makes you independent Solar Technology

Similar documents
Solar Technology. CPC and Sunnyline. collectors. makes you independent. Pelletskessel.

Solar heating systems

The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

Solar collectors. Speaker

Fresh water modules premium-line

Frequently Asked Questions Solar Collector G24

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

A strong team A ++ A +++ ROTEX gas hybrid heat pump

using Solar energy efficient efficiency rate

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

The Ultimate Solution for Electric Central Heating. Fusion. Comet

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

SOLAR TUBE COLLECTORS

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

For latest prices and delivery to your door visit MyTub Ltd

TERMO Combi Cylinder TECHNICAL INFORMATION

Solar technology VITOSOL 100-F VITOSOL 200-F VITOSOL 200-T

Exclusive Green E Condensing Wall-Hung Boilers

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

A strong team A ++ A +++ ROTEX gas hybrid heat pump

SOLAR HEATING SYSTEMS

Heating with log wood

maximise the sun s energy with warmflow solar Warmflow Solar

Solar. domestic hot water systems. Using the sun s energy to provide hot water

Gas condensing boiler (wall mounted) TopGas

Series 1000 & Storage Water Heaters

Type BK 20 BK 30 BK 50

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

S SOLAR RANGE

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

Aquamatic Instantaneous DHW production unit with integrated storage tank

ADVANCE ELECTRIC THERMAL STORE

HT V2 HT Split

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

COMMERCIAL SOLAR SOLUTIONS

The new standard. The best solar absorber tubes. The highest performance collector. Efficient modular assembly system

Solar Thermal Energy

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

The perfect duo. ROTEX thermal store ROTEX solar system

Solar water heating system

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

The owner. Leszek Skiba. The company holds the required certificates and implemented the Quality Management System with ISO 9001:2000 Standard.

The perfect duo. ROTEX thermal store ROTEX solar system

Soak in the Sunshine. Solar Hot Water

TopGas Wall Hung Condensing Gas Boiler

CATALOGUE-PRICE LIST

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

INDIRECT SYSTEM FOR FROST LOCATIONS

Log fired heating system

Systems engineering Slide 1

Installation instructions

English. Heating with logs & wood pellets 20-40

Slide 1 Jul 20, 2006 Viessmann UK

LATENTO Solar system. All-year solar systems Plastic storage tanks Vacuum tube collectors Solar - regulation Accessories

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Hot water on demand with incorporated energy saving function

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

NOW FUTURE BUILDINGS CATALOGUE EUROPE SPRING / SUMMER 2018 HEALTHIER INDOOR CLIMATE + ENERGY SAVINGS WITH ULTRA-EFFICIENT SOLAR AIR TECHNOLOGY

Forward-looking and energy effi cient Biomass heating

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

ECOplus Solar Cylinder

UNLIMITED SOLAR ENERGY. FREE DELIVERY. 100% ENERGY, FREE FOREVER FOR HOT WATER AND HEATING

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Storage systems. Solarbayer. Fire protection insulation ISO B1

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

The types BK 20 to BK 100 convincing power

Simple solutions are usually the best...

Compact and efficient

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

SOLAREKS. Natural Circulated Closed Loop System SOLAREKS

Efficient heating that won t cost the earth

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Solar Hot Water Heating Systems

Heating with wood chips

INDIRECT WATER HEATERS

Heating with pellets kw

ROTEX gas hybrid heat pump. A strong team.

Operating instructions Oil condensing boiler

Gas condensing boiler UltraGas

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Danfoss Solar Solutions Application Handbook

Ciao Green Condensing Wall-Hung Boilers

Installation manual Operating instructions

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Solar Thermal Planning Worksheet Date: / /

Components for solar heating systems

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

2011 Solar Thermal Water Heating Solutions

GASOKOL TANK SYSTEM COMPACT, HYGIENIC, FUNCTIONAL, HIGH-PERFORMANCE

The power of ventilation

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Transcription:

Solar Technology www.fotolia.com

We want you to be more than satisfied we want you to be excited! 2

Sun Heat free of charge! is inexhaustible is environmentally friendly www.fotolia.com 3

The Sun Heat Free of Charge Did you know,...... that the sun delivers enough power in only 3 hours to cover the annual energy demand of the entire planet? Earth Atmosphere Orbit Reflection through the clouds Absorption in the atmosphere WITHOUT LIGHT NO HEAT Scattering in the denser atmosphere diffused radiation direct radiation Diffusion radiation Direct radiation Ground reflection Only a part of the sun s rays can be used for energy production YOUR BENEFIT This part of the sun s radiation is used for heating with solar collector panels. The average annual global radiation in Central Europe is approximately 950 to 1.500 kwh/m 2 The earh moves The angle of the sun on the collector surface changes continually with the Earth s movement. The greatest share of the sun s rays will therefore fall at an angle onto the collector. 70 60 50 40 16 h 15 h MORNING - AFTERNOON / FALL - SPRING 13 h 14 h June 21 May 21 April 21 March 21 Morning July 21 August 21 September 21 11 h Summer 10 h 9 h Evening 8 h Noon June 21 30 17 h February 21 October 21 7 h 20 18 h 10 19 h January 21 December 21 November 21 6 h 5 h December 21 Winter Noon W E S 120 105 75 60 45 30 15 15 30 45 60 75 105 120 90 WEST 0 SOUTH 90 EAST Diagram Solar position chart - 47th latitude Morning 4

... always toward the south would be ideal When designing your solar system the positioning of the collectors plays an important role. An southern alignment (optimal at 10 South-West) and a roof-pitch of 30 to 45 is desirable. In the event of considerable deviations the reduced yield can be compensated for by enlarging the collector surface. YOUR BENEFIT At a westerly alignment and a 30 roof pitch the CPC-collector from SOLARFOCUS will only achieve 80 % of the yield that could be gained from the optimal southern alignment. Roof inclination (degrees) 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 90 90 WEST EAST 80 80 70 70 60 60 Azimuth (degrees) 50 Azimuth 50 (degrees) 70% 80% 90% 95% 100% 40 30 20 10 10 0 SOUTH 20 30 40 The conversion principle light to heat how does an absorber function what makes the absorber so efficient? Shortwave solar rays strike the highly selective coating and are collected at 95% and converted into heat. Heat produces long-wave radiation. The crystalline surface of the coating prevents the heat from radiating. The sealed construction of the CPC-collector prevents the absorbers from contaminations and permanently protects the interior of the collector. Welded copper pipe "Solar liquid" Transports the heat to the tank The sun's rays are absorbed at 95%. Only 5% of energy is lost. (thermal emission) copper plate ca. 0,01 mm 0,2 mm highly selective coating greatly enlarged YOUR BENEFIT The sun's rays cannot penetrate. Greater energy losses Constant power supply for years. Dirt deposits reduce the collector s yield Simplified detailed descriptions 5

CPC-collector... the crucial differences: Why the structure of the collector should be important to you: Because environmental factors, such as wind and weather, UV radiation, snow loads and excessive variations in temperature affect the collector for decades. The collector tray (1) The 1.5 mm leak-proof welded aluminium tank without vent holes forms the foundation. Air and waterproof design without air holes and rivets protect the interior of your collector for decades. The absorber (2) High-selective coated copper absorber with ultrasonic welded heat transfer medium pipe. The floating absorber which is coated on both sides guarantees you the best energy yield. BENEFITS TECHNOLOGY The reflector (3) The cylindrical, high-gloss rolled, galvanically anodized pure aluminium reflector concentrates the penetrating solar radiation onto the vertically installed absorber ship. The reflectors are protected in the casing from environmental influences, which guarantees a long service life. No wear of the coating. Optimum light concentration. Based on the cylindrical design of the CPC reflector, the diffuse part of the light is also absorbed (Kdiff = 0,87). The solar safety glass (4) 4 mm low-iron, prism-structured solar safety glass. Highest light transmission, impact and hail resistant. The special seal (5) 1 Flexible, UV protected special seal. Connects the tray, the glass and the glass strip. Diffusion proof. Prevents the penetration of moisture and contaminants. 8 The glass holding strip (6) Anodized special aluminium section. No rubber seal, but a UV and weather-resistant aluminium strip provides protection for the glass edges. Guarantees permanent adhesion between the glass and the tray. NO VENT HOLES NO PLASTIC NO WOOD 6

The surface sealing joints (7) 1/2 external thread with flat-faced gasket. The surface seals contacting the interior and exterior side of the tray are screwed in plane-parallel with brass nuts and hermetically seal the tray. No environmentally vulnerable rubber or plastic seals. Allows simple connection of the collectors. 4 SCHEMATISCHE DARSTELLUNG The negative pressure relief valve (8) Negative pressure relief valve for 6 pressure compensation. The air expands at the first warm-up of the interior of the collector - and excess pressure develops. The valve opens and the air can escape. When the air cools, the valve closes and a vacuum develops in the interior of the collector. The reflectors support the glass (0,1 bar = 1.000 kg/m 2 ). No corrosion of the interior of the collector due to aggressive outside air. No exchange between interior and exterior air - therefore no heat losses due to convection. No condensation, therefore no degradation of the high-selective absorber coating. 5 3 9 2 7 Ring-groove ventilation (9) The ring-groove ventilation is located on the collector s distribution pipe. The ring-groove ventilation makes it easy to ventilate solar collectors connected in series. NO INSULATION NO RUBBER SEALS 7

CPC-collector... not only for summer The Reflector Principle Patent No.: 9A/593/93F24J The angle of the sun on the collector surface changes continually with the Earth s movement. The greatest share of the sun s rays will therefore fall at an angle onto the collector. 100% 50% DIRECT 50% INDIRECT SUNSET SUNRISE SUNSET SUNRISE Concentration factor: 1, 2... Concentration factor: up to 3...... designates the energy absorption by the absorber on both sides with direct solar radiation.... means still usable temperatures with flat, weak solar radiation. Basically simple, ingeniously inventive. The CPC-collector technology from SOLARFOCUS allows the efficient use of even flat penetrating solar rays. This is important during the transitional period (spring and autumn), since up to 80 % of the sun s rays penetrate at an angle. Your boiler will have a longer break due to the efficient use of the sun! Based on the cylindrical design of the CPC reflector, the diffused part of the light is also absorbed (Kdiff= 0,87). The angle factor is the ratio of the optical efficiency from the current angle of entry to the vertical entry. MORNING 365 DAYS AFTERNOON 1,10 1,02 1,0 YOUR BENEFIT The vertical installation of the absorber allows the use of the inclined penetrating light. Due to the illumination of the absorber from both sides, the rear of the absorber, which would ordinarily lose heat, is avoided (the CPC-collector requires NO insulation) Incidence Angle Modifier (-) Better energy absorption SOLARFOCUS layout FLAT-PLATE COLLECTOR layout The small absorber strip designates a small heat radiating surface and therefore less heat loss (cooler principle). The small absorber strip of the CPC-collector also provides quick heating. 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 EAST SOUTH WEST Declination 8

CPC-collector Technical Data STRUCTURE Dimensions S1 S1k Aperture area S1/S1k Weight (empty) S1/S1k Content S1/S1k Heat loss factor K1/K2 Conversion factor (according to aperture surface) Incidance angle modifier 30 / 50 Diffusion factor (Kdiff) Heat capacity Flow rate Pressure loss at 20 and 50 l/m 2 h Glass cover Max. operating pressure CPC-collector 2.400 x 1.155 mm (2,8 m 2 ) x 65 mm 2.125 x 1.155 mm (2,5 m 2 ) x 65 mm 2,5 m2 / 2,3 m 2 55 kg / 50 kg 1,6 liters / 1,4 liters K1 = 3,3 W/m 2 / K2 = 0,012 W/m 2 0,74 1,1 / 1,02 0,87 3950 J/m 2 K 20-70 l/m 2 h 4,1 mbar/m 2 4 mm solar safety glass 10 bar TESTED ACCORDING TO EN 12975-1 und -2 YOUR BENEFIT Guarantee against condensation for 10 years No insulation inside the collector Perfectly use of flat light 87% diffusion factor Only high-quality materials Simple hydraulic piping Flat structure Suitable for all assembly version Can be used anywhere: Swimming pool heating, hot water preparation, heating support Proven many 1,000 of times The right solution for every case All models can be used in a vertical or horizontal installation. Technical changes reserved 9

Sunny line... the flat collector Why the structure of the collector should be important to you: Because environmental effects, such as wind and weather, UV radiation, snow loads and excessive variations in temperature affect the collector for decades. The collector tray (1) The welded tight aluminium tank forms the foundation. The high quality manufacturing process protects the inside of the collector for decades. The absorber (2) The highly selective solid surfaced absorber (blue-line) stands out for its level of solar absorption of approx. 95% and level of heat emission of approx. 5%. The absorber unit which is fitted so it floats (ultrasound-welded blue-line absorber strip and copper heat-carrying pipe) guarantees the maximum energy useage. Perfect appearance. BENEFITS TECHNOLOGY The solar safety glass (3) 4 mm of solar safety glass with prismatic structure and low lead content Maximum transparency to light. Impact and hailstone resistant. The special seal (4) Special UV-protection seal with permanent elasticity. Joins the tray, glass and beaded edge. Anti-diffusion. Prevents penetration of humidity and dirt. The beaded edge (5) Special anodised aluminium profile. No rubber seals, with a UV-radiation and weather 1 resistant aluminium profile that efficiently protects the glass edges. Guarantees a long-lasting join between the tray and the glass. 3 10 NO PLASTIC NO WOOD

The sealed connections between surfaces (6) 1/2 external thread with butt joint. The surface joints located on the inside and outside of the tray are screwed down parallel to the casing with brass bolts, in such a way that they hermetically seal the tray. No rubber or plastic seals that wear out in outdoor conditions. Single connection of the collector pipes. 8 6 2 7 4 5 Rear wall insulation (7) 50 mm of mineral wool with low binding content. As a result of the low proportion of binding agents that exist in the mineral wool insulation releases almost zero gases. Ring-groove ventilation (8) The ring-groove ventilation is located on the collector s distribution pipe. Makes it easy to ventilate solar collectors connected in series. NO RUBBER SEALS 11

Sunny line Technical Data STRUCTURE DIMENSIONS Sunny-21 Sunny-28 Aperture surface Sunny-21 / Sunny-28 Weight (empty) Sunny-21 / Sunny-28 Capacity Sunny-21 / Sunny-28 Heat loss factor Conversion factor Rate of flow Loss of pressure ati 20 and 50 l/m 2 h Glass cover Max. operating pressure Flat plate collector 1.785 x 1.155 mm (2,1 m 2 ) x 85 mm 2.400 x 1.155 mm (2,77 m2) x 85 mm 1,82 m 2 / 2,5 m 2 40 kg / 50 kg 1,08 liters / 1,3 liters 3,4 W/m 2 K 0,78 20-70 l/m 2 h 4,1 mbar/m 2 4 mm solar safety glass 10 bar TESTED TO EN 12975-1,2 : 200 Ideal application: 0-70 C. Suitable for heating drinking water and swimming pools, and for partial solar ambient heating. V ERLÄN GERTE GARAN TIEGEPRÜFTE QUALITÄT SOLARFOCUS 2013 The right solution for every case All models can be used in a vertical or horizontal installation. Special requirements on request: e.g. pipe outlet on the back, frame profile colours... Can be used anywhere: Hot water, auxiliary heating, swimming pool heating Only high quality corrosion and oxidation-resistant materials used NO RUBBER SEALS, NO PLASTICS, NO WOOD Welded aluminium casing - protects the interior of the collector for many decades Highly selective blue line full plate absorber 50 mm rear wall insulation - ensures high operational efficiency 4 mm low iron solar glass: 92 % solar transmission Low fitting costs thanks to straightforward pipe work Suitable for all mounting types (roof integrated, on roof, free-standing, wall mounted,...)... the slim line to suit every wallet Technische Änderungen vorbehalten 12

Planning and design of a solar system Persons and Intended Use Collector Area Storage Tank octo plus, fresh water module and solar system ca. 5,0 m² 300 liters DHW tank ca. 5,6 m² 300-400 litres DHW tank ca. 8,4 m² 300-500 litres DHW tank pellet top (15 kw), HYKO-tank 2R and solar system 2-4 90m² ca. 14,0 m² 800 litres Hyko Thermal Store or 800 litres stratified tank 3-5 120m² ca. 16,8 m² 1000 litres Hyko Thermal Store or 1000 litres stratified tank thermi nator II with external boiler, buffer store PSR and DHW tank TSB 4-6 150m² ca. 22,4 m² 1500 litres buffer store and 400 litres DHW tank, or 2000 litres tratified tank These design recommendations should assist you in planning your system. The assumed values are for guidance only. Important parameters, such as hot water consumption, roof incline and aspect must be given individual consideration during the planning phase. The house energy index and type of heating are decisive in determining the coverage for partial solar heating installations. thermi nator II with buffer store PS, stratified module, fresh water module and solar system SOLARFOCUS, thanks to hundreds of standard schematics, can aid in your system, from conception and design to inception. 13

Plug-IN Domestic Hot Water Tank DHW tank with pre-fitted pump set and solar control unit Dual coil solar storage tank Also available with high efficiency pump YOUR BENEFITS Simple assembly Read-to-use DHW tank Avoid assembly errors with the pre-assembled solar control unit and pump set. Sensoren S3 Sensor 3 Sensor 2 Sensor 1 S2 S1 Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 300 l 500 mm 600 mm 1794 mm 0,8 m 2 1,52 m 2 148 kg 1892 mm 400 l 600 mm 700 mm 1591 mm 1,0 m 2 1,81 m 2 159 kg 1738 mm 500 l 600 mm 700 mm 1921 mm 1,27 m 2 1,95 m 2 230 kg 2044 mm 14

HYKO Hygiene Combination Tank Combination tank with bare tube coil (second coil available) for heating support and instantaneous domestic hot water preparation Stratified charging pipe for the heating return Instantaneous domestic hot water preparation YOUR BENEFITS Cost-effective, space-saving solution for domestic hot water preparation and solar heating support Simple, cost-efficient piping The excellent insulation minimises heat losses FRESH WATER SYSTEM Schichttrennplatte SRLHVL KRL SRLHVL KRL Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 600 l /R 700 mm 900 mm 1700 mm 1,2 m 2 1,8 m 2 142 kg / 158 kg 1670 mm 800 l /R 790 mm 990 mm 1760 mm 1,6 m 2 2,4 m 2 170 kg / 194 kg 1740 mm 1000 l /R 790 mm 990 mm 2110 mm 2,4 m 2 3m 2 205 kg / 240 kg 2100 mm 1250 l /R 950 mm 1150 mm 2090 mm 2,4 m 2 3m 2 238 kg / 273 kg 2100 mm 1500 l /R 1000 mm 1200 mm 2210 mm 2,4 m 2 3,6 m 2 276 kg / 308 kg 2215 mm 15

Entl. ÖKOZON Stratified Tank Patent No.: 407298... hot water in the hot zone... warm water in the warm zone SF Simply ingenious, ingeniously simple! Galileo Galilei was the first to discover that the density of liquids change as the temperature changes. This principle has been applied in the development of the ÖKOZON stratified tank. 6 Available sizes from 800 l to 2.000 l 8 4 16 70 C 65 C 60 C 55 C 50 C 40 C HRL SRL HVL Entl. KVL El. El. SRLHVL KRL Entl. SRL HRL KRL KVL SR Vent.. HF HR LEGEND: 1 Thermo stratifiying charging lance 2 Stratifying tube heat exchanger 3 LOW-FLOW heat exchanger 4 HIGH-FLOW heat exchanger 5 Stainless steel straight-tube heat exchanger 6 Stratifying charging lance (heat return) 7 Heating flow 8 Boiler return 9 Boiler flow 10 DHW mixer

The best solution YOUR BENEFITS Ventilation 10 WW FRESH WATER SYSTEM No movable parts No external heat exchangers No additional pumps and valves required Simple hydraulic concept 1 2 Hygienic hot water preparation using continuous flow principle High flow rate 3 Preventing cold bridging Stratifying charge lance in the heating return Simple hydraulic integration Space and cost-effective assembly 5 High-quality materials and innovative technology 9 7 guarantee the highest economy. Two types one stratifying system: -T was specifically developed for DHW preparation. The generously sized stainless steel straight-tube heat exchanger provides hygienic DHW preparation in the continuous flow principle. -H is only used for solar heating SRL HRL HVL KRL KVL EL. KW support. In order to prevent cold bridging, the heating and boiler connections are located at the bottom in CW BF front of the stratified tank. Simple and clear hydraulic integration into the heating and solar system. BR The fully recyclable 9 cm PU hard foam insulation provides optimal heat insulation and quick assembly times. Capacity Diameter Diameter Total Output Output Weight Tilted El. screw-in heating without insulation with insulation height 53 kw 62 kw height 6/4 possible 800-H 790 mm 990 mm 2130 mm --- --- 230 kg 2130 mm on request 1000-H 850 mm 1050 mm 2150 mm --- --- 260 kg 2150 mm on request 1500-H 950 mm 1150 mm 2500 mm --- --- 350 kg 2500 mm on request 2000-H 1000 mm 1200 mm 3020 mm --- --- 420 kg 3020 mm on request 800-T 790 mm 990 mm 2130 mm 1300 l/h 1500 l/h 270 kg 2130 mm on request 1000-T 850 mm 1050 mm 2150 mm 1300 l/h 1500 l/h 300 kg 2150 mm on request 1500-T 950 mm 1150 mm 2500 mm 1300 l/h 1500 l/h 390 kg 2500 mm on request 2000-T 1000 mm 1200 mm 3020 mm 1300 l/h 1500 l/h 460 kg 3020 mm on request 17

Buffer Tank with solar coil Buffer storage tank with solar coil (optional with a second coil available for quick charging) Hygienic domestic hot water preparation with external module Ideal in connection with a biomass boiler YOUR BENEFITS Serves as a storage tank for solar and biomass energy Low space requirement Simple, efficient system hydraulics ThV FRESH WATER SYSTEM Zirkulation Circulation optional Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 500 l /R 650 mm 850 mm 1700 mm 1,8 m 2 --- 103 kg 1670 mm on request 800 l /R 790 mm 990 mm 1760 mm 2,4 m 2 --- 130 kg 1740 mm on request 1000 l /R 790 mm 990 mm 2090 mm 3,0 m 2 --- 156 kg 2090 mm on request 1250 l /R 950 mm 1090 mm 2060 mm 3,0 m 2 --- 189 kg 2090 mm on request 1500 l /R 1000 mm 1250 mm 2200 mm 3,6 m 2 --- 210 kg 2210 mm on request 800 l /2R 790 mm 990 mm 1760 mm 2,4 m 2 1,8 m 2 154 kg 1740 mm on request 1000 l /2R 790 mm 990 mm 2090 mm 3,0 m 2 2,4 m 2 189 kg 2090 mm on request 1250 l /2R 950 mm 1090 mm 2060 mm 3,0 m 2 2,4 m 2 221 kg 2090 mm on request 1500 l /2R 1000 mm 1250 mm 2200 mm 3,6 m 2 2,4 m 2 242 kg 2210 mm on request 18

Buffer Tank without solar coil Buffer storage tank for large-scale solar energy systems With external two-zone solar stratified charging module Ideal in connection with a biomass boiler YOUR BENEFITS Serves as a storage tank for solar and biomass energy Energy is supplied only when required Avoids unnecessary boiler start-ups and low-load operation - longer service life for the boiler and a higher solar coverage rate for your solar energy system ThV FRESH WATER SYSTEM Zirkulation Circulation optional SLM Optionally with fresh water module or DHW tank SRLHVL KRL Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 500 l 650 mm 850 mm 1700 mm --- --- 79 kg 1670 mm on request 800 l 790 mm 990 mm 1760 mm 97 kg 1740 mm on request 1000 l 790 mm 990 mm 2110 mm --- --- 114 kg 2090 mm on request 1250 l 950 mm 1200 mm 2060 mm 146 kg 2090 mm on request 1500 l 1000 mm 1240 mm 2210 mm --- --- 163 kg 2210 mm on request 2000 l 1100 mm 1340 mm 2440 mm 225 kg 2450 mm on request 3000 l 1250 mm 1490 mm 2720 mm --- --- 280 kg 2705 mm on request 4000 l 1400 mm 1640 mm 2900 mm 431 kg 2910 mm on request 5000 l 1600 mm 1840 mm 2995 mm --- --- 504 kg 3010 mm on request 19

FWM 26-95 Fresh water module Flow rates: 26l/min, 40l/min, 50 l/min, 75 l/min, 95 l/min Constant DHW temperature Optimum stratification of the heating water in the buffer storage tank 9 12 13 YOUR BENEFITS Hygienic domestic hot water preparation Delivered ready for connection Simple assembly Low return temperatures FRESH WATER SYSTEM 8 6 11 10 14 7 15 LEGEND: 1 Cold water inlet 2 Shutoff valve 3 Non-return valve 4 Dirt trap 5 Current switch 6 Non-return valve circulation (optional) 7 Dual-circuit control 8 Circulation pump (optional) 9 Circulation 10 Flushing option 11 Ultra-fast hot water sensor 12 Hot water 13 Buffer store inlet flow 14 Stainless steel plate heat exchanger 15 Wall-mounting bracket 16 Circulation pump 17 Insert non-return valve 18 Buffer return 19 Ready-to-connect wiring 5 Functional principle FWM 4 17 16 3 2 19 1 18 Flow rate / heat pump at 50 C buffer flow FWM 26 FWM 40 FWM 50 FWM 75 FWM 95 FWM 26 FWM 40 FWM 50 FWM 75 FWM 95 Buffer flow C 60 60 60 60 60 50 50 50 50 50 Cold water inlet C 10 10 10 10 10 10 10 10 10 10 DHW outlet C 45 45 45 45 45 45 45 45 45 45 DHW outlet l/min 26 40 50 75 95 15 25 40 57 74 Return temp. to buffer C 21 21 21 21 21 21 21 21 21 21 Max. output kw 63 84 130 180 230 37 61 98 139 181 Electr. supply V 230 230 230 230 230 230 230 230 230 230 Connections 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 3/4 IT 3/4 IT 1 IT 1 IT 1 IT Conn. Circulation 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 3/4 IT 3/4 IT 1 IT 1 IT 1 IT Height mm 770 770 960 1130 1130 770 770 960 1130 1130 Width mm 330 330 370 440 440 330 330 370 440 440 Depth mm 350 330 510 630 630 350 330 510 630 630 Weight kg 15 20 38 60 65 15 20 38 60 65 20

SLM 20-150 Solar stratified charging module with dual-circuit control For optimum charging of the buffer storage tank on two levels From 20 m² - 150 m² collector area Attractive cover design 5 8 7 1 2 9 6 19 10 11 13 20 14 12 YOUR BENEFITS Optimum energy utilisation through stratified charging of the buffer storage tank Space-saving Minimum effort required for assembly Delivered ready for connection LEGEND: 1 Speed-controlled solar pump 2 Solar check valve 3 Ready-to-connect wiring 4 Wall bracket 5 Solar manometer 6 Solar safety valve 7 Flow regulator 8 Flow volume sensor with return sensor (optional) 9 Solar return 10 Solar flow 11 3-way motor valve for changing the buffer charging: buffer charging top A buffer charging down B 12 Shutoff valve 13 Dual-circuit control 14 Venting option 15 Speed-controlled buffer tank charging pump 16 Puffer-Rückschlagventil 17 Flow regulator 18 Buffer tank check valve 19 Stainless steel plate heatexchanger with insulation 20 Buffer charging top A 3 15 16 17 Functional principle SLM 4 18 SLM 20 SLM 40 SLM 60 SLM 80 SLM 100 SLM 150 Colloctor Area m 2 up to 20 up to 40 up to 60 up to 80 up to 100 up to 150 Power kw up to 10 up to 20 up to 30 up to 40 up to 50 up to 65 Primary pump 20/7 20/7 20/11 20/11 25/13 25/13 Secondary pump 15/4 15/4 15/6 15/6 25/7 25/7 Buffer connections top/middle 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 5/4 OT Buffer connections return 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 5/4 IT Connections solar flow 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 5/4 IT Connections solar return 3/4 OT 3/4 OT 1 OT 1 OT 1 OT 1 OT Height mm 770 770 960 960 1130 1130 Width mm 330 330 370 370 440 440 Depth mm 350 330 510 510 630 630 Weight kg ca. 25 ca. 30 ca. 45 ca. 55 ca. 65 ca. 85 For any size home, hotels, restaurants, sports halls and schools. 21

SOLARFOCUS INNOVATION ECONOMY QUALITY We shape the future with products that serve mankind and protect the environment! SOLARFOCUS is committed to researching, developing, manufacturing and selling environmental technology in the fields of: Biomass heating, Solar systems AWARDS: Young Entrepreneur s Award Innovations Award 1995 Nomination for the State Award for Innovation Voted the leading Upper Austrian company for Brilliant Business Ideas Pegasus in Gold Environmental Protection Award of the Upper Austrian Region House Technology Award 2004 Innovation Award EnergieGenie 2011 and many others Storage technology. SOLARFOCUS are one step ahead: The research, development and cooperation with research institutes and prestigious partners has led to our dynamic development. Our products are on offer throughout Europe. The courses and seminars held on a permanent basis with our partners guarantee personalised advice and professional installers for you.. 22

The production ENVIRONMENT - FUTURE All our work is done by people for whom the environment and the use of renewable technology is a priority. SOLARFOCUS combines innovative technologies with modern production! 23

Everything from one supplier SOLARFOCUS Solar systems SOLARFOCUS Biomass boilers SOLARFOCUS Storage technology EN ISO 9001 certified Solar Log Wood Wood Chip Pellets TESTED QUALITY V ERLÄN GERTE GARAN TIEGEPRÜFTE QUALITÄT SOLARFOCUS 2013 Your specialised dealer Solar thermal plants Biomass boilers SOLARFOCUS GmbH Werkstraße 1 A-4451 St. Ulrich/Steyr e-mail: office@solarfocus.eu Tel.: +43 (0) 7252 / 50 002-0 web: www.solarfocus.eu Fax: +43 (0) 7252 / 50 002-10 05/2011