your dust explosion protection experts

Similar documents
explosion protection automation global partner of the process industry

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Dependable Solutions for Gas Detection

INTERFACE AND SYSTEM SOLUTIONS. Explosion protection for automation

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Engineering Guideline. pac- Carriers Type Universal

Dräger Polytron 8310 IR Detection of flammable gases and vapour

PRODUCT NEWS FLASHING BEACONS FOR RUGGED CONDITIONS IN HAZARDOUS AREAS NEW FX15 SERIES OF FLASHING SIGNAL LIGHTS FOR USE IN EX ZONE 1/2 AND 21/22

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

PANELBOARD PROTECTION ON A GLOBAL SCALE

Integrated Solutions Low Voltage Systems

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Dräger Polytron 8100 EC Detection of toxic gases and vapors

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

polar zone components and systems for extreme temperatures

Applications. Standard Materials

Enraf Servo Gauge 854 XTG

Rosemount 2051T In-Line Pressure Transmitter

Dräger Polytron 8000 Stationary gas detector (EC)

Instrumentation Products and Applications

Enraf Servo Gauge 854 ATG

OPERATING AND INSTALLATION

OPTIBAR DP 7060 Supplementary Instructions

Dräger Polytron 5700 IR Detection of flammable gases and vapours

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

COMPACT FLAME CONTROLLER CFC 2000

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Rosemount 3051L Level Transmitter

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

EVLPF Series Compact Fluorescent

Rosemount 2051T In-line Pressure Transmitter

INFRARED WINDOW SERIES

Continuous level measurement Ultrasonic transmitters

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Level Measurement Continuous level measurement - Ultrasonic transmitters

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Industrial Fire Detection

Dräger Flame 2100 Flame Detection

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Hazardous Area Signalling

CONSTANT FILL LEVEL MONITORING AT COVESTRO AG

For Complete Fire and Gas Solutions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Flow Measurement SITRANS F C

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

AlarmLine Addressable Linear Heat Detector

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Applications and Features

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

operational excellence Solutions for

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

The Signal Is Clear TM

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Dräger Polytron 8310 Stationary gas detector (DSIR)

TELECOMMUNICATION. Telecommunication. Wireless Phone

Fan Heaters Type VLEx

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

56W Hazardous Location LED Light - C1D2 - Corrosion Resistant for Marine - Dimmable - DALI Network

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

SIL725 Safety Annunciator

Model 144H. Product Data Sheet , Rev DB February Content

Explosion Proof Combination Signal db (A) / 5 Joule

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

Dräger Flame 2500 Flame Detection

X11CA COMPUTER ANNUNCIATORS

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Explosion Protected Panelboards D2Z Series

The Next Generation Machine Protection System

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

SITRANS T temperature transmitters A broad product family for every application. sitrans

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

BOP Management System Information

Transcription:

your dust explosion protection experts

HMI Overview Camera Systems Pag. 2 Remote I/O Barriers & Isolators Pag. 3 Purge Pag. 3 Plugs & Receptacles Lighting Pag. 5 Control Stations Pag. 6

Terminal Boxes Pag. 7 Circuit Breaker Panel Pag. 8 Disconnect Switches Pag. 8 Signaling Pag. 9 Accessories Pag. 10

Camera Systems From compact cameras to dome cameras, and from the component to complete CCTV systems, R. STAHL offers an extensive range of ISview cameras for hazardous areas. State-of-the-art camera technology and intelligent software ensure optimum process and area monitoring in Ex and non-ex areas. With the world s smallest Ex-camera, you can monitor every part of a process. The lightweight dome camera is perfectly suitable for all-round monitoring. The PTZ and Zoom cameras cover processes as well as the environment, while the thermal imaging cameras capture objects, people and events in complete darkness. With their aluminium or stainless steel enclosures, all cameras withstand the most demanding chemical and mechanical stress. They are generally configurable for IPbased or analog transmission Tip! 2

Remote I/O IS1+ is the world s most widely installed remote I/O system in hazardous areas. In conjunction with over 30 years of experience and know-how with solutions from R. STAHL almost every task is possible. The system is continuously expanded and improved upon with new functionalities. Today it features a wide range of communication protocols including Ethernet connectivity and simple integration into asset management systems with a powerful DTM. Besides support of modern protocols, a long-lived and flexible I/O level is available as well. Based on experience with thousands of globally installed systems, R. STAHL now presents the most up-to-date I/O modules with IS1+. The future proof system solution for complex requirements in hazardous areas of today and tomorrow. Installation in hazardous areas Zone 1, Zone 2, Division 1 and Division 2. Fieldbus communication: Profibus DP V1 HART, Modbus RTU, Industrial Ethernet with Modbus TCP, EtherNet/IP, PROFINET and FF HSE Interfaces to I.S. and non I.S. field devices in division 1 / zone 1 Interfaces to pneumatic valves in division 1 / zone 1 Proactive Maintenance to NAMUR NE 107 with the integration of a blue LED to signify end of life Hot swap for all modules in hazardous areas System redundancy, media redundancy and optical rings DTM technology for full access to all system, IO and HART field device information Field enclosures in many versions, engineered to choice Barriers & Isolators Zener barriers are a robust and flexible solution to interface intrinsically safe field devices to control systems. We have an extensive range that covers many types of signals and through our pioneering work in safety barriers, our latest design allows incredibly easy installation and simple maintenance. The mounting & ground connections are combined in one solid action, and with the wide range and replaceable back-up fuse, make INTRINSPAK unique. Point-to-point connections using galvanic isolators are a proven and easy to apply solution to connect intrinsically safe field devices to control systems. The Ispac isolator series is designed for quick and cost-saving installation. All modules can be mounted individually, in groups or in pac-carriers a unique feature. ISpac isolators are perfectly suitable for functional safety applications, with SIL2 or SIL3 assessment including trip amplifiers. Asset management packages can be efficiently connected through a combination of isolators, HART multiplexers and wiring boards. 2 Complete spectrum in a compact design More than 180 variants but only one back-up fuse Installation and connection in one go Easy and quick installation pac-bus Three kinds of signals to indicate line faults Complete spectrum in a compact design Pac-Carrier fast integration Complete solution barriers, isolators and more, in the cabinet 3

Features: Stainless steel or anodized aluminum construction for superior corrosion resistance (NEMA 4,4X) Small Profile and light weight reduces installation footprint Global Certifications. Certified to: ATEX / IECEx / NEC / CEC in a single part number. Ideal for global companies looking to standardize on a single design Dry contact outputs for remote monitoring comes standard. PurgEx X, Y, Z Purge Integral Vent standard on 15 CU FT or smaller indicators (no need to purchase or install accessory vents) Stainless Steel or Anodized Aluminum Construction for Superior Corrosion Resistance (NEMA 4, 4X) Smallest Profile and Lightest Weight on the market reduces installation footprint Dry Contact Outputs for Remote Monitoring Come Standard. CE Marked Global Certifications Certified to ATEX / IECEx / NEC / CEC in a single part number. Integral Vent Most Compact Unit Easiest Install Light Weight 4

Plugs & Receptacles Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism prevents accidental removal of plug from receptacle under load. Horsepower rated disconnect switch 20A, 30A, 63A and 125A models. 5

Control Stations 8150 / 8040 Control Stations & 8150 Control Panels 8150 Features Attractive space efficient design. Enclosures made of Stainless Steel for excellent corrosion resistance. Snap-on mounting of individual components. High illumination LED pilot light from 12V to 254V, AC or DC with an operating life time over 100,000 hours. A variety of pushbuttons, control switches,illuminated pushbuttons and ammeters gaskets are concealed to protect from damage or premature aging by UV light and chemicals. Fluorsilicate gasket in standard push button actuators is suitable for a wide temperature range. Globally Certified. One part number provides Class I Division 2, ATEX and IECEx Zone 1 certifications. Also available in GOST-R, INMETRO, KGS, and others. Durable silicone foamed enclosure 8040 Features Attractive space efficient design. A variety of enclosure sizes made of Fiberglass Reinforced Polyester (FRP). Snap-on mounting of individal components. High illumination LED pilot light from 12V to 254V, AC or DC with an Tip! operating life time over 100,000 hours. A variety of pushbuttons. Control switches. Illuminated pushbutton. Durable EPDM enclosure gaskets are concealed to protect from damage or premature aging by UV light and chemicals. Fluorsilicate gasket in standard pushbutton actuators is suitable for a wide temperature range. 8150 Control Panel Features 8150 series control stations are designed to incorporate control and display devices. The number of units installed depends on the control station size and the space required to fit each device. Enclosures in 316L or 304 stainless steel Options: - Flanges - Cover Hinges Enclosures can be coupled together 6

Series Features: ch Terminal Boxes 8150 / 8146 Series Enclosures made of stainless steel, brushed finished (AISI 304) or (AISI 316L) Optional hinges with cam locks or screws cover Hinged Versions 130 opening angle -60 C to +70 C Ambient temperature Standard Range Circumferential protection channel prevents water entry External Grounded connection Flange plate screwed on from the outside enables simple installation Degree of protection IP66 Complete Global Certifications including IECEx, ATEX, NEC & CEC (Class 1, Division2) INMETRO, GOST Tip! Series Features: Pre-Configured with terminals mounted Made of Fiberglass Reinforced Polyester (FRP) 8 enclosure sizes with different depths For power and control circuits For I.S. circuits with blue terminals Entry hardware optional Field installation possible 7

Circuit Breaker Panel The EPIK Circuit Breaker Panel is made of 316L stainless steel housing provides high corrosion resistance and extends the life and safety of your system. The R. STAHL EPIK Circuit Breaker Panel is easy to operate, lightweight and easy to install compared to traditional explosion proof cast and bolted systems. Series Features: Up to 42 circuit GFI/GFCI available in 5mA and 30 ma Main breakers up to 250 amp Optional Switch rack assembly including photo cell and transformers available. Unique design specific to photo cell design with both battery back-up and standard fixtures. Disconnect Switches Fused / Non-Fused Series Features: ch Enclosed 316 stainless steel construction for maximum corrosion resistance. No conduit seals required for Class I, Division 2 areas. Lightweight construction as opposed to cast metal enclosures. Available in fused (7150) and non-fused (8150) versions (with J fuses). Pad lockable robust rotary handle and tapping required. 16A, 32A, 63A and 125A models. 3 pole (plus auxiliary) horsepower rated switch. Increased safety terminals and integrated round bar. Large grip, lockable handle. Multiple entry methods available. 8

Signaling XPPS / YODALEX / YA11 Fire Alarm Station XPPS Features The XPPS Series explosion proof fire alarm stations are the most compact fire alarm station on the market. Made of high strength metal die aluminium cast alloy, the R. STAHL series explosion proof fire alarm stations come standard with many features. Terminal block connections, D.P.D.T. contacts @ 10 amps, Standard Hex Key reset mechanism or optional key reset Standard T-Pull handle, with optional break glass with solid brass hammer and chain, or lift and pull cover. Offered in special colors: Orange, Yellow, Blue, etc. Available with custom silk screen wording (for additional languages or instruction). Yodalex YL6/YA6/FL6 Series Features: YL6 Football shaped horn/strobe combination unit weighs only 13 pounds Omni Directional high output horn 110dB max @ 1 meter 2 stage alarm, independently selectable 2nd stage All units share a common explosion proof housing - machined flame paths Meets UL, CUL, CSA, GOST, ATEX and IECEx Approvals ATEX / IECEx Approved for Gas & Dust (Zone 1 & 2, 21 & 22) Dual cable entry Aluminium enclosure with stainless steel hardware Lens guard provided as standard 5 Joule xenon - flash rate 1 per second. Weather proof flame retardant ABS compliant horn 7 Lens colors in flame retardant polycarbonate 32 selectable tones meeting international regulations Easy sound selection via DIL switches 10 & 20 Joule Beacon available with ATEX or IECEx certification Telephone initiate available on ATEX or IECEx models YA11 Features YA11 horn ABS aluminum construction weighs less than 3 pounds Low Profile (1.1 inch profile) 100dB at 1 meter NEMA 4x, IP66 32 sounds tones available meeting international regulations Prewired with 3 meter cable, ready for installation Meets UL, CUL, ATEX and IECEx approvals ATEX / IECEx approved for Gas & Dust (Zone 1, 2, 21, & 22) NEX / CEC Class I, Division 2, Class II, Division 2, Class III, Division 1 Sealing gasket and stainless steel hardware provided High perfomance red paint finish as standard 18-32 VDC 7 Lens colors in flame retardant polycarbonate -40ºC to +70ºC rated 9

Accessories Conduit Hubs & Cable Glands Conduit Hubs Series Features: For connecting conduit. Sizes 1/2-3 NPT. For Hazardous (classified) Locations. Material Zinc. The grounding locknut provides an increased safety terminal Conduit Hubs Series Features: For connecting conduit. Sizes 1/2-3 NPT. For Hazardous (classified) Locations. Material Zinc. The grounding locknut provides an increased safety terminal