Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Similar documents
Mission Critical Air Conditioning Systems

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series PS6, Vertical Floor-Mount Units

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Flexible & Innovative. Cooling Solutions

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

C13-Series Engineering Guide

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

Portable Vertical Air-Conditioning and Heating Systems

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

VariCool VAV Engineering Guide

Computer Room Air-Conditioning 60 Hz. Technical Data

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

EDPAC International Close Control Air Conditioning Products E

VertiCool Aurora Engineering Guide

THE ULTIMATE ROOFTOP SOLUTION

Guide Specifications for InRow Direct Expansion

MACH N-407 Heat Pump Air-Cooled Chiller

Data Aire Series Chilled Water 7 through 50 ton

MAC N-407 Air-Cooled Chiller

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MISSION CRITICAL Air Conditioning Systems. Maintenance Guide. ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

Commercial Packaged Rooftop Systems

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

System 2100 & System 2100k

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Chilled Water 7 to 211 kw

ALL PRODUCTS BROCHURE

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

The ultimate fresh air solution.

Liebert Mini-Mate2 1 To 8 Tons

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Liebert CSU3000 Chiller

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Chilled Water 7 to 211 kw

gforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SECTION FAN COIL UNITS

AIR COOLED PACKAGED CHILLER

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

CoolSpot Engineering Guide

Liebert Mini-Mate2 1 To 8 Tons

R-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits

Liebert Mini-Mate2 1 To 8 Tons

Innovative Design, Performance, & Serviceability

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

gforce Units Data Aire and Data Temp Series

Contents. APC NetworkAIR AFX AFX

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

SECTION COMPUTER-ROOM AIR-CONDITIONERS

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits

Water-Cooled Self-Contained Units

TYPICAL CPA SPECIFICATIONS

VERTICAL FAN COIL UNITS

MAC-120HE-03 Air-Cooled Chiller

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

CENTRAL SPLIT UNIT UNIC

Computer Room Air-Conditioning 60 Hz. Technical Data

Advance Release September 2009

AIR HANDLER SPECIFICATION

SSL & SBS Engineering Guide

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Operation & Maintenance Manual

PACKAGED AIR COOLED Product Data Catalog

Commercial High-Efficiency Condensing Units

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Transcription:

Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection

Series 6 2-5 tons Compact Footprint to Allow Efficient Use of Floor Space Series 8 6-10 tons Single Circuit for Cost Effective Cooling Series 9 6-30 tons Dual Circuit Reliability for the Ultimate Protection Mission Critical Climate Control

Series 6 2-5 Tons Compact Footprint to Allow Efficient Use of Floor Space Cooling Modes Air Cooled DX ( Split or Packaged) Water Cooled DX Glycol Cooled DX Chilled Water configurations Up Flow Down Flow DX in 407C reheat options SCR Controlled Electric Optional Upsize SCR Controlled Electric Reheat SCR RE-HEAT Silicon Controlled Rectifier (SCR) controlled, with an extruded aluminum heat sink. Heating element-low watt-density, tubular finned construction with a non-corrosive metal sheath electrically and thermally protected. TEMPERATURE & HUMIDITY SENSOR FILTERS Standard capacity, Merv 8 filters, 50mm (2") deep, pleated type having 25-30% efficiency, 90-92% arrestance to ASHRAE 52-76. PANELS & INSULATION Panels formed & welded from 18 gauge steel with Epoxy Powder Paint and Insulation is 25mm (1") thick, 24kg/m3 (1.5 lb/ft 3 ) density fiber-glass. EVAPORATOR COIL & DRAIN PAN Coil-3/8" OD copper tubes expanded into aluminum fins. Stainless Steel corrosion free condensate drain pan under the coil. FRAME 14 Gauge Steel with Epoxy Powder Paint. Microprocessor based control system with automatic control and monitoring capability. HUMIDIFIER Self-contained electrode boiler type c/w with water level control and auto-drain functions. BLOWER & MOTOR Blower-Double inlet, double width, forward curve, belt driven centrifugal type blower. Fan Motor-Totally Enclosed Air Cooled type (TEAO) having class F insulation, IP54 standard. Blanking plate removed to illustrate motor & blower. SCROLL COMPRESSOR Equipped with: Suction rotolock valve Discharge rotolock valve Gauge ports Internal thermal overload Vibration isolators Crank Case Heater AIR COOLED DOWN FLOW - MODEL 6AD05 DISCONNECT Non-Fused Locking Type. 100% FRONT SERVICEABLE

6-10 Tons Series 8 Single Circuit for Cost Effective Cooling Cooling Modes Air Cooled DX Water Cooled DX Glycol Cooled DX Chilled Water configurations Up Flow-Front or Rear Return (Option) Down Flow DX in 407C reheat options SCR Controlled Electric (Optional Upsize) Hot Water Reheat Coil Steam Reheat Coil Hot Gas Reheat Coil PANELS & INSULATION Panels formed & welded from 18 gauge steel with Epoxy Powder Paint and Insulation is 25mm (1" thick, 24kg/m 3 (1.5 lb/ft 3 ) density fiber-glass. DISCONNECT Non-Fused Locking Type. Microprocessor based control system with automatic control and monitoring capability. BLOWER & MOTOR Blower-Double inlet, double width, forward curve, belt driven centrifugal type blower. Fan Motor- Totally Enclosed Air Cooled type (TEAO) having class F insulation, IP54 standard. EVAPORATOR COIL & DRAIN PAN Coil-3/8" OD copper tubes expanded into aluminum fins. Stainless Steel corrosion free condensate drain pan under the coil. FILTERS Standard capacity, Merv 8 filters, 100mm (4" ) deep, pleated type having 25-30% efficiency, 90-92% arrestance to ASHRAE 52-76. SCR RE-HEAT Silicon Controlled Rectifier (SCR) controlled, with an extruded aluminum heat sink. Heating element-low watt-density, tubular finned construction with a non-corrosive metal sheath electrically and thermally protected. AIR COOLED UP FLOW UNIT LEFT END VIEW HUMIDIFIER Self-contained electrode boiler type c/w with water level control and auto-drain functions. SCROLL COMPRESSOR Equipped with: Suction rotolock valve Discharge rotolock valve Gauge ports Internal thermal overload Vibration isolators Crank Case Heater FRAME 14 Gauge Steel with Epoxy Powder Paint. AIR COOLED DOWN FLOW UNIT LEFT END VIEW AIR COOLED UP FLOW - MODEL 8AU10 Mission Critical Climate Control

Series 9 UP FLOW 6-30 Tons Dual Circuit Reliability for the Ultimate Protection Cooling Modes Air Cooled DX Water Cooled DX Glycol Cooled DX Chilled Water Dual and Free Cool configurations Up Flow-Front or Rear return (Option) DX in 407C reheat options SCR Controlled Electric (Optional Upsize) Hot Water Reheat Coil Steam Reheat Coil Hot Gas Reheat Coil BLOWER & MOTOR Blower-Double inlet, double width, forward curve, belt driven centrifugal type blower. Fan Motor-Totally Enclosed Air Cooled type (TEAO) having class F insulation, IP54 standard. PANELS & INSULATION Panels formed & welded from 18 gauge steel with Epoxy Powder Paint and Insulation is 25mm (1") thick, 24kg/m 3 (1.5 lb/ft 3 ) density fiber-glass. Microprocessor based control system with automatic control and monitoring capability. DUAL SCROLL COMPRESSORS Equipped with: Suction rotolock valve Discharge rotolock valve Gauge ports Internal thermal overload Vibration isolators Crank Case Heater HUMIDIFIER Self-contained electrode boiler type c/w with water level control and autodrain functions. DISCONNECT Non-Fused Locking Type. End Panel Removed EVAPORATOR COIL & DRAIN PAN Coil-3/8" or 1/2" OD copper tubes expanded into aluminum fins. Stainless Steel corrosion free condensate drain pan under the coil. SCR RE-HEAT Silicon Controlled Rectifier (SCR) controlled, with an extruded aluminum heat sink. Heating element-low watt-density, tubular finned construction with a non-corrosive metal sheath electrically and thermally protected. FRAME 14 Gauge Steel with Epoxy Powder Paint. FILTERS Standard capacity, Merv 8 filters, 100mm (4") deep, pleated type having 25-30% efficiency, 90-92% arrestance to ASHRAE 52-76. AIR COOLED UP FLOW - MODEL 9AU16

6-30 Tons DOWNFLOW Dual Circuit Reliability for the Ultimate Protection Series 9 Cooling Modes configurations Down Flow-Front or Rear return (Option) DX in 407C reheat options SCR Controlled Electric (Optional Upsize) Hot Water Reheat Coil Steam Reheat Coil Hot Gas Reheat Coil Air Cooled DX Water Cooled DX Glycol Cooled DX Chilled Water Dual and Free Cool EVAPORATOR COIL & DRAIN PAN Coil-3/8" or 1/2" OD copper tubes expanded into aluminum fins. Stainless Steel corrosion free condensate drain pan under the coil. FILTERS Standard capacity, Merv 8 filters, 100mm (4") deep, pleated type having 25-30% efficiency, 90-92% arrestance to ASHRAE 52-76. Input/Output (I/O) Board. Microprocessor based control system with automatic control and monitoring capability. DUAL SCROLL COMPRESSORS Equipped with: Suction rotolock valve Discharge rotolock valve Gauge ports Internal thermal overload Vibration isolators Crank Case Heater FRAME 14 Gauge Steel with Epoxy Powder Paint. PANELS & INSULATION Panels formed & welded from 18 gauge steel with Epoxy Powder Paint and Insulation is 25mm (1") thick, 24kg/m 3 (1.5 lb/ ft 3 ) density fiber-glass. BLOWER & MOTOR Blower-Double inlet, double width, forward curve, belt driven centrifugal type blower. Fan Motor-Totally Enclosed Air Cooled type (TEAO) having class F insulation, IP54 standard. DISCONNECT Non-Fused Locking Type. HUMIDIFIER Self-contained electrode boiler type c/w with water level control and autodrain functions. AIR COOLED DOWN FLOW - MODEL 9AD12 MODELS 26 & 30 ARE THREE (3) FAN UNITS Mission Critical Climate Control

Options Configure the Unit FACTORY SPLIT SERIES 9 Compressor Compartment is split from Air Handling (Fan/ Coil) Section into two (2) separate pieces for transport through confined spaces. Section refrigeration piping and electrical wiring are field connected on site BY OTHERS. 3-WAY VALVES Chilled Water or Condenser Water Regulating Valve c/w Bypass balancing valve (150 psi). FLOOR STANDS Floor stand shall be a welded steel frame with corrosion resistant finish in heights from 8 to 24 inches. The stands shall have adjustable legs for levelling with 1 inch of adjustment. Air Handling (Fan Coil) Section Chilled Water 3-Way Valve Condenser Water 3-Way Valve Series 6 Series 8 Series 9 Compressor Compartment Turning vanes are available for down discharge units (minimum height for a floor stand c/w Turning Vane is 12 inches). For floor stands greater than 24 inches please consult factory. CONDENSATE PUMP Condensate pump shall remove condensate from evaporator and humidifier when a drain is not available near by. Pump is shipped loose for field installation. Optional factory mounted and wired pumps are available for some models. Pump shall be capable of 37 GPH at 20' of head. SINGLE POINT LIQUID DETECTION Liquid detection shall consist of a single point liquid sensor. Sensor wires directly into the microprocessor and includes 10 feet of wire for field placement. CABLE LIQUID DETECTION Liquid detection shall consist of liquid cable sensor. Cable wires directly into the microprocessor and includes 10 feet of wire to extend to the bottom of the unit and 15 feet of sensing cable shall be supplied with the unit for field placement. HIGH LIMIT CUT OUT Factory mounted and wired to shut the unit down in the event of high heat detection (130F). SMOKE DETECTOR Smoke detector is factory mounted and wired to shut unit down in the event of the presence of smoke. SPRING OPEN/CLOSE CHILLED WATER VALVE ACTUATOR Chilled Water Valve (CW) actuator to position CW valve in Open or Close upon loss of power. DISCHARGE & RETURN AIR PLENUMS Factory plenums match unit and allows upflow units to supply air directly to space. Plenum has front double deflection grilles and is internally insulated. Return air plenums are available to match units in customer specified heights with and without filter access doors. Series 6 Series 8 Series 9

ClimateWorx International Inc. is focused on research, design, manufacture and application of Precision Air Conditioning Equipment providing reliable mission critical climate control. ClimateWorx s offering and design capabilities can meet your specifications with product lines of vertical floor mount, wall mount, ceiling mount, plenum fan and in-row units. ClimateWorx, a family and employee owned and operated business is fully committed to offering superior service and state of the art quality standards to satisfy our customers needs. Our dedicated research and development team works continuously to improve the current product line as well as focusing on the development of new products that are needed to compete in the Data Center Cooling arena. With the support of solid market leaders, including BMP Metals Inc. (www.bmpmetals.com) and CableTalk Systems Inc. (www.cabletalk.com) which have been providing quality integrated solutions for nearly three decades, ClimateWorx can offer comprehensive solutions for all your Data Centre needs. Robert R. Bédard Director rrbedard@climateworxinternational.com 1-800-648-2584 Our Mission To offer superior service and state of the art quality standards for the mutual benefit of our customers and employees. OUR VISION We will be globally recognized as a leader in the design and manufacture of innovative, quality solutions that satisfy the requirements of mission-critical environments. Mission Critical Climate Control ClimateWorx International Inc. 14 Chelsea Lane Brampton ON, L6T 3Y4, Canada Tel: (905) 405-0800 Fax: (905) 405-0807 1-800-648-2584 www.climateworxinternational.com ISO 9001:2008 All rights reserved. In the interest of continuous improvement, ClimateWorx reserves the right to change specifications without notice. All ClimateWorx International Series 6/8/9 equipment are ETL listed to comply to UL-1995 and CAN/CSA-C22.2 No. 236 for Heating and Cooling Equipment. ClimateWorx International Inc. is part of the Bempro Global Group of companies. COLE-CW-S689-B 2014.01.02