EZ9Plus & EZ11Plus Instructions on: Operating

Similar documents
Operation and Maintenance Manual

EZPlus Fully Automatic Sterilizers

OPERATION & MAINTENANCE MANUAL

RELIABLE. The Midmark M9 and M11 UltraClave Automatic Sterilizers - make sterilization reliable and efficient.

OPERATION & MAINTENANCE MANUAL

Tabletop 2340 EA-D Class S Autoclave 19 Litres

STATIM 2000/5000 G4 CASSETTE AUTOCLAVE. Operator s Manual

Operation and Maintenance Manual

OPERATI ON & MAI NTENANCE MANUAL

Available from. M3 ULTRAf AST. Phone (502) Toll-free (800) Online

OPERATION & MAINTENANCE MANUAL

M9 M /M3 11/ Automatic Sterilizers

OPERATION & MAINTENANCE MANUAL

Instruction Manual for the Revolutionary Science Saniclave

The Do's and Don ts in the Instrument Sterilisation Process

BRAVO AUTOCLAVES. Installation Notes. BRAVO 1 Quick Start Guide SD-402 Rev. 1.0 Copyright 2012 SciCan Ltd. All rights reserved

STATIM 2000/5000 G4 CASSETTE AUTOCLAVE TM

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Replacing the Wiper Cleaner

AUTOMATIC STERILIZERS

STATCLAVE G4 - Chamber Autoclave

PERFORM Operating Document

STERITITE INSTRUCTIONS FOR USE

PICNet CONFERENCE 2013

Instrument Processing. Midmark Animal Health Products

AUTOCLAVE STEAM STERILIZERS (BENCH TOP)

Harvey Chemiclave EC5500/EC6000 Sterilizers

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

LabClave.Com OPERATION & MAINTENANCE MANUAL. Horizontal Autoclave Model: Z-LABCLAVE-01-1 S/N

Autoclaves and Accessories for Healthcare Professionals

Operating Instructions

STATIM 2000/5000 CASSETTE AUTOCLAVE

MIDMARK INSTRUMENT PROCESSING

Autoclaves. Steam Autoclaves

Operations Manual. Part Number: For Research Use Only

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

Policy # MI_WASH Department of Microbiology. Page Quality Manual TABLE OF CONTENTS APPENDIX I STERILIZATION AND GLASS WASHING TECHNICAL MANUAL...

Posizione logo. Instructions for use MS-22. MS-22 EN13060-ST55- ENG - Rev. 3

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Veterinary Autoclave

STATIM 900 AUTOCLAVE. Operator s Manual. STATIM 900 Operator s Manual Rev 2.0.

LS5 VACUUM & NON-VACUUM AUTOCLAVES. Instructions for use. ST-IM61e

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

STATIM Operator s Manual Gebruikershandleiding Manuel de l utilisateur Bedienerhandbuch Manuale d uso Manual del operario CASSETTE AUTOCLAVE

AMSCO C Series Small Steam Sterilizers 16 x 16" (406 x 406mm) 20 x 20" (508 x 508 mm)

Posizione logo. Instructions for use MB17 / MB22. LINA MB ENG - Rev. 3.1

M3 UltraFast Dental Handpiece Sterilizer

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

TC-720 RECYCLING BALER

MODEL NO.: Empressa S330 DIGITAL STEAM PRESS INSTRUCTION MANUAL

Bravo Display Warning Messages

OPERATION & MAINTENANCE MANUAL

Step 1: Entering maintenance mode and cap wiper clean menu.

Harvey Chemiclave 5000 Owner And Operator Guide

PL 70 - PL 130 low temperature H 2

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

PREFERENCE ICC. A Complete System For Efficient Sterilization

Introducing the latest model in Prestige Medical s first-class range of Advance autoclaves - Advance Pro.

UNIVERSAL MARINE INDUSTRIES 1)

OPERATOR MANUAL Amsco Eagle 3000 Series FLJ Floorloading Vacamatic Sterilizers. (10/05/01) P Rev. 7

Use & Care Guide. Get the most from your new Keurig brewer

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Key Operator Test Study Guide

Professional sterilization systems

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

Classic Media Operating Instructions

Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Operating / User Manual

K-COMPACT Use & Care Guide. Get the most from your new Keurig brewer

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

STATIM 2000/5000. Operator s Manual. C a s s e t t e A u t o c l a v e.

CLEANING INSTRUCTIONS

POLYMIX PX-IG 2000 Operating Instructions

Protection. in un unica autoclave E10

Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

Manual Page 1 of 8. Manual. Laboratory autoclave

INSTRUCTIONS CertoClav EL

MLS-3751 MLS Labo Autoclave INSTRUCTION MANUAL. Model Nos. Contents. High-pressure Steam Sterilizer. Page

No.19,Lane 346,Changxing Road,Jinangbei District, Ningbo ,China TANZO E TOUCH

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

getinge quadro tabletop SteriLiZer

Sterilizers N e w G e n e r a t i o n

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

HydroFlux Welder Torch System T0-102 / T0-103

Principles and Techniques of Instrument Processing and Sterilization

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Operator s Manual Use and Care Instructions

OPERATION AND MAINTENANCE MANUAL

Steam sterilizer AHS-75-DRY

K-SELECT Use & Care Guide. Get the most from your new Keurig brewer

DIGITAL FABRIC STEAM PRESS INSTRUCTION MANUAL

OPERATOR MANUAL Amsco Century TM Medium Steam Sterilizer 26" x 26" (660 x 660 mm) Scientific. (07/16/07) P Rev. 0

Let s get brewing. Quick Start Guide

INSTRUCTION MANUAL. Elite Digital Steam Press SSP-2202

WHA 3000V Hot Air Station

Standard Operating Manual

deep fat fryer CDF7S WARNING:

Transcription:

EZ9Plus & EZ11Plus Instructions on: Operating

Step 1 Turn the unit on by setting the rocker switch mounted on the right side of the front panel to the On position. NOTE: The EZ11Plus has an automatic pre-heating mode which activates automatically in the Wrapped Instruments, Pouches, Handpieces, and Custom A cycles. Use caution since pre-heating will make the bottom of the chamber hot. (This feature is not active in the EZ9Plus.)

Step 2 Open the door when System Ready is displayed on the screen

Step 3 Place your thumb on the plastic door cover and the other fingers in the handle pocket. Pull the handle until the latch of the door is released. NOTE: This machine is equipped with an electronic door lock. The door will not open when the sterilizer is running a cycle, when the power is off, or when the display screen does not read System Ready.

Step 4 Fill the reservoir by pouring steam distilled water, gently, into the front funnel until it reaches the top of the blue area on the level gauge. This reservoir is designed with an overflow and filling the reservoir above the safe level as indicated on the Front Fill Funnel will cause excess water to spill out below the machine onto the counter

Unwrapped Instruments 270 o F Wrapped Instrument, Pouches 270 o F Unwrapped Delicate Instruments 250 o F Handpieces 270 o F Step 5 Select a program to run by using the UP or DOWN arrow keys. (Programs can only be selected when the door is open.)

Step 6 Adding extra dry time can be done if the default drying time is not adequate. Press the UP/DOWN keys simultaneously for 1-2 seconds then select Add extra dry time from the Quick Options Menu by pressing the START/STOP key. Use the UP/DOWN keys to select the amount of additional dry time and press the START/STOP key (see sec 7.1.1 in the Operator s Manual for more details).

Proper loading options for EZ9Plus include: EZ9Plus loaded with 3 stainless steel trays EZ9Plus loaded with 2 stainless steel trays and optional pouch rack EZ9Plus loaded with 2 full and 2 half cassettes Load the autoclave properly according to instructions in sec. 10 of the Operator s Manual. Separate instruments of dissimilar metal, don t overload the unit, observe maximum weight limits. Using a pouch rack with wrapped instruments will improve efficiency.

Proper loading options for EZ11Plus include: EZ11Plus loaded with 5 stainless steel trays EZ11Plus loaded with 4 stainless steel trays and pouch rack EZ11Plus loaded with 4 full and 4 half cassettes (must load vertically) Load the autoclave properly according to instructions in sec. 10 of the Operator s Manual. Separate instruments of dissimilar metal, don t overload the unit, observe maximum weight limits. Using a pouch rack with wrapped instruments will improve efficiency.

Close the door by holding the handle in the open position while pushing the door until it comes to the closed position, then releasing the handle. The Door Open symbol will be replaced with System Ready on the screen once the door is closed. Should the Door Open symbol remain on the screen, gently pressing on the door will engage the lock and secure the door.

Start the cycle by pressing the START/STOP key.

At the end of a successful cycle, the screen shows the Cycle Ended message and the door is automatically unlocked. Open the door and use the tray handle or wear heat-resistant gloves to remove the load from the autoclave. On completion of the cycle, the load should be visually inspected to ascertain that the load is dry, and that sterilization indicators have made the required color change.

Use only FDA cleared chemical & biological indicators designed for steam sterilization that are compatible with the particular sterilization cycle temperature and exposure time being monitored. At least once a week use a biological spore test (Bacillus Stearothermophilus) in any load to insure proper sterilization (be aware testing standards may vary; contact appropriate state/local agencies for specific sterilization guidelines for your office). Always follow the spore test manufacturer s instruction. Be sure to follow all maintenance instructions as outlined in section 12 of the Operator s Manual. -END-