FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

Similar documents
TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

BACKUP BATTERY INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Fire Escape Lighting Solutions. LED Emergency Back up Emergency Lights & Exit Signs Speciality Products

CDL8 LED Architectural

LED HIGH BAY LINEAR HL SERIES

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

S R 8 Circular LED Engine Product Specification

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Corporate Overview. July Fulham Co. Inc.

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Dimensions (111mm) (111mm) 3 (76mm)

SDL4 LED Strip Diffused Lens

LED Emergency Battery Backup

BAS SDL8' LED Strip Diffused Lens

FET22 (2x2) 25W & 40W Series

Alliance 4 - ALI4 LED 4 Linear High Bay

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

LED FLAT PANEL EDGE LIT MLFP SERIES G2

For more information, please visit 3-form.com or call

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

Emergency Lighting. Product Guide LED. The right source for the. right light

Project Name. Date. Cat. Number. Type

INSTALLATION INSTRUCTIONS

FPLHB - Fidelux Premier Linear Highbay

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

LED HIGH BAY LINEAR ECO SERIES

BAS SFP22 Edge-lit LED Panel

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Product Specifications

INSTALLATION INSTRUCTIONS

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

HIGH LUMINOUS EFFICIENCY

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

lumenalpha downlight Specification Sheet

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

DIMMING 0-10V Continuous

DHL-LP-LED Low Profile LED Linear High/Low Bay

LED RETROFIT CONVERSION KITS

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

But act fast: your order must be received by December 21st and ship by December 28th. Order quantity limited to supply in stock.

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Housing. Mounting EPA. Warranty. Listing

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

SPECIFICATION SHEET 24VDC 12VDC. Dimmer + Driver SPEC SHEET 1 OF 5 OVERVIEW FEATURES & BENEFITS COLOURS AND FINISHES APPROVED 24V LED FIXTURES

Lumination LED Luminaires

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Lumination LED Luminaires

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

LED Linear Design Highlights

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

LUXCOMFO TM LED Flood Light Datasheet

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

HIGH BAY APPLICATIONS

ArcLine Recessed LED luminaire

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

PRODUCT DATA SHEET LIGHTING PRODUCTS

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Bdl60u Fluorescent Emergency Ballast

Evolve LED Garage Light

SECTION INTERIOR LIGHTING

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Catalog Number. Notes

EcoSystem H-Series Ballasts

Project Name. Date. Cat. Number. Type

TROFFER RETROFIT KIT (TRK)

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

SPECIFICATIONS Compliance & Regulatory Approvals DIMMER MODELS TRIM PLATES (SOLD SEPARATELY) SYSTEM DIAGRAM. Input. Output. Environmental Requirements

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

KM300 Carbon Monoxide Detection System Installation Manual

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

LHBXD LED Linear High Bay

Project. Comments. Prepared by

RLN Recessed LED luminaire

Transcription:

LED Driver with integrated emergency backup Universal Voltage: 120-277V ~, 50/60Hz Output Wattage: 40W Max. Output Current: 250-1400mA Linear Case with side leads Output voltage range of 11-55V This Driver Will Operate The Following LED Modules: Any LED module designed to accept input voltage range of 11-55VDC and can operate up to current of 250-1400mA. General Specifications Input Voltage Input Current Input Power 120-277VAC, 50/60Hz 0.43A @ 120VAC 54W Power Factor >0.9 THD <20% Standby Input Power <0.85W Driver Type Constant Current Output Current 250-1400mA [ TPSB 100 ( Program Box ) ] ; Record New Setting On 1"x0.5" Label Output Voltage Range 11-28VDC ( 250-1400mA ), 11-40VDC ( 250-1000mA ), 11-55VDC ( 250-730mA ) Output Power 40W Max. 5W or 10W Initial @ Emergency Mode ( Min. 180 Minutes Runtime @ 5W Setting, Min. 90Minutes Runtime @ 10W Setting ) Number of Output Channels 1 Channel Dimming Controller Type / Dimming Range 0-10V / 100% - 1%,0% / Custom Dimming Curve / Dimmed To Off RFI/EMI FCC Part 15A Non-Consumer, EN55015 Output Type LED Class 2 Battery Type 6.4VDC (Part# FHSBATL2-3.2) Battery Capacity Available 3200mAh Battery Recharge Time 12 Hours Max. Case Temperature 62 C(143.6 F) Ambient Operating Temperature Range 0 C to 50 C(32 F to 122 F) Sound Rating A Input Surge Protection Line-Neutral 3kV, Line & Neutral-Gound 6kV, Ring Wave ANSI/IEEEC62.41 Protections Input Current Protection Output Open Circuit Protection Overload Protection Over Temperature Protection Service Life 50,000 hours Approvals / Class RoHS, culus LISTED, CE, CEC, Dry or Damp Locations 3.32"[84.45mm] 0.79"[20mm] Tc Case Tolerance=±0.02" Page1of6 2017-735-1 Rev A

Important Safety Instructions When using electrical equipment and this lighting device basic safety precaution should be followed at all times including but not limited to the following: PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY IMPORTANT: An un-switched AC power source of 120VAC to 277VAC is required for the yellow/black and white leads. IMPORTANT: A switched or un-switched AC power source of 120VAC to 277VAC is acceptable for the black lead only. This device is designed for use in fixtures listed for dry and damp locations. CAUTION: Make sure all electrical connections conform to the National Electrical Code and all applicable local regulations. CAUTION: Do not let power supply cords touch hot surfaces. CAUTION: Do not mount near gas or electric heaters. CAUTION: Do not use this emergency driver with accessory equipment other than recommended by manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed by qualified service personnel. CAUTION: Do not use this emergency driver for other than intended use. CAUTION: Battery is rechargeable type and must be recycled or disposed of properly. CAUTION: Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly, installation or servicing of emergency driver. Additionally ensure that the battery is disconnected (Battery Switch set to OFF). TESTING SYSTEM: The emergency battery requires a minimum charge time of one (1) hour before testing the circuit. A minimum of twelve (12) hours is required for a full charge. RATED EMERGENCY OPERATION: Ninety (90) minutes for the 10W load or one hundred eighty (180) minutes for the 5W load. The 10W or 5W option is determined by the position of Dip Switch 1 (Emergency Power Selection Switch). Fulham Head Quarters: Fulham Co., Inc 12705 South Van Ness Ave. Hawthorne, CA 90250 Manufacturer: North China Fulham Electronic Co. Ltd. No. 9 Xingchang Road, Nanshao Zhen Changping Science Park, Beijing, P.R. China SAVE THESE INSTRUCTIONS Page2of6 2017-735-2 Rev A

NOTE:This driver has six mounting holes, three on each side Either four round holes or two semi-round holes are need for mounting. A Mounting the LED driver Switched or Un-Switched Line BLK( L ) WHT(COMMON) YEL/BLK( L ) Un-Switched Line FHSBATL2-3.2 FHSAC1-UNV-40L LED OUTPUT CHANNEL PURPLE( + ) GRAY( - ) LED OUTPUT LEAD NTC INPUT LEAD DIMMING 0-10V LED MODULE WITH NTC (NTC OPTIONAL) LED MODULE TEST SWITCH / LED INDICATOR Ø Case Length Width Height Dimensions 9.50"[241.4mm] 2.4"[61.0mm] 1.34"[34.0mm] NOTE: 1.The driver must be grounded. 2.Once assembly, installation or servicing is complete, set the BATTERY SWITCH to the ON position. INPUT SIDE BLACK WHITE YEL/BLK OUTPUT SIDE LED OUTPUT TEST LEAD PURPLE GRAY LENGTH 16"[406.4mm] LENGTH 8"[203.2mm] 8"[203.2mm] ON 1 2 RIGHT VIEW OFF DIP SWITCHES Dip Switch 1 - Emergency Power Selection Switch: 5W or 10W(10W @ ON) Dip Switch 2 - Self-Diagnostic Switch: Effective @ ON ON BATTERY SWITCH B Wiring diagram Page3of6 2017-735-3 Rev A

BATTERY REPLACEMENT/SERVICING INSTRUCTIONS Warning: Disconnect power when servicing fixture. Unscrew the nut Remove battery cover and pull out wiring Disconnect the connector STEP 1: Remove the battery cover Take out the battery Place a piece of double adhesive tape on the bottom of the new battery(recommended model 3M:DT542800081 ) Place the new battery inside the battery cover STEP 2: Install new battery Re-connect the battery connector and place all wires back into the battery cover Position the cover and screw on the nut STEP 3: Re-assemble the battery cover C Replacing the battery Completed Assembly SAVE THESE INSTRUCTIONS Exploded View Page4of6 2017-735-4 Rev A

Guideline on calculating emergency illumination level The purpose of this guideline is to identify the illumination level of the LED luminaire when used with Fulham's FHSAC1-UNV-40L LED emergency driver. The path of egress illumination level during emergency operation is determined by types of luminaires, Luminaire Efficacy, Luminaire Mounting Height, Emergency Power and some other effects in real application. Step 1: Select an LED Luminaire, and make sure the LED light source is electrically compatible with Fulham's LED emergency driver. Get the Light Distribution data (usually an.ies file) and Rated Efficacy data (lumen per watt) from luminaire supplier. If the luminaire is DesignLights ConsortiumTM (DLC) compliant, you can also get the efficacy information from DLC website. - Open DLC Qualified Product List(QPL) database search page: https://www.designlights.org/search/ - Searching keywords by model, brand name or manufacturer for the luminaire used. - Find the Efficacy data listed on website or calculated by dividing Light output by Wattage, the efficacy value should be shown in lumen per watt (lm/w). If the luminaire is ENERGY STAR compliant, you can also get the luminaire efficacy information from ENERGY STAR website. - Open ENERGY STAR certified Light Fixtures database search page: https://www.energystar.gov/productfinder/product/certified-light-fixtures/results - Searching keywords by model, brand name or manufacturer for the luminaire used. - Find the Energy Efficiency data listed on website. If it is showed as Measured at the Source, please contact with luminaire supplier for additional light loss for this light source inside the fixture. The value should be shown in lumen per watt (lm/w). Step 2: Determine the Emergency Power and calculate the Emergency Light Output. FHSAC1-UNV-40L is programmable output; setting a proper Emergency Power is vital to achieve desired illumination. Emergency Light Output is equal to the Emergency Power multiply by luminaire efficacy. For example, if the luminaire is 120lm/W and in 3W emergency operation, the total Emergency Light Output is 120lm/W * 3W = 360lm. Step 3: Use industry lighting design software to calculate the illumination level according to the luminaire layout in room, luminaire mounting height, the original.ies file and Emergency Light Output calculated above. If the illumination level cannot meet life safety codes, go back to Step2 to use a higher Emergency Power or go back to Step1 to select a higher efficacy luminaire or use more luminaires in the room. Fulham's FHSAC1-UNV-40L LED emergency driver is compliant with UL 924 standard, according to UL test data, Table 1 and Table 2 below give basic indication to determine the min. Emergency Power and Luminaire Max. Mounting Height for 1 foot-candle illumination based on a single luminaire with typical Lambertian distribution. It is the light designer/ construction contractor's responsibility to validate the real illumination level on site, to assure the emergency light illumination level is in accordance with the requirement of Federal, state and local municipal codes. It may diff to the theoretical calculation or simulation on computer. Table 1. Min. EM Power for 1fc @ 10ft vs. Luminaire Efficacy Table 2. Max. Mounting Height vs. Luminaire Efficacy Luminaire Efficacy Min. EM Power to achieve Luminaire Efficacy Max. Mounting Height for 1fc (lm/w) 1 fc @ 10ft Mounting Height (lm/w) EM 5W EM 10W 80 5.0 W 80 10.1 ft 13.9 ft 100 11.2 ft 15.4 ft 120 12.1 ft 16.8 ft 140 13.0 ft 18.1 ft 160 13.9 ft 19.3 ft 180 14.6 ft 20.4 ft Page5of6 2017-735-5 Rev A

SELF DIAGNOSTIC INSTRUCTIONS / OPERATION: If Dip Switch 2 (Self-Diagnostic Switch) is set to the OFF position: The self diagnostic feature is disable. A functionality test shall be manually conducted every thirty(30) days to ensure the emergency LED light source illuminates as intended. A full discharge test shall be conducted once a year; the LED light source shall illuminate for a minimum of ninety (90) minutes for the 10W load (Dip Switch 1 is set to the ON position) or one hundred eighty (180) minutes for 5W load (Dip Switch 1 is set to the OFF position). If Dip Switch 2 (Self-Diagnostic Switch) is set to the ON position: The self diagnostic feature is enable.the emergency LED driver will conduct a self check for thirty (30) seconds every thirty (30) days; and ninety (90) minutes or one hundred eighty (180) minutes self check every 12 months. After every self check the LED indicator light will indicate a status signal. A single self-diagnostic test can be activated by pressing the test switch three (3) times. Refer to Indicators Status Table for details. When user toggle the Dip Switch, the LED indicator on Switch button would flash 3 times, 2.5S ON/0.5S OFF for Enabled, while 0.5S ON/2.5S OFF for Disabled. TEST SWITCH INDICATOR STATUS: LED Indicators Status Solid Green Slow Flashing Red, 4s on/1s off Flashing Red, 1s on/1s off Flashing Green, 1s on/1s off Fast Flashing Red, 0.1s on/0.1s off Very Slow Flashing Red, 4s on/4s off None. Both LEDs OFF Green/Red alternative flashing, 1s green/1s red. EM Driver Status/Mode System OK/AC OK(Self-diagnostic Enabled or Disabled). Battery not detected, check battery switch or connection. Battery Failure, replace battery. Self-Diagnostic test underway. Abnormal driver performance, replace driver. Over temperature. Normal working in EM mode. No load or output over voltage protection triggered. TEST SWITCH OPERATIONS: 1. EM Test: Press and hold test button (>1s)to enter EM mode for testing in normal AC powered. 2. Manual Self-Diagnostic(When Self-Diagnostic Enabled - Dip Switch 1 set to the ON position): After charging twelve (12) hours or battery fully charged, quickly press the test button three(3) times within three(3) seconds to force the controller to enter a Self-Diagnostic cycle. To quit the self-diagnostic cycle after engaged press and hold the test button for ten(10) seconds. Programming: This driver can be programmed using Fulham SmartSet TPSB-100(E). Programming features include the following: * Output Current : 250-1400mA * Dimming Curve * LED NTC Thermal Protection Page6of6 2017-735-6 Rev A