High Performance LSZH Fire Resistant Cable

LSOH Flexible Cables

BS /1000V XLPE Insulation LSZH Sheath Cables

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Flame Retardant Overall Screened Instrumentation Cables (multicore)

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP400

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Total Fire Solutions. Includes BS 8519 and the updated BS :

Introduction.

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

FIRE RESISTANT CABLES FP200 GOLD

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

STANDARDS INSTALLATION. Certificate No 077m

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

FIRE RESISTANT CABLES

Catalogue Power Cables

Caledonian Flame Retardant Coaxial Cables

Tratos Railway Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Fire Resistant Cables

Cable technology for highest safety requirements

Lloyd s Register Type Approval System Test Specification Number 3

fire resistant cables

(Notices) EUROPEAN COMMISSION

FIRE PERFORMANCE CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

The Quality Connection. BETAflam Fire Resistant Safety Cables

ENHANCED FIRE PERFORMANCE CABLE

Overhead Line Insulators

INTERNATIONAL STANDARD

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

WORLDWIDE CABLE EXPERTS

Multi-Core Fire Resistant Cable

Catalogue. Instrumentation & Control Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTERNATIONAL STANDARD

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Requirements for Electrical Installations

LV FIRE RESISTANT CABLES

Caledonian fire Resistant signal & Data cables

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0402 Edition February 2016

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Catalogue Telecommunication Cables INTRODUCCIÓN

Traction Cable Radox 3 GKW

Firecel Safety Cables

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

DNVGL-CP-0401 Edition February 2016

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

Wires, Cables, Cords and Adhesive Tapes

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Compact Module. Category 6A FTP Cabling System 1.1

INTERNATIONAL STANDARD

Special Provision No. 683S28 December 2017

INTERNATIONAL STANDARD

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

INTERNATIONAL STANDARD

TYPE APPROVAL CERTIFICATE

This document is a preview generated by EVS

Havells Fire Survival Cables

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

INTERNATIONAL STANDARD

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

INTERNATIONAL STANDARD

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

SPECIAL ELECTRICAL AND OPTICAL CABLES

Telecommunication Cables

Product Specification CAT 6 UNSHIELDED PATCH CORDS

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Caledonian. FIREFLIX ire Resistant Coaxial Cables

THE TRUE FIRE SURVIVAL CABLE

Caledonian Fire resistant Coaxial Cables

Transcription:

1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming part of the SP Distribution plc, SP Transmission plc and Manweb plc networks. 2. ISSUE RECORD This is a Reference document. The current version is held on the EN Document Library. It is your responsibility to ensure you work to the current version. Issue Date Issue No Author Amendment Details Oct 2011 1 Gordon MacKenzie Initial Issue August 2014 2 Gordon MacKenzie General Revision. Issued for Tender only- not published. August 2017 3 Gordon MacKenzie General Revision. Update of industry standards. 3. ISSUE AUTHORITY Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards Name: Frank Berry Title: Circuits Manager Engineering Design and Standards Name: Martin Hill Title: Head of Engineering Design and Standards 4. REVIEW This is a Reference document which has a 3 year retention period after which a reminder will be issued to review and extend retention or archive. DISTRIBUTION This document is not part of a Manual maintained by Document Control and does not have a maintained distribution list. SP Power Systems Limited Page 1 of 22

CONTENTS 1. SCOPE... 1 2. ISSUE RECORD... 1 3. ISSUE AUTHORITY... 1 4. REVIEW... 1 DISTRIBUTION... 1 CONTENTS... 2 5. RELATED DOCUMENTS... 4 5.1 CENELEC Documents... 4 5.2 British Standards... 4 5.3 BASEC British Approvals Service For Cables... 5 6. GENERAL... 5 6.1 Definitions... 5 6.2 Abbreviations... 5 6.3 Conditions of Installation... 6 6.4 Conditions of Operation for General Wiring Cables... 6 6.5 Cable Longevity... 6 6.6 Technical Support... 6 7. TESTING AND APPROVAL... 7 7.1 Type Approval Testing... 7 7.2 Routine and Sample Testing... 7 7.3 Samples... 7 8. TECHNICAL REQUIREMENTS... 8 8.1 Cable Rating Data... 8 8.2 Cable Impedance Data... 8 8.3 Installation Parameters... 8 8.4 Testing... 8 8.5 Reporting... 9 8.6 Other Requirements... 9 8.7 Cable Marking and identification... 9 8.8 Identification... 9 9. SEALING AND DRUMMING... 9 9.1 Sealing... 9 9.2 Drumming... 9 10. QUALITY REQUIREMENTS... 10 11. INFORMATION REQUIRED FROM THE TENDERER... 11 12. SUMMARY OF CABLE TYPES REQUIRED... 12 12.1 General Wiring Cables... 12 SP Power Systems Limited Page 2 of 22

12.2 SWA Standard Power Cables. BS 6724:1997 & A3:2008, Low Smoke Halogen Free (LSHF) 13 12.3 Flexible Mains and Control Cables EPR, BS EN 50525-3-21:2011 Electric cables... 14 13. DOUBLE INSULATED METERING CABLES... 15 14. SCHEDULES FOR CONFIRMATION OF TECHNICAL COMPLIANCE... 16 14.1 General Requirements... 17 14.2 Single Core Cables... 18 14.3 Surface Wiring Cables, PVC insulated PVC sheathed (twin and earth).... 19 14.4 SWA Armoured Cables... 20 14.5 Fire Alarm and Security Wiring Cables... 21 14.6 Flexible Mains and Control Cables EPR, CSP.... 22 SP Power Systems Limited Page 3 of 22

5. RELATED DOCUMENTS This Specification makes reference to the following documents. It is important that Tenderers ensure that they are in possession of the latest issues of these documents together with any amendments. 5.1 CENELEC Documents HD 308 HD 605 Identification and use of cores of flexible cables Electric cables - Additional test methods 5.2 British Standards BS EN 60332-3-10:2009 Tests on electric and optical fibre cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. BS 7655-0:2006 Specification for insulating and sheathing materials for cables. BS EN 60228:2005 Conductors of insulated cables BS 7211:2012 Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire BS EN 60754-1:2014 Test on gases evolved during combustion of materials from cables. Determination of the halogen acid gas content BS EN 60754-2:2014 Test on gases evolved during combustion of materials from cables. Determination of acidity (by ph measurement) and conductivity BS EN 61034-2:2005+A1:2013 Measurement of smoke density of cables burning under defined conditions. Test procedure and requirements BS 7671:2008+A3:2015 Requirements for Electrical Installations. IET Wiring Regulations BS 7870-1:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. General BS 6724:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification BS EN 50525-1:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U). General requirements BS EN 50525-2-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750V (U0/U). Cables for general applications. Flexible cables with thermoplastic PVC insulation BS EN 50525-2-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U). Cables for general applications. Flexible cables with crosslinked elastomeric insulation BS EN 50525-2-51:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U). Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation BS EN 50525-2-83:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U). Cables for general applications. Multicore cables with crosslinked silicone rubber insulation BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U). Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke BS 5839-1:2013 Fire detection and fire alarm systems for buildings. Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises SP Power Systems Limited Page 4 of 22

BS 8434-2:2003+A2:2009 Methods of test for assessment of the fire integrity of electric cables. Test for unprotected small cables for use in emergency circuits. BS EN 50200 with a 930 flame and with water spray IEC 60227-2:1997 Cons Ed 2-1 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V. Test methods 5.3 BASEC British Approvals Service For Cables All general Wiring products will be deemed to be in compliance with this specification if certified by basec. This includes certification for the factory of origin and certification of the product supplied which must be supplied on request. https://www.basec.org.uk/ 6. GENERAL 6.1 Definitions Approved The Specifying Engineer Company Approved in writing by The Specifying Engineer Person nominated by SP EnergyNetworks having responsibility for all technical matters relating to this Specification. Refers to SP Distribution plc and SP Manweb plc. SP Energy Networks (SPEN) SP PowerSystems Ltd, operator of network assets on behalf of the Company. SP Distribution plc SP Manweb plc The Tenderer The Contractor 6.2 Abbreviations The Distribution Licence Holder for the distribution service area formally known as ScottishPower. The Distribution Licence Holder for the distribution service area formally known as Manweb. The supplier invited to submit a tender in accordance with this Specification. The Tenderer who has been awarded a supply contract based on this Specification. BS CENELEC CNE EATS EPR LSZH MDPE PVC SNE UNIPEDE XLPE BASEC CSP British Standard Comité Européen de Normalisation Electrotechnique Combined Neutral & Earth Electricity Association Technical Specification Ethylene Propylene Rubber Low Smoke Zero Halogen Medium Density Polyethylene Poly Vinyl Chloride Separate Neutral & Earth Union Internationale des Producteurs et Distributeurs d'energie Electrique Cross Linked Polyethylene British Approvals For Cables Chlorosulphonated polyethylene SP Power Systems Limited Page 5 of 22

6.3 Conditions of Installation Cables specified in this document will be enclosed in trunking or conduit, or clipped directly in air. Cables may also be installed within cable trenches. During storage and after installation cables can be expected to be subjected to the full range of climatic conditions encountered in the UK. Cables shall not be installed in temperatures of less then Zero degrees Celsius, or greater than forty degrees Celsius. Cable installed in trenches may be surrounded by ground water for most of it s operating life. Where cable is installed in ducts, flooding of ducts can occur resulting in permanently wet sections along the cable route. Cables installed above ground will be supported by means of cleats either vertically or horizontally and these cables may be exposed to direct sunlight for significant periods. 6.4 Conditions of Operation for General Wiring Cables The following are the general conditions under which general wiring cables purchased in accordance with this Specification are required to operate: Nominal system voltages: 400/230 volts. The working voltage of any part of the system does not normally exceed the normal system voltage by more than 10%. Nominal system frequency: 50Hz Cables purchased in accordance with this Specification may be laid alongside or are otherwise associated with power cables operating under the above conditions. 6.5 Cable Longevity Cables offered shall be designed and manufactured to operate satisfactorily under the installation and operating conditions detailed above. The Tenderer shall provide at the time of tender details of manufacturing location(s) for each cable offered. Any Approval granted will be site and line specific and will not be transferable to any other site or line without the prior written agreement of the Specifying Engineer. 6.6 Technical Support From time to time during the contract period questions will arise regarding unusual or non-standard applications where advice will be required on matters such as cable ratings etc. The successful Tenderer(s) will be expected to support SP Power Systems with technical advice on these matters. SP Power Systems Limited Page 6 of 22

7. TESTING AND APPROVAL 7.1 Type Approval Testing All cables offered must be BASEC Type Tested and Qualified according to the requirements of the Technical Specifications and Standards detailed for each cable type. The Tenderer shall provide Product Certification Schedules, Type Test certificates and Type Test reports, including details of independent witnesses, at the time of Tender. If, during the period of the Contract, the Contractor wishes to make any change to the Approved product, packaging or labelling, proposals for such changes shall be notified in writing to the Specifying Engineer. No such changes shall be implemented without the prior written Approval of the Specifying Engineer. If the Specifying Engineer deems that the changes require the Type Approval testing to be repeated, in full or in part, the cost of such testing shall be borne by the Contractor. 7.2 Routine and Sample Testing The Contractor shall carry out all routine and sample tests as required to gain BASEC Approval for each cable. Tenders shall state at the time of tender their proposals for sample test frequencies where such frequencies are not detailed specifically by this Specification or the relevant referenced Standards or Specifications. The Specifying Engineer reserves the right to be present and witness routine and sample tests. Where the Specifying Engineer wishes to witness any such test, the date and time of testing shall be mutually agreed. 7.3 Samples During the tender period the Tenderer shall submit samples for approval as required by the Specifying Engineer. Such samples shall remain the property of SP Power Systems. During the contract period the Contractor shall provide samples as required by the Specifying Engineer. Such samples shall remain the property of the SP Power Systems. During the Contract period the Tenderer shall make available all BASEC audit findings, recommendations and non conformances. SP Power Systems Limited Page 7 of 22

8. TECHNICAL REQUIREMENTS Where a requirement of this Specification differs from that of another quoted Specification or Standard, the requirement of this Specification shall apply. If a Tenderer is unsure regarding any requirement of this Specification, clarification shall be sought in writing from SP EnergyNetworks. SP EnergyNetworks welcomes innovation and will consider alternatives to traditional designs where it can be demonstrated to the satisfaction of the Specifying Engineer that these alternatives meet the functional requirements of this Specification. 8.1 Cable Rating Data For each power cable offered the Tenderer shall provide the following cable rating data:- Cable rating laid direct (Amps) Cable rating laid in PVC/Metal Trunking (Amps) Cable rating laid in PVC/Metal Conduit (Amps) Cable rating in air (Amps) The following assumptions shall be made when quoting ratings:- Single core cables are laid in touching trefoil Maximum spacing factor when installed in trunking as per BS 7671 Maximum spacing factor when installed in conduit as per BS 7671 Ground temperature = 15 0 C Air temperature = 25 0 C Tenderers shall also provide data to show the variation in rating with changes in ambient temperature. 8.2 Cable Impedance Data For each General Wiring cable offered the Tenderer shall provide the following data:- Maximum dc resistance per phase conductor at 20 0 C (Ohms/km) Maximum ac resistance per phase conductor at maximum conductor temperature (Ohms/km) Star reactance at 50Hz (Ohms/km) Star capacitance at 50Hz (Ohms/km) Charging current per phase at normal voltage and frequency (ma/m) Zero sequence impedance R 0 + jx 0 (Ohms/km) 8.3 Installation Parameters For each General Wiring cable offered the Tenderer shall provide the following parameters:- Minimum dynamic bending radius (mm) Minimum static bending radius (mm) Recommended pulling method and maximum pulling tension (kgf) 8.4 Testing The measurement of insulation shrinkage, which is a type test in BS 7870, shall be carried out as a sample test at a frequency of one test per production batch of service cable. SP Power Systems Limited Page 8 of 22

8.5 Reporting The results of the insulation shrinkage tests shall be reported by e-mail to the person nominated by SPEN at the time of contract award. The test report shall also include a QA tracability number and manufactured length associated with that production batch in addition to the line operating speed, conductor resistance, screen resistance, sheath thickness, overall diameter and spark test pass/fail. 8.6 Other Requirements At the time of Tender the manufacturer shall provide details of their understanding of the factors contributing to insulation shrinkage and shall detail control measures taken in their production to minimise insulation shrinkage in the final product. 8.7 Cable Marking and identification The oversheaths of all cables shall be marked in accordance with the requirements of the relevant Standard specified in this document. All cables shall be metre marked throughout the length of the cable and the start and end values shall be marked on the drum label. Three phase low voltage cables shall have the letter H embossed on the oversheath to indicate that the cable has Harmonised core colours in accordance with CENELEC HD 308. 8.8 Identification Each delivery length of cable shall be allocated a unique reference number. This number shall appear on the factory test records covering the cable length, shall be clearly marked on the drum on which the length is delivered and shall be referred to on all invoices and advice notes. 9. SEALING AND DRUMMING 9.1 Sealing The ends of all cables shall be effectively sealed against the ingress of moisture by a method appropriate to the cable type. For cables having inner and outer sheaths (e.g. multicore cables) the sealing arrangement shall be applied to the innermost sheath. Tenderers shall detail at the time of tender their proposed sealing arrangement for each cable type offered. 9.2 Drumming 9.2.1 Cable Protection The cable and cable end projecting from the drum shall be protected from damage during transit, storage and handling on site and include the use of a heat shrink end cap. Tenderers shall state at the time of tender their proposed method of protection for each cable type offered. 9.2.2 Drums Service cable shall be supplied on non-returnable drums. All other drums shall be designed to be recyclable and the Contractor shall arrange to collect empty drums from the Purchaser s normal delivery locations. Tenderers shall state at the time of tender their proposed cable drum sizes and weights for each cable type offered. SP Power Systems Limited Page 9 of 22

9.2.3 Drum Labels All cable drums shall be marked in accordance with the relevant BASEC Approved Specification or Standard. The drum label shall also contain the metre marking start and end values and the unique reference number. All drum labels shall remain legible and durable under normal indoor storage conditions. 10. QUALITY REQUIREMENTS Analysis of any defective items either on receipt or in use will be taken into account by SP Power Systems during any future tender analysis. Tenderers shall operate a fully documented quality assurance system and should confirm this with their tenders and provide a copy of their overall quality policy statement. Tenderers shall also provide at the time of tender copies of any relevant QA Approvals held by them and quality plans for each cable type offered (these should identify the control stages during manufacture and test). Tenderers shall provide BASEC registration documentation, and product certification schedules for all cable types required in this document. SPEN will carry out random goods inward inspections to confirm compliance with the requirements of this specification. SP Power Systems Limited Page 10 of 22

11. INFORMATION REQUIRED FROM THE TENDERER In addition to completing the attached schedules in full, the Tenderer shall provide the following information at the time of tender:- Manufacturing location(s) for all cables offered BASEC Type Test Cert, reports for all cables (see clause 7.1) Details of any alternative type test standards proposed (see clause 7.1) Sample test frequencies for all cables (see clause 7.2) Cable ratings data for all cables (see clause 8.1) Cable impedance data for all cables (see clause 8.2) Cable installation parameters for all cables (see clause 8.3) Long term ageing test evidence for all cables (see clause 6.5) Long term ageing test evidence for all cables (see clause 6.5) Proposed sealing arrangement for each cable type (see clause 9.1) Proposed cable protection for each cable type (see clause 9.2) Drum sizes and weights for each cable type (see clause 9.2) Confirmation of documented quality assurance system (see clause 9.2) Quality policy statement, QA approvals and plans (see clause 9.2) SP Power Systems Limited Page 11 of 22

12. SUMMARY OF CABLE TYPES REQUIRED 12.1 General Wiring Cables 12.1.1 Single Core Cables: BS7211:1998 incorporating amendments No s 1 & 2. Stranded plain annealed compacted circular copper conductors to BS EN 60228, low smoke and halogen free (LSHF) insulation, 450/750 volts grade to BS7211. Acid gas emission to BS EN 60754-1:2014, BS EN 60754-2:2014 IEC 60754, smoke emission to BS EN 61034-2:2005+A1:2013, IEC 60332. Ref Description Supplier Code SC-01 1.5 sqmm 2 stranded Copper (Brown, Black, Grey, Blue, Green/Yellow) 6491B1/5 SC-02 2.5 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow) 6491B2/5 SC-03 4.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow) 6491B4 SC-04 6.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow) 6491B6 SC-05 10.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow) 6491B10 SC-06 16.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B16 SC-07 25.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B25 SC-08 35.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B35 SC-09 50.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B50 SC-10 70.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B70 SC-11 95.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B95 SC-12 120.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B120 SC-13 150.0 sqmm² stranded Copper (Brown, Black, Grey, Blue, Green/Yellow 6491B150 SP Power Systems Limited Page 12 of 22

12.1.2 Surface Wiring Cables, Low Smoke Halogen Free (LSHF) insulated LSHF sheathed (twin and earth). BS7211:1998 incorporating amendments No s 1 & 2. Plain annealed copper conductor to BS EN 60228, Low Smoke Halogen Free (LSHF) insulated one, two or three cores laid flat with an uninsulated circuit protective conductor and LSHF sheathed white. 450/750 volts grade to BS7211. Acid gas emission to BS EN 60754-1:2014, BS EN 60754-2:2014, IEC 60754, smoke emission to BS EN 61034-2:2015+A1:2013, IEC 60332. Ref Description Supplier Code SW-01 1.5 sqmm, 2 core and earth 6242B1/5 SW-02 1.5 sqmm, 3 core and earth 6243B1/5 SW-03 2.5 sqmm, 2 core and earth 6242B2/5 SW-04 4.0 sqmm, 2 core and earth 6242B4 SW-05 6.0 sqmm, 2 core and earth 6242B6 SW-06 10.0 sqmm, 2 core and earth 6242B10 SW-07 16.0 sqmm, 2 core and earth 6242B16 12.2 SWA Standard Power Cables. BS 6724:1997 & A3:2008, Low Smoke Halogen Free (LSHF) 12.2.1 Armoured power cables Plain annealed copper conductor, solid or stranded, circular to BS EN 60228. XLPE insulation. LSHF bedding, galvanised steel wire armour, LSHF outer sheath. Construction to BS 6724:1997+A3:2008. Flame propagation to BS EN 60332-1-2 (single) and BS EN 60332-3-24:2009 (multiple cables). Corrosive and acid gas to BS EN 60754-1:2014, BS EN 60754-2:204, smoke emission to BS EN 61034-2. Ref Description and nominal size Supplier Code SWA- 01 1.5 sqmm 2 Core LSF2X1/5 SWA-02 2.5 sqmm 2 Core LSF2X2/5 SWA-03 4.0 sqmm 2 Core LSF2X4 SWA-04 1.5 sqmm 4 Core LSF4X1/5 SWA-05 2.5 sqmm 4 Core LSF4X2/5 SWA-06 4.0 sqmm 4 Core LSF4X4 SWA-07 16.0 sqmm 4 Core LSF4X16 SP Power Systems Limited Page 13 of 22

12.2.2 Fire Alarm and Security Wiring Cables. Plain annealed copper conductor to BS EN 60228, silicon rubber insulated aluminium/polyester tape screen, tinned annealed copper earth wire low smoke halogen free (LSHF). Cables to BS 7629-1:2008 and fire performance to BS 5839-1:2002 +A2:2008 clause 26.2(d) (standard grade) [and clause 26.2(e) (enhanced grade)]. Outer sheath red, white, orange or black. Fire resistant to BS EN 50200, BS EN 50200 Annex E (standard grade)[ and BS 8434-2 (enhanced grade)]. Flame resistant to IEC 60332-3, BS 6387 CAT CWZ. Corrosive and acid gas emission to BS EN 60754-1:2014, BS EN 60754-2:2014, IEC 60754, smoke emission to BS EN 61034-2, IEC 61034 and flame propagation to BS EN 60332-1-2. Ref Description and nominal size Supplier Code FP-01 FP 1.5 sqmm 2 Core and earth FP2X1/5 FP-02 FP 1.5 sqmm 3 Core and earth FP3X1/5 FP-03 FP 2.5 sqmm 2 Core and earth FP2X2/5 12.3 Flexible Mains and Control Cables EPR, BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U). Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke. Tinned annealed flexible copper conductors to BS EN 60228, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath, 450/750 volts grade to BS EN 50525. Black or White. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2, BS EN 60332 Harmonised code designation HO7BN4-F. Ref Description and nominal size Supplier Code FM-01 1.0 sqmm 2 Core and earth (3 core) 3183TQ1 FM-02 1.5 sqmm 2 Core and earth (3 core) 3183TQ1/5 FM-03 1.5 sqmm 3 Core and earth (4 core) 3184TQ1/5 FM-04 2.5 sqmm 2 Core and earth (3 core) 3183TQ2/5 SP Power Systems Limited Page 14 of 22

13. DOUBLE INSULATED METERING CABLES Plain annealed stranded circular copper conductor, single core, XLPE insulated, (LSZH) sheathed, Ref 6181B. 300/500 volts grade o BS 7889. Brown/White or Grey/White. Flame propagation to BS4066 PT1 and IEC 60227-2:1997 Ref Description and nominal size Supplier Code MC-01 37/2.03 120sq mm Grey/Brown Double insulated 6181B120 37/2.03 MC-02 37/2.03 120sq mm Grey/Blue Double insulated 6181B120 37/2.03 MC-03 19/2.14 70sq mm Grey/Brown Double insulated 6181B70 19/2.14 MC-04 19/2.14 70sq mm Grey/Blue Double insulated 6181B70 19/2.14 MC-O5 19/1.53 35sq mm Grey/Brown Double insulated 6181B35 19/1.53 MC-06 19/1.53 35sq mm Grey/Blue Double insulated 6181B35 19/1.53 MC-07 19/1.35 25sq mm Grey/Brown Double insulated 6181B25 19/1.35 MC-08 19/1.35 25sq mm Grey/Blue Double insulated 6181B25 19/1.35 MC-09 19/1.35 25sq mm Brown/Brown Double insulated 6181B25 19/1.35 MC-10 19/1.35 25sq mm Blue/Blue Double Insulated 6181B25 19/1.35 MC-11 7/1.70 16sq mm Grey/Brown Double Insulated 6181B16 7/1.70 MC-12 7/1.70 16sq mm Grey/Blue Double Insulated 6181B16 7/1.70 MC-13 7/1.70 16sq mm Brown/Brown Double Insulated 6181B16 7/1.70 MC-14 7/1.70 16sq mm Blue/Blue Double Insulated 6181B16 7/1.70 MC-15 7/1.35 10sq mm Grey/Brown Double Insulated 6181B10 7/1.35 MC-16 7/1.35 10sq mm Grey/Blue Double Insulated 6181B10 7/1.35 MC-17 7/1.35 10sq mm Brown/Brown Double Insulated 6181B10 7/1.35 MC-18 7/1.35 10sq mm Blue/Blue Double Insulated 6181B10 7/1.35 MC-19 7/1.04 6.0sq mm Grey/Brown Double Insulated 6181B6 7/1.04 MC-20 7/1.04 6.0sq mm Grey/Blue Double Insulated 6181B6 7/1.04 MC-21 7/1.04 6.0sq mm Brown/Brown Double Insulated 6181B6 7/1.04 MC-22 7/1.04 6.0sq mm Blue/Blue Double Insulated 6181B6 7/1.04 MC-23 7/0.67 2.5sq mm Brown/Brown Double Insulated 6181B2/5 7/0.67 MC-24 7/0.67 2.5sq mm Blue/Blue Double Insulated 6181B2/5 7/0.67 SP Power Systems Limited Page 15 of 22

14. SCHEDULES FOR CONFIRMATION OF TECHNICAL COMPLIANCE In each of the schedules below the Tenderer shall indicate whether the cable offered complies in full or not with the identified requirements by placing a Yes or No in the column against each requirement. Where compliance is indicated by placing a Yes in the appropriate column, the relevant BASEC Type Test report number or Product Certification Schedule, or reference to other evidence of compliance shall be inserted in the Comments field. Each sheet of this schedule should be signed by a responsible representative of the Tendering Company. This Schedule has been completed by Signed Name Position Company SP Power Systems Limited Page 16 of 22

14.1 General Requirements Spec Para Brief Description Compliance? Comments 6.3/6.4 Cables designed and manufactured for installation and operation under specified conditions 6.7 Technical support available during contract period 8 Where the Tenderer is unsure regarding any requirement of this specification, clarification has been sought from SP Energy Networks in writing and this written clarification has been received and understood by the Tenderer. 12 All of the information requested in clause 12 is included in the Tender return. 9 Cable marking and identification 10.2.3 Drum label legibility and durability. Yes No Signed SP Power Systems Limited Page 17 of 22

14.2 Single Core Cables Spec Para Brief Description Compliance? Comments 11.1.1 Compliance with BS7211 11.1.1 Conductors comply with BSEN 60228 11.1.1 Acid gas emission to BS EN 50267, IEC 60754 11.1.1 Smoke emission to BS EN 50268, IEC 60332 11.1.1 Low smoke zero halogen (LSZH) complies with BS 7870-3.50 7.1 BASEC Product Certification Schedule 6.5 Long term ageing test Yes No Signed SP Power Systems Limited Page 18 of 22

14.3 Surface Wiring Cables, PVC insulated PVC sheathed (twin and earth). Spec Para Brief Description Compliance? Comments Yes No 11.1.2 Conductors comply with BS EN 60228 11.1.2 Compliance with BS7211 11.1.2 Acid gas emission to BS EN 50267, IEC 60754 11.1.2 Smoke emission to BS EN 50268, IEC 60332 11.1.2 Low smoke zero halogen (LSZH) complies with BS 7870-3.50 6.5 Long term ageing test 7.1 BASEC Product Certification Schedule Signed SP Power Systems Limited Page 19 of 22

14.4 SWA Armoured Cables Spec Para Brief Description Compliance? Comments 11.2.1 Construction to BS 6724:1997+A3:2008 11.2.1 Flame propagation to BS EN 60332-1-2 (single) and BS EN 60332-3- 24:2009 (multiple cables) 11.2.1 Corrosive and acid gas to BS EN 60754-1:2014, BS EN 60754-2:2014, smoke emission to BS EN 61034-2. 11.2.1 Low smoke zero halogen (LSZH) complies with BS 7870-3.50 6.5 Long term ageing test 7.1 BASEC Product Certification Schedule Yes No Signed SP Power Systems Limited Page 20 of 22

14.5 Fire Alarm and Security Wiring Cables Spec Para Brief Description Compliance? Comments 11.2.2 Fire resistant to BS6387, IEC 60227-2:1997 Cons Ed 2 11.2.2 Flame retardant to BS5839-1:2003, IEC 60332-3 CAT CWZ BS7629-1:1997 11.2.2 Acid gas emission to BS EN 50267, IEC 60754 11.2.2 Smoke emission to BS EN 50268, IEC 60332 11.2.2 Low smoke zero halogen (LSZH) complies with BS 7870-3.50 6.5 Long term ageing test 7.1 BASEC Product Certification Schedule Yes No Signed SP Power Systems Limited Page 21 of 22

14.6 Flexible Mains and Control Cables EPR, CSP. Spec Para Brief Description Compliance? Comments 11.3.1 Complies with BS6500 11.3.1 Heat and oil resistant (HOFR) 11.3.1 Flame retardant to BS EN 60332-1-2, BS EN 60332 6.5 Long term ageing test 7.1 BASEC Product Certification Schedule 11.3.1 Harmonised code H07BN4-F Yes No Signed SP Power Systems Limited Page 22 of 22