PRM470 Portable Monitor Operation and Service Manual D00092 June 02, 2016 Rev. 2

Similar documents
TPM903B P/N D00089 Operation and Service Manual Rev. 2. TPM903B Transportable Portal Monitor Operation and Service Manual D00089 June 02, 2016 Rev.

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Alarm Tone Generator Model AG17

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Environmental Monitoring SmartSlot Card

Mini rad-d User's Manual - February 22, 2010

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

OVEN INDUSTRIES, INC.

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

Series: MBC1-TC Mini Benchtop Temperature Controller

User's Guide. Pinless Moisture Meter. Model MO257

High Temperature InfraRed Thermometer with Laser Pointer

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Owner s Manual & Safety Instructions

Troubleshooting Thermo Scientific LevelPRO Gauges

PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER РМ1703МО-1 OPERATION MANUAL

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Operator's Manual. LIGHTNING 2 Laser Detector

UNC100 Integra Manual

JOVY SYSTEMS RE-7500 User Manual Rev Index

Victoreen Primalert 35 Area Radiation Monitor

Environmental Monitoring Card

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

RTD TEMPERATURE SENSING SYSTEM

RK-05 Combustible Gas Transmitter Operator s Manual

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

SCAN200E USER S MANUAL

Figure 1. Figure 2. See notes 1 and 2 below.

IMpORTANT SAFETy INSTRUcTIONS

Remote Relay Module (RRM)

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Protégé Eclipse LED Keypad User Manual PRT-KLES

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

SENSIT HXG-2d Combustible Gas Detector

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

IntelliDoX Operator Manual

About D-tect Systems. Personal Radiation Detector General Description of Operation. Founded in 2001 as a division of Mission Research

IMR IX176 Portable Gas Detector User Manual

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Dual Laser InfraRed (IR) Thermometer

Operations Manual TS400. Test Station for G450/G460 Gas Detector

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

Portable Survey Instruments NISP-RP-01

MGC Dock User s Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Installation Instructions

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

RK Combustible Gas Transmitter Operator s Manual

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

SUTTON 52 CEILING FAN

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

100 Ft. LASER DISTANCE METER

Operations Manual TS400. Test Station for G450/G460 Gas Detector

RK Carbon Monoxide Transmitter Operator s Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Model Number Structure

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

D-TEK Select. Refrigerant Leak Detector

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

Beacon 800 Gas Monitor Operator s Manual

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Digital Heat Block User Manual

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Installation and Operation Manual

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

MGC Dock User s Manual

Revolutionary Science RS-IF-202

COMBUSTIBLE GAS LEAK DETECTOR PEN

Operators Manual The Black Pearl

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

RK CO 2 Transmitter Operator s Manual

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

status AW1 Plus WiFi Alarm System User Manual

Specification for On-Line UPS Battery Monitoring and Data Management System

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

RK Carbon Monoxide Transmitter Operator s Manual

LAUNDRY MONITORING SYSTEM Model # LIM-64S

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Dashboard for Windows V1.1.0

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Fiber Optic Cable Fence Disturbance Sensor

RK Transmitter Technical Notice

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Transcription:

PRM470 P/N D00092 PRM470 Portable Monitor D00092 June 02, 2016

PRM470 P/N D00092 Foreword Thank You for choosing a Rapiscan Detection product. This manual is intended for the installation and normal daily use of the equipment. In addition to these instructions, local laws and regulations, and requirements by authorities shall be observed. The user should read this manual and understand its contents before the installation or use of the equipment. Copyright Notice The owner or authorized user of a valid copy of the products covered by this manual may reproduce this publication only for the purpose of learning to use such product. No part of this publication may be reproduced or transmitted for any other purpose, such as selling copies of this publication or providing paid-for support services. Rapiscan Systems. All rights reserved. Content of this Manual We have made an effort to ensure that the information in this manual is accurate as of the date of publication. However, the product that you have purchased may contain options, upgrades or modifications not covered by this manual. If you have any questions about the content of this manual or the product that you have purchased, please contact Rapiscan Systems Customer Service. No Warranties The provision of this manual to you creates no express or implied warranties of any kind, including, without limitation any warranties with respect to the accuracy, applicability, completeness or fitness of this manual for any particular purpose. Limitation on Liability and Warranty Rapiscan systems will not accept liability for damage or personal injury caused directly or indirectly by either incorrect or poor quality termination of the local main power supply or power cables. Rapiscan Systems is not responsible for damage or injury caused by unauthorized modification, maintenance, operation or tampering with this equipment. Rapiscan Systems will not be liable for any indirect, special, incidental or consequential damage, including loss of profit. Rapiscan Systems disclaims liability for any express or implied warranty of merchantability or fitness of the product for a particular purpose. Any modification or alteration made to the system after purchase by the customer or their agents without written authorization from Rapiscan Systems Service Department Management will void any warranty issued to the customer. Additionally, Rapiscan Systems is not liable for any damage that might be caused by any unapproved changes or modifications.

PRM470 P/N D00092 Revision History Name of Document:, PRM470 Document Number: D00092, Revision 2 Rev. Date Name Comments B 2002-10 Initial draft. C 2005-12 Update 2011-09 CB Update 1 2015-02 CB Updated to Rapiscan 2 2016-06 CB Updated safety, liability, graphics, photos and more

P/N D00092 PRM470 Page 4 Table of Contents 1 IMPORTANT INSTRUCTIONS... 1 1.1 Types of Alert Messages... 2 1.2 Symbols used on Unit and in Manual... 2 2 INTRODUCTION... 3 2.1 Scope and Purpose of Manual... 3 2.2 General Description... 3 2.3 Environmental Conditions... 3 2.4 Specifications... 4 2.5 Serviceability... 4 2.6 Optional Components... 4 2.6.1 Neutron Detector... 4 2.6.2 Headphones... 4 3 PRODUCT CONDITIONS... 5 3.1 Inspection... 5 3.2 Damage Claims... 5 3.3 Storage... 5 3.4 Shipping... 5 3.5 Battery Connections... 5 4 SET-UP AND PROGRAMMING... 6 4.1 Charging... 6 4.2 Set-up... 6 4.3 Programming the Hand-Held... 7 4.4 Default Parameters... 7 4.5 Parameter Details... 8 4.6 Programming From the Front Panel... 9 4.7 Menu Items... 11 4.8 Field Electronic Alignment Procedures... 12 5 OPERATIONAL TEST... 13 5.1 Gamma and Neutron Maintenance... 13 5.2 Component Access... 13 6 GLOSSARY... 14 7 PARTS LISTS... 15 7.1 Spare Parts Ordering Information... 15 8 LIST OF DRAWINGS... 16

P/N D00092 PRM470 Page 1 1 IMPORTANT INSTRUCTIONS Read through this chapter carefully before operating the equipment. Keep this manual so that it is always readily available to the user. The instructions in this manual shall be followed in all situations, when using, or servicing the equipment. Rapiscan Systems cannot be held responsible for any personal or material damage caused by use contradicting the instructions given in this manual. All safety regulations must be observed. A dangerous or unsafe manner of operation may be a health risk. Installation may only be carried out by qualified persons. Before operating or servicing the equipment, make sure that it poses no risk of personal or material damage. Do not operate the equipment unless you are fully trained to do so. The operator must know the use, service, and safety instructions of the equipment, and local safety regulations. Service of Rapiscan products shall be performed only by a Rapiscan Systems qualified service provider or authorized contractor qualified service provider. It is forbidden to operate the equipment when ill, or under the influence of alcohol or drugs. Original PRM470 spare parts should be exclusively used. The enclosure should be cleaned using only a mild soap and water. A dampened cloth should be used to prevent water from dripping into the unit. The end user is responsible for the final calibration of the equipment for the intended application. It is also the end user s responsibility to regularly verify calibration to the desired sensitivity level by using a suitable test object or objects. If there is any reason to suspect that the security level of the equipment may have deteriorated due to incorrect operation or external damage, the equipment should be removed from operation and an authorized service provider should be called in.

P/N D00092 PRM470 Page 2 1.1 Types of Alert Messages WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or equipment damage or generally unsafe practices NOTICE Indicates an important notice to the reader that does not necessarily involve the possibility of personal injury or equipment damage All warnings, cautions, notices and instructions presented in this manual should be read and followed by all personnel who will use or maintain this equipment. Failure to follow all such warnings, cautions, notices and instructions may result in damage to the equipment and/or injury or death to personnel. Such failure may also nullify any warranties provide by the manufacturer. 1.2 Symbols used on Unit and in Manual General Warning Sign This sign is used to alert the user to potential hazards. All safety messages that follow this sign shall be obeyed to avoid possible harm. Recycling Symbol This symbol means that according to local laws and regulations this product should not be disposed of in the household waste but sent for recycling. CE Symbol CE marking on a product is a manufacturer s declaration that the product complies with the essential requirements of the relevant European health, safety and environmental protection legislation. Symbol for Direct Current (DC)

P/N D00092 PRM470 Page 3 2 INTRODUCTION 2.1 Scope and Purpose of Manual This study guide is designed to enable operating and service personnel to properly test, operate, and maintain the Rapiscan Hand-held Gamma/Neutron monitors. Since applications are necessarily site-specific, operation procedures are given in general terms. Service and repair are covered to the board level. Anything more complex than this requires that the instrument or assembly be returned to Rapiscan. 2.2 General Description Rapiscan Hand-held monitors are highly reliable units for the detection of radioactive materials. The PRM470 is designed for both indoor and outdoor use but the unit is not water proof. NOTICE The unit can be used in wet locations but if the unit is to be used in the rain it is suggested that the unit be placed in a plastic bag to prevent water from entering the unit through any of the unit s openings. The PRM470 has been designed to provide continuous use for 12 to 16 hours between charges. The charge time is only 4 hours. To charge the unit, turn off the unit and plug the charger into the side panel charger jack and the charger into an AC outlet. Each hand-held unit contains one gamma detector and can also be outfitted with one 3He tube for neutron measurement. WARNING Operation of this unit in a manner not specified by the manufacturer may decrease or eliminate the unit s ability to detect radioactive materials. 2.3 Environmental Conditions Normal Operation: Temperature rating is 0 C to 40 C. Ambient Relative Humidity: 5% - 95% (non-condensing) Altitude: -200 to 14,000 ft. (-60 to 4,267m) Storage and Transport: Temperature: -40 to 185 F (-40 C to 85 C) Ambient Relative Humidity: 5% - 95% (non-condensing) Altitude: -200 to 50,000 ft. (-60 to 15,000m)

P/N D00092 PRM470 Page 4 2.4 Specifications Gamma Detector: One 3.4" x 2.7" x 1.3" (8.64 x 6.86 x 3.30cm) organic plastic scintillator. Optional Neutron Detector: One 3/4" dia. X 5" length (1.9 X 12.7cm), 4ATM 3He detector Sensitivity: Will detect 10g HEU or 1g 239Pu when tested in accordance with ASTM Standard C 1237* Battery: The unit comes equipped with a 4.8 volt, 2100 mah nickel metal hydride (NiMH) four cell battery pack. The average current draw of the unit is 100mA at 4.8 volts. Charger: Mains input: 100-240V-/0.3A/50-60Hz Output: 4.8-12Vdc/0.8A 2.5 Serviceability Component level part replacement is not practical with this unit. A trained technician can replace the battery pack or possibly a detector but it is recommended that the unit be returned to Rapiscan for repair. Weight: Approximately 2.75lb (1.3kg) Dimensions: 7 7/8"h x 4 3/4"w x 3 5/8"d (20 x 12.07 x 9.21cm) WARNING Opening the PRM470 can expose the service personnel to the following risks: Shock from the high voltage supply Fire if the battery is shorted Heat if the battery is shorted Cuts from components within the enclosure 2.6 Optional Components 2.6.1 Neutron Detector The Rapiscan Model PRM470 Hand-held Monitor comes equipped with a gamma detector as standard equipment. An optional neutron detector can be added to give additional neutron sensitivity. 2.6.2 Headphones Headphones may be used with the PRM470 for areas that may be noisy or for situations where the fact that a unit is alarming is not information to be shared by other persons in the area. Headphones are a user supplied item.

P/N D00092 PRM470 Page 5 3 PRODUCT CONDITIONS The following steps should be followed to ensure that the PRM470 is handled properly. 3.1 Inspection Immediately inspect the instrument for mechanical damage, scratches, dents or other defects. It should be examined for evidence of concealed, as well as external damage. 3.2 Damage Claims If the instrument is damaged in transit or fails to meet specifications upon receipt, notify the carrier and Rapiscan Systems immediately. Shipping cartons, packing materials, waybills and other such documentation should be preserved for the carrier s inspection. Rapiscan will assist in providing replacement or repair of the instrument if necessary. 3.3 Storage If the instrument is to be stored for any length of time, have a trained technician remove and store any batteries separately in a cool place. If batteries are to be stored for any length of time, they should be inspected, and, if necessary, fully charged at least once a month. Care should always be taken to avoid subjecting the instrument to severe mechanical or environmental shock. The instrument should be stored in a dry, temperature controlled location. 3.4 Shipping Before returning the instrument for any reason, notify Rapiscan Systems of the difficulty encountered, giving the model and serial numbers of the equipment. Rapiscan will furnish specific shipping instructions. 3.5 Battery Connections The unit comes with the battery disconnected. Open the unit and plug in the battery. Battery Connector

P/N D00092 PRM470 Page 6 4 SET-UP AND PROGRAMMING To operate the monitor, press the POWER switch. The display will show Rapiscan Systems along with the model number and version number and the audible will sound. Next, the display counts down to zero until the monitor is ready for operation and displaying a new count. At this time the red and blue LEDs will go on and off (if the unit has both gamma and neutron detectors). Do not move the monitor until it has had an opportunity to acquire a background. NOTICE If the instrument is equipped with a neutron detector, give it at least 60 seconds to acquire an initial background. The neutron detectors may see some spurious counts on power up and this will give the instrument time to flush those counts out of the background buffer prior to operation. 4.1 Charging Ensure the unit has been charged before using. NOTICE The charger used on the PRM470 is a smart charger. It is programmed to charge from four to ten nickel metal hydride (NiMH) batteries. If the PRM470 is allowed to operate while it is being charged the charger itself will often stop charging and display that an error has occurred because there is more current being drawn than just the batteries would require. NOTICE There is an inherent risk with NiMH chemistry that overcharging will cause a buildup of hydrogen, causing the cell to rupture. The use of a smart charger prevents the battery pack from being overcharged. 4.2 Set-up The monitor is fully calibrated at the factory. The PRM470 has many user programmable parameters that can be used to optimize it for a wide variety of applications.

P/N D00092 PRM470 Page 7 4.3 Programming the Hand-Held The Rapiscan PRM Comm PC Communications Program can be downloaded from the Rapiscan website www.rapiscansystems.com. The program requires an IBM/PC compatible computer running Microsoft Windows XP, 2000, NT4, 95, or 98. The program allows the operator to examine the system parameters and download data. NOTICE Rapiscan recommends that the PRM470 be shut down prior to connecting or disconnecting the programming computer. Step Action 1 Install the Communication Application Software from the Rapiscan website 2 Use a standard RS232 cable or USB to serial converter cable to connect the PRM-470 to the computer 3 Find the Application on the computer by following this path: start programs TSA Systems PRMCOM PRMCOM 4 When the Application screen comes up you will need to move the cursor to the connect button and left click 5 After a few seconds the computer should connect and the previously stored parameters in the PRM-470 should be displayed 6 If a Data Plot is desired, the TX Data will need to be toggled from OFF to ON 7 If any parameter changes have been made, move the cursor to the SEND PARAMETERS button and left click 8 After a few seconds, data from the PRM-470 should be displayed in the RS232 Data Stream box 9 You can now select the Data Plots tab and view a graph of the data 4.4 Default Parameters The default parameters are as follows: Sigma = 3 (Sigma) Neutron Alarm = 10 (CPS) Background Time = 20 (sec) Low Gamma Alarm = 0 (CPS) Motion Time = 30 (sec) Restrict Setup = OFF Gamma LLD = 0.06 (Volts) Count Mode = Find Gamma ULD = 5.01 Gamma Units = CPS Neut LLD = 1.00 Alarm Pitch = 0 Neut ULD = 5.01 TX_Data = OFF

P/N D00092 PRM470 Page 8 4.5 Parameter Details Sigma - Changing this value will change the sensitivity of the unit. Alarms are calculated by taking the square root of the background and multiplying that value by the Sigma. The resulting value is the number of CPS above background to cause the unit to alarm. As the Sigma value is raised it will take more CPS above background to cause an alarm. Background Time - This value controls the amount of time the unit takes to count down and display a background. Increasing the time will help smooth the data and give a more accurate background count. In most cases the default setting of 5 should be the preferred setting. Motion Time - Adjusting this value changes the amount of time the unit must remain motionless until it switches to background mode. If the value is changed to 0 the unit won t sense motion. The unit will need to be manually put in search or find mode with the panel buttons. Gamma LLD - The Lower Level Discriminator (LLD) is the value for the lower energy window setting for the unit. Raising this value could cause some of the lower energy sources to be missed during a search. Lowering this value can cause false readings caused by noise. This value should be left at the default setting. Gamma ULD - The Upper Level Discriminator (ULD) is the value for the upper energy window setting for the unit. Lowering this value could cause some of the higher energy sources to be missed during a search. This value should be left at the default setting. Neut LLD - Sets the voltage of the neutron channel lower level discriminator Neut ULD - Sets the voltage of the neutron channel upper level discriminator Neutron Alarm - This value is the threshold for a neutron alarm in CPS. Increasing this value will mean that it will take more neutrons to cause the unit to alarm. Low Gamma Alarm - Gamma background CPS that fall below this value will cause a Gamma Low Fault message to be displayed on the unit. Restrict Setup - The default setting for this feature is off. This will allow any user to change the unit s parameters by using the front panel buttons. If you want to prevent parameters from being changed in the field, then the Restrict Setup should be turned ON. Count Mode - Displays the current or previously used search mode. Gamma Units - Changes how the data is being displayed. The selections are Counts per Second (CPS), MilliRem per Hour (mr/hr), and MicroSieverts per Hour (usv/hr). The mr/hr and usv/hr are not energy compensated. Values are estimated. This is not to be used as a survey instrument.

P/N D00092 PRM470 Page 9 Alarm Pitch - Adjusting this parameter causes the pitch of the SEARCH mode audible alarm to change. The FIND mode audible alarm is unaffected by this control. This feature can be useful to someone who has hearing difficulties for a particular range of tones. TX Data - Must be ON for the Application to display received count data and show plots of the data. Parameters can be viewed and changed without needing this ON. To conserve the battery, this feature should be turned OFF after you have finished observing the data or plots. 4.6 Programming From the Front Panel Front Panel switches (see photos on next page) POWER - turns the unit on/off MODE - Change mode from background to fast count. Hold down to enter menu. When in the menu, MODE acts as an ENTER button. LIGHT - Turns the back-light on/off. When in the menu, LIGHT acts as an up arrow. S/F - Search/Find - toggles fast count between search and find modes. When in the menu, S/F acts as a down arrow. Internal motion switch - An internal motion switch senses when the unit is picked up or set down. If Motion Timeout is enabled (any value other than zero), the unit will enter background mode whenever the unit has set motionless for a user defined amount of time (see Motion Timeout below). If enabled, the unit will automatically change modes from background to search or find when the unit is picked up. Menu - To enter the menu, press and hold MODE. "SETUP MODE" will be displayed along with a menu item. To change the value of a menu item, press MODE. "Adjust Value" will be displayed along with the current value of the menu item. Use the "LIGHT (up)" and "S/F (down)" buttons to increase or decrease the value. When the desired value is displayed, press MODE to accept. To view additional menu items, press the "S/F (down)" button to advance to the next item or press "LIGHT (up)" to return to the previous menu item. Below is a list of available menu items.

P/N D00092 PRM470 Page 10 Front Panel Side Panel

P/N D00092 PRM470 Page 11 4.7 Menu Items ITEM RANGE DESCRIPTION Sigma 1-100 Allows user to adjust the Sigma alarm threshold Bkg Time 1-1000 Background time in seconds Motion Timeout 0-3600 Adjusts how long the unit will remain in search or find mode before entering background mode if left motionless. Zero will disable motion timeout and the user will be required to change modes manually Neu Alarm 1-10000 Adjusts the neutron alarm level in counts per second Gamma LLD 0-5.00 Sets the voltage of the gamma channel lower level discriminator Gamma ULD 0-5.00 Sets the voltage of the gamma channel upper level discriminator Neut LLD 0-5.00 Sets the voltage of the neutron channel lower level discriminator Neut ULD 0-5.00 Sets the voltage of the neutron channel upper level discriminator Audio Adj 0-200 Sets the SEARCH mode alarm tone. The higher the number the higher the tone Low Gamma 0-10000 Sets the low alarm fault value for the gamma channel Units CPS,mR/Hr,uSv/Hr Sets the gamma channel display units (mr/hr,usv/hr are not energy compensated. Values are estimated This is not to be used as a survey instrument) CAL CPS/mR/Hr Allows the user to calibrate the unit for CPS per mr/hr. To perform the calibration, place the unit in a known mr/hr field and adjust the K-factor with the "LIGHT (up" and "S/F (down)" buttons until the mr/hr display matches the known field TX DATA ON/OFF Turns RS-232 one second blind broadcast of count EXIT data on/off IMPORTANT: Turn off to increase battery life Exit the menu and return to operation If these parameters are changed, the changes should be documented and retained for future reference.

P/N D00092 PRM470 Page 12 4.8 Field Electronic Alignment Procedures WARNING This procedure involves high voltage and should only be performed by a trained technician! Tools and equipment Since the electronic alignment procedures require specialized tools and knowledge, only a trained technician should work on these instruments. Oscilloscope with greater than 20 Meg. Band width Tweaker or small slotted screwdriver Digital voltmeter with a resolution of 0.1 millivolts High voltage probe with a range of 10,000 Vdc and Zin 100MΩ 5-10µCi 137 Cs test source NOTICE Other mono-energetic sources may be used. Call Rapiscan for full details. Gamma 1. Use the scope to set the high voltage for a first stage gain of 1.5 volt with the 137 Cs (GHA TP1 and R10 upper board). (Reference drawings 3 and 10) 2. Adjust the second stage gain for 4.0V with the 137Cs (GHA TP2 and R17 upper board). (Reference drawings 3 and 10) Neutron 1. Max out the second stage gain, measure the resistance from the wiper to ground and back the pot off 100 ohms from max, nominally 4.9 kohms. (GHA TP2 and R17 lower board). (Reference drawings 3 and 10) 2. Set the high voltage for 1,200 if the anode lead is red and 980 if the anode lead is white (GHA TP1 and R10 lower board). (Reference drawings 3 and 10)

P/N D00092 PRM470 Page 13 5 OPERATIONAL TEST Due to the many different environments and materials being monitored, the operational test will vary from site to site, although several general principles apply in all cases. 1. Select an appropriate source, and instruct the user to approach the source with the Rapiscan Systems PRM470 in the SEARCH or FIND mode. 2. Record the distance at which the unit alarms. 3. Repeat the test several times and record the sources and sizes used. 5.1 Gamma and Neutron Maintenance WARNING This procedure involves high voltage and should only be performed by a trained technician! Little maintenance is required. Periodic inspection is recommended to insure proper functioning. This should include (but is not limited to): - visual inspection for loose wires, etc. - field calibration - checking the settings of the unit - performing a test using sources CLEANING The enclosure should be cleaned using only a mild soap and water. A dampened cloth should be used to prevent water from dripping into the unit. 5.2 Component Access Battery : To remove, disconnect the in line connector between the printed circuit board and the battery and lift it out. To reinstall the battery, reverse the above. The gamma detector assembly can be removed by disconnecting the cabling and removing the brackets that secure them in place. Handle these with care to avoid damage which could cause light leaks. To replace, set the detector in place and fasten the Velcro straps, and connect the cabling. The neutron detector assembly can be removed by disconnecting the cabling and removing the brackets that secure them in place. Handle these with care to avoid damage. To replace, set the detector in place and fasten the Velcro straps, and connect the cabling.

P/N D00092 PRM470 Page 14 6 GLOSSARY CPS or cps: Counts Per Second LCD: Liquid Crystal Display LED: Light Emitting Diode LLD: The Lower Level Discriminator provides an adjustable threshold that determines the lowest signal level that will be accepted as a nuclear pulse by the system s electronics. Some systems have both upper and lower level discriminators that can be used to set a discriminator window. The discriminator window can be used to effectively reduce the background counts, and increase system sensitivity to certain isotopes. Low Background Alarm or Low Background Fault: The condition that occurs if the counts fall below the programmed low background level. This condition prevents further operation until the problem is corrected. Usually set in cps. Standard Background: Standard background requires the full background time for the initial background and updates. ULD: The Upper Level Discriminator provides an adjustable threshold that determines the highest signal level that will be accepted as a nuclear pulse by the system s electronics.

P/N D00092 PRM470 Page 15 7 PARTS LISTS It is recommended that you should contact Rapiscan Systems at RapiscanTSASales@osisystems.com and supply the information listed in section 7.1. 7.1 Spare Parts Ordering Information To facilitate the processing of spare parts orders the following information is required. Product Number Product Serial Number Rapiscan Stock number Part description (from parts list) When ordering programmed proms, the software version is required. This can be found on the prom label. NOTICE Model number suffixes are generally not included in the text of the manual. However, the suffixes in the parts lists must be included on orders for spare parts. FOR ASSISTANCE CALL: Rapiscan Systems 14000 Mead Street Longmont, Colorado 80504 USA Phone: +1.970.535.9949 Fax: +1.970.535.3285 email: RapiscanTSASales@osi-systems.com

P/N D00092 PRM470 Page 16 8 LIST OF DRAWINGS Description Drawing Drawing Number PRM470 External View... 1 PRM470 Wiring Diagram... 2 PRM470 Internal View... 3 *PRCB-472B Schematic Diagram sheet 1 of 3... 4 *PRCB-472B Schematic Diagram sheet 2 of 3... 5 *PRCB-472B Schematic Diagram sheet 3 of 3... 6 PRCB-472B 8673A Component Designator... 7 *GHA-472 Schematic Diagram sheet 1 of 3... 8 *GHA-472 Schematic Diagram sheet 2 of 3... 9 *GHA-472 Schematic Diagram sheet 2 of 3... 0 GHA-472A Component Designator... 11 *Single Signal Pickoff Schematic Diagram... 12 Single Signal Pickoff Component Designator... 13 *VD-1924 Schematic Diagram... 14 VD-1924 Component Designator... 15 Typical Pulse Profile... 16 * Proprietary information not included with the manual. Contact Rapiscan for assistance