MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Similar documents
Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

Technologies, Solutions, and Applications. Radiation-based Level

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Density System

Operating Instructions

Technical Reference Manual

Industrial Grade Gas Detection Detecting The Difference

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

M E A S U R E M E N T S D I V I S I O N

Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement

Ronan Model X90 Series Point Level Monitor

Temperature Solutions Line Card

HIGH CAPACITY PRODUCT LINE

Nuclear Density Gauges

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Level gauges Series LS Level indicator, switch and transmitter for liquids

HIGH CAPACITY PRODUCT LINE

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Model D12-IR. Digital Gas Transmitter...

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

A New Standard of Excellence

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Specification for On-Line UPS Battery Monitoring and Data Management System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Section B Field Instruments

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

GasGard 100 Control System

SECTION Fluorescent Dissolved Oxygen Measuring System

Radiation Monitoring Systems

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Triton Series High Efficiency Boiler

Altman Lighting Spectra Cyc UV 50 Specification

EXCELLENCE in Solutions Products Service

Honeywell SLATE ICM Platform

APPLICATION DATA SHEET

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

SiteSentinel itouch Console

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

WASTEWATER Online UV%Transmission Analyzer

Enraf Servo Gauge 854 XTG

Features and Benefits

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

APPLICATION DATA SHEET

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Phoenix Artificial Lift Downhole Monitoring. Improving artificial lift system performance

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010

Environmental Radiation Monitoring System

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Integrated Automation Instrumentation & Terminal Devices

Enraf Servo Gauge 854 ATG

WEB GAUGING AT A GLANCE

Recalibrate the way you look at gas detection

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

VD 53 - Vacuum drying oven for non-flammable solvents

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

UV - flame detector dual fuel burners for intermittent burner operations

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS

Troubleshooting Thermo Scientific LevelPRO Gauges

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

for Drinking Water Systems

Hotplates, Magnetic Stirrers and Stirring Hotplates

I/A Series 716C 1/16 DIN Temperature Controller

Controllers, Indicators & Set Point Programmers

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Temperature Control Systems

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Packaging in Consumer Goods

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

DensityPRO+ Gamma Density System with Remote Transmitter User Guide P/N Part of Thermo Fisher Scientific. Revision C

Terminal Automation Solutions

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

SmartVFD HVAC and BYPASS

Integrated Process Solutions. Series 49. Thermal Management System

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Process Alarm Solutions

SECTION Free/Available Chlorine Analysis System

Nardalert S3 TM Non-Ionizing Radiation Monitor

PHOENIXL 300 New Standards in Leak Testing. Technical information

Rosemount 3051CFC Compact Flowmeter

Transcription:

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Why Multi-Point DENSITY ARRAY? Leadership in Radiation-Based Measurement Ohmart/VEGA is proud to offer the ultimate in fixed-point interface profiling measurements, the DSG Multi-Point Density Array (MDA). Offering high resolution and unparalleled method of measuring interfaces including those with emulsion layers, the DSG MDA is designed to operate in the most difficult of applications including: Free Water Knock Out vessels ( FWKO) Treaters De-Salters Low and High Temperature Separators

4 :: DENSITY ARRAY :: Features & BENEFITS Accuracy and Repeatability Ohmart/VEGA s MDA system provides accurate and repeatable density information, specific to each horizontal plane. Continuous Density Output A continuous density output is provided from each individual measurement point providing the operator information on the density of the oil, emulsion and water. Emulsion Detection As these outputs change on multiple gauges, the movement of the interface and the size of the emulsion layer can be determined. Low Maintenance The system is low maintenance because it does not contact the process directly (no wetted parts). Thin coatings on the source dry well will have minimal affect on the measurement. Uninterrupted Operation With multiple measurement points a failure of one detector does not shut down the operation of the vessel. Flexible Mounting Configuration Internal structures in the vessel, such as electrostatic grids, can alter the mounting configuration, but typically can be accommodated. Additionally, external mounting of the detectors and insertion sources can provide flexibility for future changes in the measurement span. Extensive Diagnostics The use of Ohmart/VEGA s OhmView Software program provides extensive diagnostics of each gauge via a connection with the 4 to 20 madc HART Protocol signal of each gauge. Alternatively, all gauge diagnostics can be accessed through a single connection with OhmView via a gauge to gauge RS485 connection.

Principles of OPERATION A continuous density output is provided from each individual measurement point providing the operator information on the density of the oil, emulsion, and water. As these outputs change on multiple gauges, the movement of the interface and the size of the emulsion layer can be determined. INTERFACE WITH EMULSION LAYER DEFINED (CLEAR) INTERFACE

6 :: DENSITY ARRAY :: System COMPONENTS The MDA System Consists of 3 Components: Source Holders: containing a source of gamma radiation Radiation-based Detectors Operator Interface System: displays the detector outputs to indicate the process conditions Specific selection of these various components is dependent upon each application and the customer s measurement purpose. Vessel size, shape, wall thicknesses, measurement span of interest, measurement span resolution, ambient and process temperatures, and other application variables will determine the number and specification of the individual components of the system. The measurement span and resolution determine the number and orientation of the detector array, mounted on the outside of the vessel, which determines the source holder and source requirements (number, size, location, and construction) normally inserted into a dry well on the vessel through a flanged interface between the source holder and the vessel dry well. Dry wells can be straight or curved to meet the needs of the applications. The customer interface receives the detector outputs, generally multiple 4 to 20 madc HART Protocol outputs and manipulates the outputs to provide the operators with an indication of the interfaces in the vessel. The Ohmart/VEGA MDA can simply provide multiple outputs to a distributed control system (DCS) for a graphical indication from each gauge or combine the signals as appropriate to provide a measure of the thickness of various interfaces or an overall level indication.

SOURCE HOLDERS SHLM Series of Source Holders Insertion type source holder for installation on a process drywell. Available with a stainless steel cable or solid rod versions Multiple source configuration available Shutter lockout (optional) Able to be used on high pressure or temperature applications

8 :: DENSITY ARRAY :: System COMPONENTS continued RADIATION-BASED DETECTORS Electronics The GEN2000 electronics is a modern generation of compact, light weight, and modular electronics utilized by many Ohmart/VEGA level and density detectors. Cast Aluminum Compact Housing Light weight and compact Available with PVC coating for aggressive environments Modular Electronics Easy maintenance Surface mounted component technology for increased reliability Outputs 4-20 madc with HART Protocol communications Foundation Fieldbus digital protocol Universal Power Input Power supply can be connected to an AC or DC input Configuration HART Handheld PC software OhmView 2000 O-ring Seal Design To prevent moisture infiltration and allow 360 degrees orientation, the housing incorporates o-ring seals at the threaded connections

OPERATOR INTERFACE SYSTEM PLC-Based Interface As an option Ohmart/VEGA can provide a programmable logic controller (PLC) to either locally or remotely display the detector information. The remotely mounted PLC can also be configured to provide the measurement outputs back to a DCS system via a single ModBus or ether digital signal. The PLC display will display individual densities in each specific zone of measurement. The target densities for oil and water can also be displayed. Relay outputs can provide alarming capabilities. A combination of point density outputs can indicate overall vessel levels. The PLC system can be mounted remotely or locally If mounted locally, at the separator, it allows all density measurements to be transmitted via a single ModBus or other digital signal back to the customers control system, thus reducing wiring requirements. OhmView 2000 Software User friendly English prompt software tool for configuration, maintenance, trending and diagnostics of the GEN2000 series gauges.

10 :: DENSITY ARRAY :: Training & SERVICE Ohmart/VEGA is able to meet all of your radiation service and training needs. With state of the art classroom facilities, service personnel located world wide, and a full production and service facility, Ohmart/VEGA is always ready to provide the following: 24-hour emergency service phone support Radiation survey meter calibration Product training and system operation Radiation safety school certification Wipe test and wipe test analysis Service, maintenance, and disposal of source material Start up and commissioning

Other Ohmart/VEGA Interface Measurement SYSTEMS CONTINUOUS RADAR LEVEL The VEGAFLEX 67 is a guided microwave sensor designed to measure the level of the interface between two liquids. The primary output is the level of the lower liquid, but the overall level information is available by using additional signal conditioning instruments. CONTINUOUS LEVEL The FiberFlex is the industry s only flexible radiation level detector and features Ohmart/VEGA s GEN2000 family of electronics. With its patented fiber optic scintillator bundle, the FiberFlex has significant advantages over both solid scintillators and traditional ion chamber detectors. NUCLEAR INTERFACE MEASUREMENT The SmartScan Profiler uses an integral source that is contained within the leg of the unit. The source is raised and lowered by a motor-driven tape to provide full vessel scanning.

4170 Rosslyn Drive Cincinnati, Ohio 45209 toll free: 1.800.FOR.LEVEL telephone: 513.272.0131 fax: 513.272.0133 web: www.ohmartvega.com email: info@ohmartvega.com 35237-US-080703