deactivated, the solenoid monitoring contact ÜK opens. The value pair 0, 0 is transmitted in every bus cycle via the AS Interface input bits D2 and D3. Remove the actuator. > > The door monitoring contact SK is positively opened and the guard locking is blocked in this position (protection against unintentional closing). The values 0, 0, 0, 0 are continuously transmitted via the AS Interface input bits D0 to D3. AC902S Switch off the operating voltage of the solenoid and release the guard locking via the AS-Interface output bit D0. > > The guard locking is deactivated, the solenoid monitoring contact ÜK opens. The value pair 0, 0 is transmitted in every bus cycle via the AS Interface input bits D2 and D3. Remove the actuator. > > The door monitoring contact SK is positively opened and the guard locking is blocked in this position (protection against unintentional closing). The values 0, 0, 0, 0 are continuously transmitted via the AS Interface input bits D0 to D3. 5.4 Mechanical release In the event of malfunction the guard locking can be released with the mechanical release irrespective of the state of the solenoid ( 6.1.1). Remove the locking screw. Using a screwdriver, turn the mechanical release by approx. 180 in direction of the arrow. The locking screw must be returned to its original position and sealed after use (for example with sealing lacquer). After unlocking perform a complete function check. For further information we refer you to EN ISO 14119: 2013, section 5.7.5.1. 9

6 Installation Do not use safety switches and actuators as an end stop and only mount in assembled condition. At ambient temperatures higher than 40 C protect the switch against contact with inflammable material or personnel. 6.1 Installation instructions Mount the safety switch so that access to the switch is difficult for operators when the safety guard is open and the operation of the mechanical release is still possible. address programming, inspection and replacement by authorised personnel is possible. Insert the actuator into the actuating head. Mount the safety switch positively. Permanently connect the actuator to the safety guard so that it cannot be detached (e.g. using the enclosed non-removable screws), alternatively rivet or weld. Fit an additional end stop for the movable part of the safety guard. To fix the fail-safe switch and the actuator adhere to EN ISO 14119:2013, sections 5.2 and 5.3. To minimize defeat possibilities of an interlocking device adhere to EN ISO 14119:2013, section 7. 10

6.1.1 Changing the actuating direction C D B A Remove the screws from the actuating head. Set the required direction. Tighten the screws with 0.6 Nm. Close the unused actuating slots with the supplied slot covers. 6.2 Protection against environmental influences A lasting and correct safety function requires that the actuating head must be protected against the penetration of foreign bodies such as swarf, sand, blasting shot etc. Cover the actuating slot, the actuator and the type label during paint work. 7 Electrical connection For use and operation as per the UL requirements use an isolating transformer or a power supply with secondary overcurrent protection (3 A). 11

7.1 Wiring The safety switch is connected to the bus system with an M12 connector and a 4-pole cable. Additionally, via a passive AS Interface splitter with a yellow and black AS Interface cable. 4 3 1 2 1. AS-Interface + 2. Auxiliary voltage 3. AS-Interface - 4. Auxiliary voltage 24 V 8 Set-up 8.1 Setting of the AS Interface address The address can be set before or after installation. Set the AS Interface address of the safety switch using an AS Interface programming device. Addresses 1 to 31 are valid. Connect the programming device to the M12 connector of the safety switch using a programming cable. Address 0 is the default setting on delivery (the AS Interface LED Fault is lit during operation). 8.2 Configuration in the AS Interface safety monitor Refer to the operating instructions of the AS Interface safety monitor and the data bit table. Configure the safety switch in the AS Interface safety monitor with the set AS Interface address, for example, as follows: Dual-channel dependent synchronisation time = infinite ( ) In this operating mode, the safety guard must be opened each time prior to restarting in order to perform the start-up test. Dual-channel independent The guard locking is opened or closed via the output D0. When the guard locking is open, the safety circuit shuts down. It is not necessary to open the door. Safety is provided again when the guard locking is closed. 12

The dual-channel feature and the door contact are not tested in this configuration. Take additional measures for testing outside the monitor. 8.2.1 Monitor with extended functions For the monitor with extended functions the following configuration is possible: dual-channel conditionally dependent independent: In-1 The guard locking is opened or closed via the output D0. When the guard locking is open, the safety circuit shuts down. It is not necessary to open the door. Safety is provided again when the guard locking is closed. The switch is monitored for malfunction, the door contact (SK) must not switch before the guard locking contact (ÜK). Observe the following if in the event of a spring-interlocked safety switch AC901S the interlocking solenoid is switched on (released) in the operating mode door locking for duration of the delay time via the second release contact of a dualchannel safety monitor and a PLC: It is not possible to switch off the interlocking solenoid by means of the monitor alone. The control system (PLC) must switch off the interlocking solenoid in the locked position via the AS Interface output D0 = 0 in order to re-establish the switch-on conditions for the first OSSD. Switch on the AS Interface output with D0 = 1 so that the interlocking solenoid can be released by the second safety output of the monitor. Status signals (not relevant to safety) The status of the AS-Interface input bits D0 and D1 for door monitoring and AS- Interface input bits D2 and D3 for solenoid monitoring can also be polled by the control system (PLC) (see the operating instructions of the AS Interface safety monitor). 13

9 Operation 9.1 LED indicators / AS-Interface status messages Status LED 3 Fault and LED 4 Power green is lit Device status normal operation red and green are lit slave address = 0 or offline phase 1: LED green 2: LED red 3: LED red FAULT 4: LED green Power The AS Interface bus status is indicated by two LEDs (Power, Fault). Two additional LEDs can be connected via the AS Interface bus, e.g. to indicate the status signals (see Status signals and Technical data). 10 Function check and troubleshooting WARNING Errors during installation and function check can lead to fatal injury. Before the function check ensure that there are no persons in the hazardous area. Adhere to the applicable accident prevention regulations. After installation and each error carry out a complete check of the safety function. 10.1 Mechanical function check The actuator must slide easily into the actuating head. 14

Close the safety guard several times to check the function. 10.2 Electrical function check 1. Switch on the operating voltage. 2. Close all safety guards. In case of guard locking by means of solenoid force activate the guard locking. The machine must not start automatically. It must not be possible to open the safety guard. 3. Activate operation in the controller It must not be possible to deactivate the guard locking as long as the operation is active. 4. Switch off the operation in the controller and deactivate the guard locking. The safety guard must remain locked until there is no longer a risk of injury. It must not be possible to start the machine as long as the guard locking is deactivated. Repeat steps 2-4 for every safety guard individually. 10.3 Troubleshooting In case of damage or wear replace the complete switch and actuator assembly. Replacement of individual parts or assemblies, especially of the actuating head, is not permitted! The production year is indicated in the bottom right corner of the type label. See EN ISO 14119: 2013, section 8.2 for notes on possible time intervals. To ensure a trouble-free long-term operation regular inspections are necessary. Check the unit for the following points: correct switching function secure mounting of the components dirt and wear loose connectors Exclusion of liability under the following circumstances: if the unit is not used for its intended purpose 15

non-compliance with the safety regulations installation and electrical connection by non-authorised personnel failure to perform function checks. 11 Scale drawing 190 240 41,4 55 30 44 38,5 25 144 M12x1 41,4 46 153,4 16

12 Technical data AC901S, AC902S Safety switch with guard locking The device can be used in applications according to EN ISO 13849-1: 2016 up to PL d. Mechanical data Housing material reinforced glass-fibre thermoplastic Degree of protection to IEC 529 IP 67, mating connector plugged in Lifetime 1 x 10 6 operating cycles Ambient temperature -20...55 C Installation position freely selectable Max. approach speed 20 m/min Actuation frequency 1200 / h Actuation force 35 N Extraction force 30 N (not locked) Retention force 20 N Locking force F max 2500 N Locking force F Zh in accordance F Zh = (F max / 1.3) = 2000 N with the test principles GS-ET-19 Weight approx. 0.5 kg Switching principle SK, ÜK positively driven, slow-action switching element Interlocking solenoid Solenoid operating voltage (auxiliary voltage on the black AS- Interface cable) Solenoid operating current DC 24 V +10% / -15%, 8 W power supply with safe isolation (IEC 60742, PELV) 300 ma Duty cycle 100 % Connection type M12 connector Minimum travel and overtravel Approach direction actuator S (standard) Horizontal (h) and vertical (v) 24.5 + 5 AS-Interface specifications AS-Interface operating voltage 22.5... 31.6 V DC Max. total current consumption 45 ma 17

AS-Interface / extended addressing mode possible AS-i profile version 2.1 / no S-7.B.E Valid AS-Interface addresses 1...31 AS-i certificate 96101 AS-Interface inputs Door monitoring contact SK Solenoid monitoring contact ÜK AS-Interface outputs D0 D1 D2 AS-Interface LED Power D0, D1 D2, D3 interlocking solenoid, 1 = solenoid energised LED red, 1 = LED on LED green, 1 = LED on green, AS-Interface voltage applied AS-Interface LED Fault red, offline phase or address "0" Reliability values to EN ISO 13849-1 B10 d 5 x 10 6 13 Terms and abbreviations PL Performance level Capability of safety-related parts to perform a safety function under predictable conditions to fulfil the expected risk reduction. B10d Number of cycles, up to 10% of the components with dangerous failure. 18

14 Data bit table 1 2 3 1: Safety guard closed and locked 2: Safety guard closed and not locked 3: Safety guard open Programming Dual channel conditionally dependent Status D0, D1 D2, D3 Monitor diagnostics Safety guard closed and locked Safety guard closed and not locked Invalid status (safety guard open, guard locking active) Code sequence Half sequence 00 Half sequence Green 00 Yellow flashing Flashing red (monitoring of the invalid status) Safety guard open 00 00 Red Address 0 or communication disturbed Grey 19

Programming Dual channel independent Status D0, D1 D2, D3 Monitor diagnostics Safety guard closed and locked Safety guard closed and not locked Invalid status (safety guard open, guard locking active) Code sequence Half sequence 00 Half sequence Green 00 Red Red Safety guard open 00 00 Red Address 0 or communication disturbed Grey 20

Programming Dual channel dependent Synchronisation time infinite Status D0, D1 D2, D3 Monitor diagnostics Safety guard closed and locked Safety guard closed and not locked Invalid status (safety guard open, guard locking active) Code sequence Half sequence 00 Half sequence Green if safety guard was open before or flashing yellow after start-up, if only guard locking was open. 00 Flashing yellow, if safety guard was closed before. Red, if safety guard was open before. Flashing yellow, if safety guard was closed before. Red, if safety guard was open before. Safety guard open 00 00 Red Address 0 or communication disturbed Grey 21

15 Standards and approvals 15.1 Directives and standards The following standards and directives have been applied: Machinery Directive 2006/42/EC EN ISO 13849-1: 2016 EN 62026-2: 2013 EN 60947-5-1: 2004/: 2009 EN 60947-5-1: 2004/: 2009 - Annex K EN 14119: 2013 15.2 Approvals EU declaration of conformity UL (culus) AS-i certificate 22

23