INSTALLATION INSTRUCTIONS

Similar documents
CONTENTS DESCRIPTION UNPACKING DIMENSIONS

CONTENTS WIRING DIAGRAM

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

INSTALLATION INSTRUCTIONS

Installation Instructions Exhaust Fan With Light

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

HUMIDITY SENSING BATH FAN

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN / LED LIGHT

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

breeze easytm model # F100-1W

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

INSTALLATION MANUAL AND USER GUIDE

Please Read and Save These Instructions Safety Information

READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN WITH LIGHT AND HEATER

INSTALLATION MANUAL AND USER GUIDE

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

VENTILATION FAN WITH BLUETOOTH SPEAKER

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

e Bath Fan with Light User s Guide

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Heater/Exhaust Fan/Light User s Guide

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Bath Fan with Light User s Guide

Installation Instructions Remote Blowers

READ AND SAVE THESE INSTRUCTIONS

Use, Care, and Installation Guide

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan

Bathroom Exhaust Fan/Fluorescent Light Combination

Installation Instructions

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Insulated Ventilators. Operating Instructions & Parts Manual

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Installation Instructions Preference Wall Mount Range Hood

Integrated Ventilation System

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

High Power Range Hood

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Cooktop Chimney Ventilation Hoods

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

UNDER CABINET RANGE HOOD

User s Manual WS-5830SS WS-5836SS WS-5842SS

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Easy installation in both new construction and retrofit

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

RP, GP, XP Pro Series Installation Instructions

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Installation. Professional Built-in Hoods

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

Pro Ventilation Hood Liners

Serenity Series Auto Sensing Everything Bathroom Fan

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the


Installation Instructions

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Imperial. Read Before Starting Installation!

Easy installation in both new construction and retrofit

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Downdraft Raised Vent

SAFETY AND INSTALLATION MANUAL MODEL 8100

Solatube Daylight Dimmer Installation Instructions

Humidity and Thermostat control box for Attic Fan

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

Transcription:

INSTALLATION INSTRUCTIONS Ventilating Fan Representative models: Model No. FV-0511VQ1 FV-0511VQC1 FV-0511VQ1 Contents GENERAL SAFETY INFORMATION --------------2~3 DESCRIPTION ----------------------------------------4 UNPACKING -----------------------------------------4 SUPPLIED ACCESSORIES --------------------------4 DIMENSIONS -----------------------------------------5 WIRING DIAGRAM -----------------------------------6 SELECTOR INDICATION (FV-0511VQC1 only) ----------6 OPERATION (FV-0511VQC1 only) ------------------7 FEATURE ---------------------------------------------7 INSTALLATION (NEW CONSTRUCTION) --------8~9 INSTALLATION (RETROFIT) -----------------------10 MAINTENANCE (CLEANING) ------------------10~11 PRACTICAL GUIDE TO INSTALLATION -----------------11 SPECIFICATIONS -----------------------BACK COVER PRODUCT SERVICE --------------------BACK COVER FV-0511VQC1 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Please carefully read the GENERAL SAFETY INFORMATION Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference. 1 5 V Q 1 0 4 2 0 B

GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. WARNING NOTICE Denotes a potential hazard that could result in serious injury or death. Denotes a hazard that could result in minor injury. Denotes a hazard that could result in property damage. The following symbols are used to classify and describe the type of instructions to be observed. This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely. This symbol is used to alert users to a specific operating procedure that must not be performed. This symbol is used to alert users not to disassemble the equipment. This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal. WARNING To reduce the risk of fire, electric shock or injury to persons, observe the following : Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. 2 If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

GENERAL SAFETY INFORMATION CONTINUED WARNING These models are UL listed for tub and shower enclosures. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. It may cause fire or electric shock. A statement to the effect that when the product is to no longer be used, it must not be left in place but remove, to prevent it from possibly failing. joist must be subjected to static load more than five times the weight of the product. Do not install with a method which is not approved in the instructions. Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise. This product must be properly grounded. Install the fan at least 1.5m(5feet) above the floor, and the fan must be installed above a counter or major appliances that serves as a barrier. Do not install this ventilating fan where interior room temperature may exceed 104 F (40 C) Make sure that the electric service supply voltage is AC 120V, 60Hz. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). Always disconnect the power source before working on or near the fan,motor or junction box. Protect the supply wiring from sharp edges oil, grease, hot surfaces, chemicals or other objects. Do not kink the supply wiring. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. (Cooking area) Do not install above or inside this area 45 45 Not for use in cooking area. (Fig.A) The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided. Cooking equipment Fig. A Floor 3

GENERAL SAFETY INFORMATION CONTINUED NOTICE Provide make up air for proper ventilation. Do not install the unit where ducts are configured as shown in below. Adaptor Excessive bending DESCRIPTION Successive bending Squeezed duct Bend close to duct adaptor When one switch is connected with two or more products in parallel, the unit may not function. Therefore, parallel connection should not be allowed. These products are listed by UL under UL file No. E78414. These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. (FV-0511VQC1 only) This Panasonic ventilating fan model is equipped with a motion sensor and a humidity sensor that turn on automatically when motion is detected, when humidity increases rapidly, or when humidity rises above a 30% ~ 80% relative humidity set-point. It is user-adjustable to operate 0.5 ~ 60 minutes after the sensors are no longer detected. UNPACKING Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. SUPPLIED ACCESSORIES Part name Appearance Quantity Part name Appearance Quantity Grille Warranty 1 1 sheet Flex-Z Fast bracket (with 4 tapping screws -ST4.2X20) 1 Installation instructions Self-drilling screw 1 4 4

DIMENSIONS FV-0511VQ1, 7/8 (23.5) 3 3 3/8 (86) 13 (330) 5 7/8 (148) 3 7/8 (100) 5 7/8 (151) 12 (304) 10 1/4 (260) 4 3 3/8 (86) 6 13 1/4 ~ 15 1/2 (336~394) 16 1/2 ~ 18 3/4 (419~480) 21 1/4 ~ 23 1/2 (540~597) 5 1 Unit: inches (mm) 1 1/2 (37) 4 1/2 (114) 6 5/8 (169) 2 9 8 7 1/2 (190) 13 (330) 7 10 1/4 (261) 3 7/8 (100) No. 1 Blade 2 Grille 7 Fan body 3 8 Damper 4 Junction box Adaptor 9 Flex-Z Fast bracket 5 PCB box Part name No. 6 Part name Pick-A-Flow switch 3 7/8 (100) FV-0511VQC1 1 1/2 (37) 3 7/8(100) 5 7/8 (151) 2 10 11 4 1/2 (114) 4 9 7 1/2 (190) 13 1/4 ~ 15 1/2 (336~394) 16 1/2 ~ 18 3/4 (419~480) 21 1/4 ~ 23 1/2 (540~597) 3 3 3/8 (86) 6 13 (330) 5 12 (304) 10 1/4 (260) 1 7/8 (23.5) 8 13 (330) 7 No. 1 Blade 2 Grille 8 Damper 3 Junction box Adaptor 9 10 Flex-Z Fast bracket Selector 11 Motion sensor location 4 10 1/4 (261) 3 7/8 (100) 5 6 Part name PCB box Pick-A-Flow switch No. 7 Part name Fan body 5

WIRING DIAGRAM FV-0511VQ1, Fan body Main control circuit DC Motor Main control circuit Junction box White Black Neutral Live (Fan) AC120V 60Hz (Power supply) Green (Ground wire) FV-0511VQC1 Fan body Main control circuit DC Motor Main control circuit Humidity sensor Junction box White Black Neutral Live (Fan) AC120V 60Hz (Power supply) Motion sensor Humidity setting Selector Timer Green (Ground wire) SELECTOR INDICATION (FV-0511VQC1 only) Humidity preset selector Timer preset selector Selector indications on blower unit Humidity selector range from around 30% to 80% Factory setting is around 50%. Timer preset selector positions Timer [min] Factory setting : 20 minutes. Position : For factory use 0.5 1 2 3 5 10 20 30 60 6

OPERATION (FV-0511VQC1 only) Panasonic ventilating fan responds to: (1) Motion sensor detectible condition. (2) Humidity sensor detectible condition. Motion sensor detectible condition The delay time is determined by timer preset switch. The unit continues running for an adjustable duration of 0.5 to 60 minutes, after motion is no longer detected. Human activity Fan activity INSIDE Stop 10 feet (3m) When motion is detected, fan runs sensor OUTSIDE 90 Remains running until the delay time has passed The distance that motion can be detected is limited to 10 feet (3m). The field of view of the sensor is 90. Room temperature is 25 C (77 F). 1. The product will run when environment humidity rise rapidly but not reach to the humidity setting, and stop after delay preset time. 2. Humidity setting selector is stepless change between 30 %RH~80 %RH. 3. The humidity detected by sensor may differ from the value on your hygrometer. 4. The product may turn on and off cause by the unstable environment humidity, you can improve it by adjusting the Humidity setting selector. FEATURE Optimum Ventilation Performance: Duct length, elbows and other factors increase static pressure which can hinder the performance of most ventilation fans. This fan utilizes Smart Flow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within the ducts. This feature allows the fan to perform as rated and avoid potential installation issues. Outstanding Energy Savings: The Whisper ventilating fans are built using DC motor technology. The DC motor is 30% - 70% more energy efficient than the AC motor. Pick-A-Flow switch Pick-A-Flow Feature All the Whisper ventilating fans come with Pick-A-Flow speed options. The Pick-A-Flow switch on the face of all Whisper ventilating fans allow the option to choose 50 80 110 CFM for the FV-0511VQ1 or 110 130 150 CFM for the. These fans can run with constant air volume depending upon the needs of the owner. Air volume(cfm) FV-0511VQ1 50 110 80 130 Factory setting 110 80 CFM 150 130 CFM FV-0511VQC1 50 80 110 80 CFM 7

INSTALLATION (NEW CONSTRUCTION) The fan position between joists from 16" to 24" on center can be adjusted flexibly. Adaptor Machine screw (M4X8) Please wear gloves during the installation work as follow. 1. Disconnect plug connector from receptacle (Fig.6) and remove adaptor from fan body by removing the machine screw (M4X8) before installation. (Fig.1) IMPORTANT: Remove the tape from damper and adaptor before installation. As shown below: Adaptor Fan body Fig.1 Joist Damper Tape Bend down 4 tabs 2 Tapping screws (ST4.2X20) 2. Bend down 4 tabs for positioning, install the Flex-Z Fast bracket to joists by drilling 2 tapping screws which have been fixed on it. (Fig.2) 3. Adjust the length of Flex-Z Fast bracket as the spacing between joists, and install to joists by drilling the other 2 tapping screws which have been fixed on it. (Fig.3) 4. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.4) 5. Install a circular duct and secure it with clamps, or ties and seal it with mastic or approved foil tape. A 4 or 6 inch circular duct is needed to connect to relevant part of adaptor. (Fig.4) 6. Install the adaptor to Flex-Z Fast bracket by using 2 self-drilling screws. (Fig.4) Fig.2 Joist 2 Tapping screws (ST4.2X20) Fig.3 Conduit Circular duct Mastic or approved foil tape Knock-out hole Junction box cover 2 Self-drilling screws Fig.4 7. Refer to WIRING DIAGRAM. Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires. (Fig.5) Mount junction box cover carefully so that lead wires are not pinched. 8 WHITE BLACK GREEN Wire nuts Conduit Junction box Earth ground Switch box Neutral N Earth ground Live L 120 VAC LINE IN Fig.5

INSTALLATION (NEW CONSTRUCTION) CONTINUED 8. Insert fan body and slide into adapter assy with some strength, until the flange overlaps the Flex-Z Fast bracket. Secure the fan body to Flex-Z Fast bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X8). (Fig.6) Secure machine screw (M4X8) to the suitable hole and not touch the Flex-Z Fast bracket. Please fix the screw carefully to avoid screw slip teeth. 9. Finish ceiling work. hole should be aligned with the inside edge of the flange. (Fig.7) Joist Plug connector Receptacle 10 1/2 (270) Machine screw (M4X8) 10 1/2 (270) 2 Self-drilling screws Fig.6 Unit: inches (mm) After finishing the ceiling job, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage Fig.7 10. Insert the grille mounting spring on the wiring side into the slot. (Fig.8) 11. Insert the motion sensor on the grille and dress the wire as shown. (Fig. 8) 12. Adjust Pick-A-Flow switch.(refer to indication on FEATURE) 13. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.9) Motion Sensor (FV-0511VQC1 only). Clasp Mounting spring Fig.8 Mount grille carefully so that lead wire is not pinched. Grille Gloves Fig.9 9

INSTALLATION (RETROFIT) WARNING Disconnect power source before working on unit. 1. Remove the existing fan and cut ceiling opening. Secure the Flex-Z Fast bracket to joists by drilling 4 tapping screws (ST4.2x20) which have been fixed on it. Existing ductwork and wiring left in place. (Fig.10) 2. Follow the step 1, 4, 5, 7 on INSTALLATION (NEW CONSTRUCTION). (Before connect the circular duct to the adaptor, should pull down the circular duct from the ceiling) 3. Install the adaptor to Flex-Z Fast bracket by using 2 self-drilling screws. (Fig.11) 4. Secure the fan body to Flex-Z Fast bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X8). (Fig.12) Conduit (already existed) Knock-out hole Junction box cover Circular duct 4Tapping screws(st4.2x20) 10 7/8 (275) Conduit Circular duct 2 Self-drilling screws Unit: inches (mm) Joist 10 7/8 (275) Mastic or approved foil tape Fig.10 Joist Fig.11 Secure machine screw (M4X8) to the suitable hole and not touch the Flex-Z Fast bracket. Please fix the screw carefully to avoid screw slip teeth. 5. Follow the step 10 to 13 on INSTALLATION (NEW CONSTRUCTION). MAINTENANCE (CLEANING) Joist Machine screw (M4X8) 2 Self-drilling screws (Fix the flange and Flex-Z Fast bracket through the ceiling) Flange Fig.12 10 WARNING Disconnect power source before working on unit. Routine maintenance must be done every year. Please wear gloves during the cleaning work. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan. Do not immerse motor in water when cleaning. Do not soak resin parts in water over 140 F (60 C). Do not use cleaning sprays, solvents, or water on or near the sensors.

MAINTENANCE (CLEANING) CONTINUED 1. Remove grille by pulling down one mounting spring (Fig.13), then pull down the other. (Pull down the mounting spring that without lead wire passed side, and remove motion sensor as shown in Fig.14) (Squeeze mounting spring and pull down carefully) Mounting spring Grille Gloves Slot Fig.13 2. Clean grille. (Don t put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth) (Fig.15) Clasp 3. The grille should be dry after cleaning. Motion sensor (FV-0511VQC1 only) 4. Remove dust and dirt from fan body using a vacuum cleaner. (Fig.16) 5. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with clean cloth. (Fig.17) Fig.14 Gloves Fig.15 6. Reinstall grille. Vacuum cleaner Fig.16 Fig.17 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to 4 inches or 6 inches roof jack, wall cap, minimize building heat loss and gain. (Fig.18) or soffit vent with backdraft damper Loose fill or batt insulation can be placed Mechanically connect duct to termination and seal with mastic or approved foil directly over the fan housing in the attic. Our fans does not create excessive heat that faced tape 2-3 ft straight run before elbow is a common problem with recessed light ln attic installation, fixtures or some competitor s fan/light caulk box to drywall combination. Our efficient, cool-running motors do not create enough ambient heat Short piece of flexible duct helps lnsulation to be subjected to these limitations. alignment and absorbs sound. Clamps plus mastic or approved Foil tape tightly covers all metal The ducting from this fan to the outside of Fig.18 foil faced tape at all flex joints duct joints (glue PVC joints) the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow. 11

SPECIFICATIONS Model No. FV-0511VQ1 FV-0511VQC1 Air direction Exhaust 120 60 4 or 6 Exhaust Exhaust Voltage (V) 120 120 HVI Certified performance based on HVI Procedures 915, 916, and 920. PRODUCT SERVICE Frequency (Hz) 60 60 Duct diameter (inches) 6 4 or 6 Air volume at 0.1"WG (CFM) Noise (sones) Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada). Speed (rpm) Power (W) Weight Ib.(kg) 50 80 110 <0.3 <0.3 <0.3 756 821 957 4.1 6.0 10.8 9.3(4.2) 110 130 150 <0.3 <0.3 <0.3 636 671 698 6.9 9.1 11.9 9.5(4.3) 50 <0.3 756 4.1 80 <0.3 821 6.0 9.5(4.3) 110 <0.3 957 10.8 Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 www.panasonic.com Panasonic Corporation 2017 Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3 www.panasonic.ca Printed in Mexico P0717-0 15VQ10420B