WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

Similar documents
Ocelot Fan Coil Units

Panther Fan Coil Units

Installation, Operation & Maintenance Instructions Document Ref:

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref:

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

Panther Fan Coil Unit

Efficient Cooling and Heating. Flexibility Is The Key

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

SERIES BM. Concealed Fan Convector

S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

H Y D R O C O U R S E T R E N C H H E A T I N G

XB-EFA-8L-BK & XB-EFA-8R-BK

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Aegean Range. A new range of fan coils for heating and cooling commercial applications

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Halton CHB Active chilled beam with boost function for bulkhead installation

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

AP-EH500-L/RQA9837. Installation Guide

Installation, operation and Maintenance Manual

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Lo-Carbon Quadra Centrifugal Fan

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Installation and Wiring Instructions

Optimax Refrigerated Retail Merchandisers

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

Lo-Carbon Quadra SELV

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

FAN COIL UNITS IMPORTANT NOTE ABOUT EC FAN SPEED CONTROL

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Optimax Refrigerated Retail Merchandisers

Lo-Carbon T-series Window & Roof Models

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Antarctic-Unit Cooler/Air Cooler

Centrif Duo & Centrif Duo Plus

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Installation and Maintenance

Installation and Servicing Instructions. Alpha GasSaver GS-2

Quantum Waterside Fan Coil Specification 2. Mounting 3. Pipework Connections 3. Duct Connections 3. Electrical Connections 4.

Metropolitan high output natural and powered trench heaters

Technical documentation Fan coil unit

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Quantum Airside Fan Coil Specification 2. Mounting 3. Pipework Connections 3. Duct Connections 3. Electrical Connections 4.

Installation and Operating Manual Drying Cabinet

TOSHIBA AIR CONDITIONING

Installation and Maintenance

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

Installation and Servicing Instructions. Alpha GasSaver GS-1

WXC R134a. Nominal Cooling Capacity from 224 to 692kW

PERFORMANCE SHOWER PRODUCTS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation and Maintenance

HEAVY DUTY BRASS SHOWER PUMPS

Halton Rex 600 Basic R6B - Active chilled beam

This label warns for risk of electrical shock when failing to observe.

Ceiling Concealed Fan-Coil Unit

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

WHHR Midi & Midi Lite

ELECTRIC WATER BOILER

Actionair Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications

SERVICING AND BREAKDOWN...

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

SURFACE WARM CEILING HEATERS

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Lo-Carbon Quadra Centrifugal Fan

CARIBBEAN REFRIGERATED TOPPERS

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

PANEL HEATER OPERATING INSTRUCTIONS. For Model: CELEPANELD

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

OPERATING AND MAINTENANCE MANUAL

General Care and Safety Guide

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Halton Rex for Vario R6O - Variable air volume chilled beam

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

TopVent Design Handbook

Transcription:

Puma Fan Coil Units Instructions.. Installation, Operation and Maintenance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 PDSPDS-12001200-F-02440244-02 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document Part No: 132-000-001 (UK) www.dunham-bush.co.uk Date : January 2013 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY WIRING WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. INTRODUCTION This booklet provides guidance to identify, handle, install and commission Dunham-Bush Puma fan coil units as well as guidance for operation and maintenance. DESCRIPTION Dunham-Bush Puma fan coil unit comprises a galvanised sheet steel casing with access to each part of the unit; fan/motor assemblies, air filter, dual purpose heating/cooling coil and electrical connections box, via panels retained using either quarter-turn push fit quick release fasteners or self-tapping screws. Fan coil units are designed for up to nine fan speed operation, with fan control provided by means of an autotransformer with fan speed switches These instructions are to be read in conjunction with the wiring diagram supplied suppli ed with the unit. unit. The instructions apply to units from the standard range only. Please study the instructions carefully before commencing any installation work. IDENTIFICATION The fan coil unit serial number, description, figure number (size) are displayed on a label found on the fan coil discharge plenum. If specified, a stencil reference may also be marked on the discharge plenum for onsite identification. Valves and actuators (coil connections) Discharge plenum access panel Condensate drain connection Diagram: STANDARD RANGE MODELS & SIZES Puma is a vertical basic chassis fan coil unit, available in seven sizes, Figures 1 to 7 inclusive. Each size is supplied complete with a rectangular discharge plenum Discharge spigot Fan/motor access panel Fan speed and on/off switches Electrical connection box Puma Fig 3 LH connections with rectangular discharge plenum (bottom inlet shown)

235.0 155.0 FIGURE DIMENSION 'A' DIMENSION 'B' 01 695.0 655.0 02 1095.0 1055.0 03 1095.0 1055.0 04 1495.0 1455.0 05 1495.0 1455.0 06 1895.0 1855.0 07 1895.0 1855.0 DIMENSION 'C' 550.0 950.0 950.0 1350.0 1350.0 1750.0 1750.0 DIMENSION 'D' 625.0 1025.0 1025.0 1425.0 1425.0 1825.0 1825.0 55.0 DIMENSION 'C' 550.0 500.0 430.0 50.0 MINIMUM DISTANCE FOR BOTTOM AIR INTAKE 150.0 19.5 DIMENSION 'D' DIMENSION 'B' 157.0 DIMENSION 'A' 64.0 LH UNIT SHOWN RH OPPOSITE FIGURE 01 SHOWN CONTROL BOX FULLY OPEN 250.7 Diagram 2: Range of standard sizes with rectangular discharge plenum ACCESSORIES Standard controls Dunham-Bush Puma fan coil units are available with accessories for remote control. These include remote setpoint adjusters, remote room air sensors and remote fan speed controllers. Refer to the wiring diagram included with the fan coil unit for details on installation and wiring of remote controls. Discharge/Inlet Configuration The standard discharge configuration comprises a rectangular discharge plenum fitted with a single upward facing rectangular spigot, the size of which is dependent upon the model number. The spigot can also be fitted facing forward and can be repositioned on site without the need for any additional or replacement components. The standard inlet configuration comprises a downward facing rectangular aperture, into which the filter is located. The filter can also be fitted facing forward and can be repositioned on site without the need for any additional or replacement components. CONSTRUCTION Delivery The purchaser is responsible for off-loading, and must examine the fan coil units promptly upon receipt. Any claims for damage will only be accepted if, at the time of delivery, the consignment note is endorsed with the details and counter signed by the transport driver. Each fan coil unit is marked to show the model, figure number, serial number and stencil reference if specified. Handling and Storage Fan coil units are individually packed and two/three persons can usually handle the heaviest unit. When a significant quantity of fan coils is delivered, they may be palletised and shrink-wrapped, so a fork-lift or similar will be required for lifting. The fan coil unit must not be dropped or suffer impact in any circumstances and should never be lifted or handled by their coil connections. Fan coil units should be stored in clean, dry conditions. Any packaging should not be removed until the fan coil unit is required for installation. Packaging should only be removed if damage is suspected at the time of delivery. Page 2 of 12

WARNING: Puma fan coil units are designed with minimal sharp edges on the chassis. Some internal components on the fan coil may have sharp edges. Care must be taken when handling the product; protective gloves should be worn. FIGURE 1 2 3 4 5 6 7 Dry mass of basic unit with discharge spigot plenum only (kg) 29 40 44 56 61 71 75 Table 1: Approximate masses of Puma fan coil units INSTALLATION General Before removing any packaging, check the identity of the fan coil unit against the stencil reference marked on the access panel. Packaging should be retained to protect the fan coil unit from damage by other works after installation. Fitting 1. Prepare wall fixings to accept the fan coil unit. M8 bolts, complete with appropriate washers, are suitable. Refer to Diagram 2 for positions of fixings. 2. Suspend the fan coil unit and ensure it is level in both directions. Use a spirit level on the casing, not the drip tray (The drip tray is graded to ensure drainage of condensate). 3. Connect ductwork to the fan coil unit. Flexible duct connections are recommended where sheet metal ductwork is used. Do not suspend any ductwork from the fan coil unit alone. Refer to Diagram 2 for spigot position. 4. Connect pipework as shown in Diagram 4. 5. Connect a suitable drain to the drip tray. 6. Connect electrical supply and control accessories as shown in wiring diagrams enclosed with the fan coil unit. 7. After filling the hot and chilled water systems, check for leaks (refer to Commissioning). 8. Ensure condensate pump is installed in accordance with manufacturers requirements and see diagrams 3a and 3b below. Pipework Connections 1. The coil is a dual purpose coil with OD15mm copper tube tails at 40mm centres between flow and return connections. Always observe the correct direction of flow. (see diagram 4) 2. Local isolating and regulating valves are recommended, as well as strainers to filter out foreign matter in the water. 3. The installer must provide any fittings to connect pipework to fitted 2 or 4 port valves. 4. The drip tray has a OD22mm tube connection, suitable for a compression fitting or similar, to be supplied by the installer. Electrical connections and controls 1. The electrical connections box is located on the side of the fan coil unit, and incorporates a hinged access door, fastened with a self-tapping screw. 2. Connect a 230V/1ph/50Hz supply to the flying lead fitted to the electrical connections box. 3. Fit any remote accessories in their appropriate locations and connect terminal block inside the electrical connections box. Refer to the wiring diagram enclosed with the fan coil unit for specific wiring details. 1. All wiring should comply with IEE regulations (BS 7671) and local bye-laws. Diagram 3a Diagram 3b Page 3 of 12

Diagram 4: Pipework connections, as viewed on header/connection end of coil Diagram 5: Electrical connections box Diagram 6: Valves, actuators and drip tray Page 4 of 12

Diagram 7: Fan/motor access panel removal (bottom inlet shown) COMMISSIONING 1. Ensure that the fan coil unit is clean, and the filter especially is clean and free from dust. Check the fastness of all access panels and ductwork connections. 2. Check that all electrical connections are correct and comply with BS7671 and local bye-laws. Refer to the wiring diagram supplied with the fan coil unit 3. Check the coil connections and drip tray connections for leaks. Refer to Table 3 for coil test and working pressures. 4. Purge air from both heating and cooling sections of the coil using the manual air vents fitted. 5. Balance the water flow rate through both hot and chilled water systems following accepted practice to achieve the specified flow rates. 6. On AC motor units, there are two fan speedswitches - one to give three main speeds, and theother to provide a fineadjust to each speed.set the switches to the specified design settings,as highlighted on the label fixed the plenum accesspanel. (Refer to diagram 10 for fan switch settings) 7. On EC motor units, adjust potentometer to ensure air volume to design specification. If using a BMS controller with a 0-10V output, adjust the fan via the remote interface to ensure air volume and external static resistance are both to design specification. 8. If fitted, set any remote switches and/or controls to the specified settings. Check the operation of controls in accordance with control manufacturer s instructions. 9. Check the operation of any remote fan speed or remote thermal controls. 10. If supplied/fitted, check the operation of the condensate pump by pouring a small quantity of water into the drip tray; ensure the pump clears any water and operates any alarms etc. 11. Leave this document and the wiring diagrams with the end user. For further information on any fan coil unit - contact Dunham-Bush, quoting the serial number on the label on the access panel. Page 5 of 12

Size Cooling coil valve Kv Heating coil valve Kv Figure 1 1.6 0.6 Figure 2 & 3 1.6 0.6 Figure 4 & 5 1.6 1.0 Figure 6 & 7 1.6 1.0 Table 2-4 port valves; recommended Kv values to match coils Coil Section Maximum test pressure Recommended working pressure Cooling 20 barg 7 barg Heating 20 barg 7 barg Table 3 - Maximum test and working pressures WARNING Air vents should not be operated during pressure tests. Recommended working pressure is limited to 7 barg to ensure safe operation of manual air vents. Size Cooling section content Heating section content Figure 1 1.70 0.20 Figure 2 & 3 2.55 0.28 Figure 4 & 5 3.68 0.40 Figure 6 & 7 4.53 0.51 Table 4 - Water content of cooling and heating sections of coil Diagram 8: Fan switch speed settings; also shown as label affixed to fan coil unit (AC motor units only) Page 6 of 12

Diagram 9: Typical wiring diagram Basic AC motor speed Control Refer to wiring diagram supplied with unit. Page 7 of 12

Diagram 10: Typical wiring diagram Basic EC motor speed Control - Refer to wiring diagram supplied with unit Page 8 of 12

OPERATION Puma fan coil units provide cooling and heating of air when used in conjunction with chilled water and/or low temperature hot water systems. They are designed for either high level wall mounting or low level floor mounting, connected to a discharge grille. When running, the fan draws air from the room and/or primary source, through an inlet filter. The air is then discharged over the heating/cooling coil, through the spigot, along ductwork and through the grille to the room space.. Alternative options include chilled water cooling only, either top or front discharge and either bottom or front inlet. Fans normally run continuously, with control provided via an automatic control system varying the flow rates of chilled water and hot water through the coil (waterside control). Depending upon the particular type of controls fitted, user control is provided by fan speed switches and/or temperature control. Fan speed switch settings are shown on a label affixed to the discharge plenum. CONTROLS Puma fan coil units are fitted with a waterside control system, which typically comprises the following elements :- Fitted fan on/off Fan speed change switches (AC motor units) Fan speed potentiometer (EC motor units) Fan coil controller Return air sensor Valve actuators (Two or four port valves) Additional optional accessories include :- Remote room air sensor Remote setpoint adjuster Remote fan on/off and speed switches Fitted relays for master/slave or BMS control CLEANING Cleaning and maintenance must be carried out by competent persons Inspection The frequency of cleaning and inspection depends upon the conditions in which the fan coil unit operates. Initially, it is suggested that the air filter and drip tray are inspected after 6-8 weeks normal operation. Access There are two access panels discharge plenum and fan/motor access. All access panels can be opened by either removing self-tapping screws or turning quarter-turn fasteners. Cleaning 1. Air filters can be cleaned by tapping out excess dust and washing in warm water (up to 40 C), using detergent if necessary. The filter must be rinsed and allow to dry naturally before replacing. Do not use a vacuum cleaner, as it can damage the filter media. Filters should be replaced after approximately 20 washes. 2. The drip tray can be cleaned with warm, soapy water. Ensure the drip tray drains freely. 3. If a condensate pump is fitted, check any sensors are clean and wiped dry. Test the operation of the pump by pouring clean water into the drip tray. Because the air filter retains most of the dusty particles, it will only be necessary to clean the fans, motors and coil annually. An industrial vacuum cleaner can be used to clean the inside of the fan coil, in particular the coil and fans, with the air being sucked through the coil in the opposite direction to normal air flow. All accessible surfaces can be cleaned with a cloth. Additional optional accessories include :- Remote room air sensor Remote setpoint adjuster Remote fan on/off and speed switches Fitted relays for master/slave or BMS control. Dunham-Bush also fit non-standard controls supplied b yothers; refer to the wiring diagram supplied with the unit. Additional optional accessories include :- Remote room air sensor Remote setpoint adjuster Remote fan on/off and speed switches Fitted relays for master/slave or BMS control Page 9 of 12

MAINTENANCE 1. Purge any air from both cooling and heating sections of the coil using the manual air vents (using a suitable key). 2. The fan motor has sealed for life bearings which do not require any maintenance, other than visual inspection 3. The electrical connections box incorporates a 5A fuse. 4. Refer to page 2. Each fan coil unit is supplied with a wiring diagram applicable for the particular controls and accessories. Further copies are available on request. Please quote the serial number on the label on the main access panel. 5. Check the operation of all controls by varying their settings to achieve the desired effect on the fan. WARNING 1. Prior to undertaking any cleaning or maintenance, ensure that the fan coil unit and any controls are disconnected from the electrical supply at the local isolator. 2. Some internal components onents may have sharp edges. Care must be taken when working on the fan coil unit, and protective gloves should be worn. Page 10 of 12

Page 11 of 12

SPARES/SERVICE PLEASE WRITE THE DETAILS OF THE UNIT HERE. These details will be required when ordering spares for you Dunham-Bush Puma Fancoil Unit UNIT TYPE AND MODEL INFORMATION SERIAL NUMBER DATE OF INSTALLATION Spare parts/service Please contact our office, contact information shown below. Manufacturer reserves the right to change any product specification without notice. Dunham-Bush Ltd, Downley Road, Havant, Hants, PO9 2JD Sales and Technical Support Spare Parts and Service Tel: 023 9247 7700 Fax: 023 9245 3601 Tel: 023 9247 7700 Fax: 023 9245 3601 Email: infouk@dunham-bush.com Email: spares@dunham-bush.com Page 12 of 12